976 resultados para Needle Biopsy
Resumo:
Two cases of Chronic Pulmonary Histoplasmosis are reported and other eleven cases, collected from Brazilian literature, are commented. After being clinically cured, one of our patients presented an Aspergillus fungus ball inside a cavitation in the wall of which H. capsulatum was disclosed. Comments are also done on the diagnosis of the mycosis
Resumo:
PURPOSE: To report the experience of a radiology department in the use of computed tomography - guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. METHODS: This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). RESULTS: In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. CONCLUSION: The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules.
Resumo:
Ultrasound-guided core-needle biopsy has high sensitivity in the diagnosis of breast cancer. The present study is aimed at detailing the main steps of such procedure, including indications, advantages, limitations, follow-up and description of the technique, besides presenting a checklist including the critical steps required for an appropriate practice of the technique. In the recent years, an increasing number of patients have required breast biopsy, indicating the necessity of a proportional increase in the number of skilled professionals to carry out the procedures and histological diagnoses. A multidisciplinary approach involving the tripod clinical practice-radiology-pathology is responsible for the highest rate of accuracy of the technique and must always be adopted.
Resumo:
Objective: To evaluate whether immunohistochemical marker studies performed on core needle biopsy (CNB) specimens accurately reflect the marker status of the tumor obtained from final surgical specimen. Methods: This was a retrospective study that used the database of the Division of Mastology of the Hospital das Clinicas, Sao Paulo, Brazil. Sixty-nine patients submitted to ultrasound-guided CNB diagnosed with breast cancer were retrospectively analyzed. Immunohistochemistry (IHC) on core biopsy specimens was compared to that of excisional biopsy regarding estrogen receptor (ER), progesterone receptor (PR), human epidermal gowth factor receptor 2 gene (HER2), p53, and Ki67. The analysis of the concordance between CNB and surgical biopsy was performed using the kappa (k) coefficient (95% CI). Results: A perfect concordance between the labeling in the surgical specimens and the preoperative biopsies in p53 (k = 1.0; 95% CI: 0.76-1.0) was identified. There was an almost perfect concordance for ER (k = 0.89; 95% CI: 0.65-1.0) and a substantial concordance for PR (k = 0.70; 95% CI: 0.46-0.93). HER2 (k = 0.61; 95% CI: 0.38-0.84) and Ki-67 (k = 0.74; 95% CI: 0.58-0.98) obtained a substantial concordance this analysis. Conclusion: The results of this study indicate that the immunohistochemical analysis of ER, PR, Ki-67, and p53 from core biopsy specimens provided results that accurately reflect the marker status of the tumor. The concordance rate of HER2 was less consistent; although it produced substantial concordance, values were very close to moderate concordance.
Resumo:
Background: Bernese mountain dogs are reported to have a shorter life expectancy than other breeds. A Major reason for this has been assigned to a high tumour prevalence, especially of histiocytic sarcoma. The efforts made by the breeding clubs to improve the longevity with the help of genetic tests and breeding value estimations are impeded by insufficiently reliable diagnoses regarding the cause of death. The current standard for post mortem examination in animals is performance of an autopsy. In human forensic medicine, imaging modalities, such as computed tomography and magnetic resonance imaging, are used with increasing frequency as a complement to autopsy. The present study investigates, whether post mortem computed tomography in combination with core needle biopsy is able to provide a definitive diagnosis of histiocytic sarcoma. For this purpose we have analysed the results of post mortem computed tomography and core needle biopsy in eleven Bernese mountain dogs. In the subsequent autopsy, every dog had a definitive diagnosis of histiocytic sarcoma, based on immunohistochemistry. Results: Computed tomography revealed space-occupying lesions in all dogs. Lesion detection by post mortem computed tomography was similar to lesion detection in autopsy for lung tissue (9 cases in computed tomography / 8 cases in autopsy), thoracic lymph nodes (9/8), spleen (6/7), kidney (2/2) and bone (3/3). Hepatic nodules, however, were difficult to detect with our scanning protocol (2/7). Histology of the core needle biopsies provided definitive diagnoses of histiocytic sarcoma in ten dogs, including confirmation by immunohistochemistry in six dogs. The biopsy samples of the remaining dog did not contain any identifiable neoplastic cells. Autolysis was the main reason for uncertain histological diagnoses. Conclusions: Post mortem computed tomography is a fast and effective method for the detection of lesions suspicious for histiocytic sarcoma in pulmonary, thoracic lymphatic, splenic, osseous and renal tissue. Optimization of the procedure regarding the scanning protocol and tissue sample size and number will improve the accuracy of the method. Keywords: Post mortem computed tomography, Core needle biopsy, Bernese mountain dog, Histiocytic sarcoma, Autopsy
Resumo:
In recent times, PSA screening and a substantial increase in prostate needle biopsies have not only resulted in detection of minute foci of cancer but have also very likely resulted in increased detection of atypical glandular proliferations. Not uncommonly, there are only a limited number of atypical glands in these biopsies, and these require careful evaluation to enable an accurate diagnosis. We describe diagnostic implications, use of immunohistochemistry, and clinical significance of these lesions. Foci of atypical glands, also labeled atypical small acinar proliferation of uncertain significance, have features suspicious for but not diagnostic of cancer. Atypical foci include a broad group of lesions of differing clinical significance. These include benign, small acinar proliferations mimicking prostate cancer and atypical glandular proliferations suspicious for carcinoma. Definite diagnosis requires accurate histopathologic assessment and judicious use of immunohistochemistry. Patients with atypical glands on prostate needle biopsy have a high risk for harboring cancer and therefore have an increased risk for having cancer detected in subsequent biopsies.
Resumo:
The objective of the current study was to evaluate the sensitivity, specificity and accuracy of fine needle aspiration biopsy (FNAB) of submucous nodules from the oral cavity and head and neck region as an auxiliary diagnostic tool. Fifty patients with nodule lesions in the oral cavity and the head and neck region were selected. All of them were submitted to FNAB and to either incisional or excisional biopsy. The diagnoses from the FNABs were compared with the biopsy diagnosis as the gold standard. All the cases of FNAB were analyzed by a single oral pathologist prior to the biopsy diagnosis. The results showed that the sensitivity of FNAB was 75%, its specificity was 96% and its accuracy was 58.8%. The false positive and false negative rates were 6.7% and 13.3%, respectively. The positive predictive value was 86% and the negative predictive value was 93%. The inconclusive rate was 16/50. FNAB displayed a high success rate for identifying both malignant and benign lesions, but a low accuracy for making a final diagnosis.
Resumo:
Mode of access: Internet.
Resumo:
The recently-proposed Bethesda reporting system has offered clinical recommendations for each category of reported thyroid cytology, including repeated fine-needle aspiration (FNA) for non-diagnostic and atypia/follicular lesions of undetermined significance, but there are no sound indications for repeated examination after an initial benign exam. To investigate the clinical validity of repeated FNA in the management of patients with thyroid nodules. The present study evaluated 412 consecutive patients who had repeated aspiration biopsies of thyroid nodules after an initial non-diagnostic, atypia/follicular lesion of undetermined significance, or benign cytology. The majority of patients were female (93.5%) ranging from 13 to 83 years. Non-diagnostic cytology was the most common indication for a repeated examination in 237 patients (57.5%), followed by benign (36.8%), and A/FLUS (5.6%) cytology. A repeated examination altered the initial diagnosis in 70.5% and 78.3% of the non-diagnostic and A/FLUS patients, respectively, whereas only 28.9% of patients with a benign cytology presented with a different diagnosis on a sequential FNA. Repeat FNA is a valuable procedure in cases with initial non-diagnostic or A/FLUS cytology, but its routine use for patients with an initial benign examination appears to not increase the expected likelihood of a malignant finding.
Resumo:
Objective. There are no data to support the suggestion that samples removed from one segment of the transplanted kidney are representative of the whole graft. The aim of this study was to compare the histological differences between biopsies obtained from different portions of the renal allograft and their impact on treatment recommendations. Patients and Methods. Two hundred percutaneous biopsies were performed on kidney allografts and samples were collected from the upper and lower poles (100 kidneys). All samples were randomized and blindly reviewed. We obtained the discordance rates between the poles for the grading of acute rejection and for the diagnosis of nephrotoxicity due to immunosuppression. We also checked if the differences found were sufficient to call for different clinical recommendations. These values were compared with the intrapathologist variation rates. Results. In 70 kidneys adequate sampling was obtained from both poles. The diagnosis of acute rejection were made in 1.7. The discordance rate between the upper and lower poles was 82.3% (kappa = 0.34), higher than the intrapathologist variation (P =.002). Nephrotoxicity was found in 14 kidneys. The discordance rate between the upper and lower poles was 28.6% (kappa = 0.88), with no difference compared with the intrapathologist variation. In 14 of the 70 kidneys (25.7%), discordances between poles had impact on clinical recommendations, most of these cases due to different gradings of acute rejection (78%). This number was higher than the intrapathologist variation (P =.04). Conclusions. The histopathological changes in the kidney allograft are not always homogeneous. This heterogeneity may affect the therapeutic recommendations.
Resumo:
Introduction: Pediatric percutaneous renal biopsy (Bx) is a routine procedure in pediatric nephrology to obtain renal tissues for histological study. We evaluated the safety, efficacy, indications and renal findings of this procedure at a tertiary care pediatric university hospital and compared our findings with the literature. Methods: Retrospective study based on medical records from January 1993 to June 2006. Results: In the study period, 305 Bx were performed in 262 patients, 127 (48.5%) male, aged 9.8 +/- 4.2 years. A 16-gauge needle was utilized in 56/305 Bx, an 18-gauge needle in 252/305 Bx (82.6%). 56.1% Bx were performed under sedation plus local anesthesia, 43.9% under general anesthesia. The number of punctures per Bx was 3.1 +/- 1.3. Minor complications occurred in 8.6% procedures. The 16-gauge needle caused a higher frequency of renal hematomas (p = 0.05). The number of glomeruli per puncture was >= 5 in 96.7% and >= 7 in 92%. Glomeruli number per puncture and frequency of complications were not different according to the type of anesthesia used. A renal pathology diagnosis was achieved in 93.1% Bx. The main indications of Bx were nephrotic syndrome (NS), lupus nephritis (LN) and hematuria (HE). The diagnosis of minimal change disease (MCD) (61.3%), class V (35.6%) and IgA nephropathy (26.3%) predominated in NS, LN and HE patients, respectively. Conclusion: Pediatric real-time ultrasound-guided percutaneous renal biopsy was safe and effective. The main clinical indications for Bx were NS and LN, the predominant renal pathology diagnoses were MCD and class V LN.
Resumo:
Context.-Studies analyzing the concordance of biopsy and radical prostatectomy (RP) Gleason scores have limitations. Some included 2 or more centers, used historical controls from the early prostate specific antigen era or lacked a clear definition of the biopsy schemes. Furthermore, most did not control the results for prostate volume. Objective.-To confirm whether prediction of RP Gleason score can be optimized by taking more biopsy cores in a contemporary series of patients, with pathologic samples analyzed by the same pathologist, and controlling these results for prostate volume. Design.-The study comprised a retrospective case-control analysis of 393 patients with prostate cancer treated with RP. Patients were divided into 3 groups: those in group 1 underwent a 6-core biopsy; group 2, an 8-core biopsy; and group 3, a 10 or more-core biopsy. Concordance rates between biopsy and RP Gleason scores, as well as the rates of undergrading and overgrading, were determined for each biopsy scheme. Results.-Concordance rates were 60.9%, 58.3%, and 64.6% for patients from groups 1, 2, and 3, respectively (P = .18). When we analyzed patients with prostate volumes of less than 50 cm(3), concordance rates were 58.3%, 58.3%, and 65.1% for each group, respectively (P = .03). Among patients with prostate volumes of 50 cm3 or more, concordance rates were 70%, 58.1%, and 63.6%, respectively (P = .66). Conclusions.-Taking 10 or more cores can improve the prediction of RP Gleason score in patients with prostate volumes of less than 50 cm3. For patients with prostate volumes of 50 cm3 or more, increasing the biopsy cores to 10 or more did not improve prediction of RP Gleason score.
Resumo:
Often in tropical practice there is not time or conditions to do a proper autopsy on a patient who has died. A needle biopsy technique is described for limited closed autopsy examination to clariffy organ histology. In this way the clinician may resolve puzzling fatal disease.
Resumo:
PURPOSE: To report the experience of a radiology department in the use of computed tomography guided biopsies of mediastinal lesions with fine and cutting needles, describing the differences between them. The results of adequacy of the sample and histologic diagnoses are presented according to the type of needle used. METHODS: We present a retrospective study of mediastinal biopsies guided by computed tomography performed from January 1993 to December 1999. Eighty-six patients underwent mediastinal biopsy in this period, 37 with cutting needles, 38 with fine needles, and 11 with both types (total of 97 biopsies). RESULTS: In most cases, it was possible to obtain an adequate sample (82.5%) and specific diagnosis (67.0%). Cutting-needle biopsy produced a higher percentage of adequate samples (89.6% versus 75.5%, P = 0.068) and of specific diagnosis (81.3% versus 53.1%, P = 0.003) than fine-needle biopsy. There were no complications that required intervention in either group. CONCLUSION: Because they are practical, safe, and can provide accurate diagnoses, image-guided biopsies should be considered the procedure of choice in the initial exploration of patients with mediastinal masses. In our experience, cutting needles gave higher quality samples and diagnostic rates. We recommend the use of cutting needles as the preferred procedure.
Resumo:
The development of new therapeutic options for renal tumors has lead to the need of a pretherapeutic diagnosis for an increasing proportion of patients presenting with a renal mass. This need is particularly important for a small, incidentally discovered renal mass (less than 4 cm) as it can be a benign lesion in a significant percentage of cases. Recent studies have shown that needle biopsy is an accurate and safe method allowing for a precise histopathological diagnosis of the mass in most cases. The aims of the biopsy are (1) to assess the benign or malignant nature of the lesion, (2) to assess the primary or secondary nature of the lesion, and (3), in case of a primary malignancy, to determine histological prognostic factors, such as the tumor type. This review, based on the most recent literature and our own experience, is intended to provide a practical approach to the diagnosis, relying on appropriate morphologic assessment and the use of immunohistochemistry.