994 resultados para Loop-mediated isothermal amplificiation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Diagnosis of meningococcal disease relies on recognition of clinical signs and symptoms that are notoriously non-specific, variable, and often absent in the early stages of the disease. Loop-mediated isothermal amplification (LAMP) has previously been shown to be fast and effective for the molecular detection of meningococcal DNA in clinical specimens. We aimed to assess the diagnostic accuracy of meningococcal LAMP as a near-patient test in the emergency department.

Methods: For this observational cohort study of diagnostic accuracy, children aged 0-13 years presenting to the emergency department of the Royal Belfast Hospital for Sick Children (Belfast, UK) with suspected meningococcal disease were eligible for inclusion. Patients underwent a standard meningococcal pack of investigations testing for meningococcal disease. Respiratory (nasopharyngeal swab) and blood specimens were collected from patients and tested with near-patient meningococcal LAMP and the results were compared with those obtained by reference laboratory tests (culture and PCR of blood and cerebrospinal fluid).

Findings: Between Nov 1, 2009, and Jan 31, 2012, 161 eligible children presenting at the hospital underwent the meningococcal pack of investigations and were tested for meningococcal disease, of whom 148 consented and were enrolled in the study. Combined testing of respiratory and blood specimens with use of LAMP was accurate (sensitivity 89% [95% CI 72-96], specificity 100% [97-100], positive predictive value 100% [85-100]; negative predictive value 98% [93-99]) and diagnostically useful (positive likelihood ratio 213 [95% CI 13-infinity] and negative likelihood ratio 0·11 [0·04-0·32]). The median time required for near-patient testing from sample to result was 1 h 26 min (IQR 1 h 20 min-1 h 32 min).

Interpretation: Meningococcal LAMP is straightforward enough for use in any hospital with basic laboratory facilities, and near-patient testing with this method is both feasible and effective. By contrast with existing UK National Institute of Health and Care Excellence guidelines, we showed that molecular testing of non-invasive respiratory specimens from children is diagnostically accurate and clinically useful.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method of loop-mediated isothermal amplification (LAMP) was employed to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). The amplification could be finished in 60 min under isothermal condition at 64 degrees C by employing a set of four primers targeting the cap gene of PCV2. The LAMP assay showed higher sensitivity than the conventional PCR, with a detection limit of five copies per tube of purified PCV2 genomic DNA. No cross-reactivity was observed from the samples of other related viruses including porcine circovirus type 1 (PCV1), porcine parvovirus (PPV), porcine pseudorabies virus (PRV) and porcine reproductive and respiratory syndrome virus (PRRSV). The detection rate of PCV2 LAMP for 86 clinical samples was 96.5% and appeared greater than that of the PCR method. The LAMP assay reported can provide a rapid yet simple test of PCV2 suitable for laboratory diagnosis and pen-side detection due to ease of operation and the requirement of only a regular water bath or heat block for the reaction. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using the LAMP method, a highly specific and sensitive detection system for genetically modified soybean (Roundup Ready) was designed. In this detection system, a set of four primers was designed by targeting the exogenous 35S epsps gene. Target DNA was amplified and visualized on agarose gel within 45 min under isothermal conditions at 65 degrees C. Without gel electrophoresis, the LAMP amplicon was visualized directly in the reaction tube by the addition of SYBR Green I for naked-eye inspection. The detection sensitivity of LAMP was 10-fold higher than the nested PCR established in our laboratory. Moreover, the LAMP method was much quicker, taking only 70 min, as compared with 300 min for nested PCR to complete the analysis of the GM soybean. Compared with traditional PCR approaches, the LAMP procedure is faster and more sensitive, and there is no need for a special PCR machine or electrophoresis equipment. Hence, this method can be a very useful tool for GMO detection and is particularly convenient for fast screening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Loop-mediated isothermal amplification (LAMP) is an innovative technique that allows the rapid detection of target nucleic acid sequences under isothermal conditions without the need for complex instrumentation. The development, optimization, and clinical validation of a LAMP assay targeting the ctrA gene for the rapid detection of capsular Neisseria meningitidis were described. Highly specific detection of capsular N. meningitidis type strains and clinical isolates was demonstrated, with no cross-reactivity with other Neisseria spp. or with a comprehensive panel of other common human pathogens. The lower limit of detection was 6 ctrA gene copies detectable in 48 min, with positive reactions readily identifiable visually via a simple color change. Higher copy numbers could be detected in as little as 16 min. When applied to a total of 394 clinical specimens, the LAMP assay in comparison to a conventional TaqMan® based real-time polymerase chain reaction system demonstrated a sensitivity of 100% and a specificity of 98.9% with a ? coefficient of 0.942. The LAMP method represents a rapid, sensitive, and highly specific technique for the detection of N. meningitidis and has the potential to be used as a point-of-care molecular test and in resource-poor settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Loop-mediated isothermal amplification (LAMP) is an innovative technique that allows the rapid detection of target nucleic acid sequences under isothermal conditions without the need for complex instrumentation. The development, optimization, and clinical validation of a LAMP assay targeting the ctrA gene for the rapid detection of capsular Neisseria meningitidis were described. Highly specific detection of capsular N. meningitidis type strains and clinical isolates was demonstrated, with no cross-reactivity with other Neisseria spp. or with a comprehensive panel of other common human pathogens. The lower limit of detection was 6 ctrA gene copies detectable in 48 min, with positive reactions readily identifiable visually via a simple color change. Higher copy numbers could be detected in as little as 16 min. When applied to a total of 394 clinical specimens, the LAMP assay in comparison to a conventional TaqMan® based real-time polymerase chain reaction system demonstrated a sensitivity of 100% and a specificity of 98.9% with a ? coefficient of 0.942. The LAMP method represents a rapid, sensitive, and highly specific technique for the detection of N. meningitidis and has the potential to be used as a point-of-care molecular test and in resource-poor settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Improved methods for the detection of Histoplasma capsulatum are needed in regions with limited resources in which the organism is endemic, where delayed diagnosis of progressive disseminated histoplasmosis (PDH) results in high mortality rates. We have investigated the use of a loop-mediated isothermal amplification (LAMP) assay to facilitate rapid inexpensive molecular diagnosis of this disease. Primers for LAMP were designed to amplify the Hcp100 locus of H. capsulatum. The sensitivity and limit of detection were evaluated using DNA extracted from 91 clinical isolates of known geographic subspecies, while the assay specificity was determined using DNA extracted from 50 other fungi and Mycobacterium tuberculosis. Urine specimens (n = 6) collected from HIV-positive individuals with culture- and antigen-proven histoplasmosis were evaluated using the LAMP assay. Specimens from healthy persons (n = 10) without evidence of histoplasmosis were used as assay controls. The Hcp100 LAMP assay was 100% sensitive and specific when tested with DNA extracted from culture isolates. The median limit of detection was <= 6 genomes (range, 1 to 300 genomes) for all except one geographic subspecies. The LAMP assay detected Hcp100 in 67% of antigen-positive urine specimens (4/6 specimens), and results were negative for Hcp100 in all healthy control urine specimens. We have shown that the Hcp100 LAMP assay is a rapid affordable assay that can be used to expedite culture confirmation of H. capsulatum in regions in which PDH is endemic. Further, our results indicate proof of the concept that the assay can be used to detect Histoplasma DNA in urine. Further evaluation of this assay using body fluid samples from a larger patient population is warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop a multiplex loop-mediated isothermal amplification (LAMP) method capable of detecting Escherichia coli generally and verocytotoxigenic E. coli (VTEC) specifically in beef and bovine faeces. The LAMP assay developed was highly specific (100%) and able to distinguish between E. coli and VTEC based on the amplification of the phoA, and stx1 and/or stx2 genes, respectively. In the absence of an enrichment step, the limit of detection 50% (LOD50) of the LAMP assay was determined to be 2.83, 3.17 and 2.83-3.17 log CFU/g for E. coli with phoA, stx1 and stx2 genes, respectively, when artificially inoculated minced beef and bovine faeces were tested. The LAMP calibration curves generated with pure cultures, and spiked beef and faeces, suggested that the assay had good quantification capability. Validation of the assay, performed using retail beef and bovine faeces samples, demonstrated good correlation between counts obtained by the LAMP assay and by a conventional culture method, but suggested the possibility of false negative LAMP results for 12.5-14.7% of samples tested. The multiplex LAMP assay developed potentially represents a rapid alternative to culture for monitoring E.coli levels in beef or faeces and it would provide additional information on the presence of VTEC. However, some further optimisation is needed to improve detection sensitivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Contagious Bovine Pleuropneumonia (CBPP) is the most important chronic pulmonary disease of cattle on the African continent causing severe economic losses. The disease, caused by infection with Mycoplasma mycoides subsp. mycoides is transmitted by animal contact and develops slowly into a chronic form preventing an early clinical diagnosis. Because available vaccines confer a low protection rate and short-lived immunity, the rapid diagnosis of infected animals combined with traditional curbing measures is seen as the best way to control the disease. While traditional labour-intensive bacteriological methods for the detection of M. mycoides subsp. mycoides have been replaced by molecular genetic techniques in the last two decades, these latter approaches require well-equipped laboratories and specialized personnel for the diagnosis. This is a handicap in areas where CBPP is endemic and early diagnosis is essential. RESULTS We present a rapid, sensitive and specific diagnostic tool for M. mycoides subsp. mycoides detection based on isothermal loop-mediated amplification (LAMP) that is applicable to field conditions. The primer set developed is highly specific and sensitive enough to diagnose clinical cases without prior cultivation of the organism. The LAMP assay detects M. mycoides subsp. mycoides DNA directly from crude samples of pulmonary/pleural fluids and serum/plasma within an hour using a simple dilution protocol. A photometric detection of LAMP products allows the real-time visualisation of the amplification curve and the application of a melting curve/re-association analysis presents a means of quality assurance based on the predetermined strand-inherent temperature profile supporting the diagnosis. CONCLUSION The CBPP LAMP developed in a robust kit format can be run on a battery-driven mobile device to rapidly detect M. mycoides subsp. mycoides infections from clinical or post mortem samples. The stringent innate quality control allows a conclusive on-site diagnosis of CBPP such as during farm or slaughter house inspections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have successfully achieved the integration of isothermal amplification and the subsequent analysis of specific gene fragments on poly(methyl methacrylate) microchips. In our experiments, loop-mediated isothermal amplification, which can offer higher specificity and efficiency than PCR, has been performed at a constant temperature (65 degreesC). After amplification, products could be either examined by the integrated microchip-based electrophoresis or directly observed by naked eye with SYBR Green I added into the reaction solution. By such an integrated microsystem, the amplification and the subsequent analysis of prostate-specific antigen gene with template concentration at 23 fg/muL could be finished within 15 min, which demonstrates its advantages of high specificity, good reproducibility, and fast speed in gene detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La prima parte del nostro studio riguarda la tecnica LAMP (Loop-mediated isothermal amplification), una tecnica di amplificazione isotermica recentemente inventata (Notomi et al., 2000). Essa presenta notevoli vantaggi rispetto alle tradizionali PCR: non necessita di strumentazioni sofisticate come i termociclatori, può essere eseguita da personale non specializzato, è una tecnica altamente sensibile e specifica ed è molto tollerante agli inibitori. Tutte queste caratteristiche fanno sì che essa possa essere utilizzata al di fuori dei laboratori diagnostici, come POCT (Point of care testing), con il vantaggio di non dover gestire la spedizione del campione e di avere in tempi molto brevi risultati paragonabili a quelli ottenuti con la tradizionale PCR. Sono state prese in considerazione malattie infettive sostenute da batteri che richiedono tempi molto lunghi per la coltivazione o che non sono addirittura coltivabili. Sono stati disegnati dei saggi per la diagnosi di patologie virali che necessitano di diagnosi tempestiva. Altri test messi a punto riguardano malattie genetiche del cane e due batteri d’interesse agro-alimentare. Tutte le prove sono state condotte con tecnica real-time per diminuire il rischio di cross-contaminazione pur riuscendo a comprendere in maniera approfondita l’andamento delle reazioni. Infine è stato messo a punto un metodo di visualizzazione colorimetrico utilizzabile con tutti i saggi messi a punto, che svincola completamente la reazione LAMP dall’esecuzione in un laboratorio specializzato. Il secondo capitolo riguarda lo studio dal punto di vista molecolare di un soggetto che presenza totale assenza di attività mieloperossidasica all’analisi di citochimica automatica (ADVIA® 2120 Hematology System). Lo studio è stato condotto attraverso amplificazione e confronto dei prodotti di PCR ottenuti sul soggetto patologico e su due soggetti con fenotipo wild-type. Si è poi provveduto al sequenziamento dei prodotti di PCR su sequenziatore automatico al fine di ricercare la mutazione responsabile della carenza di MPO nel soggetto indicato.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les interactions ARN/ARN de type kissing-loop sont des éléments de structure tertiaire qui jouent souvent des rôles clés chez les ARN, tant au niveau fonctionnel que structural. En effet, ce type d’interaction est crucial pour plusieurs processus dépendant des ARN, notamment pour l’initiation de la traduction, la reconnaissance des ARN antisens et la dimérisation de génome rétroviral. Les interactions kissing-loop sont également importantes pour le repliement des ARN, puisqu’elles permettent d’établir des contacts à longue distance entre différents ARN ou encore entre les domaines éloignés d’un même ARN. Ce type d’interaction stabilise aussi les structures complexes des ARN fonctionnels tels que les ARNt, les riborégulateurs et les ribozymes. Comme d’autres ARN fonctionnels, le ribozyme VS de Neurospora contient une interaction kissing-loop importante. Celle-ci est impliquée dans la reconnaissance du substrat et se forme entre la tige-boucle I (stem-loop I, SLI) du substrat et la tige-boucle V (stem-loop V, SLV) du domaine catalytique. Des études biochimiques ont démontré que l’interaction kissing-loop I/V, dépendante du magnésium, implique trois paires de bases Watson-Crick (W-C). De plus, cette interaction est associée à un réarrangement de la structure du substrat, le faisant passer d’une conformation inactive dite unshifted à une conformation active dite shifted. Les travaux présentés dans cette thèse consistent en une caractérisation structurale et thermodynamique de l’interaction kissing-loop I/V du ribozyme VS, laquelle est formée de fragments d’ARN représentant les tige-boucles I et V dérivées du ribozyme VS (SLI et SLV). Cette caractérisation a été réalisée principalement par spectroscopie de résonance magnétique nucléaire (RMN) et par titrage calorimétrique isotherme (isothermal titration calorimetry, ITC) en utilisant différents complexes SLI/SLV dans lesquels l’ARN SLV est commun à tous les complexes, alors que différentes variations de l’ARN SLI ont été utilisées, soit en conformation shiftable ou preshifted. Les données d’ITC ont permis de démontrer qu’en présence d’une concentration saturante de magnésium, l’affinité d’un substrat SLI preshifted pour SLV est extrêmement élevée, rendant cette interaction plus stable que ce qui est prédit pour un duplexe d’ARN équivalent. De plus, l’étude effectuée par ITC montre que des ARN SLI preshifted présentent une meilleure affinité pour SLV que des ARN SLI shiftable, ce qui a permis de calculer le coût énergétique associé au réarrangement de structure du substrat. En plus de confirmer la formation des trois paires de bases W-C prédites à la jonction I/V, les études de RMN ont permis d’obtenir une preuve structurale directe du réarrangement structural des substrats SLI shiftable en présence de magnésium et de l’ARN SLV. La structure RMN d’un complexe SLI/SLV de grande affinité démontre que les boucles terminales de SLI et SLV forment chacune un motif U-turn, ce qui facilite l’appariement W-C intermoléculaire. Plusieurs autres interactions ont été définies à l’interface I/V, notamment des triplets de bases, ainsi que des empilements de bases. Ces interactions contribuent d’ailleurs à la création d’une structure présentant un empilement continu, c’est-à-dire qui se propage du centre de l’interaction jusqu’aux bouts des tiges de SLI et SLV. Ces études de RMN permettent donc de mieux comprendre la stabilité exceptionnelle de l’interaction kissing-loop I/V au niveau structural et mènent à l’élaboration d’un modèle cinétique de l’activation du substrat par le ribozyme VS. En considérant l’ensemble des données d’ITC et de RMN, l’étonnante stabilité de l’interaction I/V s’explique probablement par une combinaison de facteurs, dont les motifs U-turn, la présence d’un nucléotide exclu de la boucle de SLV (U700), la liaison de cations magnésium et l’empilement de bases continu à la jonction I/V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A better understanding of the paracrine and autocrine regulatory loops within the cumulus-oocyte complex (COC) is fundamental for the improvement of in vitro maturation (IVM) outcomes in humans and domestic species. This review presents the most important local regulators identified in the COC to date with special attention to those secreted by the oocyte and acting on cumulus cells, as well as their roles in different processes crucial for the successful maturation of the COC. An autocrine regulatory loop mediated by epidermal growth factor-like (EGF-like) peptides in cumulus cells triggers COC maturation. During COC differentiation, oocyte secreted factors (OSFs), particularly members of the transforming growth factor-beta (TGF beta) and fibroblast growth factor (FGF) families, regulate meiotic resumption, cumulus expansion, cumulus metabolism, apoptosis and steroidogenesis.