285 resultados para Mentual foramen
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
CHAPTER II - The Chrysocyon brachyurus is the biggest South American canid which has a high frequency of dental injuries, both in wild and captivity. Thus, veterinary procedures are necessary to preserve the feeding capacity of hundreds of captive specimens worldwide. The aim of this study was to study the mandibular morphometry of maned wolf with emphasis on the establishment of anatomic references to the anesthetic blockage of the inferior alveolar and mental nerves. Therefore, 15 measurements in 22 hemimandibles of C. brachyurus adults were taken. For extra-oral technique of blockage of the inferior alveolar nerve at the level of the mandibular foramen, it is stated that the needle should be advanced, close to the medial surface of the mandibular ramus, by 11.4 mm perpendiculary from the palpable concavity. Alternatively, the needle can be introduced for 30.4 mm from the angular process at 20-25 degrees angle with the ventral margin. For blocking only the mentual nerve, it is recommended the introduction of needle for 10 mm, close to the lateral aspect of the mandibular body, at the level of the lower first premolar. The mandibular foramen showed similars position, size and symmetry in the maned wolfs specimens examined. The comparison of the data with those available for other carnivores reflects the necessity for determining these anatomical references specifically for each species.
Resumo:
The occipital dysplasia has been characterized by a dorsal enlargement of the foramen magnum which can vary in size and shape. Clinical signs may be present or not in animals with occipital dysplasia. The purpose of this study was to radiographically analyze the morphology and morphometry of the foramen magnum of thirty healthy dogs. This study chose to use fifteen Yorkshire terrier dogs and fifteen Toy Poodle dogs in order to characterize the radiographic aspects of the foramen magnum and contribute to the diagnosis and critical analysis of the occipital dysplasia importance. According to the foramen magnum morphology and tracings, it was possible to classify the radiographic aspects into different shapes varing from oval and quadrangular. Out of 26 (86.7%) animals had a dorsal enlargement and 4 (13.3%) showed normal foramen magnum. Animals without any clinical signs that are radiographically classified as dysplastic dogs may simply represent an anatomic variation of the foramen magnum.
Resumo:
The objective of the study is to describe our experience in the surgical management of foramen magnum meningiomas with regard to the clinical-radiological findings, the surgical approach and the outcomes after mid-term follow up. Over a 5-year period, 15 patients presenting with meningiomas of the foramen magnum underwent surgical treatment. The medical records were reviewed in order to analyze the clinical-radiological aspects, as well as the surgical approach and the outcomes. Based on the preoperative magnetic resonance imaging exams, the tumors were classified as anterior or anterolateral in the axial slices and clivospinal or spinoclival in the sagittal slices. The lateral approach was used in all cases. However, the extent of bone removal and the management of the vertebral artery were tailored to each patient. Fourteen patients were females, and one was male, ranging in age from 42 to 74 years (mean 55,9 years). The occipital condyle was partially removed in eight patients, and in seven patients, removal was not necessary. Total removal of the tumor was achieved in 12 patients, subtotal in two, and partial resection in one patient. Postoperative complications occurred in two patients. Follow-up ranged from 6 to 56 months (mean 23.6 months).There was no surgical mortality in this series. The extent of the surgical approach to foramen magnum meningiomas must be based on the main point of dural attachment and tailored individually case-by-case. The differentiation between the clivospinal and spinoclival types, as well as anterior and anterolateral types, is crucial for the neurosurgical planning of foramen magnum meningiomas.
Resumo:
Objective: Ligation of the sphenopalatine artery is used to treat severe nasal haemorrhage. The objective of the study was to investigate the numerical variation of the sphenopalatine foramen (SPF), its relation to the ethmoid bone crista of the palatine bone in the lateral nasal wall, its distance from the anterior nasal spine and the angle between this distance and the anterior nasal floor. Material and Methods: Fifty-four hemiskulls were submitted to anatomical study and measurements using the Image Tool 3.0 software. Results: The SPF was single in 87% of the specimens, and more than one orifice was present in 13%. It was possible to establish a relation with the ethmoid crista, which is a surgical reference for the SIT location. The mean values of the measurements were significantly higher in the hemifaces than in the hemiskulls ranging from 54 to 63mm, and angulation ranged from 20 to 32 degrees. Conclusions: In most specimens studied, the SPF was single and located in the superior nasal meatus. The distances measured suggest that these values can be used as distance references for the use of the endoscope for ligation or endonasal cauterization of the branches of the sphenopalatine artery, preventing possible errors and complications.
Resumo:
The foramen of Vesalius (FV) is located in the greater wing of the sphenoid bone between the foramen ovale (FO) and the foramen rotundum in an intracranial view. The FO allows the passage of the mandibular branch of trigeminal nerve, which is the target of the trigeminal radiofrequency rhizotomy. We analyzed its location, morphology, morphometry and interrelation among other foramina. 400 macerated adult human skulls were examined. A digital microscope (Dino-Lite plus(A (R))) was used to capture images from the FV. A digital caliper was used to perform the measurements of the distance between the FV and other foramina (FO, foramen spinosum and the carotid canal) in an extracranial view of the skull base. In the 400 analyzed skulls, the FV was identified in 135 skulls (33.75%) and absent on both sides in 265 skulls (66.25%). The FV was observed present bilaterally in 15.5% of the skulls. The incidence of unilateral foramen was 18.25% of the skulls of which 7.75% on right side and 10.5% on left side. The diameter of the FV was measured and we found an average value of 0.65 mm, on right side 0.63 mm and on the left side 0.67 mm. We verified that positive correlations were statistically significant among the three analyzed distances. This study intends to offer specific anatomical data with morphological patterns (macroscopic and mesoscopic) to increase the understanding of the FV features as frequency, incidence and important distances among adjacent foramina.
Resumo:
Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)
Resumo:
The mental foramen (MF) is an important anatomic landmark of the mandible, through which the mental nerve and blood vessels emerge. The importance of MF in dental practice is especially related to dental implants placement and other surgical procedures in the region. It is fundamental to be careful in order to avoid nerve and vessels injury during procedures. Anatomic variations of the MF can be found, such as occurrence of multiple foramina and unusual location. In very rare occasions, the absence of MF can be detected. The observation of this variation is not always possible using only conventional radiographs. The modern imaging resource cone beam computed tomography (CBCT) allows an accurate three-dimensional assessment of MF, as well as the identification of its variations. The aim of this article is to report MF absence and hypoplasia detected in CBCT images of a 27-year-old daughter and her 63-year-old mother, both from Brazil. Despite the MF anatomic variations, they presented no sensorial disturbance in the regions supplied by the mental nerve.
The calibre of the Foramen of Panizza in Crocodylus porosus is variable and under adrenergic control
Resumo:
The foramen of Panizza is located within the outflow tract of the crocodilian heart, between the left and right aortas. It has been suggested that the foremen of Panizza has a variable calibre, which could explain the profound changes in the distribution of flows and pressure profiles recorded in the right and left aortas. We investigated this possibility using a modified in-situ perfused heart preparation in combination with isolated strip preparations from the outflow tract. In the perfused heart preparation, bolus injections of adrenaline increased the resistance in the foramen of Panizza, indicating a decrease in its diameter. Isolated strip preparations from the outflow tract showed a concentration-dependent increase in tension in response to adrenaline, while vasoactive intestinal polypeptide caused a relaxation in adrenaline pre-contracted strip preparations. We propose that an increase in the diameter of the foremen of Panizza may be important during pulmonary to systemic shunts to allow blood to flow from the left to right aorta (reverse foramen flow) in order to supply the carotid and coronary arteries. During non-shunting conditions, a constricted foramen may prevent excess flow from the right to left aorta during diastole.
Resumo:
Os autores apresentam o caso clínico de uma doente de 35 anos, sexo feminino, que recorreu ao hospital da área da residência por parésia do membro superior direito, tendo sido diagnosticado AVC isquémico por Ressonância Magnética Nuclear Cranio-Encefálica (RMN-CE). A investigação da fonte embólica levou ao diagnóstico, por ecocardiograma transesofágico, de foramen oval patente (FOP), com shunt direito-esquerdo espontâneo. Em Maio de 2009 foi efectuado encerramento percutâneo do FOP com dispositivo bioreabsorvível “BioSTAR®”, sob controlo ecocardiográfico. Efectuou ecocardiograma transtorácico após o primeiro, terceiro e sexto mês pós-procedimento e ecocardiograma transesofágico aos nove meses, mostrando sempre adequada colocação do dispositivo, sem presença de shunt residual, sem qualquer intercorrência clínica durante este período. Os autores discutem a importância do desenvolvimento de dispositivos bioabsorvíveis para encerramento de FOP, e as suas vantagens em comparação com os dispositivos sintéticos previamente utilizados.
Resumo:
Apresenta-se o caso clínico de um recém- -nascido (RN) do sexo masculino, com diagnóstico pré-natal de síndrome do coração esquerdo hipoplásico (SCEH), referenciado às 37 semanas de gestação. No ecocardiograma fetal apresentava SCEH clássico com atrésia da aorta, válvula mitral permeável e septo interauricular espessado, mas com foramen ovale (FO) aparentemente permeável. Parto eutócico de termo, PN = 2540g, necessidade de intubação endotraqueal com ventilação assistida e prostaglandina E1 intravenosa. Imediatamente após o parto verificou-se agravamento clínico com deterioração dos valores gasimétricos. O ecocardiograma confirmou o diagnóstico, levantando a suspeita de encerramento do FO, que se confirmou no exame hemodinâmico, feito de seguida. Tentativa de atrioseptostomia de Rashkind, sem sucesso. O RN faleceu, tendo a autópsia revelado SCEH com FO encerrado, seio coronário aumentado e extensas linfangiectasias pulmonares. O aumento do seio coronário levou, neste caso, ao diagnóstico pré-natal errado de FO permeável com shunt esquerdo-direito.
Resumo:
Percutaneous closure of patent foramen ovale (PFO) has been proposed as the treatment of choice for young high-risk patients who suffered cryptogenic stroke and/or peripheral paradoxical embolism. We sought to compare prospectively two different devices used for percutaneous PFO closure.Prospective data were collected on 40 high risk patients (females: 38%, mean age : 44 +/- 11 years, interatrial septal aneurysm >10 mm: 68%) who underwent percutaneous PFO closure after cryptogenic stroke (n = 38) or peripheral paradoxical embolism (n = 2). Chronologically, 20 patients were first treated by a PFO-Star (Cardia, Burnsville, MI) device. Then, 20 other patients received a Starflex occluder (NMT, Boston, MA). The primary endpoint was complete PFO closure at 6 months as assessed by transthoracic contrast echocardiography. Secondary endpoints were major peri- or post procedural complications and clinical recurrence at 1 year follow-up.Baseline clinical and anatomical characteristics were comparable for both groups. Complete PFO closure was observed in 50% (PFO-Star) and 90% (Starflex) of patients (p=0.001) respectively. Major peri-procedural complications occurred in the PFO-star group only: right-sided device thrombus (1 patient) and aorto-right atrial fistula (1 patient). At 1 year follow-up, no clinical recurrence occurred.In conclusion, despite the absence of clinical recurrence in this high-risk population with presumed paradoxical embolism, complete PFO closure at 6 months follow-up was significantly related to the type of closure device used