806 resultados para Lente intraocular difractiva


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to describe and compare the ultrasonographic alterations in dogs' eyes submitted to facectomy with or without intraocular lens implant (IOL), to assist in the diagnosis of possible alterations related to the surgical procedure and IOL implantation. Nineteen dogs with cataract (21 eyes) were submitted to phacoemulsification and late postoperative evaluation (at five years). The animals were initially submitted to complete ophthalmological exams which preceded the sonogram. Dogs were divided in three groups: (CA) aphakic dogs (n= 11); (PP) pseudophakic dogs with implantation of two IOLs in piggyback (n=5) and (PL) pseudophakic dogs with implantation of a veterinary IOL (n = 5). The ultrasound was carried under the administration of a topic local anesthetic, with a multi frequency linear transducer of 10 MHz. Biometric eye measurements were also performed. The clinical alterations observed were IOL dislocation, retinal detachment, asteroid hyalosis, and vitreous degeneration. Ultrasound examination was an excellent diagnostic tool, as it was possible to confirm and classify these changes. The piggyback implant reduced the measurements between the ciliary body and the vitreous chamber obtained from the ocular biometry when compared to other usual procedures, with no difference between the axial length and the anterior chamber.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El objetivo del presente estudio ha sido evaluar y analizar resultados tanto clínicos como teóricos para proporcionar un mayor entendimiento del funcionamiento de las lentes intraoculares (LIOs) trifocales. Para ello, se ha realizado una búsqueda bibliográfica, incluyendo tanto artículos de simulaciones en banco óptico como aquellos que muestran resultados clínicos. En la búsqueda se han encontrado artículos sobre tres LIOs trifocales: AT.LISA tri839MP (Carl Zeiss Meditec), FineVision (PhysIOL) y MIOL-Record (Repper-NN). En los estudios teóricos se ha demostrado que las LIOs trifocales presentan una mejora con respecto a las LIOs bifocales en cuanto a visión intermedia pero con una disminución en cuanto a calidad óptica en distancias lejanas y cercanas. Por el contrario, en cuanto a resultados clínicos, las LIOs trifocales proporcionan buenas agudezas visuales en visión lejana y agudezas visuales variables pero siempre aceptables en visión intermedia y cercana. En conclusión, LIOs trifocales ofrecen una opción a aquellos pacientes que necesitan trabajar en visión intermedia y buscan no tener que depender del uso de gafas tras cirugía de catarata.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A uveíte peri e pós-operatória é o maior problema da cirurgia para extração de catarata no cão, sendo considerada o fator mais importante para o sucesso cirúrgico, imediato e tardio. Diversos protocolos pré e pós-operatórios utilizando agentes anti-inflamatórios esteroidais e não-esteroidais têm sido empregados na tentativa de controle da uveíte cirurgicamente induzida. O objetivo do presente estudo foi avaliar a reação inflamatória pós-operatória, clinicamente e por meio da pressão intraocular (PIO), após a cirurgia de facoemulsificação para extração de catarata em cães, com e sem implante de lente intraocular (LIO) em piggyback. Empregaram-se, 25 cães portadores de catarata, subdivididos em dois grupos: G1 (com implante de LIO), G2 (sem implante de LIO). A técnica cirúrgica adotada foi a facoemulsificação bimanual unilateral. Avaliações clínicas e mensurações da PIO foram aferidas antes do procedimento cirúrgico (0) e nos tempos 3, 7, 14, 21, 28 e 60 dias após o ato cirúrgico. Cães do grupo G1 apresentaram sinais clínicos de uveíte visivelmente mais intensos, relativamente aos do G2. Entretanto, a PIO não demonstrou diferença significativa entre os dois grupos analisados, nem entre os olhos operados e os contralaterais. A utilização de duas LIOs humanas em piggyback no cão é exequível, porém suscita mais inflamação e complicações no pós-operatório.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes) received ultraviolet and blue light filter (yellow tinted) IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD]) investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens) difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens) under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To examine a single-optic accommodating intraocular lens (IOL) visual performance by correlating IOL implanted eyes’ defocus curve with the intraocular aberrometric profile and the impact on the quality of life (QOL). Methods: Prospective consecutive case series study including a total of 25 eyes of 14 patients with ages ranging between 52 and 79 years old. All cases underwent cataract surgery with implantation of the single-optic accommodating IOL Crystalens HD (Bausch & Lomb). Distance and near visual acuity outcomes, intraocular aberrations, the defocus curve and QOL (NEI VFQ-25) were evaluated 3 months after surgery. Results: A significant improvement in distance visual acuity was found postoperatively (p = 0.02). Mean postoperative LogMAR uncorrected near visual acuity was 0.44 ± 0.23 (20/30). 60% of eyes had a postoperative addition between 0 and 1.5 diopters (D). The defocus curve showed an area of maximum visual acuity for the levels of defocus corresponding to distance and intermediate vision (−1 to +0.5 D). Postoperative intermediate visual acuity correlated significantly some QOL indices (r ≥ 0.51, p ≤ 0.03; difficulty in going down steps or seeing how people react to things that patient says) as well as with J0 component of manifest cylinder. Postoperative distance-corrected near visual acuity correlated significantly with age (r = 0.65, p < 0.01). Conclusions: This accommodating IOL seems to be able to restore the distance visual function as well as to provide an improvement in intermediate and near vision with a significant impact on patient's QOL, although limited by age and astigmatism. Future studies with larger sample sizes should confirm all these trends.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Monográfico con el título: 'Visión y deporte'. Resumen tomado de la publicación

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)