Microstrain Around Dental Implants Supporting Fixed Partial Prostheses Under Axial and Non-Axial Loading Conditions, In Vitro Strain Gauge Analysis


Autoria(s): Oliveira de Vasconcellos, Luis Gustavo; Nishioka, Renato Sussumu; Reis de Vasconcellos, Luana Marotta; Balducci, Ivan; Kojima, Alberto Noriyuki
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

03/12/2014

03/12/2014

01/11/2013

Resumo

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Formato

E546-E551

Identificador

http://dx.doi.org/10.1097/SCS.0b013e31829ac83d

Journal Of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 24, n. 6, p. E546-E551, 2013.

1049-2275

http://hdl.handle.net/11449/112971

10.1097/SCS.0b013e31829ac83d

WOS:000330354500005

Idioma(s)

eng

Publicador

Lippincott Williams & Wilkins

Relação

Journal of Craniofacial Surgery

Direitos

closedAccess

Palavras-Chave #Strain gauge analysis #dental implants #dental prosthesis #implant-supported dental prosthesis
Tipo

info:eu-repo/semantics/article