942 resultados para Leg press


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abad, CCC, Prado, ML, Ugrinowitsch, C, Tricoli, V, and Barroso, R. Combination of general and specific warm-ups improves leg-press one repetition maximum compared with specific warm-up in trained individuals. J Strength Cond Res 25(8): 2242-2245, 2011-Accurate assessment of muscular strength is critical for exercise prescription and functional evaluation. The warm-up protocol may affect the precision of the 1 repetition maximum (1RM) test. Testing guidelines recommend performing both general and specific warm-ups before strength tests. The general warm-up intends to raise muscle temperature, whereas the specific warm-up aims to increase neuromuscular activation. Although there is scientific evidence for performing the specific warm-up, the effects of general warm-up on strength tests are still unclear. The purpose of this study was to investigate whether the combination of a general with a specific warm-up (G + SWU) protocol would improve leg press 1RM values compared with a specific warm-up (SWU) protocol. Thirteen participants were tested for leg-press 1RM under 2 warm-up conditions. In the first condition, participants performed the SWU only, which was composed of 1 set of 8 repetitions at approximately 50% of the estimated 1RM followed by another set of 3 repetitions at 70% of the estimated 1RM. In the second condition (G + SWU), participants performed the 1RM test after a 20-minute general warm-up on a stationary bicycle at 60% of HRmax and the same specific warm-up as in the SWU. Values of 1RM in SWU and in G + SWU were compared by a paired t-test, and significance level was set at p <= 0.05. Strength values were on average 8.4% (p = 0.002) higher in the G + SWU compared with the SWU. These results suggest that the G + SWU induced temperature-dependent neuromuscular adjustments that increased muscle force production capacity. Therefore, these results support the recommendations of the testing guidelines to perform a moderate intensity general warm-up in addition to the specific warm-up before maximum strength assessments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Verificar a influência de dois diferentes intervalos de recuperação (IR) entre as séries no exercício leg-press sobre o número e sustentabilidade das repetições e no volume total, em idosas não treinadas. MÉTODOS: Onze idosas (66,5 ± 5,0 anos; 59,2 ± 9,1kg; 146,4 ± 34,9cm) foram submetidas a duas sessões experimentais de exercícios com pesos com intensidade de 15 repetições máximas. Cada sessão experimental foi composta por três séries realizadas até a fadiga muscular utilizando IR de um (IR-1) ou três minutos (IR-3). As sessões experimentais foram separadas por, no mínimo, 48 horas. Todas as participantes realizaram ambos os protocolos e um delineamento cross-over balanceado foi utilizado para determinar a ordem das sessões experimentais. RESULTADOS: Para ambos os IR entre as séries, reduções significativas (P < 0,05) no número e na sustentabilidade das repetições foram observadas da primeira para a segunda e terceira séries e da segunda para a terceira séries. Diferenças significativas (P < 0,05) entre os IR foram observadas nas duas séries finais. O volume total da sessão realizada com IR-3 foi estatisticamente superior (20,4%; P < 0,05) quando comparada a sessão IR-1. CONCLUSÃO: O número e a sustentabilidade das repetições e o volume total de treino de idosas não treinadas são influenciados pelo IR empregado entre as séries. Maiores IR devem ser utilizados quando a finalidade for otimizar o volume de treino por meio da sustentabilidade das repetições. Em contrapartida, menores IR devem ser utilizados quando a meta for obter maiores níveis de fadiga muscular.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rectus femoris was analysed in 10 volunteers during knee flexion and extension with the feet in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an A/D conversion plaque (Model CAD 10/26), software specially designed to record and analyse the signals, Horizontal Leg Press, and electrogoniometers were used. The rectus femoris muscle showed strong potentials at the beginning of knee extension. In the simultaneous bendings of the knee and hip the activity was strong toward the end of the movement. The rectus femoris showed a similar activity both in the upper and lower platforms. As for foot positions, the rectus femoris showed the smallest potentials with the foot in plantar flexion and the largest ones with the foot in dorsal flexion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The gastrocnemius was analysed in 10 male volunteers during knee flexion and extension with the foot in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an AID conversion plaque (Model CAD 10/26), a software specially designed to record and analyse the signals, a horizontal leg press, and electrogoniometers were used. The gastrocnemius muscle showed strong potentials at the end of knee extension and beginning of knee flexion. The muscle presented a similar activity both in the zipper and lower platforms. As to bilateral action, the right gastrocnemius presented stronger potentials on the upper platforms, whereas the potentials were bilaterally similar on the lower platforms. As for foot position, the gastrocnemius presented strong potentials when the foot was in plantar flexion. The remaining positions had no effect on the work of the muscle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to quantify energy expenditure (EE) during multiple sets of leg press (LP) and bench press (BP) exercises in 10 males with at least 1 yr of resistance training (RT). The subjects underwent two sessions to determine 1 repetition maximum (1RM) on the BP and LP and one protocol consisting of a warm up and 4 sets for 10 repetitions at 70% 1RM with a 3-min rest period between sets for each exercise. Energy expenditure was calculated as the sum of oxygen uptake (aerobic component), EPOC, and lactate production (anaerobic component). There were no significant differences in EE between exercises for sets 1 to 4 and the total energy expended. However, statistical analysis revealed a significant difference (P<0.05) between exercises in RT economy (BP, 0.0206 ± 0.0044 kcal·kg-1 vs. LP, 0.0051 ± 0.0015 kcal·kg-1). Within exercise comparison showed set 4 was significantly different from sets 1 and 3 for BP, and for LP a significant difference was found between set 4 and sets 1, 2 and 3. Our results point to an increase in EE during multiple sets at 70% 1RM and show that in spite of the difference in muscle mass involved and total work done during each type of exercise, EE was not different due to greater economy during the LP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN] Information about anaerobic energy production and mechanical efficiency that occurs over time during short-lasting maximal exercise is scarce and controversial. Bilateral leg press is an interesting muscle contraction model to estimate anaerobic energy production and mechanical efficiency during maximal exercise because it largely differs from the models used until now. This study examined the changes in muscle metabolite concentration and power output production during the first and the second half of a set of 10 repetitions to failure (10RM) of bilateral leg press exercise. On two separate days, muscle biopsies were obtained from vastus lateralis prior and immediately after a set of 5 or a set of 10 repetitions. During the second set of 5 repetitions, mean power production decreased by 19% and the average ATP utilisation accounted for by phosphagen decreased from 54% to 19%, whereas ATP utilisation from anaerobic glycolysis increased from 46 to 81%. Changes in contraction time and power output were correlated to the changes in muscle Phosphocreatine (PCr; r = -0.76; P<0.01) and lactate (r = -0.91; P<0.01), respectively, and were accompanied by parallel decreases (P<0.01-0.05) in muscle energy charge (0.6%), muscle ATP/ADP (8%) and ATP/AMP (19%) ratios, as well as by increases in ADP content (7%). The estimated average rate of ATP utilisation from anaerobic sources during the final 5 repetitions fell to 83% whereas total anaerobic ATP production increased by 9% due to a 30% longer average duration of exercise (18.4 +/- 4.0 vs 14.2 +/- 2.1 s). These data indicate that during a set of 10RM of bilateral leg press exercise there is a decrease in power output which is associated with a decrease in the contribution of PCr and/or an increase in muscle lactate. The higher energy cost per repetition during the second 5 repetitions is suggestive of decreased mechanical efficiency.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The most typical maximum tests for measuring leg muscle performance are the one-repetition maximum leg press test (1RMleg) and the isokinetic knee extension/flexion (IKEF) test. Nevertheless, their inter-correlations have not been well documented, mainly the predicted values of these evaluations. This correlational and regression analysis study involved 30 healthy young males aged 18-24y, who have performed both tests. Pearson's product moment correlation between 1RMleg and IKEF varied from 0.20 to 0.69 and the more exact predicted test was to 1RMleg (R2 = 0.71). The study showed correlations between 1RMleg and IKEF although these tests are different (isotonic vs. isokinetic) and provided further support for cross determination of 1RMleg and IKEF by linear and multiple linear regression analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this present study was to investigate on the effects of concurrent training with blood flow restriction (BFR-CT) and concurrent training (CT) on the aerobic fitness, muscle mass and muscle strength in a cohort of older individuals. 25 healthy older adults (64.7±4.1 years; 69.33±10.8 kg; 1.6±0.1 m) were randomly assigned to experimental groups: CT (n=8, endurance training (ET), 2 days/week for 30-40 min, 50-80% VO2peak and RT, 2 days/week, leg press with 4 sets of 10 reps at 70-80% of 1-RM with 60 s rest), BFR-CT (n=10, ET, similar to CT, but resistance training with blood flow restriction: 2 days/week, leg press with 1 set of 30 and 3 sets of 15 reps at 20-30% 1-RM with 60 s rest) or control group (n=7). Quadriceps cross-sectional area (CSAq), 1-RM and VO2peak were assessed pre- and post-examination (12 wk). The CT and BFR-CT showed similar increases in CSAq post-test (7.3%, P<0.001; 7.6%, P<0.0001, respectively), 1-RM (38.1%, P<0.001; 35.4%, P=0.001, respectively) and VO2peak (9.5%, P=0.04; 10.3%, P=0.02, respectively). The BFR-CT promotes similar neuromuscular and cardiorespiratory adaptations as CT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física