971 resultados para LONG-BONE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The AO comprehensive pediatric longbone fracture classification system describes the localization and morphology of fractures, and considers severity in 3 categories: (1) simple, (2) wedge, and (3) complex. We evaluated the reliability and accuracy of surgeons in using this rating system. MATERIAL AND METHODS: In a first validation phase, 5 experienced pediatric (orthopedic) surgeons reviewed radiographs of 267 prospectively collected pediatric fractures (agreement study A). In a second study (B), 70 surgeons of various levels of experience in 15 clinics classified 275 fractures via internet. Simple fractures comprised about 90%, 99% and 100% of diaphyseal (D), metaphyseal (M), and epiphyseal (E) fractures, respectively. RESULTS: Kappa coefficients for severity coding in D fractures were 0.82 and 0.51 in studies A and B, respectively. The median accuracy of surgeons in classifying simple fractures was above 97% in both studies but was lower, 85% (46-100), for wedge or complex D fractures. INTERPRETATION: While reliability and accuracy estimates were satisfactory as a whole, the ratings of some individual surgeons were inadequate. Our findings suggest that the classification of fracture severity in children should be done in only two categories that distinguish between simple and wedge/complex fractures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first AO comprehensive pediatric long-bone fracture classification system has been proposed following a structured path of development and validation with experienced pediatric surgeons. A Web-based multicenter agreement study involving 70 surgeons in 15 clinics and 5 countries was conducted to assess the reliability and accuracy of this classification when used by a wide range of surgeons with various levels of experience. Training was provided at each clinic before the session. Using the Internet, participants could log in at any time and classify 275 supracondylar, radius, and tibia fractures at their own pace. The fracture diagnosis was made following the hierarchy of the classification system using both clinical terminology and codes. kappa coefficients for the single-surgeon diagnosis of epiphyseal, metaphyseal, or diaphyseal fracture type were 0.66, 0.80, and 0.91, respectively. Median accuracy estimates for each bone and type were all greater than 80%. Depending on their experience and specialization, surgeons greatly varied in their ability to classify fractures. Pediatric training and at least 2 years of experience were associated with significant improvement in reliability and accuracy. Kappa coefficients for diagnosis of specific child patterns were 0.51, 0.63, and 0.48 for epiphyseal, metaphyseal, and diaphyseal fractures, respectively. Identified reasons for coding discrepancies were related to different understandings of terminology and definitions, as well as poor quality radiographic images. Results supported some minor adjustments in the coding of fracture type and child patterns. This classification system received wide acceptance and support among the surgeons involved. As long as appropriate training could be performed, the system classification was reliable, especially among surgeons with a minimum of 2 years of clinical experience. We encourage broad-based consultation between surgeons' international societies and the use of this classification system in the context of clinical practice as well as prospectively for clinical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Children and adolescents are at high risk of sustaining fractures during growth. Therefore, epidemiological assessment is crucial for fracture prevention. The AO Comprehensive Injury Automatic Classifier (AO COIAC) was used to evaluate epidemiological data of pediatric long bone fractures in a large cohort. METHODS: Data from children and adolescents with long bone fractures sustained between 2009 and 2011, treated at either of two tertiary pediatric surgery hospitals in Switzerland, were retrospectively collected. Fractures were classified according to the AO Pediatric Comprehensive Classification of Long Bone Fractures (PCCF). RESULTS: For a total of 2716 patients (60% boys), 2807 accidents with 2840 long bone fractures (59% radius/ulna; 21% humerus; 15% tibia/fibula; 5% femur) were documented. Children's mean age (SD) was 8.2 (4.0) years (6% infants; 26% preschool children; 40% school children; 28% adolescents). Adolescent boys sustained more fractures than girls (p < 0.001). The leading cause of fractures was falls (27%), followed by accidents occurring during leisure activities (25%), at home (14%), on playgrounds (11%), and traffic (11%) and school accidents (8%). There was boy predominance for all accident types except for playground and at home accidents. The distribution of accident types differed according to age classes (p < 0.001). Twenty-six percent of patients were classed as overweight or obese - higher than data published by the WHO for the corresponding ages - with a higher proportion of overweight and obese boys than in the Swiss population (p < 0.0001). CONCLUSION: Overall, differences in the fracture distribution were sex and age related. Overweight and obese patients seemed to be at increased risk of sustaining fractures. Our data give valuable input into future development of prevention strategies. The AO PCCF proved to be useful in epidemiological reporting and analysis of pediatric long bone fractures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. This investigation was carried out to study the influence of early quantitative food restriction (40% of ad libitum intake from 7 to 14 d of age) and environmental rearing temperature (thermoneutral, cold and hot) on long bone (tibia, femur and humerus) development in broiler chickens.2. Tibia, femur and humerus were obtained at the ages of 14, 21, 28, 35 and 42 d; and the variables studied were: length and width (mm, expressed as absolute values), bone breaking strength (kgf) and bone weight/bone length index (BW/BL, mg/mm).3. All bone variables increased with bird age. Food restriction reduced bone length and width but did not affect bone weight. High environmental rearing temperature reduced bone length and width at 42 d of age. Bone strength was not affected by environmental temperature but the calculated BW/BL index was reduced by heat exposure.4. The findings suggest that food restriction and high environmental rearing temperature reduce long bone growth; bone breaking strength was affected by bird age but not by food restriction nor rearing ambient temperature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This investigation was carried out to study the influence of early qualitative feed restriction and environmental rearing temperature on long bone development in broiler. Energy and protein restriction reduced femur width and humerus weight, but did not affect tibia parameters. Broilers kept at cold environmental temperature showed reduced femur, tibia and humerus length and tibia weight, but the calculated density was not affected by rearing temperature. These findings suggest that qualitative feed restriction and environmental temperature influenced the normal long bone growth; however, bone weight/bone length index (calculated density) was not affected by rearing temperature. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Brazilian orthopaedic company designed a stainless steel plate called Synthesis Pengo System (S.P.S.), which has one fixed and one changeable extremity. According to the assembly of the changeable extremity, it is possible to obtain dynamization or neutralization of the fracture site. Since the S.P.S. plate was developed for use in human patients, the aim of this study was to evaluate this system in long-bone diaphyseal fractures in dogs. Eight dogs with closed diaphyseal fractures of the femur (n = 1), radius and ulna (n = 5), and tibia (n = 2) were used. Patients were aged seven months to three years and weighed 18 to 31.2 kg. The S.P.S. plate was assembled with one fixed extremity and one changeable extremity in dynamization mode. The trail bar was positioned for synthesis modules with holes for cortical screws. The modules were positioned close to one another in two fractures and for away from the fracture site in the others. The bone healing occurred by external callus. Since motion at the fracture site determines the amount of callus required, the secondary bone healing that was observed in all of the cases indicated less rigid fixation of this system. A potential benefit of this system was a lesser interface contact with the bone since it was only done by trail bar. The major disadvantage was the prominence of the implant. It was possible to conclude that the S.P.S. plate appears to be a suitable method for the treatment of diaphyseal fractures in dogs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to develop a child-specific classification system for long bone fractures and to examine its reliability and validity on the basis of a prospective multicentre study. METHODS: Using the sequentially developed classification system, three samples of between 30 and 185 paediatric limb fractures from a pool of 2308 fractures documented in two multicenter studies were analysed in a blinded fashion by eight orthopaedic surgeons, on a total of 5 occasions. Intra- and interobserver reliability and accuracy were calculated. RESULTS: The reliability improved with successive simplification of the classification. The final version resulted in an overall interobserver agreement of κ = 0.71 with no significant difference between experienced and less experienced raters. CONCLUSIONS: In conclusion, the evaluation of the newly proposed classification system resulted in a reliable and routinely applicable system, for which training in its proper use may further improve the reliability. It can be recommended as a useful tool for clinical practice and offers the option for developing treatment recommendations and outcome predictions in the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To report clinical evaluation of the clamp rod internal fixator 4.5/5.5 (CRIF 4.5/5.5) in bovine long-bone fracture repair. STUDY DESIGN: Retrospective study. ANIMALS: Cattle (n=22) with long-bone fractures. METHODS: Records for cattle with long-bone fractures repaired between 1999 and 2004 with CRIF 4.5/5.5 were reviewed. Quality of fracture repair, fracture healing, and clinical outcome were investigated by means of clinical examination, medical records, radiographs, and telephone questionnaire. RESULTS: Successful long-term outcome was achieved in 18 cattle (82%); 4 were euthanatized 2-14 days postoperatively because of fracture breakdowns. Two cattle had movement of clamps on the rod. Moderate to severe callus formation was evident in 11 cattle 6 months postoperatively. CONCLUSIONS: Movement of clamps on the rod was recognized as implant failure unique to the CRIF. This occurred in cattle with poor fracture stability because of an extensive cortical defect. The CRIF system may not be ideal to treat metacarpal/metatarsal fractures because its voluminous size makes skin closure difficult, thereby increasing the risk of postoperative infections. CLINICAL RELEVANCE: CRIF cannot be recommended for repair of complicated long-bone fractures in cattle.