487 resultados para Maxilares - Fraturas
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
137 p.
Resumo:
Tesis (Maestría en Ciencias Odontológicas con Especialidad en Ortodoncia) U.A.N.L.
Resumo:
Tesis (Maestría en Ciencias Odontológicas con Especialidad en Ortodoncia) U.A.N.L.
Resumo:
Tesis (Maestría en Ciencias Odontológicas con Especialidad en Ortodoncia) U.A.N.L.
Resumo:
Tesis (Doctorado en Ciencias con Especialidad en Morfología) UANL
Resumo:
Increase hydrocarbons production is the main goal of the oilwell industry worldwide. Hydraulic fracturing is often applied to achieve this goal due to a combination of attractive aspects including easiness and low operational costs associated with fast and highly economical response. Conventional fracturing usually involves high-flowing high-pressure pumping of a viscous fluid responsible for opening the fracture in the hydrocarbon producing rock. The thickness of the fracture should be enough to assure the penetration of the particles of a solid proppant into the rock. The proppant is driven into the target formation by a carrier fluid. After pumping, all fluids are filtered through the faces of the fracture and penetrate the rock. The proppant remains in the fracture holding it open and assuring high hydraulic conductivity. The present study proposes a different approach for hydraulic fracturing. Fractures with infinity conductivity are formed and used to further improve the production of highly permeable formations as well as to produce long fractures in naturally fractured formations. Naturally open fractures with infinite conductivity are usually encountered. They can be observed in rock outcrops and core plugs, or noticed by the total loss of circulation during drilling (even with low density fluids), image profiles, pumping tests (Mini-Frac and Mini Fall Off), and injection tests below fracturing pressure, whose flow is higher than expected for radial Darcian ones. Naturally occurring fractures are kept open by randomly shaped and placed supporting points, able to hold the faces of the fracture separate even under typical closing pressures. The approach presented herein generates infinite conductivity canal held open by artificially created parallel supporting areas positioned both horizontally and vertically. The size of these areas is designed to hold the permeable zones open supported by the impermeable areas. The England & Green equation was used to theoretically prove that the fracture can be held open by such artificially created set of horizontal parallel supporting areas. To assess the benefits of fractures characterized by infinite conductivity, an overall comparison with finite conductivity fractures was carried out using a series of parameters including fracture pressure loss and dimensionless conductivity as a function of flow production, FOI folds of increase, flow production and cumulative production as a function of time, and finally plots of net present value and productivity index
Resumo:
Os efeitos da estimulação ultra-sônica sobre a consolidação óssea têm sido demonstrados por trabalhos experimentais e clínicos. Este estudo teve por objetivo investigar a aplicação clínica do ultra-som pulsado de baixa intensidade como tratamento adjuvante de fraturas diafisárias em cães. Foram utilizados 16 cães de raças variadas, com faixa etária entre sete meses e seis anos, peso corpóreo entre 2,5 e 43kg, portadores de fraturas diafisárias fechadas recentes localizadas no rádio e ulna, fêmur ou tíbia e fíbula, estabilizadas por procedimentos de osteossíntese (fixação esquelética externa, pinos intramedulares ou a associação desses métodos). Os cães foram divididos em dois grupos: fraturas estabilizadas tratadas por ultra-som de baixa intensidade (grupo tratado, n=8); fraturas estabilizadas, não tratadas por estimulação ultra-sônica, (grupo controle, n=8). Os animais foram avaliados por exames clínicos e radiográficos nos períodos pré-operatório, pós-operatório imediato e a cada 30 dias posteriores aos procedimentos cirúrgicos. Realizou-se tratamento com ultra-som pulsado (sinal senoidal com freqüência de 1,5MHz, largura de pulso de 200µs e freqüência de repetição de 1kHz) de baixa intensidade (30mW cm-2), aplicado de modo estacionário no foco de fratura. A terapia ultra-sônica foi realizada 20 minutos por dia, durante 21 dias consecutivos, a partir do período compreendido entre o 1° e o 9° dia pós-operatório. O teste t de Student, empregado na análise estatística, mostrou diferença significante (P<0,001 e alfa=0,05) entre as médias dos parâmetros de tempo para consolidação óssea observadas nos animais dos grupos tratado (média de 67,5 dias) e controle (média de 106 dias). Este protocolo de estimulação ultra-sônica promoveu sinais clínicos e radiográficos acelerados da consolidação óssea nas fraturas tratadas. Os resultados deste estudo sugerem que o ultra-som pulsado de baixa intensidade pode ser indicado como terapia adjuvante de fraturas diafisárias recentes em cães.
Resumo:
Following the study of Andrade et al. (2009) on regular square lattices, here we investigate the problem of optimal path cracks (OPC) in Complex Networks. In this problem we associate to each site a determined energy. The optimum path is defined as the one among all possible paths that crosses the system which has the minimum cost, namely the sum of the energies along the path. Once the optimum path is determined, at each step, one blocks its site with highest energy, and then a new optimal path is calculated. This procedure is repeated until there is a set of blocked sites forming a macroscopic fracture which connects the opposite sides of the system. The method is applied to a lattice of size L and the density of removed sites is computed. As observed in the work by Andrade et al. (2009), the fractured system studied here also presents different behaviors depending on the level of disorder, namely weak, moderated and strong disorder intensities. In the regime of weak and moderated disorder, while the density of removed sites in the system does not depend of the size L in the case of regular lattices, in the regime of high disorder the density becomes substantially dependent on L. We did the same type of study for Complex Networks. In this case, each new site is connected with m previous ones. As in the previous work, we observe that the density of removed sites presents a similar behavior. Moreover, a new result is obtained, i.e., we analyze the dependency of the disorder with the attachment parameter m
Resumo:
The aim of this study was to comparatively evaluate the mechanical strength of squared and rectangular 2.0 mm system miniplates comparing them to the standard configuration with 2 straight miniplates in stabilizing fractures in the anterior mandible. Ninety synthetic polyurethane mandible replicas were used in mechanical test. The samples were divided into six groups of three different methods for fixation. Groups 1, 2 and 3 showed complete fractures in symphysis, characterized by a linear separation between the medial incisor, and groups 4, 5 and 6 showed complete fractures in parasymphysis with oblique design. Groups 1 and 4 were represented by the standard technique with two straight miniplates parallel to each other. Groups 2 and 5 were stabilized by squared miniplates and groups 3 and 6 were fixed by rectangular design. Each group was subjected to a mechanical test at a displacement speed of 10 mm/min on a universal testing machine, receiving linear vertical load on the region of the left first molar. The values of the maximum load and when displacements reached 5 mm were obtained and statistically analyzed by calculating the confidence interval of 95%. Fixation systems using squared (G2) and rectangular (G3) miniplates obtained similar results. No statistically significant differences with respect to the maximum load and the load at 5 mm displacement were found when compared to standard method in symphyseal fractures (G1). In parasymphysis the fixation method using squared miniplates (G5) obtained results without significant differences regarding the maximum load and the load at 5 mm when compared to the standard configuration (G4). The fixation method using rectangular miniplates (G6) showed inferior results which were statistically significant when compared to the standard configuration (G4) for parasymphysis fractures. The mechanical behavior of the fixation methods was similar, except when rectangular miniplates were used. The fixation methods showed better results with statistical significance in symphyseal fractures
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Realizou-se estudo retrospectivo (1987-2002) dos aspectos clínicos das fraturas vertebrais em eqüinos, bovinos, ovinos, caprinos e suínos atendidos no hospital veterinário da FMVZ-Unesp de Botucatu. Todos os casos tiveram confirmação radiográfica ou post-mortem. Segundo a espécie, a ordem de acometimento foi: bovina, eqüina, ovina, caprina e suína. As lesões ocorreram desde os 12 dias de idade até os 10 anos, com maior freqüência até os 12 meses. O segmento torácico foi o mais comprometido seguido dos segmentos lombar, cervical e sacral. As fraturas vertebrais devem fazer parte da lista de diagnósticos diferenciais de animais em decúbito, independente da espécie, sexo ou idade.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O trauma do seio frontal não é raro, correspondendo a 8% das fraturas faciais. Pode afetar a lâmina anterior e/ou posterior, com ou sem envolvimento do ducto nasofrontal. Tem alto potencial para complicações e seu manejo ainda é controvertido em algumas situações. OBJETIVO: Apresentar a epidemiologia, o diagnóstico e tratamento clínico e cirúrgico de 24 pacientes com fratura do seio frontal. MATERIAL E MÉTODOS: Estudo retrospectivo, não randomizado, de 24 pacientes com fratura de seio frontal operados no Hospital das Clínicas da Faculdade de Medicina de Botucatu, São Paulo, Brasil. RESULTADOS: Dos 24 pacientes, 16 tinham fraturas da lâmina externa e 8, da lâmina interna e externa. em 2 casos havia lesão do ducto nasofrontal. Vinte (83,4%) pacientes tiveram fraturas faciais associadas e em 13 (54,2%) foram observadas complicações intracranianas. A incisão em asa de borboleta, abaixo da sobrancelha, foi empregada na maioria dos casos cirúrgicos com bom resultado estético. Fixação dos fragmentos ósseos com diferentes materiais (fio de aço, mononylon, miniplacas de titânio) e, se necessário, reconstrução da tábua anterior com material aloplástico ou osso parietal. CONCLUSÃO: A causa principal das fraturas do seio frontal é acidente com veículos. O tratamento depende de sua complexidade, pois comumente há lesões cranioencefálicas associadas. As técnicas cirúrgicas utilizadas são as incisões, retalho bicoronal ou na sobrancelha, infra-orbital (em asa de borboleta), associadas à cirurgia endoscópica em casos de infecção fístula liquórica e complicações orbitárias.