846 resultados para Materiais para moldagem odontológica
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Currently the most widespread material used in dies is gypsum that together with its simple technique has very satisfactory mechanical, chemical and physical properties. However, its compactibility with the impression materials can compromise the die surface quality. In our work, we studies the hardness of the two gypsum types: Type III (die stone) and type IV (improved die stone), as well as the influence of the contact with three types of impression materials: polymerized silicone for condensation (Xantopren), polysulfide (Permlastic) and polymerized silicone by addition (Provil). As comparison parameter gypsum was used in contact with a glass surface…(Complete abstract click electronic access below)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The present study aims at evaluating dimensional alteration of stone casts made from impressions with a standard irreversible hydrocolloid and an antimicrobial one. For this, an alginate without disinfectant (Type II Jeltrate) and other containing chlorhexidine (Type II Avagel) were used, which rose by the same regime of treatment: without disinfection; immersion; and spraying. A 1% sodium hypochlorite solution was used for 10 minutes. To obtain the impressions, a perforated impression tray was made from a standard metal model. After molding, the molds were washed in running water for 30 seconds to simulate removal of saliva. Then, with the exception of the control group, these molds were subjected to disinfection treatment. After 10 minutes they were washed again. 60 samples poured with type V special gypsum (Durone) were obtained, that were measured 3 times in a stereomicroscope (SZX12, Olympus) to record the average of dimensional alterations. The disinfection treatment did not bring significant changes in the models obtained from both alginate tested (standard p = 0.7102; with chlorhexidine p = 0.5832). The results showed a statistically significant and additional advantage of the traditional alginate on alginate with chlorhexidine, with respect to dimensional alteration (p < 0.05).
Resumo:
The dental trade has offered dental impression and dental stone for orthodontic use ensuring accurate models. The compatibility between these materials is defined by the wetting of the model surfaces by the mixture water/stone poured over it and the influenced by the method of disinfection of model and disinfectant solution used. It was evaluated the influence of spray disinfection with sodium hypochlorite 1% on the wettability of two commercial alginate (Jeltrate ® - Dentsply and Orthoprint ® - Zhermack) at two commercial type III gypsum (Rio ® - ME and AOBussoli Orthogesso Orthogesso ®-SA). Twenty models were fabricated for each type of alginate, which were divided into two groups (water and sodium hypochlorite), receiving respectively water and sodium hypochlorite 1% spray. Each group of models was then further divided into two subgroups, and on their surface were poured 2 ml of type III gypsum (Gesso Rio® or Orthogesso®). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to ANOVA and founded statistical significance for solutions used. It was concluded that sodium hypochlorite spray improved wettability of alginates studied.
Resumo:
The cares at the manipulation of the alginate (condensation, disinfection of the impression and the time elapsed until the leak of the plaster) deserve special attention considering the great amount of distortions occurring every time the impression is not fill of plaster in a brief space of time and appropriate storage conditions. Besides its adaptation to the plaster suffers influence of the events happened after the impression is removed of the mouth. The purpose of this research was to evaluate the wetting capacity of three brands of alginate (Jeltrate™,Hydrogum™ e Orthoprint™) by the plaster type III (Rio™) under the influence of disinfection by sodium hypochlorite 1% sprays and the time of storage of 15 minutes,30 minutes, 1 hour, 6, 12 and 24 hours. There were made 60 impressions of each brand of alginate divided in two groups (water and sodium hypochlorite 1%) rearranged after the application of the sodium hypochlorite spray according to the storage time (15 or 30 minutes and 1,6,12, or 24 hours). On the surface of the impressions 2ml of plaster were flowed, proportioned and condensed in agreement with manufacturer‘s instructions. After the final setting expansion the casts were sectioned vertically and medially, regularized at the cut surface (emery paper 400) and setted for reading the contact angle at the microscope Carl Zeiss. The obtained results, submitted to statistical treatment (ANOVA) revealed significant differences when compared the employed solutions (water and sodium hypochlorite 1%) and the time of storage. The sodium hypochlorite 1% exhibited the smallest contact angles and the times of storage of 15 minutes and 6 hours the smallest and larger angles, respectively. It can be concluded that the alginate impressions exhibited larger adaptation to the plaster when disinfected by hypochlorite of sodium 1% and stocked by 15 minutes.
Resumo:
The anatomical and functional impressions philosophies are presented to the professionals who are active in the area, so that they can review concepts and thus obtain more precise molds, based on scientific knowledge. In parallel, impression techniques recommended by the Prosthodontics subject from Araçatuba Dental School – UNESP are also commented.
La relación entre la calidad de la enseñanza y la mala práctica odontológica: relato de caso clínico
Resumo:
Las actividades desarrolladas en el área de la salud son de gran importancia, pues tienen como finalidad preservar la vida de los individuos y para eso deben ser desempeñadas por personas habilitadas. El aumento del número de facultades de Odontología, la disminución en la calidad de la enseñanza y el mayor ingreso de alumnos con baja capacidad para ejercer la profesión son hechos que traen consecuencias desastrosas para la sociedad. Estos hechos también se reflejan en el desempeño moral, ético y técnico-científico del profesional. El objetivo de ese relato de caso clínico es enseñar que, aunque hay una considerable oferta de instituciones de enseñanza, existe un desconocimiento científico y de técnicas adecuadas por parte de los cirujanos dentistas graduados. La paciente MSL, 17 años, sexo femenino, compareció al consultorio odontológico usando un molde tipo Vernis, sujeto al arco inferior. Tras evaluación clínica, se observó la utilización de un material incorrecto para la toma de impresión, siendo imposible su retiro con el método convencional. La planificación para su retiro se hizo por medio de seccionamiento. De esta manera, la consecuencia de la falta de conocimiento en el uso de materiales para la impresión causó gran trastorno a la paciente. Se puede concluir que el índice de impericia está relacionado directamente con la formación profesional, evidenciando la importancia de la enseñanza odontológica de calidad para una práctica clínica responsable.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The activities developed in health area are of great importance, because they have the aim to preserve the life of the men, and therefore, must be performed by authorized persons. The increase of the number of dental schools, the decline at the education quality and a higher admission of students with low ability to exercise their profession, are facts that bring disastrous consequences for society. These facts are, also, reflected at the moral, ethical and technical-scientific performance of the professional. The purpose of this clinic case is to show that although there is a significant suplly of education institutions, there is a lack of scientific and adequate technical knowledgement from the graduated dentals surgeons. The patient MSL, 17 year old, female, went to a dental clinic presenting a tray type Vernis, attached to the lower arch. After clinical evaluation, it was showed that an incorrect material was used for the impression technique, being impossible to take out the tray by the conventional manner. The planning for the removal of the tray was through the divide of it. Thus, the consequence of the lack of knowledge in the use of impression materials had caused a great incovinience to the patient. It can be concluded that the rate of malpractice is directly related to the professional preparation, highlighting the importance of quality dental education for a responsible clinical practice.
Resumo:
Este trabalho avaliou comparativamente, em laboratório, a fidelidade dimensional de quatro materiais de moldagem usados nas moldagens finais em prótese total, um hidrocolóide irreversível (Hidrogum), um poliéter (Impregum) e dois silicones de adição (Honigum e Extrude), bem como a técnica de dupla moldagem, com ou sem alívio, usando o material Extrude de consistências média e leve. Para isto foi usado como corpo de prova um modelo metálico que simula um maxilar edêntulo, onde foram colocados quatro postes em forma do pirâmide, três truncadas, colocadas na crista do rebordo para medições horizontais, e uma inteira, que servia de referência para uma medição vertical. Com cada material ou técnica foram feitos dez moldes do modelo padrão, que foram vazados com gesso tipo IV. Os sessenta modelos obtidos, bem como o modelo-padrão, foram submetidos às medições das distâncias entre as referências situadas nas pirâmides, três medidas no sentido horizontal e uma no sentido vertical. Isto foi feito numa máquina para medição por coordenadas (tridimensionai), BRT-M507 fabricada pela Mitutoyo, com software Cosmos/Geopak-Win. Os resultados foram submetidos à analise de variância e testes complementares (Post Hoc Tests, de Duncan). A análise dos resultados mostra que quase todas as medidas no plano horizontal foram menores nas réplicas que no padrão, e que na medida vertical a discrepância entre os resultados foi maior, sendo umas medidas maiores e outras menores que no padrão. Estatisticamente, apenas numa das três distâncias avaliadas, Dist. 2, não houve diferença significativa entre os materiais. Concluiu-se que, com exceção do material Extrude em moldagem simples, os silicones e o poliéter tiveram desempenho semelhante, e que o hidrocolóide irreversível evidenciou os piores resultados. Outra conclusão foi que as duas técnicas de dupla moldagem usando materiais de consistências diferentes mostraram resultados semelhantes ao Honigum e Impregum, sendo mais precisas que estes na reprodução da altura, medida relacionada com a moldagem da zona de postdamming no paciente edêntulo.
Resumo:
There is a lack of clinical studies evaluating techniques of functional impression for partially edentulous arches. The aim of this double-blind non-randomized controlled clinical trial was to compare the efficacy of altered cast impression (ACI) and direct functional impression (DFI) techniques. The efficacy was evaluated regarding the number of occlusal units on denture teeth, mucosa integrity at 24-hour follow-up and denture base extension. The sample included 51 patients (female and male) with mean age of 58.96 years treated at Dental Department of UFRN. The patients, exhibiting edentulous maxilla and mandibular Kennedy class I, were divided into two groups (group ACI, n=29; group DFI, n=22). Clinical evaluation was based on the number of occlusal units on natural and/or artificial teeth, mucosa integrity at 24-hour follow-up, and denture base extension. Statistical analysis was conducted using the software SPSS 17.0® (SPSS Inc., Chicago, Illinois). Student T-test was used to reveal association between number of occlusal units and impression technique while chi-square test showed association between mucosa integrity and impression technique. Fischer s exact test was applied for association between denture base extension and impression technique at 95% level of significance. No significant difference was observed between the groups regarding number of occlusal units, mucosa integrity and denture base extension. The altered cast technique did not provide significant improvement in comparison to the direct technique when the number of occlusal units, mucosa integrity and denture base extension
Resumo:
Alginate or irreversible hydrocolloid is one the most accepted and frequently employed impression materials in dental practice. Substances like zinc, cadmium, lead silicate and fluorides, which are included in several alginate brands with the aim of improving their physical, chemical and mechanical properties, are a source of serious concern as regards their toxicity. Some brands of alginate have been reported to contain potentially toxic fluorides and metals such as cadmium, lead and zinc silicates, either singly or combined. Consequently, special care should be taken while preparing of these materials. It is necessary to monitor potentially toxic chemicals and metals in the alginates continually to avoid contamination of dental professionals and patients. In this review, alginates used in dentistry are analyzed for potential toxicity.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)