968 resultados para Molecular imprinted polymer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The relentless discovery of cancer biomarkers demands improved methods for their detection. In this work, we developed protein imprinted polymer on three-dimensional gold nanoelectrode ensemble (GNEE) to detect epithelial ovarian cancer antigen-125 (CA 125), a protein biomarker associated with ovarian cancer. CA 125 is the standard tumor marker used to follow women during or after treatment for epithelial ovarian cancer. The template protein CA 125 was initially incorporated into the thin-film coating and, upon extraction of protein from the accessible surfaces on the thin film, imprints for CA 125 were formed. The fabrication and analysis of the CA 125 imprinted GNEE was done by using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. The surfaces of the very thin, protein imprinted sites on GNEE are utilized for immunospecific capture of CA 125 molecules, and the mass of bound on the electrode surface can be detected as a reduction in the faradic current from the redox marker. Under optimal conditions, the developed sensor showed good increments at the studied concentration range of 0.5–400 U mL−1. The lowest detection limit was found to be 0.5 U mL−1. Spiked human blood serum and unknown real serum samples were analyzed. The presence of non-specific proteins in the serum did not significantly affect the sensitivity of our assay. Molecular imprinting using synthetic polymers and nanomaterials provides an alternative approach to the trace detection of biomarker proteins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molecularly imprinted polymers (MIP) were used as potentiometric sensors for the selective recognition and determination of chlormequat (CMQ). They were produced after radical polymerization of 4-vinyl pyridine (4-VP) or methacrylic acid (MAA) monomers in the presence of a cross-linker. CMQwas used as template. Similar nonimprinted (NI) polymers (NIP) were produced by removing the template from reaction media. The effect of kind and amount of MIP or NIP sensors on the potentiometric behavior was investigated. Main analytical features were evaluated in steady and flow modes of operation. The sensor MIP/4-VP exhibited the best performance, presenting fast near-Nernstian response for CMQover the concentration range 6.2×10-6 – 1.0×10-2 mol L-1 with detection limits of 4.1×10-6 mol L-1. The sensor was independent from the pH of test solutions in the range 5 – 10. Potentiometric selectivity coefficients of the proposed sensors were evaluated over several inorganic and organic cations. Results pointed out a good selectivity to CMQ. The sensor was applied to the potentiometric determination of CMQin commercial phytopharmaceuticals and spiked water samples. Recoveries ranged 96 to 108.5%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molecular imprinting is a useful technique for the preparation of functional materials with molecular recognition properties. A Biomimetic Sensor Potentiometric System was developed for assessment of doxycycline (DOX) antibiotic. The molecularly imprinted polymer (MIP) was synthesized by using doxycycline as a template molecule, methacrylic acid (MAA) and/or acrylamide (AA) as a functional monomer and ethylene glycol dimethacrylat (EGDMA) as a cross-linking agent. The sensing elements were fabricated by the inclusion of DOX imprinted polymers in polyvinyl chloride (PVC) matrix. The sensors showed a high selectivity and a sensitive response to the template in aqueous system. Electrochemical evaluation of these sensors under static (batch) mode of operation reveals near-Nernstian response. MIP/MAA membrane sensor was incorporated in flow-through cells and used as detectors for flow injection analysis (FIA) of DOX. The method has the requisite accuracy, sensitivity and precision to assay DOX in tablets and biological fluids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The grafting of functional brushes on the surface of molecularly imprinted polymer (MIP). particles hás been explored in the last few years to synthesize materiais combining high molecular recognition capabilities and stimulation triggered by changes in the surrounding environment [1, 2]. In the present work, MIP particles for 5-fluorouracil (a drug used in câncer treatment) were produced by precipitation polymerization in acetonitrile, using either MAA or HEMA as imprinting fünctional monomers, and m the presence of different kinds of RAFT agents. In a second step, taking advantage of the RAFT groups present in the surface of the particles, different kinds of fiinctional polymer brushes were grafted on the MIPs considering a "grafting from" process in the presence of a RAFT agent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

6th Graduate Student Symposium on Molecular Imprinting

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tailored ion imprinted polymer materials for the preconcentrative separation of noble metals. This study deals with the synthesis, separation,characterization and analytical application of the noble metals especially palladium and platinum. Platinum group metals(PGM) are currently receiving world wide attention. This group include Palladium(Pt),rhodium(Rh), ruthenium(Ru), iridium(Ir) and osmium(Os).PGM are used as catalysts for a wide variety of hydrogenation, oxidation, isomerization,cyclization,dehydrogenation and dehalogenation reactions.The corrosion resistance of PGM enables them to use in jewellery,electrical and glass industries,extrusion of synthetic fibres,manufacture of laboratory utensils,dental and medical devices. This study clearly establishes selective recovery of platinum from other noble and transition elements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Guanosine 3′,5′-cyclic monophosphate (cGMP) plays a role as a second messenger in many different biological systems. Given the ubiquitous nature of cGMP, a simple method of detecting cGMP is of interest. To that end a fluorescent polymer with recognition sites for cGMP has been prepared. Its selectivity and sensitivity were investigated and a dose-dependant decrease in fluorescence of the polymer in the presence of cGMP was observed. In contrast, virtually no effect was detected upon application of the structurally similar molecules, guanosine 5′-monophosphate (GMP) and adenosine 3′,5′-cyclic monophosphate (cAMP), thus demonstrating the high selectivity of this polymer. The association constant for the binding of cGMP to the imprinted polymer was determined in order of 3 × 10 5 M -1. A fluorescent, molecularly imprinted polymer that selectively recognises cGMP may have a useful application as a fluorescent chemosensor for cGMP detection in biological samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this thesis is to evaluate the possibility of using short linear polymer chains as additives in lubricating oil applications. Through previous works, it has been seen that they are particularly resistant to mechanical degradation, which is the main reason why lubricating oils need to be changed after a while. This is the main reason why they could be proposed as alternatives in the market. The results of this work have been split into two major phases: the first concentrated on characterizing a target product obtained through thermal degradation, starting from the original long chain parent polymer, and the second focused on the technological advancement of heat exchangers. Through the studies carried out, we’ve characterized our innovative polymers and the solutions made with them and base oil at different concentrations. The most promising result is that these short random coiled polymeric chains obey to a more general universal function which express the value of specific viscosity as function of a dimensionless quantity c/c*. For the design of the unit operation, several alternatives were proposed and these all shared the same final goal: cooling the polymer without the presence of oxygen to avoid oxidation and formation of unwanted substances. We’ve analyzed the main difficulties related to the presence of these highly viscous substances and, more importantly, how to deal with this situation (e.g. by considering radial static mixer or even more complex conformations).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A furazolidona é uma substância ativa do medicamento Giarlam que contém um espetro anti-bacteriano relativamente amplo e que é frequentemente usado para tratar certas doenças bacterianas e protozoárias no homem. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabólitos exige o desenvolvimento constante de métodos analíticos eficientes. Neste trabalho desenvolveu-se um novo sensor eletroquímico para a deteção da furazolidona, baseado num elétrodo de pasta de carbono modificado com um polímero molecularmente impresso. A procura de novos materiais que permitam uma melhor seletividade e sensibilidade aos sistemas de deteção é especialmente importante no desenvolvimento de métodos analíticos. Os polímeros molecularmente impressos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais frequente como ferramenta importante em química analítica. Assim, sintetizou-se um polímero com cavidades seletivas para a Furazolidona. Este polímero foi, misturado com grafite e perafina de modo a produzir uma pasta de carbono. Uma seringa de plástico foi usada como suporte da pasta de carbono. O comportamento eletroquímico do sensor foi avaliado e diversas condições de utilização foram estudadas e otimizadas. O sensor apresenta um comportamento linear entre a intensidade do pico e a concentração numa gama de concentrações entre 1 e 100 μM, um limite de deteção de 1 μM e uma precisão (repetibilidade) inferior a 7%. A aplicabilidade do sensor fabricado em amostras complexas foi avaliada pela deteção do fármaco em amostras de urina.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le vétérinaire aide le producteur laitier à garder son troupeau en santé. Lorsqu’une vache est malade, il peut prescrire des antibiotiques. Le cas échéant, le lait de la vache traitée aux antibiotiques est jeté. Il n’est donc pas vendu pour consommation. Tout le lait produit est analysé avant d’être pasteurisé et transformé afin de s’assurer que les produits laitiers ne contiennent pas de résidus d’antibiotiques. Si les analyses indiquent que le lait renferme des traces d’antibiotiques, il est jeté et le producteur en cause doit assumer la perte. Les épreuves de dépistage actuelles de ces résidus médicamenteux sont onéreuses et inapplicables sur le terrain. Pour résoudre cette problématique aux pieds de la vache, la solution proposée dans ce projet est la fabrication d’un kit de détection basé sur les polymères à empreinte moléculaire. Il s’agit de polymères dont la conformation moléculaire est complémentaire à celle des antibiotiques. Dans ce projet, il est question d’améliorer l’efficacité des épreuves de dépistages des résidus de tétracyclines en augmentant le nombre de sites d’interaction entre l’antibiotique et des polyesters. Trois polymères sont utilisés portant respectivement des groupements aromatiques, carboxyliques et hydroxyles. Une étude antérieure dans notre laboratoire avait déjà donné un pourcentage de rétention de tétracycline de 50% pour une composition de 1/3 PLAOH- 1/3 PLACOOH- 1/3 PLAOBn. Avec des ajustements, le pourcentage passe à 38.93 % pour une composition de 1/4 PLAOH- 1/2 PLACOOH- 1/4 PLAOPh, de 44.81 % pour une composition de 1/4 PLACOOH- 1/2 PLAOH- 1/4 PLAOPh, de 66.34 %pour une composition de 1/4 PLAOH- 1/4 PLACOOH- 1/2 PLAOPh et de 78.07 % pour une composition de 1/6 PLAOH- 1/6 PLACOOH- 2/3 PLAOPh. Notre hypothèse était que la présence accrue du groupement phényle augmenterait le nombre de sites d’interaction spécifique avec l’antibiotique augmentant ainsi le pourcentage de rétention de l’antibiotique à travers les MIP. Les résultats ont confirmé cette hypothèse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The behaviour and fate of spilled oil in harsh marine environments, such as the North Atlantic and the Arctic Ocean are complex due to environmental factors and the composition of the crude. In order to develop appropriate oil spill prevention and management methods, we must first understand how the oil behaves in these harsh environmental conditions. This study focuses on determining the fate of oil in harsh marine environments by first identifying target compounds in the oil that can be used to determine the fate of a spill. This thesis presents the partitioning behaviour of six polycyclic aromatic hydrocarbons (PAHs), which represent different groups, and phenols in cold conditions. The smallest PAH, naphthalene, dominated in terms of concentration in water accommodated fraction (WAF) of oil, while the larger ringed PAHs presented at lower concentrations. The smallest oil-water partition coefficient was recorded by phenol which partitioned into the seawater more quickly than PAHs. The partitioning of larger PAHs was slower and they indicated high partition coefficients. The oil partitioning increased slightly as temperature increased from 4ᴼC to 15ᴼC. The oil loading (0.1 g/L to 10 g/L) also contributed in deciding the concentrations in water. The use of chemical dispersants is a common response to spills. This study identified that chemical dispersants can change the fate of an oil spill by increasing the availability of oil in seawater. The concentration of larger PAHs such as pyrene and chrysene increased significantly with the application of dispersants. The information obtained are used in developing a molecular imprinted polymer (MIP) sensor to identify oil spills in the North Atlantic Ocean.