999 resultados para LUMINOSITY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

(Morphological alterations in leave of micropropagated pineapple plants cv. IAC Gomo-de-mel acclimatizated in different conditions of luminosity). Microprapagated plants usually show difficulties to adapt to ex vitro conditions, and many times are submitted to the rustication process to aim the reduction of all the impacts resulting from the environmental changes. Once the leaf and its annexes are important indicators of adaptability strategies of the plants to adverse environmental conditions, the objective of this work was to compare the leaf anatomy of pineapple cv. IAC Gomo-de-mel in vitro cultivated plants with microplants acclimatized in different conditions of luminosity, under mesh, with 50% of shading and directly exposed to sunlight, to verify the needed of rustication process on this cultivar. Evaluations of the leaf epidermis using light and electronic scanning microscopy showed an increase on scale density in both leaves surfaces of the ex vitro microplants, mainly related to the ones directly exposed to sunlight. Subsequent observations showed an increase on cuticle thickness, on wavy contours of epidermal cells, and on the distribution and quantity of mesophyll fibers, evidencing the light conditions interference in morphological characteristics of these microplants. These alterations had not harmed microplant development, showing that are not need of rustication stages on the acclimatization process of this cultivar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new statistical parallax method using the Maximum Likelihood principle is presented, allowing the simultaneous determination of a luminosity calibration, kinematic characteristics and spatial distribution of a given sample. This method has been developed for the exploitation of the Hipparcos data and presents several improvements with respect to the previous ones: the effects of the selection of the sample, the observational errors, the galactic rotation and the interstellar absorption are taken into account as an intrinsic part of the formulation (as opposed to external corrections). Furthermore, the method is able to identify and characterize physically distinct groups in inhomogeneous samples, thus avoiding biases due to unidentified components. Moreover, the implementation used by the authors is based on the extensive use of numerical methods, so avoiding the need for simplification of the equations and thus the bias they could introduce. Several examples of application using simulated samples are presented, to be followed by applications to real samples in forthcoming articles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absolute K magnitudes and kinematic parameters of about 350 oxygen-rich Long-Period Variable stars are calibrated, by means of an up-to-date maximum-likelihood method, using HIPPARCOS parallaxes and proper motions together with radial velocities and, as additional data, periods and V-K colour indices. Four groups, differing by their kinematics and mean magnitudes, are found. For each of them, we also obtain the distributions of magnitude, period and de-reddened colour of the base population, as well as de-biased period-luminosity-colour relations and their two-dimensional projections. The SRa semiregulars do not seem to constitute a separate class of LPVs. The SRb appear to belong to two populations of different ages. In a PL diagram, they constitute two evolutionary sequences towards the Mira stage. The Miras of the disk appear to pulsate on a lower-order mode. The slopes of their de-biased PL and PC relations are found to be very different from the ones of the Oxygen Miras of the LMC. This suggests that a significant number of so-called Miras of the LMC are misclassified. This also suggests that the Miras of the LMC do not constitute a homogeneous group, but include a significant proportion of metal-deficient stars, suggesting a relatively smooth star formation history. As a consequence, one may not trivially transpose the LMC period-luminosity relation from one galaxy to the other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En opération depuis 2008, l’expérience ATLAS est la plus grande de toutes les expériences au LHC. Les détecteurs ATLAS- MPX (MPX) installés dans ATLAS sont basés sur le détecteur au silicium à pixels Medipix2 qui a été développé par la collaboration Medipix au CERN pour faire de l’imagerie en temps réel. Les détecteurs MPX peuvent être utilisés pour mesurer la luminosité. Ils ont été installés à seize différents endroits dans les zones expérimentale et technique d’ATLAS en 2008. Le réseau MPX a recueilli avec succès des données indépendamment de la chaîne d’enregistrement des données ATLAS de 2008 à 2013. Chaque détecteur MPX fournit des mesures de la luminosité intégrée du LHC. Ce mémoire décrit la méthode d’étalonnage de la luminosité absolue mesurée avec les détectors MPX et la performance des détecteurs MPX pour les données de luminosité en 2012. Une constante d’étalonnage de la luminosité a été déterminée. L’étalonnage est basé sur technique de van der Meer (vdM). Cette technique permet la mesure de la taille des deux faisceaux en recouvrement dans le plan vertical et horizontal au point d’interaction d’ATLAS (IP1). La détermination de la luminosité absolue nécessite la connaissance précise de l’intensité des faisceaux et du nombre de trains de particules. Les trois balayages d’étalonnage ont été analysés et les résultats obtenus par les détecteurs MPX ont été comparés aux autres détecteurs d’ATLAS dédiés spécifiquement à la mesure de la luminosité. La luminosité obtenue à partir des balayages vdM a été comparée à la luminosité des collisions proton- proton avant et après les balayages vdM. Le réseau des détecteurs MPX donne des informations fiables pour la détermination de la luminosité de l’expérience ATLAS sur un large intervalle (luminosité de 5 × 10^29 cm−2 s−1 jusqu’à 7 × 10^33 cm−2 s−1 .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After completion of the LHC8 run in 2012, the plan is to upgrade the LHC for operation close to its design energy root s = 14 TeV, with a goal of collecting hundreds of fb(-1) of integrated luminosity. The time is propitious to begin thinking of what is gained by even further LHC upgrades. In this report, we compute an LHC14 reach for supersymmetry in the mSUGRA/CMSSM model with an anticipated high luminosity upgrade. We find that LHC14 with 300 (3000) fb(-1) has a reach for supersymmetry via gluino/squark searches of m((g) over tilde) similar to 3.2 TeV (3.6 TeV) for m((q) over tilde) similar to m((g) over tilde), and a reach of m((g) over tilde) similar to 1.8 TeV (2.3 TeV) for m((q) over tilde) >> m((g) over tilde). In the case where m((q) over tilde) >> m((g) over tilde), then the LHC14 reach for chargino-neutralino production with decay into the Wh + 6 is not an element of(T) final state reaches to m((g) over tilde) similar to 2.6 TeV for 3000 fb(-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyse the dependence of the luminosity function (LF) of galaxies in groups on group dynamical state. We use the Gaussianity of the velocity distribution of galaxy members as a measurement of the dynamical equilibrium of groups identified in the Sloan Digital Sky Survey Data Release 7 by Zandivarez & Martinez. We apply the Anderson-Darling goodness-of-fit test to distinguish between groups according to whether they have Gaussian or non-Gaussian velocity distributions, i.e. whether they are relaxed or not. For these two subsamples, we compute the (0.1)r-band LF as a function of group virial mass and group total luminosity. For massive groups, , we find statistically significant differences between the LF of the two subsamples: the LFs of groups that have Gaussian velocity distributions have a brighter characteristic absolute magnitude (similar to 0.3 mag) and a steeper faint-end slope (similar to 0.25). We detect a similar effect when comparing the LF of bright [M-0.1r(group) - 5log(h) < -23.5] Gaussian and non-Gaussian groups. Our results indicate that, for massive/luminous groups, the dynamical state of the system is directly related to the luminosity of its galaxy members.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La misura della luminosità è un obiettivo importante per tutta la fisica del modello standard e per la scoperta di nuova fisica, poiché è legata alla sezione d'urto (σ) e al rate di produzione (R) di un determinato processo dalla relazione L = R*σ. Nell'eserimento ATLAS a LHC è installato un monitor di luminosità dedicato chiamato LUCID (Luminosity measurements Using Cherenkov Integrating Detector). Grazie ai dati acquisiti durante il 2010 la valutazione off-line delle performances del LUCID e l'implementazione di controlli on-line sulla qualità dei dati raccolti è stata possibile. I dati reali sono stati confrontati con i dati Monte Carlo e le simulazioni sono state opportunamente aggiustate per ottimizzare l'accordo tra i due. La calibrazione della luminosità relativa che permette di ottenere una valutazione della luminosità assoluta è stata possibile grazie ai cosiddetti Van der Meer scan, grazie ai quale è stata ottenuta una precisione dell'11%. L'analisi della fisica del decadimento della Z è in tuttora in corso per ottenere tramite il rate a cui avviene il processo una normalizzazione della luminosità con una precisione migliore del 5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In questo elaborato abbiamo analizzato un campione di 22 galssie early-type. Utilizzando una tecnica di cross-correlazione, abbiamo ottenuto profili radiali di rotazione e di dis- persione di velocitá. Questi dati ci hanno permesso di investigare molte delle proprietá dinamiche delle nostre galassie. Abbiamo ottenuto indizi sull’anisotropia orbitale e stimato le masse e il rapporto M/L del campione. Le masse misurate variano da 1010 a 1012 M , mentre i valori degli M/L, per cui abbiamo trovato una dipendenza del tipo Log M/L ∝ 0.28 Log L , sono dell’ordine dell’unitá. Abbiamo anche riprodotto le famose relazioni di scala e abbi- amo utlizzato un set di dati sugli indici di Lick/IDS per ricercare relazioni tra le proprietá chimiche e quelle dinamiche. In particolare, abbiamo riscontrato una correlazione tra molti degli indici dipendenti dalla metallicitá e la profonditá della buca di potenziale. Tali indici sembrano correlare anche con il M/L. La rotazione e la forma del profilo di dispersione di velocitá sembrano essere ininfluenti sulle proprietá chimiche. In ultima analisi, abbiamo considerato le implicazioni delle nostre misure riguardo la natura della popolazione stellare e dell’emissione X delle nostre galassie. L’indice di colore e il M/L sembrano indicare che la popolazione stellare delle nostre galassie é dominata da stelle appartenenti alle classi spettrali late-G e early-K. Sembra inoltre esserci una correlazione tra l’emissione X degli elementi del nostro campione e la profonditá della loro buca di potenziale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La sezione d’urto totale adronica gioca un ruolo fondamentale nel programma di fisica di LHC. Un calcolo di questo parametro, fondamentale nell’ambito della teoria delle interazioni forti, non é possibile a causa dell’inapplicabilità dell’approccio perturbativo. Nonostante ciò, la sezione d’urto può essere stimata, o quanto meno le può essere dato un limite, grazie ad un certo numero di relazioni, come ad esempio il Teorema Ottico. In questo contesto, il detector ALFA (An Absolute Luminosity For ATLAS) sfrutta il Teorema Ottico per determinare la sezione d’urto totale misurando il rate di eventi elastici nella direzione forward. Un tale approccio richiede un metodo accurato di misura della luminosità in condizioni sperimentali difficoltose, caratterizzate da valori di luminosità istantanea inferiore fino a 7 ordini di grandezza rispetto alle normali condizioni di LHC. Lo scopo di questa tesi è la determinazione della luminosità integrata di due run ad alto β*, utilizzando diversi algoritmi di tipo Event-Counting dei detector BCM e LUCID. Particolare attenzione è stata riservata alla sottrazione del fondo e allo studio delle in- certezze sistematiche. I valori di luminosità integrata ottenuti sono L = 498.55 ± 0.31 (stat) ± 16.23 (sys) μb^(-1) and L = 21.93 ± 0.07 (stat) ± 0.79 (sys) μb^(-1), rispettivamente per i due run. Tali saranno forniti alla comunità di fisica che si occupa della misura delle sezioni d’urto protone-protone, elastica e totale. Nel Run II di LHC, la sezione d’urto totale protone-protone sarà stimata con un’energia nel centro di massa di 13 TeV per capire meglio la sua dipendenza dall’energia in un simile regime. Gli strumenti utilizzati e l’esperienza acquisita in questa tesi saranno fondamentali per questo scopo.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The luminosity calibration for the ATLAS detector at the LHC during pp collisions at root s = 7 TeV in 2010 and 2011 is presented. Evaluation of the luminosity scale is performed using several luminosity-sensitive detectors, and comparisons are made of the long-term stability and accuracy of this calibration applied to the pp collisions at root s = 7 TeV. A luminosity uncertainty of delta L/L = +/- 3.5 % is obtained for the 47 pb(-1) of data delivered to ATLAS in 2010, and an uncertainty of delta L/L = +/- 1.8 % is obtained for the 5.5 fb(-1) delivered in 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Specific tests to assess reliability of high luminosity AlInGaP LED for outdoor applications are needed. In this paper tests to propose a model involving three parameters: temperature, humidity and current have been carried out. Temperature, humidity and current accelerated model has been proposed to evaluate the reliability of this type of LED. Degradation and catastrophic failure mechanisms have been analyzed. Finally we analyze the effect of serial resistance in power luminosity degradation.