996 resultados para Laser refractive surgery


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To calculate theoretically the errors in the estimation of corneal power when using the keratometric index (nk) in eyes that underwent laser refractive surgery for the correction of myopia and to define and validate clinically an algorithm for minimizing such errors. Methods: Differences between corneal power estimation by using the classical nk and by using the Gaussian equation in eyes that underwent laser myopic refractive surgery were simulated and evaluated theoretically. Additionally, an adjusted keratometric index (nkadj) model dependent on r1c was developed for minimizing these differences. The model was validated clinically by retrospectively using the data from 32 myopic eyes [range, −1.00 to −6.00 diopters (D)] that had undergone laser in situ keratomileusis using a solid-state laser platform. The agreement between Gaussian (PGaussc) and adjusted keratometric (Pkadj) corneal powers in such eyes was evaluated. Results: It was found that overestimations of corneal power up to 3.5 D were possible for nk = 1.3375 according to our simulations. The nk value to avoid the keratometric error ranged between 1.2984 and 1.3297. The following nkadj models were obtained: nkadj= −0.0064286r1c + 1.37688 (Gullstrand eye model) and nkadj = −0.0063804r1c + 1.37806 (Le Grand). The mean difference between Pkadj and PGaussc was 0.00 D, with limits of agreement of −0.45 and +0.46 D. This difference correlated significantly with the posterior corneal radius (r = −0.94, P < 0.01). Conclusions: The use of a single nk for estimating the corneal power in eyes that underwent a laser myopic refractive surgery can lead to significant errors. These errors can be minimized by using a variable nk dependent on r1c.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To report a very successful outcome obtained with the fitting of a new-generation hybrid contact lens of reverse geometry in a thin cornea with extreme irregularity due to the presence of a central island after unsuccessful myopic excimer laser refractive surgery. Methods: A 32-year-old man attended to our clinic complaining of very poor vision in his right eye after bilateral laser in situ keratomileusis (treatment or surgery) for myopia correction and some additional retreatments afterward. After a comprehensive ocular evaluation, contact lens fitting with a reverse geometry hybrid contact lens (SynergEyes PS, SynergEyes, Carlsbad, CA) was proposed as a solution for this case. Visual, refractive, and ocular aberrometric outcomes with the contact lens were evaluated. Results: Distance visual acuity improved from a prefitting uncorrected value of 20/200 to a postfitting corrected value of 20/16. Prefitting manifest refraction was +6.00 sphere and −3.00 cylinder at 70°, with a corrected distance visual acuity of 20/40. Higher order root mean square for a 5-mm pupil changed from a prefitting value of 1.45 to 0.34 µm with the contact lens. The contact lens wearing was reported as comfortable, and the patient was very satisfied with this solution. Conclusions: The SynergEyes PS contact lens seems to be an excellent option for the visual rehabilitation of corneas with extreme irregularity after myopic excimer laser surgery, minimizing the level of higher order aberrations and providing an excellent visual outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For more than a century it has been known that the eye is not a perfect optical system, but rather a system that suffers from aberrations beyond conventional prescriptive descriptions of defocus and astigmatism. Whereas traditional refraction attempts to describe the error of the eye with only two parameters, namely sphere and cylinder, measurements of wavefront aberrations depict the optical error with many more parameters. What remains questionable is the impact these additional parameters have on visual function. Some authors have argued that higher-order aberrations have a considerable effect on visual function and in certain cases this effect is significant enough to induce amblyopia. This has been referred to as ‘higher-order aberration-associated amblyopia’. In such cases, correction of higher-order aberrations would not restore visual function. Others have reported that patients with binocular asymmetric aberrations display an associated unilateral decrease in visual acuity and, if the decline in acuity results from the aberrations alone, such subjects may have been erroneously diagnosed as amblyopes. In these cases, correction of higher-order aberrations would restore visual function. This refractive entity has been termed ‘aberropia’. In order to investigate these hypotheses, the distribution of higher-order aberrations in strabismic, anisometropic and idiopathic amblyopes, and in a group of visual normals, was analysed both before and after wavefront-guided laser refractive correction. The results show: (i) there is no significant asymmetry in higher-order aberrations between amblyopic and fixing eyes prior to laser refractive treatment; (ii) the mean magnitude of higher-order aberrations is similar within the amblyopic and visually normal populations; (iii) a significant improvement in visual acuity can be realised for adult amblyopic patients utilising wavefront-guided laser refractive surgery and a modest increase in contrast sensitivity was observed for the amblyopic eye of anisometropes following treatment (iv) an overall trend towards increased higher-order aberrations following wavefront-guided laser refractive treatment was observed for both visually normal and amblyopic eyes. In conclusion, while the data do not provide any direct evidence for the concepts of either ‘aberropia’ or ‘higher-order aberration-associated amblyopia’, it is clear that gains in visual acuity and contrast sensitivity may be realised following laser refractive treatment of the amblyopic adult eye. Possible mechanisms by which these gains are realised are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To compare the intraocular pressure (IOP) before and after Laser In Situ Keratomileusis (LASIK), measured by Diaton, Perkins, and noncontact air pulse tonometers. Methods. Fifty-seven patients with a mean age of 34.88 were scheduled for myopia LASIK treatment. Spherical equivalent refraction (SER), corneal curvature (K), and central corneal thickness (CCT) and superior corneal thickness (SCT) were obtained before and after LASIK surgery. IOP values before and after surgery were measured using Diaton, Perkins, and noncontact air pulse tonometers. Results. The IOP values before and after LASIK surgery using Perkins tonometer and air tonometers were statistically significant (). However, no significant differences were found () for IOP values measured with Diaton tonometer. CCT decreases significantly after surgery () but no statistical differences were found in SCT (). Correlations between pre- and postsurgery were found for all tonometers used, with and for the air pulse tonometer, and for Perkins, and and for Diaton. Conclusion. Transpalpebral tonometry may be useful for measuring postsurgery IOP after myopic LASIK ablation because this technique is not influenced by the treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate results of two surface excimer laser refractive surgery techniques-photorefractive keratectomy (PRK) and butterfly laser epithelial keratomileusis (butterfly LASEK). METHODS: A prospective, randomized, double-masked study of 51 patients (102 eyes) who underwent laser refractive surgery. One eye of each patient was randomized to be operated with PRK and the fellow eye with butterfly LASEK Patients were followed for 1 year. RESULTS: No significant difference between groups for distance uncorrected visual acuity (UCVA) (P=.559) was noted. At 1 year, 98% (50 eyes) in the PRK group and 96.1% (49 eyes) in the butterfly LASEK group reached UCVA of 20/20. Predictability, efficacy, safety, and stability were not statistically significant between groups. Safety index was 1.0 for PRK and 0.996 for butterfly LASEK, One eye in the butterfly LASEK group lost one line of best-spectacle corrected visual acuity. At 12 months, 94.1% (48 eyes) and 86.3% (44 eyes) in the PRK and butterfly LASEK groups (P=.188), respectively, had a spherical equivalent refraction of +/- 0.50 diopters. Slight haze was observed in both groups. A statistical difference in haze between the groups was observed only in the first postoperative month, with higher intensity in the butterfly LASEK group (0.18 +/- 0.39) compared to the PRK group (0.08 +/- 0.21) (P=.04). CONCLUSIONS: Butterfly LASEK had similar predictability, efficacy, safety, stability, and haze incidence to PRK for the treatment of low to moderate myopia. However, on the second postoperative day, PRK showed better UCVA than butterfly LASEK.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To validate clinically a new method for estimating the corneal power (P,) using a variable keratometric index (nkadj) in eyes with previous laser refractive surgery. Setting. University of Alicante and Medimar International Hospital (Oftalmar), Alicante, (Spain). Design. Retrospective case series. Methods. This retrospective study comprised 62 eyes of 62 patients that had undergone myopic LASIK surgery. An algorithm for the calculation of 11kadj was used for the estimation of the adjusted keratometric corneal power (Pkadj). This value was compared with the classical keratometric corneal power (Pk), the True Net Power (TNP), and the Gaussian corneal power (PcGauss). Likewise, Pkadj was compared with other previously described methods. Results. Differences between PcGauss and P, values obtained with all methods evaluated were statistically significant (p < 0.01). Differences between Pkadj and PcGauss were in the limit of clinical significance (p < 0.01, loA [ - 0.33,0.60] D). Differences between Pkadj and TNP were not statistically and clinically significant (p = 0.319, loA [- 0.50,0.44] D). Differences between Pkadj and previously described methods were statistically significant (p < 0.01), except with PcHaigisL (p = 0.09, loA [ - 0.37,0.29] D). Conclusion. The use of the adjusted keratometric index (nkadj) is a valid method to estimate the central corneal power in corneas with previous myopic laser refractive surgery, providing results comparable to PcHaigisL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare corneal reepithelialization, pain scores, ocular discomfort, and tear production after photorefractive keratectomy (PRK) and butterfly laser epithelial keratomileusis (LASEK). METHODS: This prospective, randomized, double-masked study comprised 102 eyes of 51 patients who underwent laser refractive surgery. Each patient was randomized to have one eye operated on with PRK and the other with butterfly LASEK. Patients were followed for 1 year. RESULTS: The mean reepithelialization time in the PRK group was 4.35 +/- 0.48 days (range: 4 to 5 days) and 4.75 +/- 0.72 days (range: 4 to 6 days) in the butterfly LASEK group (P<.002). Pain scores and ocular discomfort were not statistically different between groups, although a trend towards a lower pain level with PRK was noted (3.31 +/- 4.09 vs 4.43 +/- 4.27; P=.18). Schirmer test values were significantly reduced from preoperative levels through 12 months with both PRK (23.6 +/- 8.1 vs 19.4 +/- 10.1; P<.002) and butterfly LASEK (22.4 +/- 8.7 vs 18.9 +/- 9.7; P=.01); however, no difference between groups was noted at any time. CONCLUSIONS: Photorefractive keratectomy showed a modest but statistically significant shorter reepithelialization time and a tendency towards lower pain scores than butterfly LASEK. The reepithelialization time was strongly associated with the duration of surgery in both techniques. A similar reduction of Schirmer test values was observed up to 1 year postoperatively in both groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare the manifest refractive cylinder (MRC) predictability of myopic astigmatism laser in situ keratomileusis (LASIK) between eyes with low and high ocular residual astigmatism (ORA). Setting: London Vision Clinic, London, United Kingdom. Design: Retrospective case study. Methods: The ORA was considered the vector difference between the MRC and the corneal astigmatism. The index of success (IoS), difference vector ÷ MRC, was analyzed for different groups as follows: stage 1, low ORA (ORA ÷ MRC <1), high ORA (ORA ÷ MRC ≥1); stage 2, low ORA group reduced to match the high ORA group for MRC; stage 3, grouped by ORA magnitude with low ORA (<0.50 diopters [D]), mid ORA (0.50 to 1.24 D), and high ORA (≥1.25 D); stage 4, high ORA group subdivided into low (<0.75 D) and high (≥0.75 D) corneal astigmatism. Results: For stage 1, the mean preoperative MRC and mean IoS were −1.32 D ± 0.65 (SD) (range −0.55 to −3.77 D) and 0.27, respectively, for low ORA and −0.79 ± 0.20 D (range −0.56 to −2.05 D) and 0.37, respectively, for high ORA. For stage 2, the mean IoS increased to 0.32 for low ORA. For stage 3, the mean IoS was 0.28, 0.29, and 0.31 for low ORA, mid ORA, and high ORA, respectively. For stage 4, the mean IoS was 0.20 for high ORA/low corneal astigmatism and 0.35 for high ORA/high corneal astigmatism. Conclusions: The MRC predictability was slightly worse in eyes with high ORA when grouped by the ORA ÷ MRC. Matching for the MRC and grouping by ORA magnitude resulted in similar predictability; however, eyes with high ORA and high corneal astigmatism were less predictable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To study the visual and refractive outcomes after laser-assisted subepithelial keratectomy (LASEK) performed with a 213 nm solid-state laser for a broad range of refractive errors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose:  To study the concentrations of diadenosine polyphosphates in the ocular surface after PRK and LASIK. Methods:  Sixty-one patients (30 males and 31 females) with ages ranging from 20 to 63 (34.04 ± 9.13 years) were recruited in Balear Institute of Ophthalmology, Palma de Mallorca, Spain. LASIK was performed in 92 eyes of 46 patients and PRK in 25 eyes of 15 patients. Variations in the levels of diadenosine polyphosphate (Ap4A and Ap5A), Schirmer I (Jones test), TBUT, corneal staining together with the Dry Eye Questionnaire to evaluate discomfort and dryness were studied. All tests were performed at the preoperative visit and at 1-day, 2-week, 1-month and 3-month postoperative visits. Results:  Ap4A showed a 5 and 3.5 fold increase at the 1-day visit for LASIK and PRK, respectively. LASIK patients continued having higher statistically significant concentrations (p = 0.01) all over the follow-up. Ap5A showed no significant differences at any visit. Tear volume decreased during the 3 months in LASIK. The PRK cases had a normal volume at 1 month. TBUT in LASIK increased at the 1-day visit (p = 0,002) and decreased from the 2 weeks onwards and for the PRK, decreased by a 35% at the 1-day visit and kept reduced for a month. Discomfort only increased at the 1-day visit (p = 0.007). Dryness frequency was similar in all visits. Conclusions:  Ap4A levels only are increased in refractive surgery patients during the first day after the surgery. This increasing suggests that Ap4A may help accelerating the healing process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare changes in corneal hysteresis (CH) and the corneal resistance factor (CRF) in myopic and hyperopic laser in situ keratomileusis (LASIK) and evaluate their relationship to the number of photoablative pulses delivered, a surrogate for ablation volume. SETTING: Cleveland Clinic Cole Eye Institute, Cleveland, Ohio, USA. METHODS: Preoperative and 1-week postoperative Ocular Response Analyzer measurements in eyes that had femtosecond-assisted LASIK were studied retrospectively. Changes in CH and CRF were compared and tested for correlation with the number of excimer laser pulses. RESULTS: Thirteen myopic eyes and 11 hyperopic eyes were evaluated. Preoperative corneal thickness, CH, CRF, programmed correction magnitude, flap thickness, and total number of fixed spotsize photoablative pulses were similar in the 2 groups (P>.1). Decreases in CH and CRF were greater after myopic LASIK than after hyperopic LASIK (P<.005), and changes in CRF were correlated with the number of excimer laser pulses in the myopic group only (r = -0.63, P = .02). Regardless of ablation profile, changes in CH were more strongly correlated with preoperative CH values than with attempted ablation volume. CONCLUSIONS: With comparable flap thickness and attempted ablation volumes, myopic photoablation profiles were associated with greater decreases in CRF and CH than hyperopic profiles. Results indicate that preoperative corneal biomechanical status, ablation volume, and the spatial distribution of ablation are important factors that affect corneal resistance and viscous dissipative properties differently. Preferential tissue removal in the natively thicker paracentral cornea in hyperopia may partially account for the rarity of ectasia after hyperopic LASIK.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To analyze the effects of variations in femtosecond laser energy level on corneal stromal cell death. and inflammatory cell influx following flap creation in a rabbit model. METHODS: Eighteen rabbits were stratified in three different groups according to level of energy applied for flap creation (six animals per group). Three different energy levels were chosen for both the lamellar and side cut; 2.7 mu J (high energy), 1.6 mu J (intermediate energy), and 0.5 mu J (low energy) with a 60 kHz, model II, femtosecond laser (IntraLase). The opposite eye of each rabbit served as a control. At the 24-hour time point after surgery, all rabbits were euthanized and the comeoscleral rims were analyzed for the levels of cell death and inflammatory cell influx with the terminal uridine deoxynucleotidyl transferase dUTP-nick end labeling (TUNEL) assay and immunocytochemistry for monocyte marker CD11b, respectively. RESULTS: The high energy group (31.9 +/- 7.1 [standard error of mean (SEM) 2.9]) had significantly more TUNEL positive cells in the central flap compared to the intermediate (22.2 +/- 1.9 [SEM 0.8], P=.004), low (17.9 +/- 4.0 [SEM 1.6], P <= .001), and control eye (0.06 +/- 0.02 [SEM 0.009], P <= .001) groups. The intermediate and low energy groups also had significantly more TUNEL positive cells than the control groups (P <= .001). The difference between the intermediate and low energy levels was not significant (P=.56). The mean for CD11b-positive cells/400x field at the flap edge was 26.1 +/- 29.3 (SEM 11.9), 5.8 +/- 4.1 (SEM 1.6), 1.6 +/- 4.1 (SEM 1.6), and 0.005 +/- 0.01 (SEM 0.005) for high energy, intermediate energy, low energy, and control groups, respectively. Only the intermediate energy group showed statistically more inflammatory cells than control eyes (P = .015), most likely due to variability between eyes. CONCLUSIONS: Higher energy levels trigger greater cell death when the femtosecond laser is used to create corneal flaps: Greater corneal inflammatory cell infiltration is observed with higher femtosecond laser energy levels. [J Refract Surg. 2009;25:869-874.] doi:10.3928/1081597X-20090917-08

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate in a pilot study the visual, refractive, corneal topographic, and aberrometric changes after wavefront-guided LASIK or photorefractive keratectomy (PRK) using a high-resolution aberrometer to calculate the treatment for aberrated eyes. METHODS: Twenty aberrated eyes of 18 patients undergoing wavefront-guided LASIK or PRK using the VISX STARS4IR excimer laser and the iDesign aberrometer (Abbott Medical Optics, Inc., Santa Ana, CA) were enrolled in this prospective study. Three groups were differentiated: keratoconus post-CXL group including 11 keratoconic eyes (10 patients), post-LASIK group including 5 eyes (5 patients) with previous decentered LASIK treatments, and post-RK group including 4 eyes (3 patients) with previous radial keratotomy. Visual, refractive, contrast sensitivity, corneal topographic, and ocular aberrometric changes were evaluated during a 6-month follow-up. RESULTS: An improvement in uncorrected (UDVA) and corrected visual acuity (CDVA) associated with a reduction in the spherical equivalent was observed in the three groups, but was only statistically significant in the keratoconus post-CXL and post-LASIK groups (P ≤ .04). All eyes gained one or more lines of CDVA after surgery. Improvements in contrast sensitivity were observed in the three groups, but they were only statistically significant in the keratoconus post-CXL and post-LASIK groups (P ≤ .04). Regarding aberrations, a reduction was observed in trefoil aberrations in the keratoconus post-CXL group (P = .05) and significant reductions in higher-order and primary coma aberrations in the post-LASIK group (P = .04). CONCLUSIONS: Wavefront-guided laser enhancements using the evaluated platform seem to be safe and effective to restore the visual function in aberrated eyes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To show that the limited quality of surfaces produced by one model of excimer laser systems can degrade visual performance with a polymethylmethacrylate (PMMA) model. METHODS: A range of lenses of different powers was ablated in PMMA sheets using five DOS-based Nidek EC-5000 laser systems (Nidek Technologies, Gamagori, Japan) from different clinics. Surface quality was objectively assessed using profilometry. Contrast sensitivity and visual acuity were measured through the lenses when their powers were neutralized with suitable spectacle trial lenses. RESULTS: Average surface roughness was found to increase with lens power, roughness values being higher for negative lenses than for positive lenses. Losses in visual contrast sensitivity and acuity measured in two subjects were found to follow a similar pattern. Findings are similar to those previously published with other excimer laser systems. CONCLUSIONS: Levels of surface roughness produced by some laser systems may be sufficient to degrade visual performance under some circumstances.