264 resultados para PWM
Resumo:
The flying capacitor multicell inverter (FCMI) possesses natural balancing property. With the phase-shifted (PS) carrier-based scheme, natural balancing can be achieved in a straightforward manner. However, to achieve natural balancing with the harmonically optimal phase-disposition (PD) carrierbased scheme, the conventional approaches require (n-1) x (n-1) trapezoidal carrier signals for an n-level inverter, which is (n-1) x (n-2) times more than that in the standard PD scheme. This paper proposes two improved natural balancing strategies for FMI under PD scheme, which use the same (n-1) carrier signals as used in the standard PD scheme. In the first scheme, on-line detection is performed of the band in which the modulation signal is located, corresponding period number of the carrier, and rising or falling half cycle of the carrier waveform to generate the switching signals based on certain rules. In the second strategy, the output voltage level selection is first processed and the switching signals are then generated according to a rule based on preferential cell selection algorithm. These methods are easy to use and can be simply implemented as compared to the other available methods. Simulation and experimental results are presented for a five-level inverter to verify these proposed schemes.
Resumo:
For dynamic closed loop control of a multilevel converter with a low pulse number (ratio of switching frequency to synthesized fundamental), natural sampled pulse-width modulation (PWM) is the best form of modulation. Natural sampling does not introduce distortion or a delayed response to the modulating signal. However previous natural sampled PWM implementations have generally been analog. For a modular multilevel converter, a digital implementation has advantages of accuracy and flexibility. Re-sampled uniform PWM is a novel digital modulation technique which approaches the performance of natural PWM. Both hardware and software implementations for a five level multilevel converter phase are presented, demonstrating the improvement over uniform PWM.
Resumo:
An alternative approach to digital PWM generation using an adder rather than a counter is presented. This offers several advantages. The resolution and gain of the pulse width modulator remain constant regardless of the module clock frequency and PWM output frequency. The PWM resolution also becomes fixed at the register width. Even at high PWM frequencies, the resolution remains high when averaged over a number of PWM cycles. An inherent dithering of the PWM waveform introduced over successive cycles blurs the switching spectra without distorting the modulating waveform. The technique also lends itself to easily generating several phase shifted PWM waveforms suitable for multilevel converter modulation.
Resumo:
For dynamic closed loop control of a multilevel converter with a low switching frequency, natural sampled PWM is the best form of modulation. However previous natural sampled PWM implementations have generally been analog. A digital implementation has advantages, particularly for a multilevel converter. Re-sampled uniform PWM, a modulation technique which approaches the performance of natural PWM, is implemented both in software and hardware. Results demonstrating the improvement over uniformPWM techniques are presented.
Resumo:
A pulsewidth modulation (PWM) technique is proposed for minimizing the rms torque ripple in inverter-fed induction motor drives subject to a given average switching frequency of the inverter. The proposed PWM technique is a combination of optimal continuous modulation and discontinuous modulation. The proposed technique is evaluated both theoretically as well as experimentally and is compared with well-known PWM techniques. It is shown that the proposed method reduces the rms torque ripple by about 30% at the rated speed of the motor drive, compared to conventional space vector PWM.
Resumo:
Thyristor forced commutated AC/DC convertors are useful for improving the power factor and waveform of AC-side line current. These are controlled through pulse-width modulation schemes for best performance. However, the 3-phase versions impose restrictions on the PWM strategies that can be implemented for excellent harmonic rejection. This paper presents new PWM control strategies for the 3-phase converters and compares them along with the conventional 4-pulse PWM strategy for harmonic elimination. Finally, two new PWM strategies are shown to be the best, for which oscillograms are presented from actual implementation.
Resumo:
This paper proposes a multilevel inverter configuration which produces a hexagonal voltage space vector structure in the lower modulation region and a 12-sided polygonal space vector structure in the overmodulation region. A conventional multilevel inverter produces 6n plusmn 1 (n = odd) harmonics in the phase voltage during overmodulation and in the extreme square-wave mode of operation. However, this inverter produces a 12-sided polygonal space vector location, leading to the elimination of 6n plusmn 1 (n = odd) harmonics in the overmodulation region extending to a final 12-step mode of operation with a smooth transition. The benefits of this arrangement are lower losses and reduced torque pulsation in an induction motor drive fed from this converter at higher modulation indexes. The inverter is fabricated by using three conventional cascaded two-level inverters with asymmetric dc-bus voltages. A comparative simulation study of the harmonic distortion in the phase voltage and associated losses in conventional multilevel inverters and that of the proposed inverter is presented in this paper. Experimental validation on a prototype shows that the proposed converter is suitable for high-power applications because of low harmonic distortion and low losses.
Resumo:
A new three-phase current source inverter topology is presented, consisting of three single-phase bridge inverters connected in series and feeding the isolated windings of a standard three-phase induction motor. Because a current zero in one phase now does not affect the others, it enables the implementation of a wide range of current PWM patterns for the reduction and selective elimination of torque pulsations. Furthermore, this system allows for very fast control of the fundamental load current through the use of sinusoidal PWM, a method that was not possible to implement on existing inverter topologies.
Resumo:
A new current pulsewidth modulation (PWM) method is presented which uses the principle of creating zero three-phase currents at selected instants of time, through which the load current harmonic content can be controlled along with the magnitude of its fundamental content. This gives rise to reduction of motor torque ripples through the selection of suitable PWM patterns and a fast current control in the inverter by varying the pulsewidths of the PWM pattern. Under this new PWM mode of operation, the autosequentially commutated inverter (ASCI) circuit can be modified easily so that a higher number of pulses can be accomodated within a half-cycle, compared to the normal ASCI circuit. The experimental oscillograms verify the effectiveness of the new PWM method.
Resumo:
he performance of an induction motor fed by PWM inverters is mainly determined by the harmonic contents of the output voltage. This paper presents a method of numerically calculating the harmonics in the output voltage waveform. Equal pulse-width modulation and siunsoidal PWM are studied. Analysis has been done for single-phase and three-phase bridge inverters. A systematic procedure is given for computing the harmonics and the results are. tabulated.
Resumo:
The implementation of three-phase sinusoidal pulse-width-modulated inverter control strategy using microprocessor is discussed in this paper. To save CPU time, the DMA technique is used for transferring the switching pattern from memory to the pulse amplifier and isolation circuits of individual thyristors in the inverter bridge. The method of controlling both voltage and frequency is discussed here.
Resumo:
The implementation of three-phase sinusoidal pulse-width-modulated inverter control strategy using microprocessor is discussed in this paper. To save CPU time, the DMA technique is used for transferring the switching pattern from memory to the pulse amplifier and isolation circuits of individual thyristors in the inverter bridge. The method of controlling both voltage and frequency is discussed here.
Resumo:
Special switching sequences can be employed in space-vector-based generation of pulsewidth-modulated (PWM) waveforms for voltage-source inverters. These sequences involve switching a phase twice, switching the second phase once, and clamping the third phase in a subcycle. Advanced bus-clamping PWM (ABCPWM) techniques have been proposed recently that employ such switching sequences. This letter studies the spectral properties of the waveforms produced by these PWM techniques. Further, analytical closed-form expressions are derived for the total rms harmonic distortion due to these techniques. It is shown that the ABCPWM techniques lead to lower distortion than conventional space vector PWM and discontinuous PWM at higher modulation indexes. The findings are validated on a 2.2-kW constant $V/f$ induction motor drive and also on a 100-kW motor drive.