52 resultados para Penumbra


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of half-field beam penumbra were taken using EBT2 film for a variety of blocking techniques. It was shown that minimizing the SSD reduces the penumbra as the effects of beam divergence are diminished. The addition of a lead block directly on the surface provides optimal results with a 10-90% penumbra of 0.53 ± 0.02 cm. To resolve the uncertainties encountered in film measurements, future Monte Carlo measurements of halffield penumbras are to be conducted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdias do Nascimento foi responsável pela criaçao do Teatro Experimental do Negro (TEN) em 1944, uma vertente vanguardista da arte brasileira que propiciou a participaçao do negro no teatro, afastado de estereótipos. A complexa relaçao entre texto teatral e literatura tem como produto a literatura dramática, um texto amálgama que pode projetar conflitos sociais e a experiência do indivíduo. A peça Sortilégio (mistério negro) escrita por Abdias em 1951 é ambientada em um terreiro de candomblé e trata de questoes como a negaçao das raízes africanas, o embranquecimento, (Martins, 1995:105) e a propagaçao de um discurso alienante que inferioriza o sujeito negro. Sortilégio suscita discussoes sobre como o e problema do racismo tem sido abordado. Através da metáfora da penumbra procura-se uma alternativa de releitura da dos dramas raciais colocados na obra Sortilégio, para além da polarizaçao entre uma cultura "negra" e uma "branca".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdias do Nascimento foi responsável pela criaçao do Teatro Experimental do Negro (TEN) em 1944, uma vertente vanguardista da arte brasileira que propiciou a participaçao do negro no teatro, afastado de estereótipos. A complexa relaçao entre texto teatral e literatura tem como produto a literatura dramática, um texto amálgama que pode projetar conflitos sociais e a experiência do indivíduo. A peça Sortilégio (mistério negro) escrita por Abdias em 1951 é ambientada em um terreiro de candomblé e trata de questoes como a negaçao das raízes africanas, o embranquecimento, (Martins, 1995:105) e a propagaçao de um discurso alienante que inferioriza o sujeito negro. Sortilégio suscita discussoes sobre como o e problema do racismo tem sido abordado. Através da metáfora da penumbra procura-se uma alternativa de releitura da dos dramas raciais colocados na obra Sortilégio, para além da polarizaçao entre uma cultura "negra" e uma "branca".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdias do Nascimento foi responsável pela criaçao do Teatro Experimental do Negro (TEN) em 1944, uma vertente vanguardista da arte brasileira que propiciou a participaçao do negro no teatro, afastado de estereótipos. A complexa relaçao entre texto teatral e literatura tem como produto a literatura dramática, um texto amálgama que pode projetar conflitos sociais e a experiência do indivíduo. A peça Sortilégio (mistério negro) escrita por Abdias em 1951 é ambientada em um terreiro de candomblé e trata de questoes como a negaçao das raízes africanas, o embranquecimento, (Martins, 1995:105) e a propagaçao de um discurso alienante que inferioriza o sujeito negro. Sortilégio suscita discussoes sobre como o e problema do racismo tem sido abordado. Através da metáfora da penumbra procura-se uma alternativa de releitura da dos dramas raciais colocados na obra Sortilégio, para além da polarizaçao entre uma cultura "negra" e uma "branca".

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Slow potential recording was used for long-term monitoring of the penumbra zone surrounding an ischemic region produced by middle cerebral artery (MCA) occlusion in adult hooded rats (n = 32). Four capillary electrodes (El-E4) were chronically implanted at 2-mm intervals from AP -3, L 2 (El) to AP 0, L 5 (E4). Spontaneous or evoked slow potential waves of spreading depression (SD) were recorded during and 4 h after a 1-h MCA occlusion and at 2- to 3-day intervals afterward for 3 weeks. Duration of the initial focal ischemic depolarization was maximal at E4 and decreased with distance from the focus. SD waves in the penumbra zone were high at El and E2, low and prolonged at E3, and almost absent at E4. Amplitude of elicited SD waves was further reduced 3 days later and slowly increased in the following week. Cortical areas displaying marked reduction of SD waves in the first days after MCA occlusion either remained low or showed substantial (60%) recovery, the probability of which decreased with the duration of the initial focal ischemic depolarization and increased with the distance from the focus. It is concluded that the outcome of ischemia monitored by long-term SD recovery in the perifocal region can be partly predicted from the acute signs of MCA occlusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Organ motion as a result of respiration is an important field of research for medical physics. Knowledge of magnitude and direction of this motion is necessary to allow for more accurate radiotherapy treatment planning. This will result in higher doses to the tumour whilst sparing healthy tissue. This project involved human trials, where the radiation therapy patient's kidneys were CT scanned under three different conditions; whilst free breathing (FB), breath-hold at normal tidal inspiration (BHIN), and breath-hold at normal tidal expiration (BHEX). The magnitude of motion was measured by recording the outline of the kidney from a Beam's Eye View (BEV). The centre of mass of this 2D shape was calculated for each set using "ImageJ" software and the magnitude of movement determined from the change in the centroid's coordinates between the BHIN and BHEX scans. The movement ranged from, for the left and right kidneys, 4-46mm and 2-44mm in the superior/inferior (axial) plane, 1-21mm and 2- 16mm in the anterior/posterior (coronal) plane, and 0-6mm and 0-8mm in the lateral/medial (sagittal) plane. From exhale to inhale, the kidneys tended to move inferiorly, anteriorly and laterally. A standard radiotherapy plan, designed to treat the para-aortics with opposed lateral fields was performed on the free breathing (planning) CT set. The field size and arrangement was set up using the same parameters for each subject. The prescription was to deliver 45 Gray in 25 fractions. This field arrangement and prescription was then copied over to the breath hold CT sets, and the dosimetric differences were compared using Dose Volume Histograms (DVH). The point of comparison for the three sets was recorded as the percentage volume of kidney receiving less than or equal to 10 Gray. The QUASAR respiratory motion phantom was used with the range of motion determined from the human study. The phantom was imaged, planned and treated with a linear accelerator with dose determined by film. The effect of the motion was measured by the change in the penumbra of the film and compared to the penumbra from the treatment planning system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates the variation of photon field penumbra shape with initial electron beam diameter, for very narrow beams. A Varian Millenium MLC (Varian Medical Systems, Palo Alto, USA) and a Brainlab m3 microMLC (Brainlab AB. Feldkirchen, Germany) were used, with one Varian iX linear accelerator, to produce fields that were (nominally) 0.20 cm across. Dose profiles for these fields were measured using radiochromic film and compared with the results of simulations completed using BEAMnrc and DOSXYZnrc, where the initial electron beam was set to FWHM = 0.02, 0.10, 0.12, 0.15, 0.20 and 0.50 cm. Increasing the electron-beam FWHM produced increasing occlusion of the photon source by the closely spaced collimator leaves and resulted in blurring of the simulated profile widths from 0.26 to 0.64 cm, for the MLC, from 0.12 to 0.43 cm, for the microMLC. Comparison with measurement data suggested that the electron spot size in the clinical linear accelerator was between FWHM = 0.10 and 0.15 cm, encompassing the result of our previous output-factor based work, which identified a FWHM of 0.12. Investigation of narrow-beam penumbra variation has been found to be a useful procedure, with results varying noticeably with linear accelerator spot size and allowing FWHM estimates obtained using other methods to be verified.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Small field x-ray beam dosimetry is difficult due to a lack of lateral electronic equilibrium, source occlusion, high dose gradients and detector volume averaging. Currently there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). Methods Small field sizes were defined by BrainLAB circular cones (4 – 30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, Ω_(Q_clin,Q_msr)^(f_clin,f_msr ), were calculated by Monte Carlo methods using BEAMnrc and correction factors, k_(Q_clin,Q_msr)^(f_clin,f_msr ), were derived for the PTW 60019 microDiamond detector. Results For the small fields of 4 to 30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, Ω_(Q_clin,Q_msr)^(f_clin,f_msr ), were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, k_(Q_clin,Q_msr)^(f_clin,f_msr ), were derived for the PTW 60019 microDiamond detector. Conclusions We conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim A new method of penumbral analysis is implemented which allows an unambiguous determination of field size and penumbra size and quality for small fields and other non-standard fields. Both source occlusion and lateral electronic disequilibrium will affect the size and shape of cross-axis profile penumbrae; each is examined in detail. Method A new method of penumbral analysis is implemented where the square of the derivative of the cross-axis profile is plotted. The resultant graph displays two peaks in the place of the two penumbrae. This allows a strong visualisation of the quality of a field penumbra, as well as a mathematically consistent method of determining field size (distance between the two peak’s maxima), and penumbra (full-widthtenth-maximum of peak). Cross-axis profiles were simulated in a water phantom at a depth of 5 cm using Monte Carlo modelling, for field sizes between 5 and 30 mm. The field size and penumbra size of each field was calculated using the method above, as well as traditional definitions set out in IEC976. The effect of source occlusion and lateral electronic disequilibrium on the penumbrae was isolated by repeating the simulations removing electron transport and using an electron spot size of 0 mm, respectively. Results All field sizes calculated using the traditional and proposed methods agreed within 0.2 mm. The penumbra size measured using the proposed method was systematically 1.8 mm larger than the traditional method at all field sizes. The size of the source had a larger effect on the size of the penumbra than did lateral electronic disequilibrium, particularly at very small field sizes. Conclusion Traditional methods of calculating field size and penumbra are proved to be mathematically adequate for small fields. However, the field size definition proposed in this study would be more robust amongst other nonstandard fields, such as flattening filter free. Source occlusion plays a bigger role than lateral electronic disequilibrium in small field penumbra size.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated a potential source of inaccuracy for diode measurements in modulated beams; the effect of diode housing asymmetry on measurement results. The possible effects of diode housing asymmetry on the measurement of steep dose gradients were evaluated by measuring 5x5 cm2 beam profiles, with three cylindrical diodes and two commonly used ionization chambers, with each dosimeter positioned in a 3D scanning water tank with its stem perpendicular to the beam axis (horizontal) and parallel to the direction of scanning. The resulting profiles were used to compare the penumbrae measured with the diode stem pointing into (equivalent to a “stem-first” setup) and out of the field (equivalent to a “stem-last” setup) in order to evaluate the effects of dosimeter alignment and thereby identify the effects of dosimeter asymmetry. The stem-first and stem-last orientations resulted in differences of up to 0.2 mm in the measured 20-80% penumbra widths and differences of up to 0.4 mm in the off axis position of the 90% isodose. These differences, which are smaller than previously reported for older model dosimeters, were apparent in the profile results for both diodes and small volume ionization chambers. As an extension to this study, the practical use of all five dosimeters was exemplified by measuring point doses in IMRT test beams. These measurements showed good agreement (within 2%) between the diodes and the small volume ionization chamber, with all of these dosimeters being able to identify a region 3% under-dosage which was not identified by a larger volume (6 mm diameter) ionization chamber. The results of this work should help to remove some of the barriers to the use of diodes for modulated radiotherapy dosimetry in the future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A technique is described for calculating the brightness of the atmosphere of the Earth that shines into the Earth’s umbra during a total lunar eclipse making the Moon red. This ‘Rim of Fire’ is due to refracted un scattered light from all the sunrises and sunsets rimming the Earth. In this article, a photograph of the totally eclipsed Moon was compared with the Full Moon and the difference in brightness calculated taking into account the exposure time and ISO setting. The results show that the Full Moon is over 14 000 times brighter than the totally eclipsed Moon. The relative brightness of the eclipsed Moon can be used to estimate that the luminance of Rim of Fire is over 12 trillion watts. The experiment described in this paper would be suitable as a high school or university exercise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Con el objeto de contribuir al uso y manejo de nuevas especies forrajeras como alternativas para la alimentación animal en las condiciones agroclimáticas del municipio de Niquinohomo, específicamente en el Rancho Agropecológico de Especies Menores Ebenezer (RAEME). Se realizó un trabajo investigativo donde se evaluó las características morfoestructurales de nacedero (Trichanthera gigantea), bajo tres escenarios de sombra (umbra, penumbra y a pleno sol) y cuatro frecuencias de corte (30, 60, 90 y 120 días) y su efecto sobre la producción de biomasa y contenido de proteína de nacedero. El estudio se ubicó en la comarca Hoja Chigüe #1 a una distancia de 4 Km al sur del municipio de Niquinohomo, Departamento de Masaya con una altitud de 400 msnm, con latitud de 11° 52′ y longitud de 86°03′ . El promedio de precipitación anual es de 1200 mm, con periodos lluviosos generalmente en los meses de Julio a Noviembre. Con una temperatura mínimas de 22° C y máximas de 38° C, variando estas durante todo el año. Los suelos son de textura franco arcilloso y una profundidad efectiva de 40 cm. Entre las características morfoestructurales, se evaluaron el grosor, altura, número de tallos y rebrotes, para lo cual se realizaron mediciones sobre cinco plantas (para cada condición), sembrados a una distancia de 1 m entre surco y entre planta, las cuales se seleccionaron al azar. Al iniciar el estudio se hizo un corte de uniformidad; después se realizó el corte para cada frecuencia en estudio, cuantificando la producción de forraje comestible (hoja/tallo tierno y la proporción entre ellas). Durante el ensayo no se hizo ninguna aplicación de fertilizante. Se encontró que la producción de biomasa fue mejor cuando los cortes se realizaron cada 120 días, siendo estas mayores cuando estaban en condiciones de sombra y penumbra (31 y 32 t ha-1 respectivamente). En cambio los contenidos de proteína fueron mayores cuando los corteseran menores de 60 días, los cuales fluctuaron entre 20 y 23%. Encontrándose una relación inversa entre la edad de corte y producción de biomasa con respecto al contenido de proteína.