32 resultados para Oximeter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Summarised retinal vessel diameters are linked to systemic vascular pathology. Monochromatic images provide best contrast to measure vessel calibres. However, when obtaining images with a dual wavelength oximeter the red-free image can be extracted as the green channel information only which in turn will reduce the number of photographs taken at a given time. This will reduce patient exposure to the camera flash and could provide sufficient quality images to reliably measure vessel calibres. Methods: We obtained retinal images of one eye of 45 healthy participants. Central retinal arteriolar and central retinal venular equivalents (CRAE and CRVE, respectively) were measured using semi-automated software from two monochromatic images: one taken with a red-free filter and one extracted from the green channel of a dual wavelength oximetry image. Results: Participants were aged between 21 and 62 years, all were normotensive (SBP: 115 (12) mmHg; DBP: 72 (10) mmHg) and had normal intra-ocular pressures (12 (3) mmHg). Bland-Altman analysis revealed good agreement of CRAE and CRVE as obtained from both images (mean bias CRAE = 0.88; CRVE = 2.82). Conclusions: Summarised retinal vessel calibre measurements obtained from oximetry images are in good agreement to those obtained using red-free photographs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A pretrial clinical improvement project for the BOOST-II UK trial of oxygen saturation targeting revealed an artefact affecting saturation profiles obtained from the Masimo Set Radical pulse oximeter.

METHODS: Saturation was recorded every 10 s for up to 2 weeks in 176 oxygen dependent preterm infants in 35 UK and Irish neonatal units between August 2006 and April 2009 using Masimo SET Radical pulse oximeters. Frequency distributions of % time at each saturation were plotted. An artefact affecting the saturation distribution was found to be attributable to the oximeter's internal calibration algorithm. Revised software was installed and saturation distributions obtained were compared with four other current oximeters in paired studies.

RESULTS: There was a reduction in saturation values of 87-90%. Values above 87% were elevated by up to 2%, giving a relative excess of higher values. The software revision eliminated this, improving the distribution of saturation values. In paired comparisons with four current commercially available oximeters, Masimo oximeters with the revised software returned similar saturation distributions.

CONCLUSIONS: A characteristic of the software algorithm reduces the frequency of saturations of 87-90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter. This effect, which remains within the recommended standards for accuracy, is removed by installing revised software (board firmware V4.8 or higher). Because this observation is likely to influence oxygen targeting, it should be considered in the analysis of the oxygen trial results to maximise their generalisability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Verificar a influência do local de nascimento e do transporte sobre a morbimortalidade de recém-nascidos prematuros na Região Sul do Brasil. MÉTODOS: Estudo de coorte com recém-nascidos prematuros transferidos para a unidade de tratamento intensivo de referência (grupo transporte = 61), tendo sido acompanhados até a alta. Os dados sobre o atendimento no hospital de origem e transporte foram obtidos no momento da internação. Esse grupo foi comparado com neonatos da maternidade de referência, pareados por idade gestacional (grupo controle = 123), tendo como desfecho primário o óbito e desfechos secundários as alterações da glicemia, temperatura e saturação de oxigênio no momento da internação e a incidência de enterocolite necrosante, displasia broncopulmonar e sepses. Na associação entre as variáveis e o desfecho, foi utilizado o risco relativo. Foi adotado um nível de significância de α = 5% e β = 90%. RESULTADOS: A distância média percorrida foi de 91 km. A idade gestacional média foi de 34 semanas. Entre os recém-nascidos transferidos, 23% (n = 14) não tiveram atendimento pediátrico na sala de parto. No transporte, 33% dos recém-nascidos foram acompanhados por pediatra, e os equipamentos utilizados foram: incubadora (57%), bomba de infusão (13%), oxímetro (49%) e aparelho para aferição da glicemia (21%). O grupo transporte apresentou maior incidência de hiperglicemia, risco relativo (RR) = 3,2 (2,3-4,4), hipoglicemia, RR = 2,4 (1,4-4,0), hipertermia, RR = 2,5 (1,6-3,9), e hipoxemia, RR = 2,2 (1,6-3,0). Foram observados 18% de óbitos no grupo dos transferidos e 8,9% no grupo controle, RR = 2,0 (1,0-2,6). CONCLUSÕES: A pesquisa expõe deficiências no atendimento e transporte dos recém-nascidos, sendo necessária uma melhor organização do atendimento perinatal e do transporte na região nordeste do Rio Grande do Sul.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Fisioterapia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia de Eletrónica e Computadores

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pensado en un ámbito de tecnología médica, el propósito principal es el de realizar un seguido de medidas en diferentes partes del cuerpo para establecer unos valores máximos que nos permitan detectar cuando un paciente empieza a padecer estrés. Para ello se necesita un proceso de medición y otro de transmisión de los datos. Es aquí donde aparece el trabajo realizado en el proyecto. “ZigBee aplicado a la transmisión de datos de sensores biomédicos” está pensado para realizar la tarea de transmisión de los datos desde que el sensor realiza la medida hasta que los datos son monitorizados y almacenados. En la memoria del proyecto podremos encontrar el estudio realizado al medio de transmisión inalámbrico utilizado (ZigBee), el análisis del kit eZ430-RF2500 compatible con el medio, y finalmente la implementación del proyecto. Todo este trabajo finalizará con la recepción satisfactoria de los datos medidos por nuestro sensor biomédico (oxímetro) en el aplicativo personal programado con Visual Basic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To test the accuracy of a new pulse oximeter sensor based on transmittance and reflectance. This sensor makes transillumination of tissue unnecessary and allows measurements on the hand, forearm, foot, and lower limb. DESIGN: Prospective, open, nonrandomized criterion standard study. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 54 critically ill neonates (gestational age 27 to 42 wks; postnatal age 1 to 28 days) with arterial catheters in place. MEASUREMENTS AND MAIN RESULTS: A total of 99 comparisons between pulse oximetry and arterial saturation were obtained. Comparison of femoral or umbilical arterial blood with transcutaneous measurements on the lower limb (n = 66) demonstrated an excellent correlation (r2 = .96). The mean difference was +1.44% +/- 3.51 (SD) % (range -11% to +8%). Comparison of the transcutaneous values with the radial artery saturation from the corresponding upper limb (n = 33) revealed a correlation coefficient of 0.94 with a mean error of +0.66% +/- 3.34% (range -6% to +7%). The mean difference between noninvasive and invasive measurements was least with the test sensor on the hand, intermediate on the calf and arm, and greatest on the foot. The mean error and its standard deviation were slightly larger for arterial saturation values < 90% than for values > or = 90%. CONCLUSION: Accurate pulse oximetry saturation can be acquired from the hand, forearm, foot, and calf of critically ill newborns using this new sensor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We evaluated a new pulse oximeter designed to monitor beat-to-beat arterial oxygen saturation (SaO2) and compared the monitored SaO2 with arterial samples measured by co-oximetry. In 40 critically ill children (112 data sets) with a mean age of 3.9 years (range 1 day to 19 years), SaO2 ranged from 57% to 100%, and PaO2 from 27 to 128 mm Hg, heart rates from 85 to 210 beats per minute, hematocrit from 20% to 67%, and fetal hemoglobin levels from 1.3% to 60%; peripheral temperatures varied between 26.5 degrees and 36.5 degrees C. Linear correlation analysis revealed a good agreement between simultaneous pulse oximeter values and both directly measured SaO2 (r = 0.95) and that calculated from measured arterial PaO2 (r = 0.95). The device detected several otherwise unrecognized drops in SaO2 but failed to function in four patients with poor peripheral perfusion secondary to low cardiac output. Simultaneous measurements with a tcPO2 electrode showed a similarly good correlation with PaO22 (r = 0.91), but the differences between the two measurements were much wider (mean 7.1 +/- 10.3 mm Hg, range -14 to +49 mm Hg) than the differences between pulse oximeter SaO2 and measured SaO2 (1.5% +/- 3.5%, range -7.5% to -9%) and were not predictable. We conclude that pulse oximetry is a reliable and accurate noninvasive device for measuring saturation, which because of its rapid response time may be an important advance in monitoring changes in oxygenation and guiding oxygen therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is a participant study, quasi-experimental, of a before and after type. A quantitative approach of biophysiological measures was used, represented by the saturation of oxygen measured by pulse oximeter (SpO2), and recorded on three occasions: before, during and after the bedbath in critically ill patients hospitalized at the ICU of a University Hospital in Brazil. Objective: to compare the SpO2 in various stages of the bath, with and without control of water temperature. Data collection was performed between December 2007 and April 2008 on a convenience sample consisting of 30 patients aged over 18 who had classification in TISS-28 from level II. Results show that water temperature control means a lower variation of SpO2 (p<0.05). No marked differences in variation of saturation between men and women or between age groups were established. In conclusion, heated and constant water temperature during the bedbath is able to minimize the fall of SpO2 that occurs while handling patients during procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Carbon monoxide (CO) poisoning is one of the mostcommon causes of fatal poisoning. Symptoms of CO poisoning arenonspecific and the documentation of elevated carboxyhemoglobin(HbCO) levels in arterial blood sample is the only standard ofconfirming suspected exposure. The treatment of CO poisoning requiresnormobaric or hyperbaric oxygen therapy, according to the symptomsand HbCO levels. A new device, the Rad-57 pulse CO-oximeter allowsnoninvasive transcutaneous measurement of blood carboxyhemoglobinlevel (SpCO) by measurement of light wavelength absorptions.Methods: Prospective cohort study with a sample of patients, admittedbetween October 2008 - March 2009 and October 2009 - March 2010,in the emergency services (ES) of a Swiss regional hospital and aSwiss university hospital (Burn Center). In case of suspected COpoisoning, three successive noninvasive measurements wereperformed, simultaneously with one arterial blood HbCO test. A controlgroup includes patients admitted in the ES for other complaints (cardiacinsufficiency, respiratory distress, acute renal failure), but necessitatingarterial blood testing. Informed consent was obtained from all patients.The primary endpoint was to assess the agreement of themeasurements made by the Rad-57 (SpCO) and the blood levels(HbCO).Results: 50 patients were enrolled, among whom 32 were admittedfor suspected CO poisoning. Baseline demographic and clinicalcharacteristics of patients are presented in table 1. The median age was37.7 ans ± 11.8, 56% being male. Median laboratory carboxyhemoglobinlevels (HbCO) were 4.25% (95% IC 0.6-28.5) for intoxicated patientsand 1.8% (95% IC 1.0-5.3) for control patients. Only five patientspresented with HbCO levels >= 15%. The results disclose relatively faircorrelations between the SpCO levels obtained by the Rad-57 and thestandard HbCO, without any false negative results. However, theRad-57 tend to under-estimate the value of SpCO for patientsintoxicated HbCO levels >10% (fig. 1).Conclusion: Noninvasive transcutaneous measurement of bloodcarboxyhemoglobin level is easy to use. The correlation seems to becorrect for low to moderate levels (<15%). For higher values, weobserve a trend of the Rad-57 to under-estimate the HbCO levels. Apartfrom this potential limitation and a few cases of false-negative resultsdescribed in the literature, the Rad-57 may be useful for initial triageand diagnosis of CO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulse oximetry represents a major advance in patient monitoring, but measurement below 70 to 80% saturation has important limitations. Several authors have tested pulse oximetry at low saturations with conflicting results. A review of these data indicates that every patient with a pulse oximeter value below 75 to 80% SaO2 should have one or more invasive measurements of the arterial SaO2 in order to avoid undetected severe hypoxemia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We tested the hypothesis that hyperoxemia defined as arterial PO2 above 12 kPa can be detected by pulse oximetry using 95% oxygen saturation as the upper limit. Thirty artificially ventilated neonates with an indwelling arterial catheter were studied registrating transcutaneous oxygen saturation (Ohmeda Biox 3700 Pulse Oximeter) and transcutaneous PO2 continuously during a 4-hour period and measuring arterial oxygen saturation and PO2 intermittently. 46 episodes of arterial hyperoxemia were observed. Pulse oximetry had a sensitivity of 30%, detecting 14 of these 46 hyperoxemic episodes, and a specificity of 93%. The accuracy for separating hyperoxemia from normoxemia by pulse oximetry could be improved by shifting the cut-off point from 95% to 92%. With this optimal cut-off point sensitivity was 70% and specificity 62%. We conclude that pulse oximetry is not reliable for detection of hyperoxemia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sleep-disordered breathing (SDB) is underdiagnosed in women, probably due to the different gender-related manifestation. We investigated the differences in presentation, symptoms and co-morbidities of SDB in men and in pre- and postmenopausal women by a clinical, retrospective, cross-sectional study of 601 consecutively referred women and 233 age- and BMI-matched male-female pairs studied with the static-chargesensitive bed (SCSB) and an oximeter. Data on the use of nasal CPAP were gathered from the Paimio hospital database, and the co-morbidity information was based on reimbursed medication data from the National Agency for Medicines and the Social Insurance institution. The abnormal breathing episodes at night were more frequent in men than in women, and in postmenopausal women compared to premenopausal ones. Partial upper airway obstruction was the most common type of SDB in both genders but especially in females. BMI and the major symptoms of SDB were similar in pre- and postmenopausal women, and a menopause effect on symptoms was not found. CPAP adherence did not differ between symptomatic patients with partial upper airway obstruction and those presenting with conventional obstructive sleep apnea. Comorbidities were more frequent in SDB patients than in the general Finnish population. Compared to sleep apnea, partial upper airway obstruction was associated with a threefold prevalence of asthma and/or COPD in both genders, and with a 60% reduced prevalence of hypertension in females matched for age and BMI. Our results emphasize that partial upper airway obstruction is not a milder form of SDB but a different entity, the severity of which is underestimated when using the conventional apnea-hypopnea index. It seems clinically relevant to diagnose and treat the co-morbidities and SDB also in patients with partial upper airway obstruction, especially in elderly and symptomatic women.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study analyzed the feasibility and efficacy of surgical therapies in patients with sleep-disordered breathing ranging from partial upper airway obstruction during sleep to severe obstructive sleep apnea syndrome. The surgical procedures evaluated were tracheostomy, laser-assisted uvulopalatoplasty (LUPP) and uvulopalatopharyngoplasty (UPPP) with laser or ultrasound scalpel. Obstructive sleep apnea and partial upper airway obstruction during sleep were measured with the static charge-sensitive bed (SCSB) and pulse oximeter. The patients with severe obstructive sleep apnea syndrome were treated with tracheostomy. Palatal surgery was performed only if the upper airway narrowing occurred exclusively at the soft palate level in patients with partial upper airway obstruction during sleep. The ultrasound scalpel technique was compared to laser-assisted UPPP. The efficacy of LUPP to reduce partial upper airway obstruction during sleep was assessed and histology of uvulopalatal specimen was compared to body fat distributional parameters and sleep study findings. Tracheostomy was effective therapy in severe obstructive sleep apnea. Partial upper airway obstruction and arterial oxyhemoglobin desaturation index during sleep decreased significantly after LUPP. The minimal retropalatal airway dimension increased and soft palate collapsibility decreased at the level where the velopharyngeal obstruction had occurred before the surgery. Ultrasound scalpel did not offer any significant benefits over the laser-assisted technique, except fewer postoperative haemorrhage events. The loose connective tissue as a manifestation of edema was the only histological finding showing correlation with partial upper airway obstruction parameters of SCSB. Tracheostomy remains a life-saving therapy and also long-term option when adherence to CPAP fails in patients with obstructive sleep apnea syndrome. LUPP effectively reduces partial upper airway obstruction during sleep provided that obstruction at the other levels than the soft palate and uvula were preoperatively excluded. Technically the ultrasound scalpel or laser surgeries are equal. In patients with partial upper airway obstruction the loose connective tissue is more important than fat accumulation in the soft palate. This supports the hypothesis that edema is a primary trigger for aggravation of upper airway narrowing during sleep at the soft palate level and evolution towards partial or complete upper airway obstruction during sleep.