983 resultados para Non-Proportional Loading


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental stress-strain data of OFHC copper first under torsion to 13% and then under torsion-tension to about 10% are used to study the characteristics of three elastic-plastic constitutive models: Chaboche's super-positional nonlinear model, Dafalias and Popov's two surface model and Watanabe and Atluri's version of the endochronic model. The three models, originally oriented for infinitesimal deformation, have been extended for finite deformation. The results show (a) the Mises-type yield surface used in the three models brings about significant departure of the predictions from the experimental data; (b) Chaboche's and Dafalias' models are easier than Watanabe and Atluri's model in determining the material parameters in them, and (c) Chaboche's and Watanabe & Atluri's models produce almost the same prediction to the data, while Dafalias' model cannot accurately predict the plastic deformations when a loading path changes in its direction. Copyright (C) 1996 Elsevier Science Ltd

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fatigue lives are reduced accompanying an additional cyclic hardening under strain controlled non-proportional cyclic loading in which principal directions of stress and strain are altered within a cycle. This study predicts non-proportional cyclic hardening and multiaxial fatigue life for several BCC and FCC metals under constant amplitude strain cycling. A novel procedure to determine non-proportional cyclic hardening form uniaxial tensile properties has discussed in this study. Standard plastic strain energy density based fatigue criteria with considering the non-proportional cyclic hardening effect successfully predicts multiaxial fatigue lives. The predictions of non-proportional cyclic hardening and multiaxial fatigue life through models are validated by experimental results of various BCC and FCC metals which are collected from literatures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims and objectives  For prediction of risk of cardiovascular end points using survival models the proportional hazards assumption is often not met. Thus, non-proportional hazards models are more appropriate for developing risk prediction equations in such situations. However, computer program for evaluating the prediction performance of such models has been rarely addressed. We therefore developed SAS macro programs for evaluating the discriminative ability of a non-proportional hazards Weibull model developed by Anderson (1991) and that of a proportional hazards Weibull model using the area under receiver operating characteristic (ROC) curve.

Method  Two SAS macro programs for non-proportional hazards Weibull model using Proc NLIN and Proc NLP respectively and model validation using area under ROC curve (with its confidence limits) were written with SAS IML language. A similar SAS macro for proportional hazards Weibull model was also written.

Results  The computer program was applied to data on coronary heart disease incidence for a Framingham population cohort. The five risk factors considered were current smoking, age, blood pressure, cholesterol and obesity. The predictive ability of the non-proportional hazard Weibull model was slightly higher than that of its proportional hazard counterpart. An advantage of SAS Proc NLP in terms of the example provided here is that it provides significance level for the parameter estimates whereas Proc NLIN does not.

Conclusion  The program is very useful for evaluating the predictive performance of non-proportional and proportional hazards Weibull models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this paper is to present the application of a three-phase harmonic propagation analysis time-domain tool, using the Norton model to approach the modeling of non-linear loads, making the harmonics currents flow more appropriate to the operation analysis and to the influence of mitigation elements analysis. This software makes it possible to obtain results closer to the real distribution network, considering voltages unbalances, currents imbalances and the application of mitigation elements for harmonic distortions. In this scenario, a real case study with network data and equipments connected to the network will be presented, as well as the modeling of non-linear loads based on real data obtained from some PCCs (Points of Common Coupling) of interests for a distribution company.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Immediate and early loading of dental implants can simplify treatment and increase overall patient satisfaction. The purpose of this 3-year prospective randomized-controlled multicenter study was to assess the differences in survival rates and bone level changes between immediately and early-loaded implants with a new chemically modified surface (SLActive). This investigation shows interim results obtained after 5 months. MATERIAL AND METHODS: Patients > or =18 years of age missing at least one tooth in the posterior maxilla or mandible were enrolled in the study. Following implant placement, patients received a temporary restoration either on the day of surgery (immediate loading) or 28-34 days after surgery (early loading); restorations consisted of single crowns or two to four unit fixed dental prostheses. Permanent restorations were placed 20-23 weeks following surgery. The primary efficacy variable was change in bone level (assessed by standardized radiographs) from baseline to 5 months; secondary variables included implant survival and success rates. RESULTS: A total of 266 patients were enrolled (118 males and 148 females), and a total of 383 implants were placed (197 and 186 in the immediate and early loading groups, respectively). Mean patient age was 46.3+/-12.8 years. After 5 months, implant survival rates were 98% in the immediate group and 97% in the early group. Mean bone level change from baseline was 0.81+/-0.89 mm in the immediate group and 0.56+/-0.73 mm in the early group (P<0.05). Statistical analysis revealed a significant center effect (P<0.0001) and a significant treatment x center interaction (P=0.008). CONCLUSIONS: The results suggested that Straumann implants with an SLActive can be used predictably in time-critical (early or immediate) loading treatment protocols when appropriate patient selection criteria are observed. The mean bone level changes observed from baseline to 5 months (0.56 and 0.81 mm) corresponded to physiological observations from other studies, i.e., were not clinically significant. The presence of a significant center effect and treatment x center interaction indicated that the differences in bone level changes between the two groups were center dependent.