975 resultados para Laboratory results


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is Part 3 of a study of creep and resilient modulus testing of hot mix asphalt concrete. The creep and resilient modulus testing in Part 1 showed the improved load carrying characteristics of crushed particles. Cores from pavements drilled in Part 2 exhibited a poor correlation with rutting and creep/resilient modulus on pavement with a range of rut depths. The objective of Part 3 was to determine the relationship of creep and resilient modulus for 1) Marshall specimens from laboratory mixing for mix design; 2) Marshall specimens from construction plant mixing; and 3) cores drilled from the hot mixed asphalt pavement. The creep and resilient modulus data from these three sources exhibited substantial variations. No meaningful correlations of the results from these three sources were obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spreading the PSF over a quite large amount of pixels is an increasingly used observing technique in order to reach extremely precise photometry, such as in the case of exoplanets searching and characterization via transits observations. A PSF top-hat profile helps to minimize the errors contribution due to the uncertainty on the knowledge of the detector flat field. This work has been carried out during the recent design study in the framework of the ESA small mission CHEOPS. Because of lack of perfect flat-fielding information, in the CHEOPS optics it is required to spread the light of a source into a well defined angular area, in a manner as uniform as possible. Furthermore this should be accomplished still retaining the features of a true focal plane onto the detector. In this way, for instance, the angular displacement on the focal plane is fully retained and in case of several stars in a field these look as separated as their distance is larger than the spreading size. An obvious way is to apply a defocus, while the presence of an intermediate pupil plane in the Back End Optics makes attractive to introduce here an optical device that is able to spread the light in a well defined manner, still retaining the direction of the chief ray hitting it. This can be accomplished through an holographic diffuser or through a lenslet array. Both techniques implement the concept of segmenting the pupil into several sub-zones where light is spread to a well defined angle. We present experimental results on how to deliver such PSF profile by mean of holographic diffuser and lenslet array. Both the devices are located in an intermediate pupil plane of a properly scaled laboratory setup mimicking the CHEOPS optical design configuration. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Evaluation of major feed resources was conducted in four crop-livestock mixed farming systems of central southern Ethiopia, with 90 farmers, selected using multi-stage purposive and random sampling methods. Discussions were held with focused groups and key informants for vernacular name identification of feed, followed by feed sampling to analyse chemical composition (CP, ADF and NDF), in-vitro dry matter digestibility (IVDMD), and correlate with indigenous technical knowledge (ITK). Native pastures, crop residues (CR) and multi-purpose trees (MPT) are the major feed resources, demonstrated great variations in seasonality, chemical composition and IVDMD. The average CP, NDF and IVDMD values for grasses were 83.8 (ranged: 62.9–190), 619 (ranged: 357–877) and 572 (ranged: 317–743) g kg^(−1) DM, respectively. Likewise, the average CP, NDF and IVDMD for CR were 58 (ranged: 20–90), 760 (ranged: 340–931) and 461 (ranged: 285–637)g kg^(−1) DM, respectively. Generally, the MPT and non-conventional feeds (NCF, Ensete ventricosum and Ipomoea batatas) possessed higher CP (ranged: 155–164 g kg^(−1) DM) and IVDMD values (611–657 g kg^(−1) DM) while lower NDF (331–387 g kg^(−1) DM) and ADF (321–344 g kg^(−1) DM) values. The MPT and NCF were ranked as the best nutritious feeds by ITK while crop residues were the least. This study indicates that there are remarkable variations within and among forage resources in terms of chemical composition. There were also complementarities between ITK and feed laboratory results, and thus the ITK need to be taken into consideration in evaluation of local feed resources.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper deals with the use of simplified methods to predict methane generation in tropical landfills. Methane recovery data obtained on site as part of a research program being carried Out at the Metropolitan Landfill, Salvador, Brazil, is analyzed and used to obtain field methane generation over time. Laboratory data from MSW samples of different ages are presented and discussed: and simplified procedures to estimate the methane generation potential, L(o), and the constant related to the biodegradation rate, k are applied. The first order decay method is used to fit field and laboratory results. It is demonstrated that despite the assumptions and the simplicity of the adopted laboratory procedures, the values L(o) and k obtained are very close to those measured in the field, thus making this kind of analysis very attractive for first approach purposes. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Human brucellosis is an occupational disease affecting workers in slaughterhouses, butcher shops and the milk and dairy product industry as well as individuals who work in clinical or research laboratories. We report the first outbreak of a Brucella abortus infection in a Brazilian laboratory and compare the data obtained with reports available in the literature. Exposure was a result of damage to a biological safety cabinet and failure of the unidirectional airflow ventilation system. An epidemiological investigation identified 3 seroconverted individuals, 1 of whom had clinical manifestations and laboratory results compatible with infection at the time of exposure (n=11; attack rate=9.1%).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Metarhizium anisopliae is one of the most studied agents of biological control of several arthropod plagues, including the cattle tick Rhipicephalus (Boophilus) microplus. Studies have been conducted to assess the fungal complex infection process towards its hosts. To accomplish that, mutant strains overexpressing or lacking assumed determinant genes for the process were constructed over the years. A fundamental experiment to demonstrate a particular gene or set of genes participation is the bioassay. The comparison of bioassays using wild and engineered strains is an essential tool to affirm a given gene is crucial in the process. Therefore, the in vitro bioassays should mimic the results obtained in tests under field conditions. In this study, tests under laboratory and filed conditions were done and a correlation analysis was performed in order to statistically validate in vitro bioassays. Tick egg laying, larvae hatching and host mortality were recorded in each experiment through 21 days, both under laboratory and field conditions. In all cases, M. anisopliae treatments were statistically different from the control treatments. A linear regression analysis was performed between the cases. Laboratory results showed a statistically significant correlation with the field conditions using the Pearson's Correlation Test (P < 0.01 host mortality - 0.969, tick egg laying - 0.977 and larvae hatching - 0.956). These results legitimize the in vitro bioassays and, therefore, constitute them as a valid tool for studying this fungus behavior, so they can be used to infer M. anisopliae response towards R. (Boophilus) microplus.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: The biorhythm of serum uric acid was evaluated in a large sample of a clinical laboratory database by spectral analysis and the influence of the gender and age on uric acid variability. Methods: Serum uric acid values were extracted from a large database of a clinical laboratory from May 2000 to August 2006. Outlier values were excluded from the analysis and the remaining data (n = 73,925) were grouped by gender and age ranges. Rhythm components were obtained by the Lomb Scargle method and Cosinor analysis. Results: Serum uric acid was higher in men than in women older than 13 years (p<0.05). Compared with 0-12 year group, uric acid increased in men but not in women older than 13 years (p<0.05). Circannual (12 months) and transyear (17 months) rhythm components were detected, but they were significant only in adult individuals (>26 years, p<0.05). Cosinor analysis showed that midline estimating statistic of rhythm (MESOR) values were higher in men (range: 353-368 mu mol/L) than in women (range: 240-278 mu mol/L; p<0.05), independent of the age and rhythm component. The extent of predictable change within a cycle, approximated by the double amplitude, represented up to 20% of the corresponding MESOR. Conclusions: Serum uric acid biorhythm is dependent on gender and age and it may have relevant influence on preanalytical variability of clinical laboratory results.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Abstract Background Identification of nontuberculous mycobacteria (NTM) based on phenotypic tests is time-consuming, labor-intensive, expensive and often provides erroneous or inconclusive results. In the molecular method referred to as PRA-hsp65, a fragment of the hsp65 gene is amplified by PCR and then analyzed by restriction digest; this rapid approach offers the promise of accurate, cost-effective species identification. The aim of this study was to determine whether species identification of NTM using PRA-hsp65 is sufficiently reliable to serve as the routine methodology in a reference laboratory. Results A total of 434 NTM isolates were obtained from 5019 cultures submitted to the Institute Adolpho Lutz, Sao Paulo Brazil, between January 2000 and January 2001. Species identification was performed for all isolates using conventional phenotypic methods and PRA-hsp65. For isolates for which these methods gave discordant results, definitive species identification was obtained by sequencing a 441 bp fragment of hsp65. Phenotypic evaluation and PRA-hsp65 were concordant for 321 (74%) isolates. These assignments were presumed to be correct. For the remaining 113 discordant isolates, definitive identification was based on sequencing a 441 bp fragment of hsp65. PRA-hsp65 identified 30 isolates with hsp65 alleles representing 13 previously unreported PRA-hsp65 patterns. Overall, species identification by PRA-hsp65 was significantly more accurate than by phenotype methods (392 (90.3%) vs. 338 (77.9%), respectively; p < .0001, Fisher's test). Among the 333 isolates representing the most common pathogenic species, PRA-hsp65 provided an incorrect result for only 1.2%. Conclusion PRA-hsp65 is a rapid and highly reliable method and deserves consideration by any clinical microbiology laboratory charged with performing species identification of NTM.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Follow-up of abnormal outpatient laboratory test results is a major patient safety concern. Electronic medical records can potentially address this concern through automated notification. We examined whether automated notifications of abnormal laboratory results (alerts) in an integrated electronic medical record resulted in timely follow-up actions. METHODS: We studied 4 alerts: hemoglobin A1c > or =15%, positive hepatitis C antibody, prostate-specific antigen > or =15 ng/mL, and thyroid-stimulating hormone > or =15 mIU/L. An alert tracking system determined whether the alert was acknowledged (ie, provider clicked on and opened the message) within 2 weeks of transmission; acknowledged alerts were considered read. Within 30 days of result transmission, record review and provider contact determined follow-up actions (eg, patient contact, treatment). Multivariable logistic regression models analyzed predictors for lack of timely follow-up. RESULTS: Between May and December 2008, 78,158 tests (hemoglobin A1c, hepatitis C antibody, thyroid-stimulating hormone, and prostate-specific antigen) were performed, of which 1163 (1.48%) were transmitted as alerts; 10.2% of these (119/1163) were unacknowledged. Timely follow-up was lacking in 79 (6.8%), and was statistically not different for acknowledged and unacknowledged alerts (6.4% vs 10.1%; P =.13). Of 1163 alerts, 202 (17.4%) arose from unnecessarily ordered (redundant) tests. Alerts for a new versus known diagnosis were more likely to lack timely follow-up (odds ratio 7.35; 95% confidence interval, 4.16-12.97), whereas alerts related to redundant tests were less likely to lack timely follow-up (odds ratio 0.24; 95% confidence interval, 0.07-0.84). CONCLUSIONS: Safety concerns related to timely patient follow-up remain despite automated notification of non-life-threatening abnormal laboratory results in the outpatient setting.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the association between quantitative ultrasonography at hand phalanges (QUS) and dual energy X-ray absorptiometry (DXA), and between these methods with food intake and history of bone fractures. SUBJECTS AND METHODS:After two years of follow up of 270 schoolchildren, 10 of them, who showed bone mass below - 2 SD in QUS, were included in the present study. Laboratory results and DXA data were analyzed. RESULTS: Bone mass evaluated by DXA at L1-L4 ranged from -2.8 to -1.1 SDS, and whole body bone mass, from -2.9 to -1.2 SDS. Three children had history of non-pathological bone fractures. Dietary assessment showed low intake of calcium in 10 cases, of phosphorus in 6, and of vitamin D in 8 cases. There were no differences among the cases of bone mass below-2 SD in any of the three used methods. There was no association between history of bone fractures and food intake, and between these evaluations and bone mass. CONCLUSION: In this small group of schoolchildren there was an association between the methods QUS and DXA. However, there was no association between bone mass and the history of bone fractures, or calcium, phosphorus and vitamin D intake.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: O objetivo deste estudo é descrever a metodologia da análise da rotação do joelho utilizando instrumentos do laboratório de biomecânica e apresentar os resultados preliminares de um estudo comparativo com pacientes submetidos à reconstrução do ligamento cruzado anterior com a técnica de duplo feixe. MÉTODOS: Descreveu-se o protocolo atualmente utilizado em nosso laboratório e realizou-se a análise cinemática tridimensional e medida da amplitude de rotação do joelho de oito pacientes normais (grupo controle) e 12 pacientes operados com a técnica de duplo feixe em três tarefas no laboratório de biomecânica. RESULTADOS: Não indicam diferenças significativas entre os lados operados e não operados em relação às amplitudes médias da marcha, da marcha com mudança de direção ou da marcha com mudança de direção ao descer a escada (p > 0,13). CONCLUSÕES: Os resultados preliminares não demonstraram diferença da técnica de reconstrução de LCA em duplo feixe em relação ao lado contralateral e ao grupo controle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hemoglobinopathies were included in the Brazilian Neonatal Screening Program on June 6, 2001. Automated high-performance liquid chromatography (HPLC) was indicated as one of the diagnostic methods. The amount of information generated by these systems is immense, and the behavior of groups cannot always be observed in individual analyses. Three-dimensional (3-D) visualization techniques can be applied to extract this information, for extracting patterns, trends or relations from the results stored in databases. We applied the 3-D visualization tool to analyze patterns in the results of hemoglobinopathy based on neonatal diagnosis by HPLC. The laboratory results of 2520 newborn analyses carried out in 2001 and 2002 were used. The ""Fast"", ""F1"", ""F"" and ""A"" peaks, which were detected by the analytical system, were chosen as attributes for mapping. To establish a behavior pattern, the results were classified into groups according to hemoglobin phenotype: normal (N = 2169), variant (N = 73) and thalassemia (N = 279). 3-D visualization was made with the FastMap DB tool; there were two distribution patterns in the normal group, due to variation in the amplitude of the values obtained by HPLC for the F1 window. It allowed separation of the samples with normal Hb from those with alpha thalassemia, based on a significant difference (P < 0.05) between the mean values of the ""Fast"" and ""A"" peaks, demonstrating the need for better evaluation of chromatograms; this method could be used to help diagnose alpha thalassemia in newborns.