425 resultados para Magnet
Resumo:
Metal-organic materials constitute a new field in which to search for ferroelectricity and coupling between electricity and magnetism. We observe a magnetic field-induced change in the electric polarization, Delta P(H), that reaches 50 mu C/m(2) in single crystals of NiCl(2)-4SC(NH(2))(2) (DTN). DTN forms a tetragonal structure that breaks inversion symmetry with the electrically polar thiourea molecules [SC(NH(2))] all tilted in the same direction along the c axis. The field H induces canted antiferromagnetism of the Ni S = 1 spins between 2 and 12 T and our measurements show that the electric polarization increases monotonically in this range, saturating above 12 T. By modeling the microscopic origin of this magnetoelectric effect, we find that the leading contribution to Delta P comes from the change in the crystal electric field, with a smaller contribution from magnetic exchange striction. The finite value of Delta P induced by magnetostriction results from the polar nature of the thiourea molecules bonded to the Ni atoms, and it is amplified by the softness of these organic molecules.
Resumo:
Almost all clinical magnetic resonance imaging systems are based on circular cross-section magnets. Recent advances in elliptical cross-section RF probe and gradient coil hardware raise the question of the possibility of using elliptical cross-section magnet systems, This paper presents a methodology for calculating rapidly the magnetic fields generated by a multi-turn coil of elliptical cross-section and incorporates this in a stochastic optimization method for magnet design, An open magnet system of elliptical cross-section is designed that both reduces the claustrophobia for the patients and allows ready access by attending physicians, The magnet system is optimized for paediatric use, The coil geometry produced by the optimization method has several novel features.
Resumo:
Magnetic resonance microscopy (MRM) depends on the use of high field, superconducting magnet systems for its operation. The magnets that are conventionally used are those that were initially designed for chemical structural analysis work. A novel, compact magnet designed specifically for MRM is presented here, and while preserving high field, high homogeneity conditions, has a length less than one-third that of conventional systems. This enables much better access to samples, an important consideration in many MRM experiments. As the homogeneity of a magnet is strongly dependent on its length, novel geometries and optimization techniques are required to meet the requirements of MRM in a compact system. An important outcome of the stochastic optimization performed in this work, is that the use used of a thin superconducting solenoid surrounded by counterwound disk windings provides a mechanism for drastic length reductions over conventional magnet designs. (C) 1998 American Institute of Physics.
Resumo:
Imaging of the head and neck is the most commonly performed clinical magnetic resonance imaging (MRI) examination [R. G. Evans and J. R. G. Evans, AJR 157, 603 (1991)]. This is usually undertaken in a generalist MRI instrument containing superconducting magnet system capable of imaging all organs. These generalist instruments are large, typically having a bore of 0.9-1.0 m and a length of 1.7-2.5 m and therefore are expensive to site, somewhat claustrophobic to the patient, and offer little access by attending physicians. In this article, we present the design of a compact, superconducting MRI magnet for head and neck imaging that is less than 0.8 m in length and discuss in detail the design of an asymmetric gradient coil set, tailored to the magnet profile. In particular, the introduction of a radio-frequency FM modulation scheme in concert with a gradient sequence allows the epoch of the linear region of the gradient set to be much closer to the end of the gradient structure than was previously possible. Images from a prototype gradient set demonstrate the effectiveness of the designs. (C) 1999 American Institute of Physics. [S0034-6748(99)04910-2].
Resumo:
This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.
Resumo:
Recent research (Kuhl, 1991) has suggested that the internal structure of vowel categories is graded in terms of stimulus goodness. It has been proposed that a best instance stimulus reflects a central point or prototype, which effectively renders within-category members perceptually more similar. Discrimination experiments suggest a nonlinear relationship between acoustic and perceptual space near category centers (Iverson & Kuhl, 1995b). This phenomenon has been described as the perceptual magnet effect. The present study investigated the presence of the perceptual magnet effect in five Australian vowel categories. Australian English speakers identified, rated, and discriminated between a pool of 32 vowel stimuli that varied in F1 and F2 values. The results from Experiments 1 and 2 showed that subjects were able to judge the quality and identity of each stimulus and that a general grading of stimulus quality was reported. This was not symmetrical, and the subjects' responses varied considerably. In Experiment 3, closer control of the methodology in the discrimination task and of contextual factors influencing the test materials was exercised. Despite this, evidence of the warping of perceptual space in discrimination data was not found. In general, these results do not provide support for the existence of the perceptual magnet effect, and explanations for this finding are discussed.
Resumo:
In this work, a new method of optimization is successfully applied to the theoretical design of compact, actively shielded, clinical MRI magnets. The problem is formulated as a two-step process in which the desired current densities on multiple, cc-axial surface layers are first calculated by solving Fredholm equations of the first kind. Non-linear optimization methods with inequality constraints are then invoked to fit practical magnet coils to the desired current densities. The current density approach allows rapid prototyping of unusual magnet designs. The emphasis of this work is on the optimal design of short, actively-shielded MRI magnets for whole-body imaging. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric, and asymmetric MRI magnets. Magnet designs are presented for actively-shielded, symmetric magnets of coil length 1.0 m, which is considerably shorter than currently available designs of comparable dsv size. Novel, actively-shielded, asymmetric magnet designs are also presented in which the beginning of a 50-cm dsv is positioned just 11 cm from the end of the coil structure, allowing much improved access to the patient and reduced patient claustrophobia. Magn Reson Med 45:331540, 2001. (C) 2001 Wiley-Liss, Inc.
Resumo:
Magnetic resonance imaging (MRI) magnets have very stringent constraints on the homogeneity of the static magnetic field that they generate over desired imaging regions. The magnet system also preferably generates very little stray field external to its structure, so that ease of siting and safety are assured. This work concentrates on deriving, means of rapidly computing the effect of 'cold' and 'warm' ferromagnetic material in or around the superconducting magnet system, so as to facilitate the automated design of hybrid material MR magnets. A complete scheme for the direct calculation of the spherical harmonics of the magnetic field generated by a circular ring of ferromagnetic material is derived under the conditions of arbitrary external magnetizing fields. The magnetic field produced by the superconducting coils in the system is computed using previously developed methods. The final, hybrid algorithm is fast enough for use in large-scale optimization methods. The resultant fields from a practical example of a 4 T, clinical MRI magnet containing both superconducting coils and magnetic material are presented.
Resumo:
In this paper, two wind turbines equipped with a permanent magnet synchronous generator (PMSG) and respectively with a two-level or a multilevel converter are simulated in order to access the malfunction transient performance. Three different drive train mass models, respectively, one, two and three mass models, are considered in order to model the bending flexibility of the blades. Moreover, a fractional-order control strategy is studied comparatively to a classical integer-order control strategy. Computer simulations are carried out, and conclusions about the total harmonic distortion (THD) of the electric current injected into the electric grid are in favor of the fractional-order control strategy.
Resumo:
A transient analysis for two full-power converter wind turbines equipped with a permanent magnet synchronous generator is studied in this article, taking into consideration, as a new contribution to earlier studies, a pitch control malfunction. The two full-power converters considered are, respectively, a two-level and a multi-level converter. Moreover, a novel control strategy based on fractional-order controllers for wind turbines is studied. Simulation results are presented; conclusions are in favor of the novel control strategy, improving the quality of the energy injected into the electric grid.
Resumo:
Electric Vehicles (EVs) are increasingly used nowadays, and different powertrain solutions can be adopted. This paper describes the control system of an axial flux Permanent Magnet Synchronous Motor (PMSM) for EVs powertrain. It is described the implemented Field Oriented Control (FOC) algorithm and the Space Vector Modulation (SVM) technique. Also, the mathematical model of the PMSM is presented. Both, simulation and experimental, results with different types of mechanical load are presented. The experimental results were obtained using a laboratory test bench. The obtained results are discussed.
Resumo:
Rapport de synthèse : Le Magnet Tracking System (MTS) est une technique peu invasive d'investigation de la motilité de l'entier du tube digestif. Elle repose sur le suivi de la progression d'un aimant par des senseurs externes en temps réel et dans les 3 dimensions. Dans cette étude, le MTS a été utilisé pour étudier les caractéristiques de propulsion propres aux différents segments coliques ainsi que pour comparer le transit de l'aimant permanent du MTS à celui de marqueurs radioopaques habituellement utilisés. Dix hommes et 10 femmes ayant un transit gastro-intestinal régulier ont ingéré simultanément un aimant de MTS et une capsule contenant 10 marqueurs radio-opaques, à 20h00. Les enregistrements se sont ensuite déroulés sur 2 matinées successives de 5 heures. L'analyse des données brutes recueillies a permis de réaliser une projection spatio-temporelle de la trajectoire de l'aimant dans le tube digestif ainsi qu'une description précise de l'origine, de la direction, de l'amplitude et de la vitesse des mouvements coliques. Des radiographies d'abdomen ont permis de comparer les positions respectives des marqueurs radio-opaques et de l'aimant du MTS. Durant 90% du temps d'enregistrement, l'aimant était immobile ou présentait des mouvements alternatifs de faible amplitude. Le reste des enregistrements consiste en activité propulsive dont 20% représentent des déplacements rétrogrades et une description très précise de 34 mouvements de masses. L'analyse des déplacements démontre une distribution bimodales des vitesses voisine de 1.5 et 50 cm /min, ce tant en direction orale que caudale. Deux tiers des distances parcourues le sont à vitesse rapide. L'analyse segmentaire confirme une progression horaire absolue supérieure dans le côlon gauche que droit. L'analyse détaillée par segment colique, reposant sur la description des déplacements enregistrés correspond aux rôles reconnus des différents segments, notamment de aire de stockage et de conditionnement du côlon ascendant ou de transit du côlon descendant. La comparaison des 2 sexes démontre un nombre plus important de mouvements, particulièrement de mouvements de masse chez l'homme. Les radiographies montrent une bonne corrélation entre la position de l'aimant et celle des marqueurs radio-opaques. Le MTS permet ainsi une description précise des caractéristiques propulsives des différents segments coliques, notamment par l'analyse détaillée des progressions à vitesses lente et rapide et leurs directions. Des distinctions peuvent également être notées en fonction du sexe. Ces investigations offrent de nouvelles perspectives pour l'étude des troubles de la motilité digestive.
Resumo:
The efficiency of the Mosquito Magnet Liberty PlusTM (MMLP) trap was evaluated in comparison to human-landing catches (HLCs) to sample anopheline populations in Jabillal, state of Bolivar, southern Venezuela. The village comprised 37 houses and a population of 101; malaria in this village is primarily due to Plasmodium vivax and the Annual Parasite Index is 316.8 per 1,000 population. A longitudinal study was conducted between June 2008-January 2009 for three nights per month every two months between 17:30 pm-21:30 pm, a time when biting mosquitoes are most active. Anopheles darlingi and Anopheles nuneztovari were the most common species collected by both methods, whereas Anopheles marajoara was more abundant according to the HLC method. The MMLP trap was more efficient for collecting An. nuneztovari [63%, confidence interval (CI): 2.53] than for collecting An. darlingi (31%, CI: 1.57). There were significant correlations (p < 0.01) between the two methods for An. darlingi [Pearson correlation (R²) = 0.65] and An. nuneztovari (R² = 0.48). These preliminary results are encouraging for further investigations of the use of the MMLP trap for monitoring anopheline populations in remote malaria-endemic areas in the Amazon Basin.
Resumo:
Traps are widely employed for sampling and monitoring mosquito populations for surveillance, ecological and fauna studies. Considering the importance of assessing other technologies for sampling mosquitoes, we addressed the effectiveness of Mosquito Magnet® Independence (MMI) in comparison with those of the CDC trap with CO2 and Lurex3® (CDC-A) and the CDC light trap (CDC-LT). Field collections were performed in a rural area within the Atlantic Forest biome, southeastern state of São Paulo, Brazil. The MMI sampled 53.84% of the total number of mosquitoes, the CDC-A (26.43%) and CDC-LT (19.73%). Results of the Pearson chi-squared test (χ2) showed a positive association between CDC-LT and species of Culicini and Uranotaeniini tribes. Additionally, our results suggested a positive association between CDC-A and representatives of the Culicini and Aedini tribes, whereas the MMI was positively associated with the Mansoniini and Sabethini as well as with Anophelinae species. The MMI sampled a greater proportion (78.27%) of individuals of Anopheles than either the CDC-LT (0.82%) or the CDC-A traps (20.91%). Results of the present study showed that MMI performed better than CDC-LT or CDC-A in sampling mosquitoes in large numbers, medically important species and assessing diversity parameters in rural southeastern Atlantic Forest.