987 resultados para Motion studies


Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Most economic evaluations of chlamydia screening do not include costs incurred by patients. The objective of this study was to estimate both the health service and private costs of patients who participated in proactive chlamydia screening, using mailed home-collected specimens as part of the Chlamydia Screening Studies project. METHODS: Data were collected on the administrative costs of the screening study, laboratory time and motion studies and patient-cost questionnaire surveys were conducted. The cost for each screening invitation and for each accepted offer was estimated. One-way sensitivity analysis was conducted to explore the effects of variations in patient costs and the number of patients accepting the screening offer. RESULTS: The time and costs of processing urine specimens and vulvo-vaginal swabs from women using two nucleic acid amplification tests were similar. The total cost per screening invitation was 20.37 pounds (95% CI 18.94 pounds to 24.83). This included the National Health Service cost per individual screening invitation 13.55 pounds (95% CI 13.15 pounds to 14.33) and average patient costs of 6.82 pounds (95% CI 5.48 pounds to 10.22). Administrative costs accounted for 50% of the overall cost. CONCLUSIONS: The cost of proactive chlamydia screening is comparable to those of opportunistic screening. Results from this study, which is the first to collect private patient costs associated with a chlamydia screening programme, could be used to inform future policy recommendations and provide unique primary cost data for economic evaluations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Utilizing advanced information technology, Intensive Care Unit (ICU) remote monitoring allows highly trained specialists to oversee a large number of patients at multiple sites on a continuous basis. In the current research, we conducted a time-motion study of registered nurses’ work in an ICU remote monitoring facility. Data were collected on seven nurses through 40 hours of observation. The results showed that nurses’ essential tasks were centered on three themes: monitoring patients, maintaining patients’ health records, and managing technology use. In monitoring patients, nurses spent 52% of the time assimilating information embedded in a clinical information system and 15% on monitoring live vitals. System-generated alerts frequently interrupted nurses in their task performance and redirected them to manage suddenly appearing events. These findings provide insight into nurses’ workflow in a new, technology-driven critical care setting and have important implications for system design, work engineering, and personnel selection and training.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hoje em dia, com os avanços constantes na indústria, novas áreas começam cada vez mais a ser foco de atenção por parte das organizações. Motivados pela procura de melhores condições para os seus colaboradores e por todos os benefícios que este tipo de intervenção oferece, tanto a curto, como principalmente a médio e longo prazo, a Grohe Portugal, mais especificamente o seu departamento de montagem, achou relevante potenciar a aplicação da Ergonomia nos seus postos de trabalho. Posto isto, esta dissertação pretende apresentar o trabalho desenvolvido junto da organização que teve como objetivo projetar e executar uma linha de montagem que tivesse em consideração os seguintes aspetos: • Ergonomia; • Automatização ou semi-automatização de operações; • Simplificação de aspetos operacionais; • Sistemas de abastecimento mais robustos e de fácil uso; • Simplificação de setups; • Definição de dimensões normalizadas para futuros projetos. As soluções encontradas tiveram como objetivo primordial satisfazer o maior número possível de colaboradores, sendo que para tal foram utilizados dados referentes a antropometria da população Portuguesa. Para a realização e conclusão deste projeto, o trabalho foi decomposto em varias etapas, de entre as quais se destacam: • Analise e estudo dos métodos de montagem; • Levantamento de todos os componentes e operações que constituem o processo de fabrico das diversas famílias onde foram implementados novos projetos; • Definição e uniformização da estrutura das novas linhas de montagem; • Estudo e definição da disposição dos componentes na nova linha, bem como da sua forma de abastecimento; • Projeto da linha de montagem em 3D com recurso ao software SolidWorks (DassaultSystemes, 2014); • Montagem final da linha, bem como o acompanhamento da sua fase de arranque. Durante o estagio foi ainda pensado e implementado um projeto paralelo com vista a constante manutenção e melhoria do departamento de montagem cujo objetivo, através de “plant walks”, e detetar de entre outras, situações de falta de identificação de componentes ou equipamentos, degradação de ferramentas, fugas ou derrames nas linhas, etc. O balanco final do trabalho foi bastante positivo, tendo-se alcançado melhorias em alguns índices de qualidade, tempos de abastecimento e condições ergonómicas dos postos de trabalho que sofreram intervenção, tendo essas melhorias resultado numa avaliação positiva por parte dos colaboradores que integram essas mesmas linhas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Robot surgery is a further step towards new potential developments in minimally invasive surgery. Surgeons must keep abreast of these new technologies and learn their limits and possibilities. Robot-assisted laparoscopic cholecystectomy has not yet been performed in our institution. The purpose of this report is to present the pathway of implementation of robotic laparoscopic cholecystectomy in a university hospital. METHODS: The Zeus(R) robot system was used. Experimental training was performed on animals. The results of our experimental training allowed us to perform our first two clinical cases. RESULTS: Robot arm set-up and trocar placement required 53 and 35 minutes. Operative time were 59 and 45 minutes respectively. The overall operative time was 112 and 80 minutes, respectively. There were no intraoperative complications. Patients were discharged from the hospital after an overnight stay. CONCLUSION: Robotic laparoscopic cholecystectomy is safe and patient recovery similar to those of standard laparoscopy. At present, there are no advantages of robotic over conventional surgery. Nevertheless, robots have the potential to revolutionise the way surgery is performed. Robot surgery is not reserved for a happy few. This technology deserves more attention because it has the potential to change the way surgery is performed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tutkimus tehtiin STX Finlandin Turun telakalle osana suurempaa kehitysohjelmaa, joka tähtää läpimenoaikojen lyhentämiseen ja kilpailukyvyn paranemiseen. Työntutkimuksesta saatujen tietojen avulla toimintaa pyritään kehittämään tuottavammaksi ja läpimenoaikaa lyhyemmäksi. Työssä pyrittiin löytämään valmistusteknillisiä keinoja läpimenoajan lyhentämiseksi käyttäen hyväksi Lean-ajattelutapaa. Mittaustuloksista voidaan nähdä, miten aika jakaantuu lohkonkoonnissa ja mihin aikaa hukataan. Tuloksista huomataan, että lisäarvoa tuottavan työn osuutta työajasta voidaan lisätä. Kasvattamalla jalostavan työn osuutta voidaan tuotannosta tehdä tehokkaampaa ja läpimenoaikaa lyhentää. Tuloksista selviää, minkälaisia Lean-ajattelutavan hukkia työvaiheet sisältävät ja kuinka paljon aikaa niihin kuluu. Tutkimus tehtiin tunnettuja työntutkimuksen keinoja hyväksikäyttäen. Käytössä oli havainnointitutkimus sekä ajankäyttötutkimus. Havainnointitutkimuksen avulla saatiin selville tuotannon epäkohtia. Työntutkimuksen avulla selvisi myös, ettei mekanisointien käyttö hitsauksessa ole riittävällä tasolla. Suuri osa hitsauksesta tehdään manuaalisesti ilman kuljettimia, jolloin paloaikasuhde pysyy matalana. Tuotannossa esiintyvät virheet jäävät liian usein raportoimatta. Tutkimuksessa on esitetty toimintamalli tuotannon epäkohtien raportoinnin toteutukselle. Johtopäätöksinä syntyi kehitysideoita lohkovalmistuksen tehostamiseksi. Tutkimuksen avulla luotiin pohja työntutkimuksen uudelleenkäynnistämiselle. Luotuja työntutkimuskaavioita voidaan käyttää tulevissa työntutkimuksissa. Johtopäätöksinä syntyi kehitysideoita lohkovalmistuksen tehostamiseksi. Menetelmien avulla lohkovalmistuksen läpimenoaikaa saadaan tehostettua.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To verify whether the number of chewing strokes and the chewing time are influenced by dentofacial deformities in habitual free mastication. METHODS: Participants were 15 patients with diagnosis of class II dentofacial deformity (GII), 15 with class III (GIII), and 15 healthy control individuals with no deformity (CG). Free habitual mastication of a cornstarch cookie was analyzed, considering the number of chewing strokes and the time needed to complete two mastications. Strokes were counted by considering the opening and closing movements of the mandible. The time needed to consume each bite was determined using a digital chronometer, started after the placement of the food in the oral cavity and stopped when each portion was swallowed. RESULTS: There were no differences between groups regarding both the number of strokes and the chewing time. However, with regards to the number of strokes, CG and GII presented a significant concordance between the first and the second chewing situation, which was not observed in GIII. The analysis of time showed significant concordance between the first and second chewing situation in CG, reasonable concordance in GII, and discordance in GIII. CONCLUSION: Dentofacial deformities do not influence the number of chewing strokes or the chewing time. However, class III individuals do not show uniformity regarding these aspects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. Childhood immunization programs have dramatically reduced the morbidity and mortality associated with vaccine-preventable diseases. Proper documentation of immunizations that have been administered is essential to prevent duplicate immunization of children. To help improve documentation, immunization information systems (IISs) have been developed. IISs are comprehensive repositories of immunization information for children residing within a geographic region. The two models for participation in an IIS are voluntary inclusion, or "opt-in," and voluntary exclusion, or "opt-out." In an opt-in system, consent must be obtained for each participant, conversely, in an opt-out IIS, all children are included unless procedures to exclude the child are completed. Consent requirements for participation vary by state; the Texas IIS, ImmTrac, is an opt-in system.^ Objectives. The specific objectives are to: (1) Evaluate the variance among the time and costs associated with collecting ImmTrac consent at public and private birthing hospitals in the Greater Houston area; (2) Estimate the total costs associated with collecting ImmTrac consent at selected public and private birthing hospitals in the Greater Houston area; (3) Describe the alternative opt-out process for collecting ImmTrac consent at birth and discuss the associated cost savings relative to an opt-in system.^ Methods. Existing time-motion studies (n=281) conducted between October, 2006 and August, 2007 at 8 birthing hospitals in the Greater Houston area were used to assess the time and costs associated with obtaining ImmTrac consent at birth. All data analyzed are deidentified and contain no personal information. Variations in time and costs at each location were assessed and total costs per child and costs per year were estimated. The cost of an alternative opt-out system was also calculated.^ Results. The median time required by birth registrars to complete consent procedures varied from 72-285 seconds per child. The annual costs associated with obtaining consent for 388,285 newborns in ImmTrac's opt-in consent process were estimated at $702,000. The corresponding costs of the proposed opt-out system were estimated to total $194,000 per year. ^ Conclusions. Substantial variation in the time and costs associated with completion of ImmTrac consent procedures were observed. Changing to an opt-out system for participation could represent significant cost savings. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Interim clinical trial monitoring procedures were motivated by ethical and economic considerations. Classical Brownian motion (Bm) techniques for statistical monitoring of clinical trials were widely used. Conditional power argument and α-spending function based boundary crossing probabilities are popular statistical hypothesis testing procedures under the assumption of Brownian motion. However, it is not rare that the assumptions of Brownian motion are only partially met for trial data. Therefore, I used a more generalized form of stochastic process, called fractional Brownian motion (fBm), to model the test statistics. Fractional Brownian motion does not hold Markov property and future observations depend not only on the present observations but also on the past ones. In this dissertation, we simulated a wide range of fBm data, e.g., H = 0.5 (that is, classical Bm) vs. 0.5< H <1, with treatment effects vs. without treatment effects. Then the performance of conditional power and boundary-crossing based interim analyses were compared by assuming that the data follow Bm or fBm. Our simulation study suggested that the conditional power or boundaries under fBm assumptions are generally higher than those under Bm assumptions when H > 0.5 and also matches better with the empirical results. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Design. A comparative study of cervical range of motion in asymptomatic persons and those with whiplash. Objectives. To compare the primary and conjunct ranges of motion of the cervical spine in asymptomatic persons and those with persistent whiplash-associated disorders, and to investigate the ability of these measures of range of motion to discriminate between the groups. Summary of Background. Evidence that range of motion is an effective indicator of physical impairment in the cervical spine is not conclusive. Few studies have evaluated the ability to discriminate between asymptomatic persons and those with whiplash on the basis of range of motion or compared three-dimensional in vivo measures of range of motion in asymptomatic persons and those with whiplash-associated disorders. Methods. The study participants were 89 asymptomatic volunteers (41 men, 48 women; mean age 39.2 years) and 114 patients with persistent whiplash-associated disorders (22 men, 93 women; mean age 37.2 years) referred to a whiplash research unit for assessment of their cervical region. Range of cervical motion was measured in three dimensions with a computerized, electromagnetic, motion-tracking device. The movements assessed were flexion, extension, left and right lateral flexion, and left and right rotation. Results. Range of motion was reduced in all primary movements in patients with persistent whiplash-associated disorder. Sagittal plane movements were proportionally the most affected. On the basis of primary and conjunct range of motion, age, and gender, 90.3% of study participants could be correctly categorized as asymptomatic or as having whiplash (sensitivity 86.2%, specificity 95.3%). Conclusions. Range of motion was capable of discriminating between asymptomatic persons and those with persistent whiplash-associated disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Motion study is an engineering technology that analyzes human body motions. During the past decade (1990-1999) a series of studies investigated the role of motion study in developmental disabilities. This article reviews the literature on the applications of motion study in the field. A historical and conceptual review of motion study leading to the current status of studies is presented followed by a review of the research literature. Two main eras of research focus were identified. The first era (1990-1995) of studies established the superior effectiveness and efficiency of tasks designed with motion study or motion study-related principles over traditional site-based task designs. The second era (1995-1999) of studies examined the interaction between motion study-based task designs and other variables such as choice, preference, and functionally equivalent and competing task designs and communicative alternatives. Our review found that applying motion study principles as an antecedent guide and practice to eliminating or reducing ineffective motions and simplifying effective motions resulted in positive task outcomes with most of the participants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to increased interest in in vivo small animal imaging. Small animal imaging has been applied frequently to the imaging of small animals (mice and rats), which are ubiquitous in modeling human diseases and testing treatments. The use of PET in small animals allows the use of subjects as their own control, reducing the interanimal variability. This allows performing longitudinal studies on the same animal and improves the accuracy of biological models. However, small animal PET still suffers from several limitations. The amounts of radiotracers needed, limited scanner sensitivity, image resolution and image quantification issues, all could clearly benefit from additional research. Because nuclear medicine imaging deals with radioactive decay, the emission of radiation energy through photons and particles alongside with the detection of these quanta and particles in different materials make Monte Carlo method an important simulation tool in both nuclear medicine research and clinical practice. In order to optimize the quantitative use of PET in clinical practice, data- and image-processing methods are also a field of intense interest and development. The evaluation of such methods often relies on the use of simulated data and images since these offer control of the ground truth. Monte Carlo simulations are widely used for PET simulation since they take into account all the random processes involved in PET imaging, from the emission of the positron to the detection of the photons by the detectors. Simulation techniques have become an importance and indispensable complement to a wide range of problems that could not be addressed by experimental or analytical approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The diaphragm is a muscular membrane separating the abdominal and thoracic cavities, and its motion is directly linked to respiration. In this study, using data from a 59-year-old female cadaver obtained from the Visible Human Project, the diaphragm is reconstructed and, from the corresponding solid object, a shell finite element mesh is generated and used in several analyses performed with the ABAQUS 6.7 software. These analyses consider the direction of the muscle fibres and the incompressibility of the tissue. The constitutive model for the isotropic strain energy as well as the passive and active strain energy stored in the fibres is adapted from Humphrey's model for cardiac muscles. Furthermore, numerical results for the diaphragmatic floor under pressure and active contraction in normal and pathological cases are presented.