Comparison of Intraocular Pressure before and after Laser In Situ Keratomileusis Refractive Surgery Measured with Perkins Tonometry, Noncontact Tonometry, and Transpalpebral Tonometry


Autoria(s): Cacho, Isabel; Sánchez Naves, Juan; Batres Valderas, Laura; Carracedo Rodríguez, Juan Gonzalo; Pintor Just, Jesús
Data(s)

2015

Resumo

Purpose. To compare the intraocular pressure (IOP) before and after Laser In Situ Keratomileusis (LASIK), measured by Diaton, Perkins, and noncontact air pulse tonometers. Methods. Fifty-seven patients with a mean age of 34.88 were scheduled for myopia LASIK treatment. Spherical equivalent refraction (SER), corneal curvature (K), and central corneal thickness (CCT) and superior corneal thickness (SCT) were obtained before and after LASIK surgery. IOP values before and after surgery were measured using Diaton, Perkins, and noncontact air pulse tonometers. Results. The IOP values before and after LASIK surgery using Perkins tonometer and air tonometers were statistically significant (). However, no significant differences were found () for IOP values measured with Diaton tonometer. CCT decreases significantly after surgery () but no statistical differences were found in SCT (). Correlations between pre- and postsurgery were found for all tonometers used, with and for the air pulse tonometer, and for Perkins, and and for Diaton. Conclusion. Transpalpebral tonometry may be useful for measuring postsurgery IOP after myopic LASIK ablation because this technique is not influenced by the treatment.

Formato

application/pdf

Identificador

http://eprints.ucm.es/39209/1/JOPH2015-683895.pdf

Idioma(s)

en

Publicador

Hindawi Publishing Corporation

Relação

http://eprints.ucm.es/39209/

https://dx.doi.org/10.1155/2015/683895

DOI: 10.1155/2015/683895

SAF2013-44416-R

RD12/0034/0003

Direitos

cc_by

info:eu-repo/semantics/openAccess

Palavras-Chave #Cirugía #Oftalmología #Lentes de contacto
Tipo

info:eu-repo/semantics/article

PeerReviewed