964 resultados para Prostheses and Implants
Resumo:
OBJECTIVES: To assess retrospectively, over at least 5 years, the incidences of technical and biological complications and failures in young adult patients with birth defects affecting the formation of teeth. MATERIAL AND METHODS: All insurance cases with a birth defect that had crowns and fixed dental prostheses (FDPs) inserted more than 5 years ago were contacted and asked to participate in a reexamination. RESULTS: The median age of the patients was 19.3 years (range 16.6-24.7 years) when prosthetic treatment was initiated. Over the median observation period of 15.7 years (range 7.4-24.9 years) and considering the treatment needs at the reexamination, 19 out of 33 patients (58%) with reconstructions on teeth remained free from all failures or complications. From the patients with FDPs and single unit crowns (SCs) on implants followed over a median observation period of 8 years (range 4.6-15.3 years), eight out of 17% or 47% needed a retreatment or repair at some point due to a failure or a complication. From the three groups of patients, the cases with amelogenesis/dentinogenesis imperfecta demonstrated the highest failure and complication rates. In the cases with cleft lip, alveolus and palate (CLAP) or hypodontia/oligodontia, 71% of the SCs and 73% of the FDPs on teeth (FDP T) remained complication free over a median observation period of about 16 years. Sixty-two percent of the SCs and 64% of the FDPs on implants remained complication free over 8 years. Complications occurred earlier with implant-supported reconstructions. CONCLUSIONS: Because healthy, pristine teeth can be left unprepared, implant-supported SCs and FDPs are the treatment choice in young adults with birth defects resulting in tooth agenesis and in whom the edentulous spaces cannot be closed by means of orthodontic therapy. However, the trend for earlier and more frequent complications with implant-supported reconstructions in young adults, expecting many years of function with the reconstructions, has to be weighed against the benefits of keeping teeth unprepared. In cases with CLAP in which anatomical conditions render implant placement difficult and in which teeth adjacent to the cleft require esthetic corrections, the conventional FDP T still remains the treatment of choice.
Resumo:
The purpose of this implant study was to evaluate the transverse stability of the basal maxillary and mandibular structures. The sample included 25 subjects between 12 and 18 years of age who were followed for approximately 2.6 years. Metallic implants were placed bilaterally into the maxillary and mandibular corpora before treatment. Once implant stability had been confirmed, treatment (4 first premolar extractions followed by fixed appliance therapy) was initiated. Changes in the transverse maxillary and mandibular implants were evaluated cephalometrically and two groups (GROW+ and GROW++; selection based on growth changes in facial height and mandibular length) were compared. The GROW++ group showed significant width increases of the posterior maxillary implants (P <.001) and the mandibular implants (P =.009); there was no significant change for the anterior maxillary implants. The GROW+ group showed no significant width changes between the maxillary and mandibular implants. We conclude that (1) there are significant width increases during late adolescence of the basal mandibular and maxillary skeletal structures and (2) the width changes are related with growth potential.
Resumo:
The purpose of this study was to evaluate commercially pure titanium implant surfaces modified by laser beam (LS) and LS associated with sodium silicate (SS) deposition, and compare them with machined surface (MS) and dual acid-etching surfaces (AS) modified. Topographic characterization was performed by scanning electron microscopy-X-ray energy dispersive spectroscopy (SEM-EDX), and by mean roughness measurement before surgery. Thirty rabbits received 60 implants in their right and left tibias. One implant of each surface in each tibia. The implants were removed by reverse torque for vivo biomechanical analysis at 30, 60, and 90 days postoperative. In addition, the surface of the implants removed at 30 days postoperative was analyzed by SEM-EDX. The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of LS and SS were statistically higher than AS and MS. At 30 days, values removal torque LS and SS groups showed a statistically significant difference (p < 0.05) when compared with MS and AS. At 60 days, groups LS and SS showed statistically significant difference (p < 0.05) when compared with MS. At 90 days, only group SS presented statistically higher (p < 0.05) in comparison with MS. The authors can conclude that physical chemistry properties and topographical of LS and SS implants increases bone-implant interaction and provides higher degree of osseointegration when compared with MS and AS. © 2012 Wiley Periodicals, Inc.
Resumo:
This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.
Resumo:
PURPOSE: In the present cohort study, overdentures with a combined root and implant support were evaluated and compared with either exclusively root- or implant-supported overdentures. Results of a 2-year follow-up period are reported, namely survival of implants, root copings, and prostheses, plus prosthetic complications, maintenance service, and patient satisfaction. MATERIALS AND METHODS: Fourteen patients were selected for the combined overdenture therapy and were compared with 2 patient groups in which either roots or implants provided overdenture support. Altogether, 14, 17, and 15 patients (in groups 1, 2, and 3, respectively) were matched with regard to age, sex, treatment time, and observation period. The mean age was around 67 years. Periodontal parameters were recorded, radiographs were taken, and all complications and failures were registered during the entire observation time. The patients answered a 9-item questionnaire by means of a visual analogue scale (VAS). RESULTS: One implant failed and 1 tooth root was removed following longitudinal root fracture. Periodontal/peri-implant parameters gave evidence of good oral hygiene for roots and implants, and slight crestal bone resorption was measured for both. Technical complications and service performed were significantly higher in the first year (P < .04) in all 3 groups and significantly higher in the tooth root group (P < .03). The results of the VAS indicated significantly lower scores for satisfaction, speaking ability, wearing comfort, and denture stability with combined or exclusive root support (P < .05 and .02, respectively). Initial costs of overdentures with combined or root support were 10% lower than for implant overdentures. CONCLUSION: The concept of combined root and implant support can be integrated into treatment planning and overdenture design for patients with a highly reduced dentition.
Resumo:
PURPOSE Clinical studies related to the long-term outcomes with implant-supported reconstructions are still sparse. The aim of this 10-year retrospective study was to assess the rate of mechanical/technical complications and failures with implant supported fixed dental prostheses (FDPs) and single crowns (SCs) in a large cohort of partially edentulous patients. MATERIALS AND METHODS The comprehensive multidisciplinary examination consisted of a medical/dental history, clinical examination, and a radiographic analysis. Prosthodontic examination evaluated the implant-supported reconstructions for mechanical/technical complications and failures, occlusal analysis, presence/absence of attrition, and location, extension, and retention type. RESULTS Out of three hundred ninety seven fixed reconstructions in three hundred three patients, two hundred sixty eight were SCs and one hundred twenty seven were FDPs. Of these three hundred ninety seven implant-supported reconstructions, 18 had failed, yielding a failure rate of 4.5% and a survival rate of 95.5% after a mean observation period of 10.75 years (range: 8.4-13.5 years). The most frequent complication was ceramic chipping (20.31%) followed by occlusal screw loosening (2.57%) and loss of retention (2.06%). No occlusal screw fracture, one abutment loosening, and two abutment fractures were noted. This resulted in a total mechanical/technical complication rate of 24.7%. The prosthetic success rate over a mean follow-up time of 10.75 years was 70.8%. Generalized attrition and FDPs were associated with statistically significantly higher rates of ceramic fractures when compared with SCs. Cantilever extensions, screw retention, anterior versus posterior, and gender did not influence the chipping rate. CONCLUSIONS After a mean exposure time of 10.75 years, high survival rates for reconstructions supported by Sand-blasted Large-grit Acid-etched implants can be expected. Ceramic chipping was the most frequent complication and was increased in dentitions with attrition and in FDPs compared with SCs.
Reconstruction of bony facial contour deficiencies with polymethylmethacrylate implants: case report
Resumo:
Facial trauma can be considered one of the most serious aggressions found in the medical centers due to the emotional consequences and the possibility of deformity. In craniofacial surgery, the use of autologous bone is still the first choice for reconstructing bony defects or irregularities. When there is a shortage of donor bone or a patient refuses an intracranial operation, alloplastic materials such as polymethylmethacrylate (PMMA) can be used. The PMMA prosthesis can be pre-fabricated, bringing advantages such as reduction of surgical time, easy technical handling and good esthetic results. This paper describes the procedures for rehabilitating a patient with PMMA implants in the region of the face, recovering the facial contours and esthetics of the patient.
Resumo:
OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey's post-hoc test (p<0.05). RESULTS: Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. CONCLUSIONS: The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface.
Resumo:
A new digital computer mock circulatory system has been developed in order to replicate the physiologic and pathophysiologic characteristics of the human cardiovascular system. The computer performs the acquisition of pressure, flow, and temperature in an open loop system. A computer program has been developed in Labview programing environment to evaluate all these physical parameters. The acquisition system was composed of pressure, flow, and temperature sensors and also signal conditioning modules. In this study, some results of flow, cardiac frequencies, pressures, and temperature were evaluated according to physiologic ventricular states. The results were compared with literature data. In further works, performance investigations will be conducted on a ventricular assist device and endoprosthesis. Also, this device should allow for evaluation of several kinds of vascular diseases.
Resumo:
BACKGROUND AND OBJECTIVE: To compare the efficacy and longevity of nonpenetrating glaucoma surgery with and without the use of a nonabsorbable hydrophilic implant at the Oxford Eye Centre, Johannesburg, South Africa, and the Glaucoma Unit, Jules Gonin Ophthalmic Hospital, Lausanne, Switzerland. PATIENTS AND METHODS: In a nonrandomized, prospective study between March 1997 and December 2001, 48 eyes of 32 patients aged 18 to 86 years with primary open-angle glaucoma underwent nonpenetrating glaucoma surgery; 25 eyes with the implant and 23 eyes without it. Intraocular pressure (IOP) was recorded preoperatively and postoperatively at 1, 7, and 14 days, at 1, 3, and 6 months, and thereafter every 6 months. RESULTS: The mean preoperative IOP was 27.5 +/- 11.8 mm Hg (range, 20 to 64 mm Hg) in the implant group and 24.8 +/- 7.1 mm Hg (range, 16 to 38 mm Hg) in the control group. During the first 18 months of follow-up, both groups showed identical IOP progression and the mean IOP remained less than 14 mm Hg. After 2 years of follow-up, the IOP started to rise in the control group but remained stable in the implant group. After 30 months, the mean IOP was 12.4 +/- 2 mm Hg and the IOP decrease in percentage was 62% +/- 6% in the implant group (n = 13) versus 16.1 +/- 3 mm Hg and 34% +/- 13% in the control group (n = 15) (mean IOP, P = .0022; mean IOP decrease in percentage, P = .01). CONCLUSIONS: During the first 18 months, there was no difference in the outcomes between the two groups. After 2 years of follow-up, the mean IOP was lower and the IOP decrease in percentage was greater in the implant group compared with the control group.
Resumo:
The diagnostic yield of prosthetic joint-associated infection is hampered by the phenotypic change of bacteria into a sessile and resistant form, also called biofilm. With sonication, adherent bacteria can be dislodged from the prosthesis. Species identification may be difficult because of their variations in phenotypic appearance and biochemical reaction. We have studied the phenotypic, genotypic, and biochemical properties of Escherichia coli variants isolated from a periprosthetic joint infection. The strains were collected from synovial fluid, periprosthetic tissue, and fluid from the explanted and sonicated prosthesis. Isolates from synovial fluid revealed a normal phenotype, whereas a few variants from periprosthetic tissue and all isolates from sonication fluid showed different morphological features (including small-colony variants). All isolates from sonication fluid were beta-galactosidase negative and nonmotile; most were indole negative. Because of further variations in biochemical properties, species identification was false or not possible in 50% of the isolates included in this study. In contrast to normal phenotypes, variants were resistant to aminoglycosides. Typing of the isolates using pulsed-field gel electrophoresis yielded nonidentical banding patterns, but all strains were assigned to the same clonal origin when compared with 207 unrelated E. coli isolates. The bacteria were repeatedly passaged on culture media and reanalyzed. Thereafter, most variants reverted to normal phenotype and regained their motility and certain biochemical properties. In addition, some variants displayed aminoglycoside susceptibility after reversion. Sonication of an explanted prosthesis allows insight into the lifestyle of bacteria in biofilms. Since sonication fluid also reveals dislodged sessile forms, species identification of such variants may be misleading.
Resumo:
Evidence shows that the endocannabinoid system modulates the addictive properties of nicotine. In the present study, we hypothesized that spontaneous withdrawal resulting from removal of chronically implanted transdermal nicotine patches is regulated by the endocannabinoid system. A 7-day nicotine dependence procedure (5.2 mg/rat/day) elicited occurrence of reliable nicotine abstinence symptoms in Wistar rats. Somatic and affective withdrawal signs were observed at 16 and 34 hours following removal of nicotine patches, respectively. Further behavioral manifestations including decrease in locomotor activity and increased weight gain also occurred during withdrawal. Expression of spontaneous nicotine withdrawal was accompanied by fluctuation in levels of the endocannabinoid anandamide (AEA) in several brain structures including the amygdala, the hippocampus, the hypothalamus and the prefrontal cortex. Conversely, levels of 2-arachidonoyl-sn-glycerol were not significantly altered. Pharmacological inhibition of fatty acid amide hydrolase (FAAH), the enzyme responsible for the intracellular degradation of AEA, by URB597 (0.1 and 0.3 mg/kg, i.p.), reduced withdrawal-induced anxiety as assessed by the elevated plus maze test and the shock-probe defensive burying paradigm, but did not prevent the occurrence of somatic signs. Together, the results indicate that pharmacological strategies aimed at enhancing endocannabinoid signaling may offer therapeutic advantages to treat the negative affective state produced by nicotine withdrawal, which is critical for the maintenance of tobacco use.
Resumo:
BACKGROUND A catheter-based approach after fibrinolysis is recommended if fibrinolysis is likely to be successful in patients with acute ST-elevation myocardial infarction. We designed a 2x2 randomized, open-label, multicenter trial to evaluate the efficacy and safety of the paclitaxel-eluting stent and tirofiban administered after fibrinolysis but before catheterization to optimize the results of this reperfusion strategy. METHODS AND RESULTS We randomly assigned 436 patients with acute ST-elevation myocardial infarction to (1) bare-metal stent without tirofiban, (2) bare-metal stent with tirofiban, (3) paclitaxel-eluting stent without tirofiban, and (4) paclitaxel-eluting stent with tirofiban. All patients were initially treated with tenecteplase and enoxaparin. Tirofiban was started 120 minutes after tenecteplase in those patients randomly assigned to tirofiban. Cardiac catheterization was performed within the first 3 to 12 hours after inclusion, and stenting (randomized paclitaxel or bare stent) was applied to the culprit artery. The primary objectives were the rate of in-segment binary restenosis of paclitaxel-eluting stent compared with that of bare-metal stent and the effect of tirofiban on epicardial and myocardial flow before and after mechanical revascularization. At 12 months, in-segment binary restenosis was similar between paclitaxel-eluting stent and bare-metal stent (10.1% versus 11.3%; relative risk, 1.06; 95% confidence interval, 0.74 to 1.52; P=0.89). However, late lumen loss (0.04+/-0.055 mm versus 0.27+/-0.057 mm, P=0.003) was reduced in the paclitaxel-eluting stent group. No evidence was found of any association between the use of tirofiban and any improvement in the epicardial and myocardial perfusion. Major bleeding was observed in 6.1% of patients receiving tirofiban and in 2.7% of patients not receiving it (relative risk, 2.22; 95% confidence interval, 0.86 to 5.73; P=0.14). CONCLUSIONS This trial does not provide evidence to support the use of tirofiban after fibrinolysis to improve epicardial and myocardial perfusion. Compared with bare-metal stent, paclitaxel-eluting stent significantly reduced late loss but appeared not to reduce in-segment binary restenosis. CLINICAL TRIAL REGISTRATION URL: http://clinicaltrials.gov. Unique identifier: NCT00306228.
Resumo:
BACKGROUND Lower limb amputees exhibit postural control deficits during standing which can affect their walking ability. OBJECTIVES The primary purpose of the present study was to analyze the thorax, pelvis, and hip kinematics and the hip internal moment in the frontal plane during gait in subjects with Unilateral Transtibial Amputation (UTA). METHOD The participants included 25 people with UTA and 25 non-amputees as control subjects. Gait analysis was performed using the Vicon(r) Motion System. We analyzed the motion of the thorax, pelvis, and hip (kinematics) as well as the hip internal moment in the frontal plane. RESULTS The second peak of the hip abductor moment was significantly lower on the prosthetic side than on the sound side (p=.01) and the control side (right: p=.01; left: p=.01). During middle stance, the opposite side of the pelvis was higher on the prosthetic side compared to the control side (right: p=.01: left: p=.01). CONCLUSIONS The joint internal moment at the hip in the frontal plane was lower on the prosthetic side than on the sound side or the control side. Thorax and pelvis kinematics were altered during the stance phase on the prosthetic side, presumably because there are mechanisms which affect postural control during walking.
Resumo:
A partial review is proposed on the existing literature for the research performed in orthopedic implant used as drug delivery system. In the first part, an evaluation is given on the clinical need to deliver a drug in the surrounding of an implant. Secondly, a review of the clinical situation is developed for implants already used as drug delivery system. Experimental works performed for local delivery are reported. In particular, a description is given on the in vitro and in vivo studies where the implant is coated with different proteins or drugs. Finally, a conclusion is proposed on the next step in the development of orthopedic implant as drug delivery system mentioning also the industrial situation.