990 resultados para Power Protection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

On the floor of the Global Wage Report 2012/2013 by ILO, entitled Wages and equitable growth, the A. thinks that the wage regulation has to take into account competitiveness without compressing global aggregate demand. Therefore, International and European rules are necessary to avoid the spiral towards the wages dampen, which is bad for the economic development. The rules in action at the different levels are inadequate. The A. proposes an interpretation of Article 153 and Article 155 TFEU that is more suitable for a European regulation promoting better minimum wages and more coherent with the current legal framework of the right to pay, which can be considered, even if partially, as a social right.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Työn aluksi on käsitelty sähkövoimajärjestelmien stabiilisuutta yleisesti. Myös teollisuuden sähköverkkojen erityispiirteitä on tarkasteltu. Teollisuusverkkojen komponentteja koskevassa selvityksessä eri laitteet on käsitelty siten, että niiden tärkeimmät ominaisuudet verkon erilaisissa muutostilanteissa tulevat esille. Tahtigeneraattorit ja epätahtikoneet on käsitelty yksityiskohtaisesti. Tutkimuksessa on esitelty teollisuusverkon saarekekäyttöön johtavia syitä, saarekkeeseen siirtymisen kriteereitä ja saarekekäytön toteutustapoja. Tehonvajaussuojaukseen liittyen on tutustuttu kuormanpudotusjärjestelyihin. Myös höyryverkon kuormien tasausten mahdollisuuksiin on luotu katsaus. Verkostolaskentaa käsittelevässä luvussa on keskitytty sopivan laskentamallin luomiseen liittyviin menetelmiin ja rajoituksiin. Lisäksi on kerrottu työn käytännön osan laskentamallin luomisen keskeiset periaatteet. Työn lopuksi on suoritettu simulointeja, joissa on tutkittu erään teollisuusverkon stabiilisuutta saarekekäyttöön siirryttäessä Calpos-verkostolaskentaohjelmistolla.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Uusiutuvan energian tuottamisen lisääminen on edellytys saavuttaaksemme EU:n asettamat tavoitteet. Tämän takia on syytä tutkia kaikki mahdollisuudet uusiutuvan energian tuottamisen lisäämiseksi jopa aivan pienimmistä laitoksista lähtien. Tämän työn tarkoituksena on tutkia pienvesivoiman taloudellisuutta ja kannattavuutta energiantuotannossa. Työssä suoritetaan myös kustannuslaskenta, jossa pohditaan käytöstä poistetun laitoksen palauttamista takaisin sähkön tuotantoon. Samalla käydään läpi teknisiä, taloudellisia ja lakisääteisiä kysymyksiä, joita pienvoiman verkkoonliittäminen aiheuttaa. Tämä työ on eräänlainen käsikirja pienvesivoimasta. Pienvesivoiman liittäminen jakeluverkkoon on sinällään suojausteknisesti yksinkertaista, mutta kaikkien eri taloudellisten ja lakiteknisten tekijöiden huomioonottaminen on puolestaan haastavaa. Laitosten käyttö ja kunnossapito eivät sinällään vaadi sähköteknistä osaamista, kunhan turvallisuusseikat otetaan visusti huomioon. Työssä havaittiin, että pienvesivoima ei pienissä laitoksissa riitä kattamaan suuria työvoimakustannuksia, joita syntyy, kun yritysten henkilökunta ottaa osaa laitoksen toimintaan. Toisaalta pienvesivoima on erinomainen tapa tuottaa sähköä yksityiselle ihmiselle, mikäli hän on itse valmis operoimaan laitosta eikä laske omalle työlleen suuria kustannuksia. Edellytyksenä on, että omalta maa‐alueelta löytyy pienikin puro suhteellisen läheltä jakeluverkkoa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Disturbances in power systems may lead to electromagnetic transient oscillations due to mismatch of mechanical input power and electrical output power. Out-of-step conditions in power system are common after the disturbances where the continuous oscillations do not damp out and the system becomes unstable. Existing out-of-step detection methods are system specific as extensive off-line studies are required for setting of relays. Most of the existing algorithms also require network reduction techniques to apply in multi-machine power systems. To overcome these issues, this research applies Phasor Measurement Unit (PMU) data and Zubov’s approximation stability boundary method, which is a modification of Lyapunov’s direct method, to develop a novel out-of-step detection algorithm. The proposed out-of-step detection algorithm is tested in a Single Machine Infinite Bus system, IEEE 3-machine 9-bus, and IEEE 10-machine 39-bus systems. Simulation results show that the proposed algorithm is capable of detecting out-of-step conditions in multi-machine power systems without using network reduction techniques and a comparative study with an existing blinder method demonstrate that the decision times are faster. The simulation case studies also demonstrate that the proposed algorithm does not depend on power system parameters, hence it avoids the need of extensive off-line system studies as needed in other algorithms.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The power transformer is a piece of electrical equipment that needs continuous monitoring and fast protection since it is very expensive and an essential element for a power system to perform effectively. The most common protection technique used is the percentage differential logic, which provides discrimination between an internal fault and different operating conditions. Unfortunately, there are some operating conditions of power transformers that can affect the protection behavior and the power system stability. This paper proposes the development of a new algorithm to improve the differential protection performance by using fuzzy logic and Clarke`s transform. An electrical power system was modeled using Alternative Transients Program (ATP) software to obtain the operational conditions and fault situations needed to test the algorithm developed. The results were compared to a commercial relay for validation, showing the advantages of the new method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a novel graphical approach to adjust and evaluate frequency-based relays employed in anti-islanding protection schemes of distributed synchronous generators, in order to meet the anti-islanding and abnormal frequency variation requirements, simultaneously. The proposed method defines a region in the power mismatch space, inside which the relay non-detection zone should be located, if the above-mentioned requirements must be met. Such region is called power imbalance application region. Results show that this method can help protection engineers to adjust frequency-based relays to improve the anti-islanding capability and to minimize false operation occurrences, keeping the abnormal frequency variation utility requirements satisfied. Moreover, the proposed method can be employed to coordinate different types of frequency-based relays, aiming at improving overall performance of the distributed generator frequency protection scheme. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This prospective study applies an extended Information-Motivation-Behavioural Skills (IMB) model to establish predictors of HIV-protection behaviour among HIV-positive men who have sex with men (MSM) during sex with casual partners. Data have been collected from anonymous, self-administered questionnaires and analysed by using descriptive and backward elimination regression analyses. In a sample of 165 HIV-positive MSM, 82 participants between the ages of 23 and 78 (M=46.4, SD=9.0) had sex with casual partners during the three-month period under investigation. About 62% (n=51) have always used a condom when having sex with casual partners. From the original IMB model, only subjective norm predicted condom use. More important predictors that increased condom use were low consumption of psychotropics, high satisfaction with sexuality, numerous changes in sexual behaviour after diagnosis, low social support from friends, alcohol use before sex and habitualised condom use with casual partner(s). The explanatory power of the calculated regression model was 49% (p<0.001). The study reveals the importance of personal and social resources and of routines for condom use, and provides information for the research-based conceptualisation of prevention offers addressing especially people living with HIV ("positive prevention").

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tässä diplomityössä tutkittiin vaihtoehtoja tehoelektroniikkalaitteiden kotelointiluokan kehittämiseksi. Haasteena paremman suojauksen suunnittelussa on laitteiden tuottama suuri määrä lämpöä, joka vaatii tehokkaan jäähdytyksen. Työn tuloksena saatu prototyyppi IP33 luokkaa varten täyttää standardissa SFS-EN 60529+A1 asetetut vaatimukset kyseiselle kotelointiluokalle. Rakenteessa ja valmistettavuudessa havaittiin muutama ongelma, jotka ovat korjattavissa pienillä muutoksilla. Korkeampia suojausluokkia varten testattiin IP54-luokiteltujen filtterituulettimien vaikutusta laitteen jäähdytykseen. Testien perusteella jäähdytysteho on riittävä ja filtterituulettimet todettiin toimivaksi ratkaisuksi korkeammille suojausluokille. Työn perusteella voidaan todeta, että nykyiset laitteet voidaan muokata vastaamaan IP33 luokan vaatimuksia kohtuullisen pienillä muutoksilla. Tätä korkeammat suojausluokat vaatisivat niin suuria muutoksia designiin, että todennäköisesti täysin uuden laitteen suunnittelu olis kannattavin vaihtoehto.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis takes some steps in examining the child protection system from a position that is rarely discussed. Specifically, I explore how Foucault's concept of disciplinary power can be used to demonstrate how power operates within the client/worker relationship. This relationship is shown to be quite complex with power flowing bidirectionally, rather than hierarchically. Instead of viewing power imbalances as a function of state control, I show how the client/worker relationship is constituted by the worker, the client, the organization and the social body. A postmodern auto ethnography is used to document my journey as I expose the disciplinary practices and instruments that I was subject to and used with my clients. 2 Given that the child protection system is constantly shifting and changing in order to improve its ability to safeguard children a greater emphasis is required to examine how workers operate within this complex, overwhelming and multi-dimensional world. This thesis has shown that by engaging in a reflexive examination of my position of power different approaches to making intervention beneficial to all involved become available. This is important if child protection work aims to work with clients rather than on clients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The sixteenth-century Shebet Yehudah is an account of the persecutions of Jews in various countries and epochs, including their expulsion from Spain in the fifteenth century. It is not a medieval text and was written long after many of the events it describes. Yet although it cannot give us a contemporary medieval standpoint, it provides important insights into how later Jewish writers perceived Jewish–papal relations in the thirteenth, fourteenth, and fifteenth centuries. Although the extent to which Jewish communities came into contact either with the papacy as an institution or the actions of individual popes varied immensely, it is through analysis of Hebrew works such as the Shebet Yehudah that we are able to piece together a certain understanding of Jewish ideas about the medieval papacy as an institution and the policies of individual popes. This article argues that Jews knew only too well that papal protection was not unlimited, but always carefully circumscribed in accordance with Christian theology. It is hoped that it will be a scholarly contribution to our growing understanding of Jewish ideas about the papacy's spiritual and temporal power and authority in the Later Middle Ages and how this impacted on Jewish communities throughout medieval Europe.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper investigates the impact of monopoly power on trade policy. Annual panel-databases of Brazilian industries for the years 1988 through 1994 were used. The regressions reported here are robust to openness indicator, concentration index, control variables and sample size, and suggest that industries with higher monopoly power are more protected than competitive sectors. In the period of study the country experienced a major trade liberalization, but the results in the paper show that the reduction in protection was smaller in sectors with higher monopoly power. We thus have evidence favoring recent growth literature which stresses that interest groups with control over creasing productivity. The results here confirm the first part of this argument and show that organized groups in fact are able to obtain policy advantages that reduce competition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper investigates the impact of industry concentration on trade policy. Annual panel-databases of Brazilian industries for the years 1988 through 1994 were used. The regressions reported here are robust to openness indicator. concentration index, control variables and sample size, and suggest that the higher the concentration of a given industry the higher its leveI of trade protection. In the period of study the country experienced a major trade liberalization, but the results in the paper show that the reduction in protection was smaller in more concentrated sectors. Assuming that concentration is ;1 gCl()d proX\' for mOllopoh' po\\'er as it reduces the free-rider problem in coordinating a lobby the results in this paper indicates that interest groups with control over specific markets in fact are able to obtain policy advantages that reduce (international) competition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A power transformer needs continuous monitoring and fast protection as it is a very expensive piece of equipment and an essential element in an electrical power system. The most common protection technique used is the percentage differential logic, which provides discrimination between an internal fault and different operating conditions. Unfortunately, there are some operating conditions of power transformers that can mislead the conventional protection affecting the power system stability negatively. This study proposes the development of a new algorithm to improve the protection performance by using fuzzy logic, artificial neural networks and genetic algorithms. An electrical power system was modelled using Alternative Transients Program software to obtain the operational conditions and fault situations needed to test the algorithm developed, as well as a commercial differential relay. Results show improved reliability, as well as a fast response of the proposed technique when compared with conventional ones.