785 resultados para Newborn Examination


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Chapter explains the processes by which babies become jaundiced and the physiology of tis condition; explains also the different types of neonatal jaundice

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This poster illustrated the role of the midiwfe in the final examination and discharge of the newborn baby.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE:: Report of a 16q24.1 deletion in a premature newborn, demonstrating the usefulness of array-based comparative genomic hybridization in persistent pulmonary hypertension of the newborn and multiple congenital malformations. DESIGN:: Descriptive case report. SETTING:: Genetic department and neonatal intensive care unit of a tertiary care children's hospital. INTERVENTIONS:: None. PATIENT:: We report the case of a preterm male infant, born at 26 wks of gestation. A cardiac malformation and bilateral hydronephrosis were diagnosed at 19 wks of gestation. Karyotype analysis was normal, and a 22q11.2 microdeletion was excluded by fluorescence in situ hybridization analysis. A cesarean section was performed due to fetal distress. The patient developed persistent pulmonary hypertension unresponsive to mechanical ventilation and nitric oxide treatment and expired at 16 hrs of life. MEASUREMENTS AND MAIN RESULTS:: An autopsy revealed partial atrioventricular canal malformation and showed bilateral dilation of the renal pelvocaliceal system with bilateral ureteral stenosis and annular pancreas. Array-based comparative genomic hybridization analysis (Agilent oligoNT 44K, Agilent Technologies, Santa Clara, CA) showed an interstitial microdeletion encompassing the forkhead box gene cluster in 16q24.1. Review of the pulmonary microscopic examination showed the characteristic features of alveolar capillary dysplasia with misalignment of pulmonary veins. Some features were less prominent due to the gestational age. CONCLUSIONS:: Our review of the literature shows that alveolar capillary dysplasia with misalignment of pulmonary veins is rare but probably underreported. Prematurity is not a usual presentation, and histologic features are difficult to interpret. In our case, array-based comparative genomic hybridization revealed a 16q24.1 deletion, leading to the final diagnosis of alveolar capillary dysplasia with misalignment of pulmonary veins. It emphasizes the usefulness of array-based comparative genomic hybridization analysis as a diagnostic tool with implications for both prognosis and management decisions in newborns with refractory persistent pulmonary hypertension and multiple congenital malformations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

P>A case of a type I rectal atresia (also known as membranous rectal atresia) in a newborn donkey is reported. Clinical examination, survey radiographs and barium enema radiographs suggested rectal atresia. An exploratory laparotomy was performed; however, surgical correction of the defect was not possible due to the narrow pelvic cavity. Euthanasia was performed. At necropsy, it was possible to observe a fibrous cord connecting the small colon to a residual rectal ampulla, which opened to a normal anus. The radiographic and anatomical characteristics enabled the classification of the defect as type I rectal atresia, which is a rare congenital anomaly that is difficult to correct through surgery. This report contributes to the study of rectal atresia in newborn equids, alerts for the occurrence in donkeys and is, to our knowledge, the first to be reported in this species in Brazil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present investigation was to determine the course of maternal blood glucose levels in pregnant rats and its repercussions on the glucose levels and pancreas of their newborn pups. Diabetes was induced by alloxan (42 mg/kg body weight) and streptozotocin (40 mg/kg). Sixty-two pregnant Wistar rats weighing 180 to 250 g were divided into a control group and two groups with moderate (120 to 200 mg/dl glucose) and severe diabetes (greater than 200 mg/dl glucose), respectively. Blood glucose levels were measured in the dams on the 1st, 14th, and 21st days of pregnancy and in the pups at birth. The results were pooled for each litter. The fetal pancreases were removed after cesarian section performed on the 21st day of pregnancy, pooled for each litter and processed for histopathologic examination by light microscopy. Maternal blood glucose levels were significantly increased compared with the first day of pregnancy in both normal and diabetic rats starting on the 14th day of pregnancy. Fetal blood glucose levels correlated with maternal levels. The histopathologic changes characterized by vacuolization and basophilia of the cytoplasm of endocrine pancreas of newborn pups from darns with moderate or severe diabetes suggested pancreatic hyperactivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a 3 day old girl born at term presenting with an interlabial, cystic mass. Pregnancy, delivery and routine antenatal screening were unremarkable. The smooth lesion was located in the anterior half of the vulva, covered with thin vessels. The medially displaced urethra and the medio-posteriorly displaced hymen were identified. Voiding was not impaired. We discuss the differential diagnosis of vulvar masses in the newborn girl. A thorough clinical examination must be the standard of care of pediatric examinations in infants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.