994 resultados para Jaw Fixation Techniques


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR) is the most common, allowing a great range of movements and stable internal fixation (SIF), therefore eliminating the need of maxillomandibular block in the postoperative period. Objectives: The purpose of this study was to evaluate the biomechanical resistance of three national systems used for SIF in SOMR in sheep mandibles. Material and methods: The study was performed in 30 sheep hemi-mandibles randomly divided into 3 experimental groups, each containing 10 hemi-mandibles. The samples were measured to avoid discrepancies and then subjected to SOMR with 5-mm advancement. In group I, 2.0x12 mm screws were used for fixation, inserted in an inverted "L" pattern (inverted "L" group). In group II, fixation was performed with two 2.0x12 mm screws, positioned in a linear pattern and a 4-hole straight miniplate and four 2.0x6.0 mm monocortical screws (hybrid group). In group III, fixation was performed with two-hole straight miniplates and eight 2.0x6.0 mm monocortical screws (mini plate group). All materials used for SIF were supplied by Osteosin - SIN. The hemimandibles were subjected to vertical linear load test by Kratos K2000MP mechanical testing unit for loading registration and displacement. Results: All groups showed similar resistance during mechanical test for loading and displacement, with no statistically significant differences between groups according to analysis of variance. Conclusion: These results indicate that the three techniques of fixation are equally effective for clinical fixation of SOMR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent studies have evaluated many methods of internal fixation for sagittal split ramus osteotomy (SSRO), aiming to increase stability of the bone segments while minimizing condylar displacement. The purpose of this study was to evaluate, through biomechanical testing, the stability of the fixation comparing a specially designed bone plate to other two commonly used methods. Thirty hemimandibles were separated into three equal groups. All specimens received SSRO. In Group I the osteotomies were fixed with three 15 mm bicortical positional screws in an inverted-L pattern with an insertion angle of 90°. In Group II, fixation was carried out with a four-hole straight plate and four 6 mm monocortical screws. In Group III, fixation was performed with an adjustable sagittal plate and eight 6 mm monocortical screws. Hemimandibles were submitted to vertical compressive loads, by a mechanical testing unit. Averages and standard deviations were submitted to analysis of variance using the Tukey test with a 5% level of significance. Bicortical screws presented the greatest values of loading resistance. The adjustable miniplate demonstrated 60% lower resistance compared to bicortical screws. Group II presented on average 40% less resistant to the axial loading. © 2012 International Association of Oral and Maxillofacial Surgeons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to perform a physicochemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures. Twenty-eight polyurethane mandibles were uniformly sectioned on the left angle. These were divided into 4 groups: group Eng 1P, one 2.0-mm plate and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates, the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the Ti-15Mo alloy. Each group was subjected to linear vertical loading at the first molar on the plated side in a mechanical testing unit. Means and standard deviations were compared with respect to statistical significance using ANOVA. The chemical composition of the Ti-15Mo alloy was close to the nominal value. The mapping of Mo and Ti showed a homogeneous distribution. SEM of the screw revealed machining debris. For the plates, only the cpTi plate undergoes a surface treatment. The metallographic analysis reveals granular microstructure, from the thermomechanical trials. A statistically significant difference was found (P < 0.05) when the comparison between both internal fixation techniques was performed. The 2P technique showed better mechanical behavior than 1P.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR) is the most common, allowing a great range of movements and stable internal fixation (SIF), therefore eliminating the need of maxillomandibular block in the postoperative period. Objectives: The purpose of this study was to evaluate the biomechanical resistance of three national systems used for SIF in SOMR in sheep mandibles. Material and methods: The study was performed in 30 sheep hemi-mandibles randomly divided into 3 experimental groups, each containing 10 hemi-mandibles. The samples were measured to avoid discrepancies and then subjected to SOMR with 5-mm advancement. In group I, 2.0x12 mm screws were used for fixation, inserted in an inverted "L" pattern (inverted "L" group). In group II, fixation was performed with two 2.0x12 mm screws, positioned in a linear pattern and a 4-hole straight miniplate and four 2.0x6.0 mm monocortical screws (hybrid group). In group III, fixation was performed with two-hole straight miniplates and eight 2.0x6.0 mm monocortical screws (mini plate group). All materials used for SIF were supplied by Osteosin - SIN. The hemimandibles were subjected to vertical linear load test by Kratos K2000MP mechanical testing unit for loading registration and displacement. Results: All groups showed similar resistance during mechanical test for loading and displacement, with no statistically significant differences between groups according to analysis of variance. Conclusion: These results indicate that the three techniques of fixation are equally effective for clinical fixation of SOMR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Trying to provide more anatomical data to the oral and maxillofacial surgeons regarding to orthognathic surgery, specifically about sagittal split osteotomy, the authors accomplished an anatomical study in dry human jaws, measuring the thickness in four previously established points of the body and mandibular ramus, at the usual spots used for the internal fixation by screws. Material and Methods: The authors also use the data collected to evaluate if there are significant differences between the group I (human dry mandibles with teeth) and group II (edentulous human dry mandibles). Results: For the group I the authors found the following results: x1 = 14,48, x2 = 14,94, x3=12,82 and x4 = 9,41, being the x2 the thickest point, and the least thick the x4. However in the group II, the found medium values were: x1 = 13,38, x2 = 13,08, x3 = 11,63 and x4 = 12,18, being the thickest point in that group the x1 and the least thick x3. The coefficient of simple correlation between the variables (group I and II) revealed a value of 0,6194, being this difference no significant at the meaning level of 95%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The objective of this study was to carry out a comparative evaluation of the mechanical resistance of 2 rigid internal fixation techniques for fractures of the mandibular condyle using miniplates.Materials and Methods: Fort), polyurethane resin replicas of human hemimandibles were used. The hemimandibles were sectioned to simulate a high subcondylar fracture and then stabilized with 2 fixing techniques using 2.0-mm system plates and screws. The fixation techniques were 2 separate 4-hole plates with 8 screws, and 2 overlaid 4-hole plates with 4 screws. Each system was submitted to load tests, with the application of the load in mediolateral and anteroposterior directions in an Instron 4411 universal assay machine (Instron, Norwood, MA).Results: Load values and peak displacement were measured. Means and standard deviations were evaluated by analysis of variance (P < .05) and Tukey tests, in which it was verified that the anteroposterior peak load value was affected by the arrangement of the plates on the models, although no differences were observed between the groups for the mediolateral peak load. The arrangement of the plates did not have any influence on peak displacement. Similarly, the final value of the mediolateral load was not affected by the arrangement of the plates on the model.Conclusion: The experimental model with 2 separate plates was statistically superior to the model with 2 overlaid plates only in relation to anteroposterior peak load. Despite showing superiority in mediolateral peak load and peak displacement, there was no statistical difference between the groups for these parameters. (C) 2009 American Association of Oral and Maxillofacial Surgeons

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate fixation properties of a new intervertebral anchored fusion device and compare these with ventral locking plate fixation. STUDY DESIGN: In vitro biomechanical evaluation. ANIMALS: Cadaveric canine C4-C7 cervical spines (n = 9). METHODS: Cervical spines were nondestructively loaded with pure moments in a nonconstraining testing apparatus to induce flexion/extension while angular motion was measured. Range of motion (ROM) and neutral zone (NZ) were calculated for (1) intact specimens, (2) specimens after discectomy and fixation with a purpose-built intervertebral fusion cage with integrated ventral fixation, and (3) after removal of the device and fixation with a ventral locking plate. RESULTS: Both fixation techniques resulted in a decrease in ROM and NZ (P < .001) compared with the intact segments. There were no significant differences between the anchored spacer and locking plate fixation. CONCLUSION: An anchored spacer appears to provide similar biomechanical stability to that of locking plate fixation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Small animal fracture models have gained increasing interest in fracture healing studies. To achieve standardized and defined study conditions, various variables must be carefully controlled when designing fracture healing experiments in mice or rats. The strain, age and sex of the animals may influence the process of fracture healing. Furthermore, the choice of the fracture fixation technique depends on the questions addressed, whereby intra- and extramedullary implants as well as open and closed surgical approaches may be considered. During the last few years, a variety of different, highly sophisticated implants for fracture fixation in small animals have been developed. Rigid fixation with locking plates or external fixators results in predominantly intramembranous healing in both mice and rats. Locking plates, external fixators, intramedullary screws, the locking nail and the pin-clip device allow different degrees of stability resulting in various amounts of endochondral and intramembranous healing. The use of common pins that do not provide rotational and axial stability during fracture stabilization should be discouraged in the future. Analyses should include at least biomechanical and histological evaluations, even if the focus of the study is directed towards the elucidation of molecular mechanisms of fracture healing using the largely available spectrum of antibodies and gene-targeted animals to study molecular mechanisms of fracture healing. This review discusses distinct requirements for the experimental setups as well as the advantages and pitfalls of the different fixation techniques in rats and mice.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Anterior cruciate ligament (ACL) tear is a common sports injury of the knee. Arthroscopic reconstruction using autogenous graft material is widely used for patients with ACL instability. The grafts most commonly used are the patellar and the hamstring tendons, by various fixation techniques. Although clinical evaluation and conventional radiography are routinely used in follow-up after ACL surgery, magnetic resonance imaging (MRI) plays an important role in the diagnosis of complications after ACL surgery. The aim of this thesis was to study the clinical outcome of patellar and hamstring tendon ACL reconstruction techniques. In addition, the postoperative appearance of the ACL graft was evaluated using several MRI sequences. Of the 175 patients who underwent an arthroscopically assisted ACL reconstruction, 99 patients were randomized into patellar tendon (n=51) or hamstring tendon (n=48) groups. In addition, 62 patients with hamstring graft ACL reconstruction were randomized into either cross-pin (n=31) or interference screw (n=31) fixation groups. Follow-up evaluation determined knee laxity, isokinetic muscle performance and several knee scores. Lateral and anteroposterior view radiographs were obtained. Several MRI sequences were obtained with a 1.5-T imager. The appearance and enhancement pattern of the graft and periligamentous tissue, and the location of bone tunnels were evaluated. After MRI, arthroscopy was performed on 14 symptomatic knees. The results revealed no significant differences in the 2-year outcome between the groups. In the hamstring tendon group, the average femoral and tibial bone tunnel diameter increased during 2 years follow-up by 33% and 23%, respectively. In the asymptomatic knees, the graft showed homogeneous and low signal intensity with periligamentous streaks of intermediate signal intensity on T2-weighted MR images. In the symptomatic knees, arthroscopy revealed 12 abnormal grafts and two meniscal tears, each with an intact graft. Among 3 lax grafts visible on arthroscopy, MRI showed an intact graft and improper bone tunnel placement. For diagnosing graft failure, all MRI findings combined gave a specificity of 90% and a sensitivity of 81%. In conclusion, all techniques appeared to improve patients' performance, and were therefore considered as good choices for ACL reconstruction. In follow-up, MRI permits direct evaluation of the ACL graft, the bone tunnels, and additional disorders of the knee. Bone tunnel enlargement and periligamentous tissue showing contrast enhancement were non-specific MRI findings that did not signify ACL deficiency. With an intact graft and optimal femoral bone tunnel placement, graft deficiency is unlikely, and the MRI examination should be carefully scrutinized for possible other causes for the patients symptoms.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fractures and arthritic joint destruction are common in the hand. A reliable and stable fracture fixation can be achieved by metal implants, which however, become unnecessary or even harmful after consolidation. The silicone implant arthroplasty is the current method of choice for reconstruction of metacarpophalangeal joints in rheumatoid patients. However, the outcome tends to worsen with long-term follow-up and implant-related complications become frequent. To address these problems, bioabsorbable implants were designed for the hand area. Aims of the studies were: 1) to evaluate the biomechanical stabilities provided by self- reinforced (SR) bioabsorbable implants in a transverse and an oblique osteotomy of small tubular bones and to compare them with those provided by metal implants; 2) to evaluate the SR poly-L/DL-lactide 70/30 plate for osteosynthesis in a proof-of-principle type of experiment in three cases of hand injuries; and 3) to evaluate the poly-L/D-lactide (PLA) 96/4 joint scaffold, a composite joint implant with a supplementary intramedullary Polyactive® stem and Swanson silicone implant in an experimental small joint arthroplasty model. Methods used were: 1) 112 fresh frozen human cadaver and 160 pig metacarpal bones osteotomised transversally or obliquely, respectively, and tested ex vivo in three point bending and in torsion; 2) three patient cases of complex hand injuries; and 3) the fifth metacarpophalangeal joints reconstructed in 18 skeletally-mature minipigs and studied radiologically and histologically. The initial fixation stabilities provided by bioabsorbable implants in the tubular bones of the hand were comparable with currently-employed metal fixation techniques, and were sufficient for fracture stabilisation in three preliminary cases in the hand. However, in torsion the stabilities provided by bioabsorbable implants were lower than that provided by metal counterparts. The bioabsorbable plate enhanced the bending stability for the bioabsorbable fixation construct. PLA 96/4 joint scaffolds demonstrated good biocompatibility and enabled fibrous tissue in-growth in situ. After scaffold degradation, a functional, stable pseudarthrosis with dense fibrous connective tissue was formed. However, the supplementary Polyactive® stem caused a deleterious tissue reaction and therefore the stem can not be applied to the composite joint implant. The bioabsorbable implants have potential for use in clinical hand surgery, but have to await validation in clinical patient series and controlled trials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The treatment of mandibular fractures has undergone many changes, especially after the introduction of rigid internal fixation techniques. Currently, the use of resorbable materials presents some advantages over metallic devices, particularly when applied in children. Objective: The authors discuss the controversies involved in the treatment of mandibular fractures in children, mainly related to fixation of fractures. Case Report: In this paper, we present a case of a 5 years treatment patient with mandibular angle fracture treated by open reduction and internal fixation with plates and screws. Final Comments: Aiming to not interfere in the development of tooth germs and mandibular bone growth a second surgery for removal of the fixation devices is indicated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The modalities of treatment with prostheses over implants for total edentulous patients can be divided in fixed and removable prostheses (overdentures). The fixed prostheses modality has proven to offer better results as to the functional aspects and, results in higher longevity. Overdentures are considered as a modality of rehabilitation utilized to compensate the need for better retention, aside from augmenting chewing efficiency. Its use is justified by its facilitated hygiene, reduced surgical and prosthetic costs, reestablishment of labial support and elimination of the possibility of air escape. However, this option presents psychosocial downside, since the fact that it is considered a removable rehabilitation modality does not please the majority of patients. Although many patients prefer a fixed implant-supported prosthesis to a removable overdenture, frequently it is necessary to utilize an implant retained overdenture as an alternative to the treatment, due to anatomical, physiological, aesthetic, hygienic, and financial limitations regarding the patient. The objective of this study was to discuss a clinical case of a partially edentulous patient treated in the Implantodontic Surgery Post-Graduation Course from the Kenedy Dentistry Institute Mozarteum/Famosp Unit – Goiânia-Brazil), and submitted to osseointegrated implants surgical fixation techniques. A modality of differential diagnosis was established after osseointegration period, it aimed at facilitating the choice of a rehabilitation model that could favor the patient’s and professional`s expectations. Therefore the appreciated aspects were function, comfort, aesthetics, and especially the patient satisfaction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: This investigation describes experimental tests of the biomechanical features of a new resorbable bone adhesive based on methacrylate-terminated oligolactides enhanced with osteoconductive β-tricalcium phosphate. Material and Methods: 51 New Zealand white rabbits were randomised to an adhesive group (n = 29) and a control group (n = 22). An extra-articular bone cylinder was taken from the proximal tibia, two stripes of adhesive were applied and the cylinders were replanted. After 10 and 21 days, 3 and 12 months tibial specimens were harvested and the cylinder pull-out test was performed with a servo-hydraulic machine. Additionally the pull-out force was evaluated with the bone-equivalent Ebazell® after 5, 10 and 360 minutes in 14 specimens each. Results: Average pull-out forces in the adhesive group were 28 N after 10 days (control: 57 N), 155 N after 21 days (216 N), 184 N after 3 months (197 N) and 205 N after 12 months (185 N). Investigations with Ebazell® showed almost identical pull-out forces after 5 min, 15 min and 360 min. Adhesive forces were as high as 125 N/cm2 of adhesive surface and more than 1200 N/g of adhesive mass. Conclusions: The adhesive investigated here has a very good primary adhesive power, compared to the literature data, achieved after only 5 minutes. Even in moist surroundings the adhesive capacity remains sufficient. The adhesive has to prove its resorptive properties in further investigations and in first line its medium-term and long-lasting biocompatibility. Furthermore, biomechanical features will have to be compared to those of conventional fixation techniques.