851 resultados para Light filters
Resumo:
Purpose: To investigate the effects of light filters on reading speed in normal and low vision due to age-related macular degeneration (AMD). Methods: Reading speed was determined for 12 subjects with normal vision and 12 subjects with non-exudative AMD using stationary lowercase nonsensical print in Times Roman font and four light filters; a yellow Corning Photochromic Filter (CPF) 450, a grey neural density (ND) filter, an individual filter obtained using the Intuitive Colorimeter® and a clear filter. Results: There was no statistically significant light filter effect on reading speed for the normal subjects. The AMD group demonstrated a statistically significant 5% average improvement in reading speed with the CPF450 compared with the other filters although some AMD subjects had improvements of 10-15%. Conclusions: Light filters obtained using the Intuitive Colorimeter® performed poorly when compared with the CPF450, ND and clear filters for both the study groups. For the AMD group, average reading speed was statistically greater with the CPF450 than the other filters, however it is questionable whether the improvement (5%) would be clinically significant. As some of the subjects with AMD had greater improvements with the CPF450 we advocate clinical assessment of light filters using existing protocols on an individual basis. © 2004 The College of Optometrists.
Resumo:
Purpose: To determine the effect of coloured light filter overlays on reading rates for people with age-related macular degeneration (AMD). Method: Using a prospective clinical trial design, we examined the null hypothesis that coloured light filter overlays do not improve reading rates in AMD when compared to a clear filter. Reading rates for 12 subjects with non-exudative AMD, associated with a relative scotoma and central fixation (mean age 81 years, SD 5.07 years) were determined using the Rate of Reading Test® (printed, nonsense, lower case sans serif, stationary text) with 10 different, coloured light filter overlays (Intuitive Overlays®; figures in brackets are percentage transmission values); rose (78%), pink (78%), purple (67%), aqua (81%), blue (74%), lime-green (86%), mint-green (85%), yellow (93%), orange (83%) and grey (71%). A clear overlay (Roscolene # 00) (360 cdm-2) with 100% transmittance was used as a control. Results: ANOVA indicated that there was no statistically significant difference in reading rates with the coloured light filter overlays compared to the clear filter. Furthermore, chi-squared analysis indicated that the rose, purple and blue filters had a significantly poorer overall ranking in terms of reading rates compared to the other coloured and clear light filters. Conclusion: Coloured light filter overlays are unlikely to provide a clinically significant improvement in reading rates for people with non-exudative AMD associated with a relative scotoma and central fixation. Copyright © Acta Ophthalmol Scand 2004.
Resumo:
A computer-aided method to improve the thickness uniformity attainable when coating multiple substrates inside a thermal evaporation physical vapor deposition unit is presented. The study is developed for the classical spherical (dome-shaped) calotte and also for a plane sector reversible holder setup. This second arrangement is very useful for coating both sides of the substrate, such as antireflection multilayers on lenses. The design of static correcting shutters for both kinds of configurations is also discussed. Some results of using the method are presented as an illustration.
Resumo:
This article suggests a sequence of experiments on the preparation, analysis and some photochemical aspects of potassium tris (oxalato) ferrate(III) trihydrate. The sequence of experiments could be carried out in four or five 4-hour laboratory periods. The new part of this article is related to the kinetics studies involving the ambient illumination as well as the use of the cellophane paper of different colors as light filters. The aspects such as quantum yield, light absorption and photochemical reactions are explored in order to illustrate the relationships between the exposure time, light intensity and wavelength range on the photochemical reactions.
Resumo:
La spectroscopie Raman est un outil non destructif fort utile lors de la caractérisation de matériau. Cette technique consiste essentiellement à faire l’analyse de la diffusion inélastique de lumière par un matériau. Les performances d’un système de spectroscopie Raman proviennent en majeure partie de deux filtres ; l’un pour purifier la raie incidente (habituellement un laser) et l’autre pour atténuer la raie élastique du faisceau de signal. En spectroscopie Raman résonante (SRR), l’énergie (la longueur d’onde) d’excitation est accordée de façon à être voisine d’une transition électronique permise dans le matériau à l’étude. La section efficace d’un processus Raman peut alors être augmentée d’un facteur allant jusqu’à 106. La technologie actuelle est limitée au niveau des filtres accordables en longueur d’onde. La SRR est donc une technique complexe et pour l’instant fastidieuse à mettre en œuvre. Ce mémoire présente la conception et la construction d’un système de spectroscopie Raman accordable en longueur d’onde basé sur des filtres à réseaux de Bragg en volume. Ce système vise une utilisation dans le proche infrarouge afin d’étudier les résonances de nanotubes de carbone. Les étapes menant à la mise en fonction du système sont décrites. Elles couvrent les aspects de conceptualisation, de fabrication, de caractérisation ainsi que de l’optimisation du système. Ce projet fut réalisé en étroite collaboration avec une petite entreprise d’ici, Photon etc. De cette coopération sont nés les filtres accordables permettant avec facilité de changer la longueur d’onde d’excitation. Ces filtres ont été combinés à un laser titane : saphir accordable de 700 à 1100 nm, à un microscope «maison» ainsi qu’à un système de détection utilisant une caméra CCD et un spectromètre à réseau. Sont d’abord présentés les aspects théoriques entourant la SRR. Par la suite, les nanotubes de carbone (NTC) sont décrits et utilisés pour montrer la pertinence d’une telle technique. Ensuite, le principe de fonctionnement des filtres est décrit pour être suivi de l’article où sont parus les principaux résultats de ce travail. On y trouvera entre autres la caractérisation optique des filtres. Les limites de basses fréquences du système sont démontrées en effectuant des mesures sur un échantillon de soufre dont la raie à 27 cm-1 est clairement résolue. La simplicité d’accordabilité est quant à elle démontrée par l’utilisation d’un échantillon de NTC en poudre. En variant la longueur d’onde (l’énergie d’excitation), différentes chiralités sont observées et par le fait même, différentes raies sont présentes dans les spectres. Finalement, des précisions sur l’alignement, l’optimisation et l’opération du système sont décrites. La faible acceptance angulaire est l’inconvénient majeur de l’utilisation de ce type de filtre. Elle se répercute en problème d’atténuation ce qui est critique plus particulièrement pour le filtre coupe-bande. Des améliorations possibles face à cette limitation sont étudiées.
Resumo:
El presente estudio descriptivo de corte transversal, comparó la percepción de color (Test de Farnsworth-100 y de Ishihara) y la sensibilidad al contraste en un grupo de 35 ojos con implantes de lentes intraoculares claros esféricos y otro grupo de 35 ojos con LIOs amarillos esféricos, para evaluar las diferencias entre tener o no el filtro de luz azul. Adicionalmente, después de un examen oftalmológico completo en el ojo a estudiar, se realizaron preguntas de satisfacción POP para evaluar el resultado subjetivo del procedimiento. Todos los pacientes tenían más de 3 meses POP. No se encontraron diferencias estadísticamente significativas en las pruebas de percepción de color que sugirieran que las alteraciones correspondían al filtro de luz azul, y aunque los pacientes con los LIOs amarillos lograron un mejor desempeño en la prueba de sensibilidad al contraste al analizarlos estadísticamente, clínicamente esto no parece tener importancia. La satisfacción general en ambos grupos tuvo una gran puntuación, y dentro de las molestias referidas más frecuentemente y que estaban presentes desde el procedimiento, se encontraban ardor ocular, lagrimeo y dificultad para ver de cerca sin corrección. Según estudios en modelos animales, hay evidencia que sugiere que los LIOs amarillos, al compararlos con LIOs claros, protegen de mejor manera la retina una vez el cristalino se ha retirado. Según este y otros estudios publicados a la fecha, la agudeza visual, sensibilidad al contraste y percepción de color no varían de manera importante entre ambos tipos de lentes en la población general.
Resumo:
Foram conduzidos três ensaios com o objetivo de estudar os efeitos de diferentes métodos de quebra de dormência das sementes, da qualidade da luz e da profundidade de semeadura na germinação e emergência do Xanthium strumarim L. (carrapichão). No primeiro ensaio, sob condições de câmara de crescimento, os tratamentos constaram de 5 métodos de quebra de dormência: mecânico (lixa), químico (H2SO4 conc. por 10 min.), pré-tratamento em água (imersão por 2 horas), físico (choque térmico: água à 80oC por 2 min.) e testemunha, que proporcionaram 100%, 93%, 93%, 87% e 80% de germinação, respectivamente, sem haver diferença estatística entre os mesmos. O pré-tratamento em água apresentou menor índice de velocidade de germinação (IVG) e os demais não diferiram significativamente entre si. No segundo ensaio, também sob condições de câmara de crescimento, os tratamentos de qualidade da luz constaram de 6 filtros de luz, que resultaram nas seguintes porcentagens de germinação: azul - com refletividade máxima a 450 nm (13%), verde-500 nm (33%), vermelho-700 nm (13%), vermelho/distante-760 nm (7%), ausência de luz (26%) e transparente - sem absortividade na região de 380 a 760 nm (testemunha, 73%), indicando sensibilidade das sementes à qualidade de luz. No terceiro ensaio, sob condições de casa-de-vegetação, os tratamentos foram diferentes profundidades de semeadura (0 a 20 cm, em intervalos de 2 cm), sendo que o máximo de emergência ocorreu no intervalo de 0 a 8 cm, no qual foi observado 67% de emergência do carrapichão, com maior índice de velocidade emergência (IVE), sendo que após os 16 cm, praticamente não houve emergência.
Resumo:
Understanding basic information on weed biology contributes to the implementation of appropriate management and control strategies. Thus, this work was developed to evaluate the germination of Spermacoce latifolia Aubl. seeds, an important weed in reforestation areas. The seeds were subjected to dormancy break treatments, in which the mechanical scarification, chemical treatment (H2SO 4 and KNO 3), heat treatment, and control, were evaluated. Three more tests were done determinate the effects of temperature (10, 15, 20, 25, 30 and 35°C), light filters (absence of light and red, green, yellow, distant red, blue, orange and clear light) and water availability (0.0, -0.2, -0.4, -0.6, -0.8 and -1.0 MPa) on the seeds germination and vigor. The treatments were arranged in a completely randomized design with four replications, and the experimental plot was constituted by gerbox plastic boxes with 50 seeds. The mechanical scarification (sanding) provided the best dormancy break, indicating that Spermacoce latifolia seeds have tegument water impermeability. The seeds showed higher germination percentage under conditions of mild water stress (-0.2 MPa) and the optimal temperature was 25°C. The blue light reduced seed germination.
Resumo:
A tireoide sintetiza a tiroxina (T4) e a 3,5,3’-triiodotironina (T3), ambos hormônios apresentam uma função crucial no desenvolvimento do sistema nervoso central, incluindo o sistema visual e a retina. A diminuição dos níveis sanguíneos do T3 e T4 ocasionam uma síndrome denominada de hipotireoidismo, o que pode levar à prejuízos visuais. Os déficits visuais gerados pelo hipotireoidismo estão diretamente relacionados ao período de desenvolvimento do indivíduo. Foi demonstrado em modelos murinos que o hipotireoidismo congênito diminui a espessura da retina, o número de células, e interfere na diferenciação da subpopulação de cones M. Desta forma buscaremos investigar possíveis alterações funcionais na retina de ratos wistar jovens após a tireoidectomia bilateral, utilizando respostas eletrofisiológicas não invasivas. Para tanto, dividimos os ratos em três grupos (controle, sham e tireoidectomizado) cada um contendo ≥ 8 animais. As cirurgias foram realizadas 30 dias pós-natal. Os eletrorretinogramas de campo total foram realizados 10, 15, 20, 25 e 30 dias após a cirurgia, utilizando protocolos para avaliar a resposta escotópica máxima, resposta fotópica (com e sem o uso de filtros de luz) e a resposta ao flicker (12, 15, 18 e 30 Hz). Os parâmetros analisados foram o tempo implícito e a amplitude das ondas a e b. Além disso, realizamos o monitoramento dos parâmetros clínicos dos animais, visando identificar características que indiquem um quadro de hipotireoidismo, bem como a dosagem dos hormônios tireoidianos. Os resultados obtidos demonstraram que em todos dos protocolos de estimulação utilizados no ERG houve diminuição nas amplitudes das ondas a e b nos animais tireoidectomizados em todos os dias avaliados após a cirurgia, quando comparados com animais do grupo controle e sham. Os resultados da avaliação do tempo implícito para ambas as ondas não demonstraram diferença estatística quando comparamos os diversos grupos ao controle. Também podemos constatar uma redução do ganho de peso e tamanho nos animais que sofreram tireoidectomia, associados à redução dos níveis de hormônio tireoidiano (T3). Concluímos dessa forma que os hormônios tireoidianos estão diretamente ligados a alterações funcionais na retina dos animais que sofreram tireoidectomia, bem com, na redução da aquisição de peso e aumento de tamanho.
Resumo:
Tunable wavelength division multiplexing converters based on amorphous SiC multilayer photonic active filters are analyzed. The configuration includes two stacked p-i-n structures (p(a-SiC:H)-i'(a-SiC:H)-n(a-SiC:H)-p(a-SiC:H)-i(a-Si:H)-n(a-Si:H)) sandwiched between two transparent contacts. The manipulation of the magnitude is achieved through appropriated front and back backgrounds. Transfer function characteristics are studied both theoretically and experimentally. An algorithm to decode the multiplex signal is established. An optoelectronic model supports the optoelectronic logic architecture. Results show that the light-activated device combines the demultiplexing operation with the simultaneous photodetection and self-amplification of an optical signal. The output waveform presents a nonlinear amplitude-dependent response to the wavelengths of the input channels. Depending on the wavelength of the external background and irradiation side, it acts either as a short- or a long-pass band filter or as a band-stop filter. A two-stage active circuit is presented and gives insight into the physics of the device.
Resumo:
Visible range to telecom band spectral translation is accomplished using an amorphous SiC pi'n/pin wavelength selector under appropriate front and back optical light bias. Results show that background intensity works as selectors in the infrared region, shifting the sensor sensitivity. Low intensities select the near-infrared range while high intensities select the visible part according to its wavelength. Here, the optical gain is very high in the infrared/red range, decreases in the green range, stays close to one in the blue region and strongly decreases in the near-UV range. The transfer characteristics effects due to changes in steady state light intensity and wavelength backgrounds are presented. The relationship between the optical inputs and the output signal is established. A capacitive optoelectronic model is presented and tested using the experimental results. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Resumo:
Recent developments in biological research, has shown that the initial maximum permissible exposure (MPE) limits for protection of workers from risks associated with artificial optical radiations were more stringent than needed. Using the most recent MPE limits for artificial optical radiation this piece of work was focused on the investigation of the level of visible light attenuation needed by automatic welding filters in case of switching failure. Results from the comparison of different exposure standards were employed in investigating the need of Vis/IR and blue light transmittance requirement for automatic welding filters. Real and arbitrary spectra were taken into consideration for the worst and best case scenarios of artificial optical radiations. An excel worksheet developed during the execution of this project took into consideration the exposure from different light sources and the precision of the spectrometer used in measuring the transmittances of a welding filter. The worksheet was developed and tested with known product properties to investigate the validity of its formulation. The conclusion drawn from this project was that attenuation in the light state will be needed for products with the darkest state shade 11 or higher. Also shown is that current welding filter protects the eye well enough even in the case of switching failure.
Resumo:
Background Yellow filters are sometimes recommended to people with low vision. Our aim was investigate the effects of three commercial yellow filters on visual acuity and contrast sensitivity (with and without glare) and reading (without glare) under conditions of forward light scatter (FLS). Method Fifty-five healthy subjects were assessed with Corning Photochromic Filters (CPFs) 450, 511 and 527 and a filter producing FLS. The effects on log MAR visual acuity, Pelli–Robson contrast sensitivity with and without glare, and reading (measured with MNRead charts) without glare were determined. Results Statistically significant differences were found between the overall effect of glare and between CPFs for visual acuity and contrast sensitivity. A gradual decline in visual acuity, contrast sensitivity and reading with increasing CPF absorption was noted. Conclusion Effects of CPF450, 511, 527 on visual acuity, contrast sensitivity and reading under conditions of FLS were negative but not clinically significant.
Resumo:
Vitamin A palmitate has been used in cosmetics; however, studies report that this substance shows photoreactivity that can lead to loss of safety and efficacy. On the other hand, photostabilizers have been used to increase sunscreen photostability and consequently their safety and effectiveness. Thus, this study aimed to evaluate the influence of photostabilizers on the photoprotective effects of a cosmetic formulation containing UV-filters and vitamin A palmitate. The formulation containing UV-filters was supplemented with vitamin A palmitate and the photostabilizers diethylhexyl 2,6-naphthalate (DEHN), bumetrizole and benzotriazolyl dodecyl p-cresol (BTDC). Hairless mice were treated daily by topical applications and irradiated (UVA/B). Erythema index, transepidermal water loss, histological/histometric analysis and number of sunburn cells (SBC) were evaluated. The results showed that all formulations protected from UV-induced enhancement of erythema and SBC but there was no difference among them. The formulation with no stabilizers reduced viable epidermis thickness due to atrophy induced by UV radiation. Thus, it can be concluded that the presence of photostabilizers influenced the effects of formulations containing UV-filters and vitamin A palmitate, which could be seen by histological and histometric analysis. Furthermore, the formulations containing the stabilizers DEHN and BTDC showed better protective effects on hairless mice skin.
Resumo:
Characteristics of tunable wavelength filters based on a-SiC:H multi-layered stacked cells are studied both theoretically and experimentally. Results show that the light-activated photonic device combines the demultiplexing operation with the simultaneous photodetection and self amplification of an optical signal. The sensor is a bias wavelength current-controlled device that make use of changes in the wavelength of the background to control the power delivered to the load, acting a photonic active filter. Its gain depends on the background wavelength that controls the electrical field profile across the device.