939 resultados para Microbially conditioned leaves


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to determine the feeding preference of Aegla platensis in streams and the importance of microorganisms in its detritivore diet, we carried out two experiments designed to evaluate the food preferences of A. platensis (1) among leaves with different levels of microbial colonization and (2) among insect larvae (Chironomidae, Simuliidae, Hydropsychidae) and microbially conditioned leaves. A. platensis preferred animal over plant food items; when only leaves were offered, this aeglid preferred the leaves with higher levels of microorganism conditioning.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The amphipod Gammarus pulex is an intermediate host to the acanthocephalan fish parasite Echinorhynchus truttae. Gammarus pulex has a wide trophic repertoire, feeding as a herbivore, detritivore and predator. In this study an examination was made of the effects of E. truttae parasitism on components of the G. pulex diet: stream-conditioned leaves, dead chironomids and live juvenile isopods Asellus aquaticus. Over 21 days, parasitism had no effect on daily feeding rates or wet weights of G. pulex fed on leaves or chironomids. Parasitism had a significant effect on the number of A. aquaticus killed by G. pulex, with parasitized individuals killing significantly fewer than their unparasitized counterparts. In addition, unparasitized amphipods killed all size classes of A. aquaticus indiscriminately, whereas parasitized animals tended to kill the smaller size classes. The impacts of the parasitism of G. pulex throughout the wider freshwater community are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The kinetics of naphthalene-2-sulfonic acid (2-NSA) adsorption by granular activated carbon (GAC) were measured and the relationships between adsorption, desorption, bioavailability and biodegradation assessed. The conventional Langmuir model fitted the experimental sorption isotherm data and introduced 2-NSA degrading bacteria, established on the surface of the GAC, did not interfere with adsorption. The potential value of GAC as a microbial support in the aerobic degradation of 2-NSA by Arthrobacter globiformis and Comamonas testosteroni was investigated. Using both virgin and microbially colonised GAC, adsorption removed 2-NSA from the liquid phase up to its saturation capacity of 140 mg/g GAC within 48 h. However, between 83.2% and 93.3% of the adsorbed 2-NSA was bioavailable to both bacterial species as a source of carbon for growth. In comparison to the non-inoculated GAC, the combination of rapid adsorption and biodegradation increased the amount (by 70–93%) of 2-NSA removal from the influent phase as well as the bed-life of the GAC (from 40 to >120 d). A microbially conditioned GAC fixed-bed reactor containing 15 g GAC removed 100% 2-NSA (100 mg/l) from tannery wastewater at an empty bed contact time of 22 min for a minimum of 120 d without the need for GAC reconditioning or replacement. This suggests that small volume GAC bioreactors could be used for tannery wastewater recycling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the accelerated trend of global warming, the thermal behavior of existing buildings, which were typically designed based on current weather data, may not be able to cope with the future climate. This paper quantifies, through computer simulations, the increased cooling loads imposed by potential global warming and probable indoor temperature increases due to possible undersized air-conditioning system. It is found from the sample office building examined that the existing buildings would generally be able to adapt to the increasing warmth of 2030 year Low and High scenarios projections and 2070 year Low scenario projection. However, for the 2070 year High scenario, the study indicates that the existing office buildings, in all capital cities except for Hobart, will suffer from overheating problems. When the annual average temperature increase exceeds 2°C, the risk of current office buildings subjected to overheating will be significantly increased. For existing buildings which are designed with current climate condition, it is shown that there is a nearly linear correlation between the increase of average external air temperature and the increase of building cooling load. For the new buildings, in which the possible global warming has been taken into account in the design, a 28-59% increase of cooling capacity under 2070 High scenario would be required to improve the building thermal comfort level to an acceptable standard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims to take advantage of recent developments in joint factor analysis (JFA) in the context of a phonetically conditioned GMM speaker verification system. Previous work has shown performance advantages through phonetic conditioning, but this has not been shown to date with the JFA framework. Our focus is particularly on strategies for combining the phone-conditioned systems. We show that the classic fusion of the scores is suboptimal when using multiple GMM systems. We investigate several combination strategies in the model space, and demonstrate improvement over score-level combination as well as over a non-phonetic baseline system. This work was conducted during the 2008 CLSP Workshop at Johns Hopkins University.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As climate change will entail new conditions for the built environment, the thermal behaviour of air-conditioned office buildings may also change. Using building computer simulations, the impact of warmer weather is evaluated on the design and performance of air-conditioned office buildings in Australia, including the increased cooling loads and probable indoor temperature increases due to a possibly undersized air-conditioning system, as well as the possible change in energy use. It is found that existing office buildings would generally be able to adapt to the increasing warmth of year 2030 Low and High scenarios projections and the year 2070 Low scenario projection. However, for the 2070 High scenario, the study indicates that the existing office buildings in all capital cities of Australia would suffer from overheating problems. For existing buildings designed for current climate conditions, it is shown that there is a nearly linear correlation between the increase of average external air temperature and the increase of building cooling load. For the new buildings designed for warmer scenarios, a 28-59% increase of cooling capacity under the 2070 High scenario would be required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Media and Communications in Australia, edited by Stuart Cunningham and Graeme Turner (3rd edition). Sydney: Allen and Unwin, 2010, 362 pp. ISBN 978-1 74237-064-4; reviewed by Lee Duffield, Queensland University of Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract During a survey of faba bean viruses in West Asia and North Africa a virus was identified as broad bean stain virus (BBSV) based on host reactions, electron microscopy, physical properties and serology. An antiserum to a Syrian isolate was prepared. With this antiserum both the direct double antibody sandwich ELISA (DAS-ELISA) and dot-ELISA were very sensitive in detecting BBSV in leaf extracts, ground whole seeds and germi nated embryos. Sens it i vity was not reduced when the two-day procedure was replaced by a one-day procedure. us i ng ELISA the vi rus was detected in 73 out of 589 faba bean samples with virus-like symptoms collected from Egypt (4 out of 70 samples tested), Lebanon (6/44) , Morocco (017), Sudan (19/254), Syria (36/145) and Tunisia (8/69). This is the first report of BBSV infection of faba bean in Lebanon, Sudan, Syria and Tunisia. speci es i ndi genous to Syri a were Fourteen wild legume susceptible to BBSV infection, with only two producing obvious symptoms. The virus was found to be seed transmitted ~n Vicia palaestina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major strategic goal in making ethanol from lignocellulosic biomass a cost-competitive liquid transport fuel is to reduce the cost of production of cellulolytic enzymes that hydrolyse lignocellulosic substrates to fermentable sugars. Current production systems for these enzymes, namely microbes, are not economic. One way to substantially reduce production costs is to express cellulolytic enzymes in plants at levels that are high enough to hydrolyse lignocellulosic biomass. Sugar cane fibre (bagasse) is the most promising lignocellulosic feedstock for conversion to ethanol in the tropics and subtropics. Cellulolytic enzyme production in sugar cane will have a substantial impact on the economics of lignocellulosic ethanol production from bagasse. We therefore generated transgenic sugar cane accumulating three cellulolytic enzymes, fungal cellobiohydrolase I (CBH I), CBH II and bacterial endoglucanase (EG), in leaves using the maize PepC promoter as an alternative to maize Ubi1 for controlling transgene expression. Different subcellular targeting signals were shown to have a substantial impact on the accumulation of these enzymes; the CBHs and EG accumulated to higher levels when fused to a vacuolar-sorting determinant than to an endoplasmic reticulum-retention signal, while EG was produced in the largest amounts when fused to a chloroplast-targeting signal. These results are the first demonstration of the expression and accumulation of recombinant CBH I, CBH II and EG in sugar cane and represent a significant first step towards the optimization of cellulolytic enzyme expression in sugar cane for the economic production of lignocellulosic ethanol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Windows are one of the most significant elements in the design of buildings. Whether there are small punched openings in the facade or a completely glazed curtain wall, windows are usually a dominant feature of the building's exterior appearance. From the energy use perspective, windows may also be regarded as thermal holes for a building. Therefore, window design and selection must take both aesthetics and serviceability into consideration. In this paper, using building computer simulation techniques, the effects of glass types on the thermal and energy performance of a sample air-conditioned office building in Australia are studied. It is found that a glass type with lower shading coefficient will have a lower building cooling load and total energy use. Through the comparison of results between current and future weather scenarios, it is identified that the pattern found from the current weather scenario would also exist in the future weather scenario, although the scale of change would become smaller. The possible implication of glazing selection in face of global warming is also examined. It is found that compared with its influence on building thermal performance, its influence on the building energy use is relatively small or insignificant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous research has shown resistance to extinction of fear conditioned to racial out-group faces, suggesting that these stimuli may be subject to prepared fear learning. The current study replicated and extended previous research by using a different racial out-group, and testing the prediction that prepared fear learning is unaffected by verbal instructions. Four groups of Caucasian participants were trained with male in-group (Caucasian) or out-group (Chinese) faces as conditional stimuli; one paired with an electro-tactile shock (CS+) and one presented alone (CS). Before extinction, half the participants were instructed that no more shocks would be presented. Fear conditioning, indexed by larger electrodermal responses to, and blink startle modulation during the CS+, occurred during acquisition in all groups. Resistance to extinction of fear learning was found only in the racial out-group, no instruction condition. Fear conditioned to a racial out-group face was reduced following verbal instructions, contrary to predictions for the nature of prepared fear learning.