28 resultados para POLAROGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The differential pulse polarographic behaviour of cinnamic acid was studied in acetate and phosphate buffer solutions (pH 3.5-7.5). The reduction mechanism is discussed. The drug can be determined at pH 5.0 over the concentration range 5 X 10(-5)-1 X 10(-3) mol l(-1). The effect of tetraalkylammonium salts on the electroanalytical determination of cinnamic acid was investigated, the direct determination of the drug (0.7-5.5 mu g ml(-1)) in urine samples diluted with acetate buffer (pH 5.0) can be effected in the presence of 1 x 10(-3) mol l(-1) cetyldimethylethylammonium bromide solution. The detection limit was found to be 0.1 mu g ml(-1). The relative standard deviation from six determinations at the 5.5 mu g ml(-1) level was 1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"May 6, 1954."

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The sample under investigation in this project is an experimental chromium enriched yeast used as a possible additive in animal foodstuff, which was produced by growing yeast in the presence of chromium (III) chloride. Chromium on its own in not biologically active but chromium in the form of chromium enriched yeast is biologically active. The objective of this project was to show the complete absence of chromium(VI) from the sample. A literature survey describing previous work carried out on the speciation of Cr(VI) has been carried out. The principal methods of detection of Cr(VI) used in this project are Polarography, G.F.A.A. Spectroscopy, U.V. Spectroscopy and H.P.L.C. For each of the above methods a calibration curve was obtained and each method was applied to the yeast extract. The H.P.L.C. and U.V. spectroscopic method are specific for Cr(VI) but polarography and G.F.A.A. spectroscopy measure total chromium. Tris-NaOH buffer has been investigated for the extraction of chromium(VT). Problems associated with air oxidation of Cr(III) in alkaline solution have identified and procedures described for the suppression of air oxidation. Procedures are described for the application of the extraction procedure to the yeast extract and for the determination of Cr(VI) in the extract. Procedures are also described for the preconcentration of Cr(VI) on a HPLC column and for the application to the yeast extract. The rate of reduction of Cr(VI) by ascorbic acid is investigated and found to be first order with respect to ascorbic acid concentration. The reduction capacity of the yeast is also investigated and it was found that in acid solution the yeast will reduce Cr(VI) but in neutral or basic solution the reduction capacity is diminished. Conclusions regarding the objectives of the project are drawn and suggestions for further work are given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A differential pulse polarographic study with the objective to determine iron (III) in presense of copper (II) in a supporting electrolyte based on citrate - EDTA was made. The best experimental conditions found were a supporting electrolyte of citrate 0.25 mol L-1, EDTA 0.050 mol L-1 and KNO3 0.50 mol L-1, pH 5.00. In this media iron (III) showed a polarographic peak in -0.08 V and the copper (II) in -0.34 V, both vs. Ag/AgCl (saturated KCl). Thus, a analytical method was developed and applied to determine iron (III) in brass alloy, a matrix were copper is in large excess over iron. The results obtained showed no interference of copper in the iron determination. The value of 0.21% of iron in the sample alloy composition was obtained and the method was validated by atomic absortion and recovery test, and the results exhibited a good agreement with the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper provides a review on voltammetric and polarographic methods for the speciation analysis of inorganic and organic arsenic compounds in different matrices. A discussion on the main advantages of electroanalytical methods in comparison with other analytical methods employed for arsenic speciation is presented. The mechanistic aspects of the most relevant techniques employing cathodic and anodic stripping voltammetry as well as polarographic methods published in the last twenty five years are summarized and discussed. The bibliographic references cited in this work were selected from the Web of Science (published by the ISI) and the main journals of analytical chemistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stability constant (log beta) and thermodynamic parameters of Cd2+ complexes with sulfonamide and cephapirin were determined by Polarographic technique at pH = 7.30 ± 0.01 and µ = 1.0 M KNO3 at 250°C. The sulfonamides were sulfadiazine, sulfisoxazole, sulfamethaxazole, sulfamethazine, sulfathiazole, sulfacetamide and sulfanilamide used as primary ligands and cephapirin as secondary ligand. Cd2+ formed 1:1:1, 1:2:1 and 1:1:2 complexes. The nature of electrode processes were reversible and diffusion controlled. The stability constants and thermodynamic parameters (deltaG, deltaH and deltaS) were determined. The formation of the metal complexes has been found to be spontaneous, exothermic in nature, and entropically unfavourable at higher temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clotrimazole was shown to react at room temperature in Britton Robinson buffer pH 2 with the reactive dye Procion Red HE-3B. The product exhibited a differential pulse polarographic peak at -0.38 V, which was well separated from the peaks of the reactive dye at -0.08, -0.80 and -0.95 V, and this allowed the indirect determination of clotrimazole in the presence of excess of the reactive dye. The method has been applied satisfactorily to the determination of clotrimazole in pharmaceutical formulations, calibration graphs are rectilinear up to at least 40 mug ml(-1). The detection limit was calculated to be 2.6 mug ml(-1) (3 sigma). (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ceftazidime shows two main polarographic reduction peaks at pH 4.0, that at -0.45 V owing to reduction of the C=N bond in the methylethoxyimino group and that at -1.00 V owing to the reductive elimination of pyridine: the first peak is particularly suitable for the determination of ceftazidime. Ceftazidime can also be determined indirectly using the tensammetric peak at -0.60 V (in Britton-Robinson buffer pH 9.5) of pyridine liberated on hydrolysis. Ceftazidime can be determined in urine using the direct method only after Cls solid phase extraction, but it can be determined directly in the urine by hydrolysing it and using the pyridine peak. (C) 1997 Elsevier B.V. B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cefaclor is not reducible at a mercury electrode, but it can be determined polarographically and by cathodic stripping voltammetry as its initial alkaline degradation product which is obtained in high yield by hydrolysis of cefaclor in Britton-Robinson (B-R) buffer pH 10 at 50 degrees C for 30 min (reduction peak at pH 10, -0.70 V). Differential pulse polarographic calibration graphs are linear up to at least 1 x 10(-4) mol l(-1). Recoveries of 93% of the cefaclor (n = 3) were obtained from urine spiked with 38.6 mu g ml(-1) using this polarographic method with 1 ml urine made up to 10 ml with pH 10 buffer. Using cathodic stripping voltammetry and accumulating at a hanging mercury drop electrode at -0.2 V for 30 s, linear calibration graphs were obtained from 0.35 to 40 mu g ml(-1) cefaclor in B-R buffer pH 10. A relative standard deviation of 4.2% (eta = 5) was obtained, and the limit of detection was calculated to be 2.9 ng ml(-1). Direct determination of cefaclor in human urine (1 ml of urine was made up to 10 ml with pH 10 buffer) spiked to 0.39 mu g ml(-1) was made (recovery 98.6%). (C) 1999 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical reduction of two reactive dyes: Procion Red HE-3B 9 (RR120) and Procion Green HE-4BD (RG19) was investigated using cyclic voltammetry, differential pulse and DC, polarography, chronoamperometry and controlled potential electrolysis at mercury electrodes. The bis-azo groups of the RR120 dye are reduced together in one single step of four electrons, the bis-azo groups of the RG19 dye are reduced in two steps owing to the difference in the electron densities promoted by the different substituents in the benzene rings adjacent to the azo groups. The bis-monochlorotriazine reactive groups in both dyes are reduced only in acidic medium in their protonated form, leading to the reduction of the triazine groups. The reduction mechanism of both reactive dyes is discussed. Both dyes can be quantified in aqueous medium by differential pulse polarography in the concentration range of 1 x 10(-7) mol L-1 to 1 x 10(-5) mol L-1 by monitoring the reduction of the chromophore group or the reactive group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The reduction process of the azo dyes reactive red 120 and reactive green 19 was investigated in B-R buffer pH 2-12 by differential pulse polarography, cyclic voltammetry and controlled potential electrolyse. The reactive red 120 presents two azo groups reducible in a single step of 8 electrons followed by simultaneous reduction of the two clorotriazine groups. The reduction of reactive green 19 is complicated by the presence of azo groups and chlorotriazine moyeties in a non symmetrical molecule. The peaks can be monitored for dyes determination in concentration level up to 1x10(-7) mol/L and 1x10(-9) mol/L using differential pulse polarography or cathodic stripping voltammetry.