23 resultados para Microdevices
Resumo:
The possibility of manufacturing textured materials and devices, with surface properties controlled from the design stage, instead of being the result of machining processes or chemical attacks, is a key factor for the incorporation of advanced functionalities to a wide set of micro and nanosystems. Recently developed high-precision additive manufacturing technologies, together with the use of fractal models linked to computer-aided design tools, allow for a precise definition and control of final surface properties for a wide set of applications, although the production of larger series based on these resources is still an unsolved challenge. However, rapid prototypes, with controlled surface topography, can be used as original masters for obtaining micromold inserts for final large-scale series manufacture of replicas using microinjection molding. In this study, an original procedure is presented, aimed at connecting rapid prototyping with microinjection molding, for the mass production of two different microtextured microsystems, linked to tissue engineering tasks, using different thermoplastics as ultimate materials.
Resumo:
The possibility of designing and manufacturing biomedical microdevices with multiple length-scale geometries can help to promote special interactions both with their environment and with surrounding biological systems. These interactions aim to enhance biocompatibility and overall performance by using biomimetic approaches. In this paper, we present a design and manufacturing procedure for obtaining multi-scale biomedical microsystems based on the combination of two additive manufacturing processes: a conventional laser writer to manufacture the overall device structure, and a direct-laser writer based on two-photon polymerization to yield finer details. The process excels for its versatility, accuracy and manufacturing speed and allows for the manufacture of microsystems and implants with overall sizes up to several millimeters and with details down to sub-micrometric structures. As an application example we have focused on manufacturing a biomedical microsystem to analyze the impact of microtextured surfaces on cell motility. This process yielded a relevant increase in precision and manufacturing speed when compared with more conventional rapid prototyping procedures.
Resumo:
We present a method for characterizing microscopic optical force fields. Two dimensional vector force maps are generated by measuring the optical force applied to a probe particle for a grid of particle positions. The method is used to map Out the force field created by the beam from a lensed fiber inside a liquid filled microdevice. We find transverse gradient forces and axial scattering forces on the order of 2 pN per 10 mW laser power which are constant over a considerable axial range (> 35 mu m). These findings suggest Future useful applications of lensed fibers for particle guiding/sorting. The propulsion of a small particle at a constant velocity of 200 mu m s(-1) is shown.
Resumo:
Tese de Doutoramento (Programa Doutoral em Engenharia Biomédica)
Resumo:
This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.
Resumo:
A wide variety of whole cell bioreporter and biosensor assays for arsenic detection has been developed over the past decade. The assays permit flexible detection instrumentation while maintaining excellent method of detection limits in the environmentally relevant range of 10-50 μg arsenite per L and below. New emerging trends focus on genetic rewiring of reporter cells and/or integration into microdevices for more optimal detection. A number of case studies have shown realistic field applicability of bioreporter assays.
Resumo:
A variety of substrates have been used for fabrication of microchips for DNA extraction, PCR amplification, and DNA fragment separation, including the more conventional glass and silicon as well as alternative polymer-based materials. Polyester represents one such polymer, and the laser-printing of toner onto polyester films has been shown to be effective for generating polyester-toner (PeT) microfluidic devices with channel depths on the order of tens of micrometers. Here, we describe a novel and simple process that allows for the production of multilayer, high aspect-ratio PeT microdevices with substantially larger channel depths. This innovative process utilizes a CO(2) laser to create the microchannel in polyester sheets containing a uniform layer of printed toner, and multilayer devices can easily be constructed by sandwiching the channel layer between uncoated cover sheets of polyester containing precut access holes. The process allows the fabrication of deep channels, with similar to 270 mu m, and we demonstrate the effectiveness of multilayer PeT microchips for dynamic solid phase extraction (dSPE) and PCR amplification. With the former, we found that (i) more than 65% of DNA from 0.6 mu L of blood was recovered, (ii) the resultant DNA was concentrated to greater than 3 ng/mu L., (which was better than other chip-based extraction methods), and (iii) the DNA recovered was compatible with downstream microchip-based PCR amplification. Illustrative of the compatibility of PeT microchips with the PCR process, the successful amplification of a 520 bp fragment of lambda-phage DNA in a conventional thermocycler is shown. The ability to handle the diverse chemistries associated with DNA purification and extraction is a testimony to the potential utility of PeT microchips beyond separations and presents a promising new disposable platform for genetic analysis that is low cost and easy to fabricate.
Resumo:
In this article, the authors measure throughput of sonic diamond microtubes and micronozzles that can work as passive gas flow controllers and flow meters under choking conditions. The behavior of the outlet pressure through the microdevices using an experimental setup with constant volume and constant temperature was determined in order to obtain the critical throughput, the critical mass flow rate, and the discharge coefficients of the diamond sonic microdevices. © 2007 American Vacuum Society.
Resumo:
Supercritical Emulsion Extraction technology (SEE-C) was proposed for the production of poly-lactic-co-glycolic acid microcarriers. SEE-C operating parameters as pressure, temperature and flow rate ratios were analyzed and the process performance was optimized in terms of size distribution and encapsulation efficiency. Microdevices loaded with bovine serum insulin were produced with different sizes (2 and 3 µm) or insulin charges (3 and 6 mg/g) and with an encapsulation efficiency of 60%. The microcarriers were characterized in terms of insulin release profile in two different media (PBS and DMEM) and the diffusion and degradation constants were also estimated by using a mathematical model. PLGA microdevices were also used in a cultivation of embryonic ventricular myoblasts (cell line H9c2 obtained from rat) in a FBS serum free medium to monitor cell viability and growth in dependence of insulin released. Good cell viability and growth were observed on 3 µm microdevices loaded with 3 mg/g of insulin. PLGA microspheres loaded with growth factors (GFs) were charged into alginate scaffold with human Mesenchimal Steam Cells (hMSC) for bone tissue engineering with the aim of monitoring the effect of the local release of these signals on cells differentiation. These “living” 3D scaffolds were incubated in a direct perfusion tubular bioreactor to enhance nutrient transport and exposing the cells to a given shear stress. Different GFs such as, h-VEGF, h-BMP2 and a mix of two (ratio 1:1) were loaded and alginate beads were recovered from dynamic (tubular perfusion system bioreactor) and static culture at different time points (1st, 7th, 21st days) for the analytical assays such as, live/dead; alkaline phosphatase; osteocalcin; osteopontin and Van Kossa Immunoassay. The immunoassay confirmed always a better cells differentiation in the bioreactor with respect to the static culture and revealed a great influence of the BMP-2 released in the scaffold on cell differentiation.
Resumo:
An implantable transducer for monitoring the flow of Cerebrospinal fluid (CSF) for the treatment of hydrocephalus has been developed which is based on measuring the heat dissipation of a local thermal source. The transducer uses passive telemetry at 13.56 MHz for power supply and read out of the measured flow rate. The in vitro performance of the transducer has been characterized using artificial Cerebrospinal Fluid (CSF) with increased protein concentration and artificial CSF with 10\% fresh blood. After fresh blood was added to the artificial CSF a reduction of flow rate has been observed in case that the sensitive surface of the flow sensor is close to the sedimented erythrocytes. An increase of flow rate has been observed in case that the sensitive surface is in contact with the remaining plasma/artificial CSF mix above the sediment which can be explained by an asymmetric flow profile caused by the sedimentation of erythrocythes having increased viscosity compared to artificial CSF. After removal of blood from artificial CSF, no drift could be observed in the transducer measurement which could be associated to a deposition of proteins at the sensitive surface walls of the packaged flow transducer. The flow sensor specification requirement of +-10\% for a flow range between 2 ml/h and 40 ml/h. could be confirmed at test conditions of 37 degrees C.
ALTERNATING CURRENT DIELECTROPHORETIC MANIPULATION OF ERYTHROCYTES IN MEDICAL MICRODEVICE TECHNOLOGY
Resumo:
Medical microdevices have gained popularity in the past few decades because they allow the medical laboratory to be taken out into the field and for disease diagnostics to happen with a smaller sample volume, at a lower cost and much faster. Blood is the human body's most readily available and informative diagnostic fluid because of the wealth of information it provides about the body's general health including enzymatic, proteomic and immunological states. The purpose of this project is to optimize operating conditions and study ABO-Rh erythrocytes dielectrophoretic responses to alternating current electric signals. The end goal of this project is the creation of a relatively inexpensive microfluidic device, which can be used for the ABO-Rh typing of a blood sample. This dissertation presents results showing how blood samples of a known ABO- Rh blood type exhibit differing behavior to the same electrical stimulus based on their blood type. The first panel of donors and experiments, presented in Chapter 4 occurred when a sample of known blood type was injected into a microdevice with a T-shaped electrode configuration and the erythorcytes were found to rupture at a rate specific to their ABO-Rh blood type. The second set of experiments, presented in Chapter 5, were originally published in Electrophoresis in 20111. Novel in this work was the discovery that treatment of human erythrocytes with β-galactosidase successfully removed ABO surface antigens such that native A and B blood no longer agglutinated with the proper antibodies. This work was performed in a medium of conductivity 0.9S/m which is close to the measured conductivity of pooled plasma (~1.1S/m). The ability to perform dielectrophoresis experiments at physiological conductivities conditions is advantageous for future portable devices because the device/instrument would not need to store dilution buffers. The final results of this project, presented in Chapter 6, explore the entire dielectrophoretic spectra of the ABO-Rh erythrocytes including the cross-over frequency and the magnitudes of the positive or negative dielectrophoretic response. These were completed at lower medium conductivities of 0.1S/m and 0.01-0.04S/m. These results show that by using the sweep function built into the Agilent alternating current generator it is possible to explore how a single group of blood cells will react to rapid changes in frequency and will provide the user with curve that can be matched the theoretical dielectrophoretic response curves. As a whole this project shows that it is possible to distinguish human erythrocytes by their ABO-Rh blood type via three different dielectrophoretic methods. This work builds on the foundation of that it is possible to distinguish healthy from infected cells2-7, similar cell types1,7-14 and other work regarding the dielectrophoresis of human erythrocytes1,10,11. This work has implications in both medical diagnostics and future dielectrophoretic work because it has shown that ABO-Rh blood type is now a factor, which must be identified when working with a human blood sample. It also shows that the creation of a microfluidic device that subjects human erythrocytes to a dielectrophoretic impulse and then exports an ABO-Rh blood type is a near future possibility.
Resumo:
The use of biomarkers to infer drug response in patients is being actively pursued, yet significant challenges with this approach, including the complicated interconnection of pathways, have limited its application. Direct empirical testing of tumor sensitivity would arguably provide a more reliable predictive value, although it has garnered little attention largely due to the technical difficulties associated with this approach. We hypothesize that the application of recently developed microtechnologies, coupled to more complex 3-dimensional cell cultures, could provide a model to address some of these issues. As a proof of concept, we developed a microfluidic device where spheroids of the serous epithelial ovarian cancer cell line TOV112D are entrapped and assayed for their chemoresponse to carboplatin and paclitaxel, two therapeutic agents routinely used for the treatment of ovarian cancer. In order to index the chemoresponse, we analyzed the spatiotemporal evolution of the mortality fraction, as judged by vital dyes and confocal microscopy, within spheroids subjected to different drug concentrations and treatment durations inside the microfluidic device. To reflect microenvironment effects, we tested the effect of exogenous extracellular matrix and serum supplementation during spheroid formation on their chemotherapeutic response. Spheroids displayed augmented chemoresistance in comparison to monolayer culturing. This resistance was further increased by the simultaneous presence of both extracellular matrix and high serum concentration during spheroid formation. Following exposure to chemotherapeutics, cell death profiles were not uniform throughout the spheroid. The highest cell death fraction was found at the center of the spheroid and the lowest at the periphery. Collectively, the results demonstrate the validity of the approach, and provide the basis for further investigation of chemotherapeutic responses in ovarian cancer using microfluidics technology. In the future, such microdevices could provide the framework to assay drug sensitivity in a timeframe suitable for clinical decision making.
Resumo:
We report the fabrication, functionalization and testing of microdevices for cell culture and cell traction force measurements in three-dimensions (3D). The devices are composed of bent cantilevers patterned with cell-adhesive spots not lying on the same plane, and thus suspending cells in 3D. The cantilevers are soft enough to undergo micrometric deflections when cells pull on them, allowing cell forces to be measured by means of optical microscopy. Since individual cantilevers are mechanically independent of each other, cell traction forces are determined directly from cantilever deflections. This proves the potential of these new devices as a tool for the quantification of cell mechanics in a system with well-defined 3D geometry and mechanical properties.
Resumo:
Vitrectomy is a standard ophthalmic procedure to remove the vitreous body from the eye. The biomechanics of the vitreous affects its duration (by changing the removal rate) and the mechanical forces transmitted via the vitreous on the surrounding tissues during the procedure. Biomechanical characterization of the vitreous is essential for optimizing the design and control of instruments that operate within the vitreous for improved precision, safety, and efficacy. The measurements are carried out using a magnetic microprobe inserted into the vitreous, a method known as magnetic microrheology. The location of the probe is tracked by a microscope/camera while magnetic forces are exerted wirelessly by applied magnetic fields. In this work, in vitro artificial vitreous, ex vivo human vitreous and ex vivo porcine vitreous were characterized. In addition, in vivo rabbit measurements were performed using a suturelessly injected probe. Measurements indicate that viscoelasticity parameters of the ex vivo human vitreous are an order of magnitude different from those of the ex vivo porcine vitreous. The in vivo intra-operative measurements show typical viscoelastic behavior of the vitreous with a lower compliance than the ex vivo measurements. The results of the magnetic microrheology measurements were validated with those obtained by a standard atomic force microscopy (AFM) method and in vitro artificial vitreous. This method allows minimally-invasive characterization of localized mechanical properties of the vitreous in vitro, ex vivo, and in vivo. A better understanding of the characteristics of the vitreous can lead to improvements in treatments concerning vitreal manipulation such as vitrectomy.
Resumo:
Neste trabalho são apresentados processos de microfabricação de estruturas contendo microcanais e sistemas de manipulação hidrodinâmica e eletroosmótica de fluídos. Foram desenvolvidos processos de microfabricação utilizando toner sobre poliéster, toner sobre vidro, toner como resiste, além de métodos alternativos de perfuração de lâminas e selagem de microestruturas em vidro, desenvolvimento de microestruturas para eletroforese capilar e espectrometria de massas com ionização por eletronebulização. A caracterização dos materiais e processos permitiu uma ampla visão das potencialidades e alternativas dos processos de microfabricação, tendo sido demonstrado que os dispositivos produzidos em toner-poliéster são quimicamente resistentes às substâncias tipicamente utilizadas em eletroforese capilar. Neste trabalho, um detector condutométrico sem contato foi implementado em microestruturas de toner-poliéster e a separação eletroforética de alguns metais alcalinos é demonstrada. A microestrutura foi projetada no formato padrão em cruz, tendo o canal de separação 22 mm de comprimento, 12 µm de profundidade e largura típica. A cela condutométrica foi construída sobre o canal de separação utilizando-se fita adesiva de cobre (1 mm de largura) como eletrodos. O sinal aplicado na cela foi de 530 kHz e 10 Vpp . A separação de K+, Na+ e Li+ na concentração de 100 µmol L-1 foi efetuada em torno de 0,8 min, utilizando-se 1 kV como potencial de separação. Foram desenvolvidos microchips para análise por espectrometria de massas com introdução de amostra por eletronebulização, sendo determinado cluster do íon cloreto em concentração de 1 mmol L+. Também solução com 1 mmol/L de glucosamina em água/metanol 1: 1 (v/v), sob corrente de 100 nA gerou sinal estável e livre de descarga corona. Utilizando detecção amperométrica, obteve-se eletroferogramas mostrando a separação de iodeto (10 mmol L-1) e ascorbato (40 mmol L-1) em potencial de separação de 4,0 kV (800 V cm-1 potencial de detecção de 0,9 V (vs. Ag/AgCI), injeção com 1,0 kV/1°s, tampão borato de sódio 10 mmol L+ com CTAH 0,2 mmol L-1, pH 9,2. Obteve-se eficiência de 1,6.104 pratos/m e foi possível obter limites de detecção de 500 nmol L-1 (135 amol) e 1,8 µmol L-1 (486 amol) para iodeto e ascorbato, respectivamente. O processo de fabricação utilizando toner como material estrutural para microchips em vidro foi bem estabelecido, assim como os modos de detecção fotométrico e condutométrico foram demonstrados. Foram obtidos eletroferogramas par detecção condutométrica sem contato de solução 200 µmol L-1 de K+, Na+ e U+, em tampão histidina/ácido lático 30 mmol L-1 9:1 (v/v) água:metanol, injeção eletrocinética de 2,0 kV/5,0 s, potencial de separação de 1 kV, 530 kHz de frequência e tensão de 2,0 Vpp. Também foi implementado um sistema de detecção fotométrico para microchip operando em 660 nm, tendo sido utilizado para a detecção de azul de metileno 1,0 mmol L-1 em tampão de corrida de barato de sódio 20 mmol L-1 (pH 9,2), com o detector posicionado a 40 mm do ponto de injeção e com injeção eletrocinética a 2,0 kV por 12 s com picos bem resolvidos em menos de 1 min.