998 resultados para Orbital volume


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To determine the extent to which the accuracy of magnetic resonance imaging (MRI) based virtual 3-dimensional (3D) models of the intact orbit can approach that of the gold standard, computed tomography (CT) based models. The goal was to determine whether MRI is a viable alternative to CT scans in patients with isolated orbital fractures and penetrating eye injuries, pediatric patients, and patients requiring multiple scans in whom radiation exposure is ideally limited. Materials and Methods: Patients who presented with unilateral orbital fractures to the Royal Brisbane and Women’s Hospital from March 2011 to March 2012 were recruited to participate in this cross-sectional study. The primary predictor variable was the imaging technique (MRI vs CT). The outcome measurements were orbital volume (primary outcome) and geometric intraorbital surface deviations (secondary outcome)between the MRI- and CT-based 3D models. Results: Eleven subjects (9 male) were enrolled. The patients’ mean age was 30 years. On average, the MRI models underestimated the orbital volume of the CT models by 0.50 0.19 cm3 . The average intraorbital surface deviation between the MRI and CT models was 0.34 0.32 mm, with 78 2.7% of the surface within a tolerance of 0.5 mm. Conclusions: The volumetric differences of the MRI models are comparable to reported results from CT models. The intraorbital MRI surface deviations are smaller than the accepted tolerance for orbital surgical reconstructions. Therefore, the authors believe that MRI is an accurate radiation-free alternative to CT for the primary imaging and 3D reconstruction of the bony orbit. �

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción: El conocimiento actual de la fisiopatología del envejecimiento periorbitario justifica la aplicación de materiales de relleno inyectables, dado que se enfocan en la restauración del volumen perdido en esta zona, convirtiéndose en una excelente alternativa a procedimientos quirúrgicos que remueven el tejido excedente. Sin embargo los efectos y la seguridad de esta naciente tendencia terapéutica aún no se sustentan en una sólida base científica. El objetivo de esta revisión es identificar el material de relleno inyectable más adecuado para el manejo de los defectos volumétricos estéticos de la región periorbitaria. Metodología: Se realizó una búsqueda exhaustiva de los artículos indexados publicados del 1º de enero de 2.000 al 30 de septiembre de 2.013, en diversas bases de datos electrónicas, se seleccionaron catorce publicaciones, se extrajo la información referente a datos demográficos, la intervención, el seguimiento y los desenlaces y se realizó un análisis de 14 estudios que cumplieron los criterios. Resultados: Todos los artículos incluidos poseían un bajo nivel de evidencia y del grado de recomendación. Todos los materiales de relleno se asociaron a altos niveles de satisfacción para el paciente, adecuada mejoría de la apariencia estética y similares efectos colaterales, el ácido hialurónico fue el material de relleno inyectable más utilizado en la región periorbitaria. Discusión: Los materiales de relleno inyectable mejoran los defectos volumétricos estéticos de la región periorbitaria pero es necesaria mayor evidencia para determinar el tipo relleno más apropiado para esta condición.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Avaliar os adipócitos da gordura orbitária de coelhos após enucleação e evisceração. MÉTODOS: Foram estudados vinte e três espécimes de gordura orbitária, provenientes de 23 coelhos com idade de 42 dias, sendo 11 submetidos à cirurgia de enucleação e 12 à evisceração. Os animais foram sacrificados 30, 90 e 180 dias após a cirurgia, avaliando-se a gordura orbitária ao microscópio óptico (aumento de 200x) e usando o programa IpWin 32. A área média celular foi calculada a partir do número de adipócitos por campo e da área de cada adipócito, tendo sido comparados os resultados dos grupos (enucleação e evisceração) usando teste estatístico não paramétrico para avaliação da área dos adipócitos. RESULTADOS: Não houve diferença significativa entre a área média dos adipócitos quando considerado o procedimento cirúrgico (enucleação e evisceração), ou quando considerado o momento de sacrifício. CONCLUSÃO: Tendo em vista que a área dos adipócitos foi semelhante e não variou significativamente após a enucleação ou a evisceração, em período de observação de até 180 dias, a diminuição de volume orbitário que ocorre nas cavidades anoftálmicas deve ser conseqüência de outros mecanismos, como mudanças na distribuição espacial da gordura da órbita.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Avaliar e comparar a biocompatibilidade de esferas de silicone gelatinosas e rígidas em cavidades evisceradas de coelhos. MÉTODOS: Trinta coelhos tiveram o olho direito eviscerado com implantação de esferas de silicone gelatinosas (Grupo I) ou rígidas (Grupo II). Foi realizada avaliação clínica diária, ultrassonografia da cavidade orbitária, análise histológica e morfométrica da pseudocápsula que se formou ao redor dos implantes aos 7, 30 e 90 dias após a cirurgia, com avaliação estatística dos resultados. RESULTADOS: Houve boa integração das esferas com os tecidos orbitários e semelhança de resposta tecidual com ambas as esferas. Duas esferas de silicone gelatinosas e uma rígida extruíram. A pseudocápsula que se formou ao redor das esferas gelatinosas foi mais organizada, com espessura e reação inflamatória menores que a observada nas esferas rígidas. CONCLUSÕES: Esferas de silicone gelatinosas e rígidas tiveram boa integração tecidual em cavidades evisceradas de coelhos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o volume orbitário de coelhos recém-nascidos, enucleados ou eviscerados, sem ou com reposição do volume orbitário por esferas de polietileno poroso de 10 mm, usando a tomografia computadorizada, o teste de deslocamento de água e a medida da abertura orbitária por Image-J. MÉTODOS: Estudo experimental, usando 48 coelhos albinos, com idade de 42 dias, submetidos à evisceração ou enucleação, com implante de esfera de polietileno poroso de 10 mm de diâmetro ou sem implante. O lado esquerdo não foi submetido à cirurgia e foi usado como controle. Após 1, 3 e 6 meses, foram sacrificados quatro animais de cada grupo. Os crânios foram preparados para estudo do osso seco por maceração da peça, e analisados em relação ao volume orbitário por tomografia computadorizada, teste de deslocamento de água e avaliação da abertura orbitária usando o software Image-J. RESULTADOS: O volume das órbitas enucleadas ou evisceradas, com ou sem o uso do implante não apresentaram diferenças estatisticamente significativas (p<0,05) entre si, quando avaliadas por tomografia computadorizada, pelo teste de deslocamento de água e pelo Image-J. CONCLUSÃO: O desenvolvimento orbitário de coelhos com idade superior a 42 dias de vida não se altera quando se opta pela enucleação ou pela evisceração, ou quando se utiliza ou não implantes orbitários. O teste de deslocamento de água apresentou resultados semelhantes aos fornecidos pela tomografia, sugerindo-se sua utilização em experimentação científica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Non-absorbable microgranular hydroxyapatite was infiltrated into the subepidermal abdominal region of guinea pigs in order to assess the possibility of using this material to correct deficiencies in orbital volume. Microgranular hydroxyapatite (2.0 ml) was subepidermally infiltrated into the abdominal region of 20 guinea pigs. The animals were divided into four experimental groups of 5 animals each, which were killed 7 (G1), 15 (G2), 30 (G3) and 60 (G4) days after infiltration. The area and the largest and smallest diameters of the nodules formed by infiltration were evaluated at the site of infiltration and histological examination was performed. The mean granuloma area was similar in all groups. Histopathological examination showed that the material remained isolated from surrounding tissues by a pseudocapsule that became denser throughout the experiment. A host reaction started with young fibroblastic tissue that evolved to dense tissue until cartilaginous tissue was formed in G4, progressively advancing towards the center of the granuloma from G1 to G4. Non-absorbable microgranular hydroxyapatite is an inert material that was well tolerated by the animals studied, with maintenance of the infiltrated volume, and may perhaps be useful to fill anophthalmic cavities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: Gelatinous polyethylene (GP) has been used as an orbital implant to evaluate volume maintenance and tissue reaction in the anophthalmic socket in a rabbit model. METHODS: Twenty-eight Norfolk white rabbits underwent unilateral evisceration with placement of 2ml GP (GP group - 16 animals) or 2ml 0.9% sodium chloride solution (Control group - 12 animals). Animal behavior, postoperative tissue response and socket conditions were evaluated. The animals were sacrificed at 7, 15, 30 and 60 days after the surgery and the bulbs were enucleated; volume maintenance and histopathological evaluation were done in the enucleated bulbs. The results were submitted to statistical analysis. RESULTS: All animals showed normal behavior. The orbital volume maintenance was better in the GP group. Histopathology in the GP animals showed mild tissue inflammation throughout the evaluation period and a thin pseudocapsule formation surrounding the orbital implant material. CONCLUSION: The clinical findings, good orbital volume maintenance and mild inflammatory tissue response make GP a good choice to replace the lack of volume in anophthalmic socket reconstruction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The implants are usually used after removal of the eye or its internal content, in order to maintain the orbital volume or, as in medicine, provide also the subsequent placement of ocular prosthesis. Considering prosthetic surgery procedures of high relevance in human and veterinary ophthalmology, this paper seek to review the main types of implants described in national and international literature, as well as describe the main complications when they are used in humans and veterinary patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Para a recuperação da estética facial,há necessidade de reposição do volume orbitário perdido em decorrência de eviscerações ou enucleações. Este estudo foi realizado com os objetivos de avaliar comparativamente a biocompatibilidade e a manutenção do volume orbitário com o uso de esferas de hidroxiapatita sintética e de polietileno poroso, na reconstrução de cavidades evisceradas de coelhos. Métodos: Para isso foram utilizados 56 coelhos albinos, submetidos à evisceração do olho direito, com colocação de esferas de hidroxiapatita sintética (G1 – 28 animais) ou polietileno poroso (G2 – 28 animais).Quatro coelhos de cada grupo foram sacrificados em 7 momentos experimentais: 7, 15, 30, 60, 90, 120 e 180 dias após a evisceração. Após o sacrifício, o conteúdo da cavidade orbitária direita foi removido e seccionado na porção central em duas hemi-metades,uma das quais foi preparada para exame histopatológico; exame ultra-estrutural em microscópio eletrônico de varredura foi feito em dois animais de 7, 60 e 180 dias, de ambos os grupos experimentais. Resumo 118 Resultados: Observou-se aos 7 dias, tecido conjuntivo frouxo, constituído de células inflamatórias e hemáceas, em meio à rede de fibrina, principalmente na periferia da esfera de hidroxiapatita e chegando até ao centro da esfera de polietileno; a reação tecidual tornou-se mais densa com o passar do tempo. Decorridos 60 dias, observou-se em G1, início de metaplasia óssea que se acentuou ao longo do experimento. Em todos os momentos experimentais, a inflamação,predominantemente macrofágica, foi muito mais acentuada em G1.O volume da cavidade esclero-corneana foi melhor mantido em G2. Conclusão: a esfera de hidroxiapatita sintética provoca mais inflamação que a de polietileno poroso e é menos eficiente na manutenção do volume orbitário... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The spatial error structure of daily precipitation derived from the latest version 7 (v7) tropical rainfall measuring mission (TRMM) level 2 data products are studied through comparison with the Asian precipitation highly resolved observational data integration toward evaluation of the water resources (APHRODITE) data over a subtropical region of the Indian subcontinent for the seasonal rainfall over 6 years from June 2002 to September 2007. The data products examined include v7 data from the TRMM radiometer Microwave Imager (TMI) and radar precipitation radar (PR), namely, 2A12, 2A25, and 2B31 (combined data from PR and TMI). The spatial distribution of uncertainty from these data products were quantified based on performance metrics derived from the contingency table. For the seasonal daily precipitation over a subtropical basin in India, the data product of 2A12 showed greater skill in detecting and quantifying the volume of rainfall when compared with the 2A25 and 2B31 data products. Error characterization using various error models revealed that random errors from multiplicative error models were homoscedastic and that they better represented rainfall estimates from 2A12 algorithm. Error decomposition techniques performed to disentangle systematic and random errors verify that the multiplicative error model representing rainfall from 2A12 algorithm successfully estimated a greater percentage of systematic error than 2A25 or 2B31 algorithms. Results verify that although the radiometer derived 2A12 rainfall data is known to suffer from many sources of uncertainties, spatial analysis over the case study region of India testifies that the 2A12 rainfall estimates are in a very good agreement with the reference estimates for the data period considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In North America, terrestrial records of biodiversity and climate change that span Marine Oxygen Isotope Stage (MIS) 5 are rare. Where found, they provide insight into how the coupling of the ocean-atmosphere system is manifested in biotic and environmental records and how the biosphere responds to climate change. In 2010-2011, construction at Ziegler Reservoir near Snowmass Village, Colorado (USA) revealed a nearly continuous, lacustrine/wetland sedimentary sequence that preserved evidence of past plant communities between similar to 140 and 55 lea, including all of MIS 5. At an elevation of 2705 m, the Ziegler Reservoir fossil site also contained thousands of well-preserved bones of late Pleistocene megafauna, including mastodons, mammoths, ground sloths, horses, camels, deer, bison, black bear, coyotes, and bighorn sheep. In addition, the site contained more than 26,000 bones from at least 30 species of small animals including salamanders, otters, muskrats, minks, rabbits, beavers, frogs, lizards, snakes, fish, and birds. The combination of macro- and micro-vertebrates, invertebrates, terrestrial and aquatic plant macrofossils, a detailed pollen record, and a robust, directly dated stratigraphic framework shows that high-elevation ecosystems in the Rocky Mountains of Colorado are climatically sensitive and varied dramatically throughout MIS 5 

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements of X-ray diffraction, electrical resistivity, and magnetization are reported across the Jahn-Teller phase transition in LaMnO(3). Using a thermodynamic equation, we obtained the pressure derivative of the critical temperature (T(JT)), dT(JT)/dP = -28.3 K GPa(-1). This approach also reveals that 5.7(3)J(mol K)(-1) comes from the volume change and 0.8(2)J(mol K)(-1) from the magnetic exchange interaction change across the phase transition. Around T(JT), a robust increase in the electrical conductivity takes place and the electronic entropy change, which is assumed to be negligible for the majority of electronic systems, was found to be 1.8(3)J(mol K)(-1).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A two and a half-year-old female Persian cat was presented with a history of bilateral chronic ocular discharge. Epiphora bilateral mucous ocular discharge and a volume increase in bulbar conjunctiva on the dorsolateral quadrant of the right eye were noticed during routine ophthalmic examination. Ophthalmic examination and the aspiration cytology showed the presence of adipose tissue at the right eye dorsolateral quadrant indicating orbital fat prolapse.