1000 resultados para Nephelometry and Turbidimetry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the performance of the turbidimetric method of C-reactive protein (CRP) as a measure of low-grade inflammation in patients admitted with non-ST elevation acute coronary syndromes (ACS). METHODS: Serum samples obtained at hospital arrival from 68 patients (66±11 years, 40 men), admitted with unstable angina or non-ST elevation acute myocardial infarction were used to measure CRP by the methods of nephelometry and turbidimetry. RESULTS: The medians of C-reactive protein by the turbidimetric and nephelometric methods were 0.5 mg/dL and 0.47 mg/dL, respectively. A strong linear association existed between the 2 methods, according to the regression coefficient (b=0.75; 95% C.I.=0.70-0.80) and correlation coefficient (r=0.96; P<0.001). The mean difference between the nephelometric and turbidimetric CRP was 0.02 ± 0.91 mg/dL, and 100% agreement between the methods in the detection of high CRP was observed. CONCLUSION: In patients with non-ST elevation ACS, CRP values obtained by turbidimetry show a strong linear association with the method of nephelometry and perfect agreement in the detection of high CRP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interferences with the Olympus immunoturbidimetric assay for ferritin have been reported because the antibodies used in the immunoassay are derived from rabbits. Rabbits are familiar pets known to be a risk factor for developing heterophilic (or interfering) antibodies. This report shows how the current Olympus Ferritin assay has been improved to eliminate the interference from heterophilic antibodies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aiming to know the influence of the pluviometric precipitation over the physical chemical and bacteriological characteristics of the water coming from three sources of public supply, and to verify the probable origin of faecal contamination, tests of total coliforms, faecal coliforms, faecal streptococci and mesophilic microorganisms, as well as the determination of pH, temperature and turbidity of 156 water samples were done. The samples were taken from a stream, a drain and an artesian well, located in the city of Jaboticabal, SP, Brazil. The results obtained showed that the occurrence of pluviometric precipitation determined a significant increase of the number of total coliforms in the water samples from the stream. The use of the ratio CF/EF, indicate the probable origin of the faecal contamination only in the samples of the water coming from the stream, which were defined as being of human origin. In relation to the physical-chemical composition it was noticed that the influence of the pluviometric precipitation over the turbidity appeared to be higher and significant in the samples of water of the stream.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Rabies is considered a fatal disease once clinical symptoms have developed. The aim of this study was to evaluate epidemiological aspects and immune response in patients attacked by domestic and wild animals and subjected to post-exposure rabies treatment with equine serum and associated vaccine. Thirty-three patients were evaluated; they were between 13 and 65 years old, 75.8% were male and 24.2% female, and from the Botucatu neighborhood. Twenty healthy control individuals with the same age range were also studied. Specific antibodies to equine immunoglobulins and IFN-γ, IL-2, IL-4, and IL-10 production were evaluated by ELISA. IgM, IgE, IgG and subclasses, and rabies virus antibodies serum levels were determined by nephelometry and seroneutralization methods, respectively. No anaphylactic or serum sickness allergic reactions were observed in patients after treatment. Anti-equine IgG levels were significantly higher than those of IgM after 14 and 28 days of treatment. Protective antibodies to rabies virus > 0.5 UI/ml were detected in 84.6% and 75% of patients at days 14 and 28, respectively. IFN-γ, IL-2 and IL-10 levels in patients before and 48h after treatment were significantly higher than in controls suggesting that both Th1 and Th2 cells were activated in the patients. Serum IgM levels were higher at day 14, and IgG 2 and IgE levels were higher at day 28 of treatment. These results suggest that post-exposure rabies treatment in humans induces significant alterations in patient immune response characterized by increased levels of cytokines, serum levels of specific rabies virus antibodies, and the equine serum components employed in the treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background & aims: This study evaluated the relationship between vitamin A concentration in maternal milk and the characteristics of the donors of a Brazilian human milk bank. Material and methods: A total of 136 donors were selected in 2003-2004 for micronutrient determinations in breast milk and blood, anthropometric measurements and investigation of obstetric, socioeconomic-demographic factors, and life style. Maternal serum/milk samples were obtained for vitamin A, iron, copper, and zinc determinations. Vitamin A concentrations in breast milk and blood were assessed by high-performance liquid chromatography. Copper, zinc and iron concentrations in breast milk, and copper and zinc concentrations in blood were detected by atomic emission spectrophotometry. Serum ceruloplasmin and serum iron were determined, respectively, by nephelometry and colorimetry. A linear regression model assessed the associations between milk concentrations of vitamin A and maternal factors. Results: Vitamin A in milk presented positive associations with iron in milk (p < 0.001), serum retinol (p = 0.03), maternal work (p = 0.02), maternal age (p = 0.02). and oral contraceptive use (p = 0.01), and a negative association with % body fat (p = 0.01) (R(2) = 0.47). Conclusion: These results suggest that some nutritional, obstetric, and socioeconomic-demographic factors may have an effect on mature breast milk concentrations of vitamin A in apparently healthy Brazilian mothers. (C) 2009 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As técnicas de fluorimetria, condutometria, viscosimetria, turbidimetria, espalhamento de luz e espalhamento de raios-X a baixo ângulo (SAXS) foram empregadas no estudo da agregação de diferentes surfactantes aniônicos em presença de soluções aquosas diluídas de (hidroxipropil)celulose (HPC) 0,25% m/m, (hidroxipropilmetil)celulose (HPMC) 0,20% m/m e HPMC 0,10% m/m / NaCl 0,10 mol L-1. Também foram investigadas através de SAXS soluções concentradas de HPC (30, 40 e 50% m/m). Admitindo-se uma faixa geral de concentração, entre 10-4 e 10-1 mol L-1, foram utilizados neste estudo os surfactantes colato de sódio (CS), deoxicolato de sódio (DC), derivados dos sais biliares, e o alquilsintético dodecilsulafato de sódio (SDS). Observou-se que os polímeros contribuem diferentemente no processo de agregação de cada surfactante, evidenciado pela mudança dos valores da concentração de agregação crítica (CAC) em relação à concentração micelar crítica (CMC). Os resultados condutométricos confirmaram a interação éteres de celulose/sais biliares, embora a mesma tenha se mostrado mais fraca em relação a éteres de celulose/SDS. Os dados termodinâmicos demonstraram que a formação de agregados polímero/surfactante apresenta maior estabilidade do que as próprias micelas livres. Os resultados de viscosimetria e turbidimetria evidenciaram as diferenças estruturais entre HPC e HPMC, assim como entre os surfactantes. Através do espalhamento de luz dinâmico, verificou-se a existência de dois modos de correlação, rápido e lento. O primeiro é atribuído à cadeia polimérica isolada, agregados polímero/surfactante intramoleculares ou mesmo a micelas livres. Por sua vez, o modo lento relaciona-se a clusters poliméricos ou agregados polímero/surfactante intermoleculares. Adicionalmente, as curvas de distribuição dos tempos de relaxação demonstraram a influência de cada surfactante sobre a dinâmica dos polímeros. Tal influência é percebida antes mesmo da CAC, contrariando o modelo da interação polímero/surfactante proposto por Cabane. Os resultados de SAXS acusaram a formação de domínios líquido-cristalinos em xx soluções concentradas de HPC, assim como confirmaram a presença de micelas livres a altas concentrações de surfactantes nos sistemas diluídos. Em linhas gerais, os resultados indicaram a interação dos polímeros com SDS mais efetiva do que os mesmos polímeros e os sais biliares. No que tange à natureza do polímero, a HPC mostrou uma maior estabilidade na sua interação com os surfactantes do que a HPMC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Specificities for carbohydrate IgG antibodies, thought to be predominantly of the IgG2 subclass, have never been broadly examined in healthy human subjects. OBJECTIVE: To examine commercial intravenous immunoglobulin (IVIG) preparations for their ability to recognize a wide range of glycans and to determine the contribution of IgG2 to the binding pattern observed. METHODS: We used a glycan microarray to evaluate IVIG preparations and a control mix of similar proportions of human myeloma IgG1 and IgG2 for binding to 377 glycans, courtesy of the Consortium for Functional Glycomics Core H. Glycans recognized were categorized using public databases for their likely cellular sources. IgG2 was depleted from IVIG by using immunoaffinity chromatography, and depletion was confirmed by using nephelometry and surface plasmon resonance. RESULTS: Nearly half of the glycans bound IgG. Some of the glycans with the greatest antibody binding can be found in structures of human pathogenic bacteria (eg, Streptococcus pneumoniae, Mycobacterium tuberculosis, Vibrio cholera) and nonpathogenic bacteria, including LPS and lipoteichoic acid, capsular polysaccharides, and exopolysaccharides. Surprisingly, depletion of IgG2 had only a modest effect on anticarbohydrate recognition patterns compared with the starting IVIG preparation. Little to no binding activity was detected to human endogenous glycans, including tumor-associated antigens. CONCLUSIONS: This novel, comprehensive analysis provides evidence that IVIG contains a much wider range than previously appreciated of anticarbohydrate IgG antibodies, including those recognizing both pathogenic and non-pathogen-associated prokaryotic glycans.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An aging population and increasing rates of diabetes mellitus contribute to a high prevalence of kidney dysfunction – approximately 10 percent of adults in developed countries have chronic kidney disease (CKD). CKD is a progressive loss of kidney function and this remains permanent. Early recognition of this condition is important for prevention or impeding severe adverse cardiac and renal outcomes. Cystatin C is a low molecular weight cysteine protease inhibitor that has emerged as a biomarker of kidney function. The special potential of plasma cystatin C in this setting is related to its independency of muscle mass, which is a remarkable limitation of the traditional marker creatinine. Cystatin C is a sensitive marker in diagnosing mild and moderate CKD, especially in small children, in the elderly and in conditions where muscle mass is affected. Cystatin C is quantified with immunoassays, mainly based on particle-enhanced nephelometry (PENIA) or turbidimetry (PETIA). The aim of this study was to develop a rapid and reliable assay for quantification of human cystatin C in plasma or serum by utilizing time-resolved fluorescence-based immunoassay methods. This was accomplished by utilizing different antibodies, including polyclonal and 7 monoclonal antibodies against cystatin C. Different assay designs were tested and the best assay was further modified to a dry-reagent double monoclonal assay run on an automated immunonalyzer. This assay was evaluated for clinical performance in estimating reduced kidney function and in predicting risk of adverse outcomes in patients with non-ST elevation acute coronary syndrome. Of the tested assay designs, heterogeneous non-competitive assay had the best performace and was chosen to be developed further. As an automated double monoclonal assay, this assay enabled a reliable measurement of clinically relevant cystatin C concentrations. It also showed a stronger concordance with the reference clearance method than the conventional PETIA method in patients with reduced kidney function. Risk of all-cause mortality and combined events, defined by death and myocardial infarction, increased with higher cystatin C and cystatin C remained an independent predictor of death and combined events after adjustment to nonbiochemical baseline factors. In conclusion, the developed dry-reagent double monoclonal assay allows rapid and reliable quantitative measurement of cystatin C. As measured with the developed assay, cystatin C is a potential predictor of adverse outcomes in cardiac patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An improved flow-based procedure is proposed for turbidimetric sulphate determination in waters. The flow system was designed with solenoid micro-pumps in order to improve mixing conditions and minimize reagent consumption as well as waste generation. Stable baselines were observed in view of the pulsed flow characteristic of the systems designed with solenoid micro-pumps, thus making the use of washing solutions unnecessary. The nucleation process was improved by stopping the flow prior to the measurement, thus avoiding the need of sulphate addition. When a 1-cm optical path flow cell was employed, linear response was achieved within 20-200 mg L(-1), described by the equation S = -0.0767 + 0.00438C (mg L(-1)), r = 0.999. The detection limit was estimated as 3 mg L(-1) at the 99.7% confidence level and the coefficient of variation was 2.4% (n = 20). The sampling rate was estimated as 33 determinations per hour. A long pathlength (100-cm) flow cell based on a liquid core waveguide was exploited to increase sensitivity in turbidimetry. Baseline drifts were avoided by a periodical washing step with EDTA in alkaline medium. Linear response was observed within 7-16 mg L(-1), described by the equation S = -0.865 + 0.132C (mg L(-1)), r = 0.999. The detection limit was estimated as 150 mu g L(-1) at the 99.7% confidence level and the coefficient of variation was 3.0% (n = 20). The sampling rate was estimated as 25 determinations per hour. The results obtained for freshwater and rain water samples were in agreement with those achieved by batch turbidimetry at the 95% confidence level. (C) 2008 Elsevier B.V All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A multi-pumping flow system exploiting prior assay is proposed for sequential turbidimetric determination of sulphate and chloride in natural waters. Both methods are implemented in the same manifold that provides facilities for: in-line sample clean-up with a Bio-Rex 70 mini-column with fluidized beads: addition of low amounts of sulphate or chloride ions to the reaction medium for improving supersaturation; analyte precipitation with Ba(2+) or Ag(+); real-time decision on the need for next assay. The sample is initially run for chloride determination, and the analytical signal is compared with a preset value. If higher, the sample is run again, now for sulphate determination. The strategy may lead to all increased sample throughput. The proposed system is computer-controlled and presents enhanced figures of merit. About 10 samples are run per hour (about 60 measurements) and results are reproducible and Unaffected by the presence of potential interfering ions at concentration levels usually found in natural waters. Accuracy was assessed against ion chromatography. (C) 2008 Elsevier B.V. All rights reserved.