979 resultados para Partial time jamming


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed at evaluating the effectiveness of partial use of anterior repositioning appliances in the management of TMJ pain and dysfunction when compared to stabilization splints and a control group in a one-year follow-up. Sample was initially constituted by 60 patients, randomly divided into three groups: I- stabilization splints, II- repositioning splints and III- no treatment. The whole sample was evaluated by means of TMJ and muscle palpation, mandibular AROM, analysis of occlusal contacts, joint sounds inspection and Visual Analogue Scale (VAS) for one year; 52 patients composed the final sample. A significant (after 15 days) improvement in pain report (VAS) and palpation index was found for group II (p≤0.01). The occurrence of occlusal alterations as posterior open bite or gross interferences after the splint therapy and increased muscle tenderness were not problems in this study. Similar results in joint noises reduction were observed for the entire sample. It was concluded that controlled partial use of repositioning splints is a beneficial tool in the management of intra-articular pain and dysfunction, with no risks of irreversible occlusal changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel technique to obtain optimum blind spatialprocessing for frequency diversity spread spectrum (FDSS) communicationsystems is introduced. The sufficient statistics for alinear combiner, which prove ineffective due to the interferers frequencycharacteristics, are modified to yield improved detectionunder partial jamming in the spectral domain. Robustness to partialtime jamming is achieved by extending the notion of replicasover the frequency axis to a repetition over the time variable. Analysisand simulations are provided, showing the advantages of usingFDSS with spatial diversity to combat the interference when it isconfined to a narrow frequency band or short time interval relativeto the desired signal extent in either domain.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The semiarid rainfall regime is northeastern Brazil is highly variable. Climate processes associated with rainfall are complex and their effects may represent extreme situations of drought or floods, which can have adverse effects on society and the environment. The regional economy has a significant agricultural component, which is strongly influenced by weather conditions. Maximum precipitation analysis is traditionally performed using the intensity-duration-frequency (IDF) probabilistic approach. Results from such analysis are typically used in engineering projects involving hydraulic structures such as drainage network systems and road structures. On the other hand, precipitation data analysis may require the adoption of some kind of event identification criteria. The minimum inter-event duration (IMEE) is one of the most used criteria. This study aims to analyze the effect of the IMEE on the obtained rain event properties. For this purpose, a nine-year precipitation time series (2002- 2011) was used. This data was obtained from an automatic raingauge station, installed in an environmentally protected area, Ecological Seridó Station. The results showed that adopted IMEE values has an important effect on the number of events, duration, event height, mean rainfall rate and mean inter-event duration. Furthermore, a higher occurrence of extreme events was observed for small IMEE values. Most events showed average rainfall intensity higher than 2 mm.h-1 regardless of IMEE. The storm coefficient of advance was, in most cases, within the first quartile of the event, regardless of the IMEE value. Time series analysis using partial time series made it possible to adjust the IDF equations to local characteristics

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Time correlation functions of current fluctuations were calculated by molecular dynamics (MD) simulations in order to investigate sound waves of high wavevectors in the glass-forming liquid Ca(NO3)(2)center dot 4H(2)O. Dispersion curves, omega(k), were obtained for longitudinal (LA) and transverse acoustic (TA) modes, and also for longitudinal optic (LO) modes. Spectra of LA modes calculated by MD simulations were modeled by a viscoelastic model within the memory function framework. The viscoelastic model is used to rationalize the change of slope taking place at k similar to 0.3 angstrom(-1) in the omega(k) curve of acoustic modes. For still larger wavevectors, mixing of acoustic and optic modes is observed. Partial time correlation functions of longitudinal mass currents were calculated separately for the ions and the water molecules. The wavevector dependence of excitation energies of the corresponding partial LA modes indicates the coexistence of a relatively stiff subsystem made of cations and anions, and a softer subsystem made of water molecules. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4751548]

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El presente estudio analizó los efectos de un entrenamiento pliométrico y de un entrenamiento resistido mediante arrastres de trineo de 8 semanas de duración sobre el rendimiento en pruebas de salto vertical (SJ y CMJ) y velocidad en esprint de 30 metros (tiempo parcial en 10m) en futbolistas amateurs. El estudio incluyó dos grupos experimentales que realizaron uno de los dos métodos de entrenamiento y un grupo de control. Participaron en el diseño final 26 jugadores de futbol con una media de edad de 21,38 ± 2,53 años, una altura media de 177,22 ± 6,19 cm y una media de peso corporal de 78,78 ± 12,13 kg. El programa de entrenamiento constaba de dos días de entrenamiento para los grupos de pliometría y entrenamiento resistido respectivamente, que realizaron durante 8 semanas consecutivas con una carga diferente entre las 4 primeras semanas y las 4 últimas aumentando el peso en el trineo de arrastre y la altura y distancia entre vallas. El análisis estadístico no muestra diferencias significativas entre grupos después de las 8 semanas de entrenamiento, sin embargo, en el análisis descriptivo si se aprecian cambios positivos a nivel de rendimiento tanto en salto vertical como en el esprint.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper investigates the effect of time offset errors on the partial parallel interference canceller (PIC) and compares the performance of it against that of the standard PIC. The BER performances of the standard and partial interference cancellers are simulated in a near far environment with varying time offset errors. These simulations indicate that whilst timing errors significantly affect the performance of both these schemes, they do not diminish the gains that are realised by the partial PIC over that of the standard PIC.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Modern age samples from various depositional environments were examined for signal resetting. For 19 modern aeolian/beach samples all De values obtained were View the MathML source, with ∼70% having View the MathML source. For 21 fluvial/colluvial samples, all De values were View the MathML source with ∼80% being View the MathML source. De as a function of illumination (OSL measurement) time (De(t)) plots were examined for all samples. Based on previous laboratory experiments, increases in De(t) were expected for partially reset samples, and constant De(t) for fully reset samples. All aeolian samples, both modern age and additional ‘young’ samples (<1000 years), showed constant (flat) De(t) while all modern, non-zero De, fluvial/colluvial samples showed increasing De(t). ‘Replacement plots’, where a regenerated signal is substituted for the natural, yielded constant (flat) De(t). These findings support strongly the use of De(t) as a method of identifying incomplete resetting in fluvial samples. Potential complicating factors, such as illumination (bleaching) spectrum, thermal instability and component composition are discussed and a series of internal checks on the applicability of the De(t) for each individual aliquot/grain level are outlined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The exact time-dependent solution for the stochastic equations governing the behavior of a binary self-regulating gene is presented. Using the generating function technique to rephrase the master equations in terms of partial differential equations, we show that the model is totally integrable and the analytical solutions are the celebrated confluent Heun functions. Self-regulation plays a major role in the control of gene expression, and it is remarkable that such a microscopic model is completely integrable in terms of well-known complex functions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies a nonlinear, discrete-time matrix system arising in the stability analysis of Kalman filters. These systems present an internal coupling between the state components that gives rise to complex dynamic behavior. The problem of partial stability, which requires that a specific component of the state of the system converge exponentially, is studied and solved. The convergent state component is strongly linked with the behavior of Kalman filters, since it can be used to provide bounds for the error covariance matrix under uncertainties in the noise measurements. We exploit the special features of the system-mainly the connections with linear systems-to obtain an algebraic test for partial stability. Finally, motivated by applications in which polynomial divergence of the estimates is acceptable, we study and solve a partial semistability problem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A procedure for partial digestion of bovine tissue is proposed using polytetrafluoroethylene (PTFE) microvessels inside a baby-bottle sterilizer under microwave radiation for multi-element determination by inductively coupled plasma optical emission spectrometry (ICP OES). Samples were directly weighed in laboratory-made polytetrafluoroethylene vessels. Nitric acid and hydrogen peroxide were added to the uncovered vessels, which were positioned inside the baby-bottle sterilizer, containing 500 mL of water. The hydrogen peroxide volume was fixed at 100 mu L The system was placed in a domestic microwave oven and partial digestion was carried out for the determination of Ca, Cu, Fe. Mg, Mn and Zn by inductively coupled plasma optical emission spectrometry. The single-vessel approach was used in the entire procedure, to minimize contamination in trace analysis. Better recoveries and lower residual carbon content (RCC) levels were obtained under the conditions established through a 2(4-1) fractional factorial design: 650 W microwave power, 7 min digestion time, 50 mu L nitric acid and 50 mg sample mass. The digestion efficiency was ascertained according to the residual carbon content determined by inductively coupled plasma optical emission spectrometry. The accuracy of the proposed procedure was checked against two certified reference materials. (C) 2009 Elsevier B.V. All rights reserved.