239 resultados para Jamar Dynamometer
Resumo:
Background: For the diagnosis of frailty exhaustion is a criteria currently measured by self-reported questionnaires, which are subjective and dependent on individual perception. The FR test has been developed as a bed side objective evaluation of muscle fatigue. The test was validated for the VM. However, the JD is frequently used to measure the grip strength. So the comparison of these devices is required to understand if FR is similar when measured with both devices. Methods: Fifty-four (29 female and 25 male; mean age: 39.98 ± 18.09) community-dwelling people were tested for muscle function. The Fatigue resistance (FR), which is the time during that grip strength drops to 50% of its maximum, was recorded with each device and simultaneous sEMG of the forearm muscles was obtained. The (co-)activation of agonist and antagonist muscles was calculated and compared with the differences between the performances with each device (controlling for gender and age). Results: FR was significantly better when measured with VM compared to JD. At all phases of the FR-test the antagonist muscle co-activation was significantly higher for VM compared to JD. In contrast, the agonist muscle activation level was significantly higher in JD compared to VM. When performing the FR-test with VM, both the agonist muscle activation and antagonist muscle co-activation decreased significantly (p<0.05). Whereas when using the JD, only a significant decrease in the antagonist muscle co-activation was observed. The difference in antagonist muscle activation between VM and JD was significantly related to the difference in FR between both devices. Conclusion: The results suggest that the FR-test when using the VM induces a more prominent muscle exhaustion than when using the JD, which makes the VM more suitable for measuring muscle fatigue resistance. However, these findings must be confirmed in a larger study population.
Resumo:
STUDY DESIGN: Clinical measurement. PURPOSE: The test-retest reliability of maximal grip strength measurements (MGSM) is examined in subjects for 12 weeks post-stroke together with maximal grip strength recovery and the maximal-grip and upper-extremity strength measurements' relationship with capacity and performance test scores. METHODS: A Jamar dynamometer and the Motricity Index (MI) were used for strength measurements. The Chedoke Arm and Hand Activity Inventory and ABILHAND questionnaire for evaluating capacities and performances. RESULTS: MGSM were reliable (Intraclass Correlation Coefficients = 0.97-0.99, Minimal Detectable Differences = 2.73-4.68 kg). Among the 34 participants, 47% did not have a measurable grip strength one week post-stroke but 50% of these recovered some strength within the first eight weeks. The MGSM and MI scores were correlated with scores of tests of capacity and performance (Spearman's Rank Correlation Coefficients = 0.69-0.94). CONCLUSIONS: MGSM are reliable in the first weeks after a stroke. LEVEL OF EVIDENCE: N/A.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Introdução – Avaliar a força de preensão mostrou ser de primordial importância pela sua relação com a capacidade funcional dos indivíduos, permitindo determinar níveis de risco para incapacidade futura e, assim, estabelecer estratégias de prevenção. Grande parte dos estudos utiliza o dinamómetro hidráulico JAMAR que fornece o valor da força isométrica obtida durante a execução do movimento de preensão palmar. Contudo, existem outros dinamómetros disponíveis, como é o caso do dinamómetro portátil computorizado E‑Link (Biometrics) que fornece o valor da força máxima (peak force), para além de outras variáveis, como a taxa de fadiga. Não existem, contudo, estudos que nos permitam aceitar e comparar ou não os valores obtidos com os dois equipamentos e porventura utilizá‑los indistintamente. Objetivos – Avaliar a concordância entre as medições da força de preensão (força máxima ou peak force em Kg) obtida a partir de dois equipamentos diferentes (dinamómetros portáteis): um computorizado (E‑Link, Biometrics) e outro hidráulico (JAMAR). Metodologia – Foram avaliados 29 indivíduos (13H; 16M; 22±7 anos; 23,2±3,3 kg/m2) em 2 dias consecutivos, na mesma altura do dia. A posição de teste escolhida foi a recomendada pela Associação Americana de Terapeutas Ocupacionais e foi escolhido o melhor resultado de entre 3 tentativas para a mão dominante. Realizou‑se uma análise correlacional entre os valores obtidos na variável analisada em cada equipamento (coeficiente de Spearman) e uma análise de Bland & Altman para verificar a concordância entre as duas medições. Resultados – O coeficiente de correlação entre as duas medições foi elevado (rS= 0,956; p<0,001) e, pela análise de Bland & Altman, os valores obtidos encontram‑se todos dentro do intervalo da média±2SD. Conclusões – As duas medições mostraram ser concordantes, revelando que os dinamómetros testados podem ser comparáveis ou utilizados indistintamente em diferentes estudos e populações. ABSTRACT: Introduction – Assess grip strength has proved to be of vital importance because of its relationship with functional capacity of individuals, in order to determine levels of risk for future disability and thereby establish prevention strategies. Most studies use the JAMAR Hydraulic dynamometer that provides the value of isometric force obtained during the performance of grip movement. However, there are other dynamometers available, such as portable computerized dynamometer E‑Link (Biometrics), which provides the value of maximum force (peak force) in addition to other variables as the rate of fatigue. There are no studies that allow us to accept or not and compare values obtained with both devices and perhaps use them interchangeably. Purpose – To evaluate the agreement between the measurements of grip strength (peak force or maximum force in kg) obtained from two different devices (portable dynamometers): a computerized (E‑Link, Biometrics) and a hydraulic (JAMAR). Methodology – 29 subjects (13H, 16M, 22 ± 7 years, 23.2 ± 3.3 kg/m2) were assessed on two consecutive days at the same time of day. The test position chosen was recommended by the American Association of Occupational Therapists and was considered the best result from three attempts for the dominant hand. A correlation was studied between values obtained in the variable analyzed in each equipment (Spearman coefficient) and Bland‑Altman analysis to assess the agreement between the two measurements. Results – The correlation coefficient between the two measurements was high (rs = 0,956, p <0,001) and Bland & Altman analysis of the values obtained are all within the range of mean±2SD. Conclusions – The two measurements were shown to be concordant, revealing that the tested dynamometers can be comparable or used interchangeably in different studies and populations.
Resumo:
Levels of risk for future disability can be assessed with grip strength. This assessment is of fundamental importance for establishing prevention strategies. It also allows verifying relationships with functional capacity of individuals. Most studies on grip strength use the JAMAR Hydraulic dynamometer that provides the value of isometric force obtained during the performance of grip movement and is considered the “gold standard” for measurement of grip strength. However, there are different dynamometers available commercially, such as portable computerized dynamometer E-Link (Biometrics), which provides the value of maximum force (peak force) in addition to other variables as the rate of fatigue for hand strength, among others. Of our knowledge, there are no studies that allow us to accept or not and compare values obtained with both devices and perhaps use them interchangeably. The aim of this study was to evaluate the absolute agreement between the measurements of grip strength (peak force or maximum force in kg) obtained from two different devices (portable dynamometers): a computerized (E-Link, Biometrics) and one hydraulic (JAMAR).
Resumo:
Spastic paraplegia, optic atrophy, and neuropathy (SPOAN) is an autosomal recessive complicated form of hereditary spastic paraplegia, which is clinically defined by congenital optic atrophy, infancy-onset progressive spastic paraplegia and peripheral neuropathy. In this study, which included 61 individuals (age 5-72 years, 42 females) affected by SPOAN, a comprehensive motor and functional evaluation was performed, using modified Barthel index, modified Ashworth scale, hand grip strength measured with a hydraulic dynamometer and two hereditary spastic paraplegia scales. Modified Barthel index, which evaluate several functional aspects, was more sensitive to disclose disease progression than the spastic paraplegia scales. Spasticity showed a bimodal distribution, with both grades 1 (minimum) and 4 (maximum). Hand grip strength showed a moderate inverse correlation with age. Combination of early onset spastic paraplegia and progressive polyneuropathy make SPOAN disability overwhelming.
Resumo:
Avaliar a força de preensão é fundamental pela sua relação com a capacidade funcional dos indivíduos, permitindo determinar níveis de risco para incapacidade futura e assim estabelecer estratégias de prevenção. Grande parte dos estudos utiliza o dinamómetro hidráulico JAMAR que fornece o valor da força isométrica obtida durante a execução do movimento de preensão palmar. Contudo, existem outros dinamómetros disponíveis, como é o caso do dinamómetro portátil computorizado E-Link (Biometrics), que fornece o valor da força máxima (peak force), mas também outras variáveis relacionadas, como por exemplo a taxa de fadiga. Não existem, contudo, estudos de análise de concordância que nos permitam aceitar e comparar ou não os valores obtidos com os dois equipamentos e porventura utilizá-los indistintamente.
Resumo:
A síndrome do túnel carpiano (STC) é considerada a neuropatia compressiva mais comum na população. É causada pela compressão directa sobre o nervo mediano no interior do túnel carpiano, que origina parestesias, dor na mão e disfunção muscular. Como consequência destes sintomas, os indivíduos vêem comprometida a sua funcionalidade ao nível das ocupações e, por consequência, alterado o seu desempenho ocupacional. Este trabalho tem como objectivo principal verificar de que forma a utilização da tala nocturna influencia a funcionalidade do indivíduo com STC. Concomitantemente pretende-se definir em que medida alterações das forças de preensão palmar e de pinças se relaciona com o uso da tala. Por último, identificar quais as variáveis sócio - demográficas e as que caracterizam a patologia que estão relacionadas com o problema em estudo e aos valores obtidos com as escalas do Boston Carpal Tunnel Questionnaire (BQTC), nos indivíduos dos grupos controlo e experimental. A amostra é constituída por 22 indivíduos no grupo controlo e 24 no grupo experimental, com diagnóstico de STC ligeiro e moderado. Foram aplicados o BCTQ, o dinamómetro e o pinch meter de Jamar. Os resultados deste estudo mostram uma diminuição significativa da sintomatologia da STC, após a aplicação da tala, nos momentos de reavaliação e follow up, (p=0,000 e p=0,004), assim como um aumento significativo da funcionalidade nos dois momentos (p=0,000 e p=0,004). Deste estudo conclui-se que a utilização da tala nocturna beneficia os indivíduos com STC ligeiro e moderado.
Resumo:
BACKGROUND: The JAMAR (Juvenile Arthritis Multidimensional Assessment Report) has been developed to evaluate the perception of the patient and his parents on different items: well-being, pain, functional status, quality of life, disease activity, disease course, side effects of medication, therapeutic compliance and satisfaction with illness outcome. Our aim was to compare disease's perception by JIA patients and their parents. METHODS: We included into the study 100 consecutive patients over 7 years of age. We asked both parent and child to complete the JAMAR questionnaire. For each patient we recorded demographic and disease related data. We examined the level of disagreement between children and parents for the quantitative items of the JAMAR: VAS Pain, VAS Disease Activity, VAS Well Being, Juvenile Arthritis Functional Score, HRQoL. Then we looked for a relation between discordance-rate and demographic and clinical variables. RESULTS: Children and parents' median scores for all five items were similar. Individual dyads agreement was low, with a large amount of pairs (80) discordant for at least one item. We found higher MD VAS and JADAS in more discordant dyads, suggesting that when the disease is more active discordance between child and parent increase. CONCLUSION: The JAMAR questionnaire is an important tool that helps clinicians to detect divergent child and parent's disease perceptions. It is essential that both patients and parents fill the JAMAR questionnaire for a complete clinical and psychosocial evaluation.
Resumo:
Background: Isometric grip strength, evaluated with a handgrip dynamometer, is a marker of current nutritional status and cardiometabolic risk and future morbidity and mortality. We present reference values for handgrip strength in healthy young Colombian adults (aged 18 to 29 years). Methods: The sample comprised 5.647 (2.330 men and 3.317 women) apparently healthy young university students (mean age, 20.6±2.7 years) attending public and private institutions in the cities of Bogota and Cali (Colombia). Handgrip strength was measured two times with a TKK analogue dynamometer in both hands and the highest value used in the analysis. Sex- and age-specific normative values for handgrip strength were calculated using the LMS method and expressed as tabulated percentiles from 3 to 97 and as smoothed centile curves (P3, P10, P25, P50, P75, P90 and P97). Results: Mean values for right and left handgrip strength were 38.1±8.9 and 35.9±8.6 kg for men, and 25.1±8.7 and 23.3±8.2 kg for women, respectively. Handgrip strength increased with age in both sexes and was significantly higher in men in all age categories. The results were generally more homogeneous amongst men than women. Conclusions: Sex- and age-specific handgrip strength normative values among healthy young Colombian adults are defined. This information may be helpful in future studies of secular trends in handgrip strength and to identify clinically relevant cut points for poor nutritional and elevated cardiometabolic risk in a Latin American population. Evidence of decline in handgrip strength before the end of the third decade is of concern and warrants further investigation
Resumo:
Pós-graduação em Saúde Coletiva - FMB
Resumo:
The objective of this study was to investigate the influence of the obesity and handgrip strength on the static balance of active older women in the opened and closed eyes conditions. Thirty one women aged from 65 to 75 years (16 eutrophic and 15 obese) were evaluated. Mean age and BMI of the eutrophic women were, respectively, 68.3 +/- 2.7 years and 23.4 +/- 1.6kg/m(2), and of the obese women were 69.1 +/- 2.7 years and 33.5 +/- 3kg/m(2). Handgrip strength was evaluated using a dynamometer (JAMAR). A tridimensional sensors system was used to evaluate the static postural balance. The tests were performed for 90 seconds, with eyes opened and closed. The mean handgrip strength of the eutrophic women was 25.1 +/- 4.6kgf and of the obese women was 24.8 +/- 5.2kgf, (p>0,05). Significant differences between groups were only observed in the maximum displacement with opened eyes (p=0,04) and closed eyes(p<0,01). There was no correlation between the maximum displacement neither with the BMI or the handgrip strength. The present study showed smaller a-p displacement in obese than in eutrophic women, with major statistic difference in the eyes closed condition. In the present study, the handgrip strength did not influence the static balance, however the obesity was a determinant factor for the smaller a-p displacement of the active older women.
Resumo:
Mode of access: Internet.
Resumo:
"From the 4th London edition."