940 resultados para PA chest X-ray
Resumo:
Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.
Resumo:
Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.
Resumo:
Pericardial cysts are rare benign congenital malformations, usually small, asymptomatic and detected incidentally on chest X-ray as a mass located in the right costophrenic angle. Giant pericardial cysts are very uncommon and produce symptoms by compressing adjacent structures. In this report, the authors present a case of a symptomatic giant pericardial cyst incorrectly diagnosed as dextrocardia on chest X-ray.
Resumo:
Summary : Aim: To assess the number of immigrants with pulmonary tuberculosis detected by chest x-ray screening at the Swiss border. Method: All adult immigrants entering Switzerland in 2004 were screened by chest x-ray (CXR). The number of radiological abnormalities suggestive of pulmonary tuberculosis, and the proportion requiring treatment for tuberculosis, were assessed retrospectively. The frequency of symptoms among immigrants with documented TB was compared with a sample of immigrants with a normal CXR. Results: Among 8995 immigrants, 8240 had a normal CXR, 630 had some abnormality not suggestive of active TB and 125 (1.4%) had a CXR suggestive of pulmonary TB. A final diagnosis of tuberculosis requiring treatment was made in SO (1 l with positive smear and culture, 16 with positive culture and 23 with negative culture), 57 had fibrotic lesions and 18 had another disease or a normal x-ray on control. The prevalence of symptoms did not differ between 27 immigrants with documented TB (smear+/culture+: 82%, smear-/ culture+: 75%), and 23 with smear-/culturetuberculosis (91%), but lower in 57 immigrants with fibrotic lesions (60%). Cough was more frequent among the 27 immigrants with documented TB (70%) than among 198 smokers without TB (37%) and among 229 non-smokers without TB (15%) Conclusions: Only 22% (27/125) of immigrants with CXR abnormalities suggestive of pulrnonary tuberculosis were documented by smear and/or culture and 40% (50/125) needed antituberculous treatment. 2/11 smear-positive immigrants would not have been detected by a questionnaire on symptoms. Rapport de synthèse : Le but de l'étude est d'évaluer le rendement du dépistage radiologique de la tuberculose pulmonaire chez les immigrés à l'entrée en Suisse. Méthode: parmi les immigrés adultes entrés en Suisse en 2004, qui ont tous passé un contrôle radiologique, le nombre de porteurs de clichés thoraciques suspects de tuberculose et la proportion de cas chez lesquels un traitement antituberculeux a été prescrit ont été évalués rétrospectivement. La fréquence des symptômes chez les immigrés atteints de tuberculose a été comparée à celle d'un groupe contrôle sans tuberculose. Résultats: parmi 8995 immigrés, 8240 avaient un cliché thoracique normal, 630 étaient porteurs d'une anomalie non suspecte de tuberculose active et 125 (1.4%) montraient des signes radiologiques suspects de tuberculose. Un diagnostic final de tuberculose nécessitant un traitement a été posé dans 50 cas (11 cas à frottis et culture positifs, 16 cas à culture positive, 23 cas à culture négative), 57 présentaient des lésions cicatricielles compatibles avec une ancienne tuberculose et 18 avaient une autre affection pulmonaire ou un cliché normal au contrôle. La prévalence des plaintes n'était pas différente entre les 27 immigrés porteurs d'une tuberculose documentée (frottis+ /culture+: 82%, frottis-/culture+ : 75%) et les 23 immigrés atteints d'une tuberculose non documentée (frottis-/culture-: 91%), mais elle était plus élevée que chez les 57 immigrés porteurs de lésions cicatricielles (59%). La toux était plus fréquente chez les 27 tuberculeux documentés (70%) que chez 198 fumeurs sans tuberculose (37%) et chez 229 non fumeurs sans tuberculose (15%). Conclusions: seuls 22% (27/125) des immigrés dont le cliché thoracique est suspect de tuberculose sont porteurs d'une tuberculose documentée par examen direct ou culture et 40% (50/125) nécessitent un traitement antituberculeux. Deux immigrants sur les 11 cas frottis positifs n'auraient pas été dépistés par un questionnaire.
Resumo:
Rapid response to : Madan M Rehani and Manorma Berry Radiation doses in computed tomography BMJ 2000; 320: 593-594
Resumo:
Purpose - To develop and validate a psychometric scale for assessing image quality perception for chest X-ray images. Methods - Bandura's theory was used to guide scale development. A review of the literature was undertaken to identify items/factors which could be used to evaluate image quality using a perceptual approach. A draft scale was then created (22 items) and presented to a focus group (student and qualified radiographers). Within the focus group the draft scale was discussed and modified. A series of seven postero-anterior chest images were generated using a phantom with a range of image qualities. Image quality perception was confirmed for the seven images using signal-to-noise ratio (SNR 17.2–36.5). Participants (student and qualified radiographers and radiology trainees) were then invited to independently score each of the seven images using the draft image quality perception scale. Cronbach alpha was used to test interval reliability. Results - Fifty three participants used the scale to grade image quality perception on each of the seven images. Aggregated mean scale score increased with increasing SNR from 42.1 to 87.7 (r = 0.98, P < 0.001). For each of the 22 individual scale items there was clear differentiation of low, mid and high quality images. A Cronbach alpha coefficient of >0.7 was obtained across each of the seven images. Conclusion - This study represents the first development of a chest image quality perception scale based on Bandura's theory. There was excellent correlation between the image quality perception scores derived using the scale and the SNR. Further research will involve a more detailed item and factor analysis.
Resumo:
OBJECTIVES: The aim of this phantom study was to evaluate the contrast-to-noise ratio (CNR) in pulmonary computed tomography (CT)-angiography for 300 and 400 mg iodine/mL contrast media using variable x-ray tube parameters and patient sizes. We also analyzed the possible strategies of dose reduction in patients with different sizes. MATERIALS AND METHODS: The segmental pulmonary arteries were simulated by plastic tubes filled with 1:30 diluted solutions of 300 and 400 mg iodine/mL contrast media in a chest phantom mimicking thick, intermediate, and thin patients. Volume scanning was done with a CT scanner at 80, 100, 120, and 140 kVp. Tube current-time products (mAs) varied between 50 and 120% of the optimal value given by the built-in automatic dose optimization protocol. Attenuation values and CNR for both contrast media were evaluated and compared with the volume CT dose index (CTDI(vol)). Figure of merit, calculated as CNR/CTDIvol, was used to quantify image quality improvement per exposure risk to the patient. RESULTS: Attenuation of iodinated contrast media increased both with decreasing tube voltage and patient size. A CTDIvol reduction by 44% was achieved in the thin phantom with the use of 80 instead of 140 kVp without deterioration of CNR. Figure of merit correlated with kVp in the thin phantom (r = -0.897 to -0.999; P < 0.05) but not in the intermediate and thick phantoms (P = 0.09-0.71), reflecting a decreasing benefit of tube voltage reduction on image quality as the thickness of the phantom increased. Compared with the 300 mg iodine/mL concentration, the same CNR for 400 mg iodine/mL contrast medium was achieved at a lower CTDIvol by 18 to 40%, depending on phantom size and applied tube voltage. CONCLUSIONS: Low kVp protocols for pulmonary embolism are potentially advantageous especially in thin and, to a lesser extent, in intermediate patients. Thin patients profit from low voltage protocols preserving a good CNR at a lower exposure. The use of 80 kVp in obese patients may be problematic because of the limitation of the tube current available, reduced CNR, and high skin dose. The high CNR of the 400 mg iodine/mL contrast medium together with lower tube energy and/or current can be used for exposure reduction.
Resumo:
The pentadentate H(3)bhci [1,3,5-trideoxy-1,3-bis((2-hydroxybenzyl)amino)-cis-inistol] and its bifunctionalized analogue H(3)bhci-glu-H [1,3,5-trideoxy-1,3-bis((2-hydroxybenzyl)amino)-5-glutaramido-cis-inositol] were synthesized, and their coordination chemistry was investigated with inactive rhenium, with no carrier added Re-188 and with carrier added Re-186. The neutral Re(V) complexes [ReO-(bhci)] and [ReO(bhci-glu-H)] are formed in good yields starting from [ReOCl3(P(C6H5)(3))(2)] or in quantitative yield directly from [(ReO4)-Re-186/188](-) in aqueous solution by reduction with Sn(II) or Sn(0). The X-ray structures of [ReO(bhci)] and [ReO(bhci-glu-H)] were elucidated revealing pentadentate side on coordination of the ligands to the Re=O core. The basic cyclohexane frame adopts a chair form in the case of [ReO(bhci)] and a twisted boat form in the case of [ReO(bhci-glu-H)]. [ReO(bhci)] crystallizes in the monoclinic space group C2/c with a = 27.425(3), b = 14.185(1), c = 19.047(2) Angstrom, and beta = 103.64(2)degrees and [ReO(bhci-glu-H)] in the monoclinic space group P2(1)/c with a = 13.056(3), b = 10.180(1), c = 22.378(5) Angstrom and beta = 98.205(9)degrees Both Re-188 complexes are stable in human serum for at least 3 days without decomposition. After injection into mice, [ReO(bhci-glu)](-) is readily excreted through the intestines, while [ReO(bhci)] is excreted by intestines, liver, and the kidneys. TLC investigations of the urine showed exclusively the complexes [ReO(bhci-glu-H)] and [ReO(bhci)], respectively, and no decomposition products. For derivatization of antibodies, the carboxylic group of [ReO(bhci-glu-H)] was activated with N-hydroxysuccinimide, which required unusually vigorous reaction conditions (heating). The anti colon cancer antibody mAb-35 [IgG and F(ab')(2) fragment] was labeled with [(ReO)-Re-186/188(bhci-glu)] to a specific activity of up to 1.5 mCi/mg (55 MBq/mg) with full retention of immunoreactivity. Labeling yields followed pseudo-first-order kinetics in antibody concentration with the ratio of rates between aminolysis and hydrolysis being about 2. Biodistributions of Re-186-labeled intact mAb-35 as well as of its F(ab')(2) fragment in tumor-bearing nude mice revealed good uptake by the tumor with only low accumulation of radioactivity in normal tissue.
Resumo:
This article reports on a-Si:H-based low-leakage blue-enhanced photodiodes for dual-screen x-ray imaging detectors. Doped nanocrystalline silicon was incorporated in both the n- and p-type regions to reduce absorption losses for light incoming from the top and bottom screens. The photodiode exhibits a dark current density of 900 pA/cm(2) and an external quantum efficiency up to 90% at a reverse bias of 5 V. In the case of illumination through the tailored p-layer, the quantum efficiency of 60% at a 400 nm wavelength is almost double that for the conventional a-Si:H n-i-p photodiode.
Resumo:
The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.
Resumo:
Angiogenesis inhibitors have gained much public attention recently as anti-cancer agents and several are currently in clinical trials, including angiostatin (Phase I, Thomas Jefferson University Hospital, Philadelphia, PA). We report here the bowl-shaped structure of angiostatin kringles 1-3, the first multi-kringle structure to be determined. All three kringle lysine-binding sites contain a bound bicine molecule of crystallization while the former of kringle 2 and kringle 3 are cofacial. Moreover, the separation of the kringle 2 and kringle 3 lysiner binding sites is sufficient to accommodate the a-helix of the 30 residue pepticle VEK-30 found in the kringle 2/VEK-30 complex. Together the three kringles produce a central cavity suggestive of a unique domain where they may function in concert. (C) 2002 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Al fine di migliorare le tecniche di coltura cellulare in vitro, sistemi a bioreattore sono sempre maggiormente utilizzati, e.g. ingegnerizzazione del tessuto osseo. Spinner Flasks, bioreattori rotanti e sistemi a perfusione di flusso sono oggi utilizzati e ogni sistema ha vantaggi e svantaggi. Questo lavoro descrive lo sviluppo di un semplice bioreattore a perfusione ed i risultati della metodologia di valutazione impiegata, basata su analisi μCT a raggi-X e tecniche di modellizzazione 3D. Un semplice bioreattore con generatore di flusso ad elica è stato progettato e costruito con l'obiettivo di migliorare la differenziazione di cellule staminali mesenchimali, provenienti da embrioni umani (HES-MP); le cellule sono state seminate su scaffold porosi di titanio che garantiscono una migliore adesione della matrice mineralizzata. Attraverso un microcontrollore e un'interfaccia grafica, il bioreattore genera tre tipi di flusso: in avanti (senso orario), indietro (senso antiorario) e una modalità a impulsi (avanti e indietro). Un semplice modello è stato realizzato per stimare la pressione generata dal flusso negli scaffolds (3•10-2 Pa). Sono stati comparati tre scaffolds in coltura statica e tre all’interno del bioreattore. Questi sono stati incubati per 21 giorni, fissati in paraformaldehyde (4% w/v) e sono stati soggetti ad acquisizione attraverso μCT a raggi-X. Le immagini ottenute sono state poi elaborate mediante un software di imaging 3D; è stato effettuato un sezionamento “virtuale” degli scaffolds, al fine di ottenere la distribuzione del gradiente dei valori di grigio di campioni estratti dalla superficie e dall’interno di essi. Tale distribuzione serve per distinguere le varie componenti presenti nelle immagini; in questo caso gli scaffolds dall’ipotetica matrice cellulare. I risultati mostrano che sia sulla superficie che internamente agli scaffolds, mantenuti nel bioreattore, è presente una maggiore densità dei gradienti dei valori di grigio ciò suggerisce un migliore deposito della matrice mineralizzata. Gli insegnamenti provenienti dalla realizzazione di questo bioreattore saranno utilizzati per progettare una nuova versione che renderà possibile l’analisi di più di 20 scaffolds contemporaneamente, permettendo un’ulteriore analisi della qualità della differenziazione usando metodologie molecolari ed istochimiche.
Resumo:
The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.
Resumo:
X-ray computed tomography (CT) using phase contrast can provide images with greatly enhanced soft-tissue contrast in comparison to conventional attenuation-based CT. We report on the first scan of a human specimen recorded with a phase-contrast CT system based on an x-ray grating interferometer and a conventional x-ray tube source. Feasibility and potential applications of preclinical and clinical phase-contrast CT are discussed.