198 resultados para Interobserver


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of intraductal carcinoma (IDC) of the prostate remains subjective because 3 sets of diagnostic criteria are in use. An internet survey was compiled from 38 photomicrographs showing duct proliferations: 14 signed out as high-grade prostatic intraepithelial neoplasia (HGPIN), 17 IDC, and 7 invasive cribriform/ductal carcinoma. Each image was assessed for the presence of 9 histologic criteria ascribed to IDC. Thirty-nine respondents were asked to rate images as (1) benign/reactive, (2) HGPIN, (3) borderline between HGPIN and IDC, (4) IDC, or (5) invasive cribriform/ductal carcinoma. Intraclass correlation coefficient was 0.68. There was 70% overall agreement with HGPIN, 43% with IDC, and 73% with invasive carcinoma (P < .001, χ(2)). Respondents considered 19 (50%) of 38 cases as IDC candidates, of which 5 (26%) had a two-thirds consensus for IDC; two-thirds consensus for either borderline or IDC was reached in 9 (47%). Two-thirds consensus other than IDC was reached in the remaining 19 of 38 cases, with 15 supporting HGPIN and 4 supporting invasive carcinoma. Findings that differed across diagnostic categories were lumen-spanning neoplastic cells (P < .001), 2× benign duct diameters (P < .001), duct space contours (round, irregular, and branched) (P < .001), papillary growth (P = .048), dense cribriform or solid growth (both P = .023), and comedonecrosis (P = .015). When the 19 of 38 images that attained consensus for HGPIN or invasive carcinoma were removed from consideration, lack of IDC consensus was most often attributable to only loose cribriform growth (5/19), central nuclear maturation (5/19), or comedonecrosis (3/19). Of the 9 histologic criteria, only 1 retained significant correlation with a consensus diagnosis of IDC: the presence of solid areas (P = .038). One case that attained IDC consensus had less than 2× duct enlargement yet still had severe nuclear atypia and nucleomegaly. Six fold nuclear enlargement was not significant (P = .083), although no image had both 6× nuclei and papillary or loose cribriform growth: a combination postulated as sufficient criteria for IDC. Finally, 20.5% of respondents agreed that an isolated diagnosis of IDC on needle biopsy warrants definitive therapy, 20.5% disagreed, and 59.0% considered the decision to depend upon clinicopathologic variables. Although IDC diagnosis remains challenging, we propose these criteria: a lumen-spanning proliferation of neoplastic cells in preexisting ducts with a dense cribriform or partial solid growth pattern. Solid growth, in any part of the duct space, emerges as the most reproducible finding to rule in a diagnosis of IDC. Comedonecrosis is a rarer finding, but in most cases, it should rule in IDC. Duct space enlargement to greater than 2× the diameter of the largest, adjacent benign spaces is usually present in IDC, although there may be rare exceptions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess interobserver agreement of ultrasound parameters for portal hypertension in hepatosplenic mansonic schistosomiasis. Spleen size, diameter of the portal, splenic and superior mesenteric veins and presence of thrombosis and cavernous transformation were determined by three radiologists in blinded and independent fashion in 30 patients. Interobserver agreement was measured by the kappa index and intraclass correlation coefficient. Interobserver agreement was considered substantial (κ = 0.714-0.795) for portal vein thrombosis and perfect (κ = 1) for cavernous transformation. Interobserver agreement measured by the intraclass correlation coefficient was excellent for longitudinal diameter of the spleen (r = 0.828-0.869) and splenic index (r = 0.816-0.905) and varied from fair to almost perfect for diameter of the portal (r = 0.622-0.675), splenic (r = 0.573-0.913) and superior mesenteric (r = 0.525-0.607) veins. According to the results, ultrasound is a highly reproducible method for the main morphological parameters of portal hypertension in schistosomiasis patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our objective was a prospective comparison of MR enteroclysis (MRE) with multidetector spiral-CT enteroclysis (MSCTE). Fifty patients with various suspected small bowel diseases were investigated by MSCTE and MRE. The MSCTE was performed using slices of 2.5 mm, immediately followed by MRE, obtaining T1- and T2-weighted sequences, including gadolinium-enhanced acquisition with fat saturation. Three radiologists independently evaluated MSCTE and MRE searching for 12 pathological signs. Interobserver agreement was calculated. Sensitivities and specificities resulted from comparison with pathological results ( n=29) and patient's clinical evolution ( n=21). Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and lymphadenopathy (ADP), showed better interobserver agreement on MSCTE than on MRE (BWT: 0.65 vs 0.48; BWE: 0.51 vs 0.37; ADP: 0.52 vs 0.15). Sensitivity of MSCTE was higher than that of MRE in detecting BWT (88.9 vs 60%), BWE (78.6 vs 55.5%) and ADP (63.8 vs 14.3%). Wilcoxon signed-rank test revealed significantly better sensitivity of MSCTE than that of MRE for each observer ( p=0.028, p=0.046, p=0.028, respectively). Taking the given study design into account, MSCTE provides better sensitivity in detecting lesions of the small bowel than MRE, with higher interobserver agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the inter/intraobserver variability of apparent diffusion coefficient (ADC) measurements in treated hepatic lesions and to compare ADC measurements in the whole lesion and in the area with the most restricted diffusion (MRDA). MATERIALS AND METHODS: Twenty-five patients with treated malignant liver lesions were examined on a 3.0T machine. After agreeing on the best ADC image, two readers independently measured the ADC values in the whole lesion and in the MRDA. These measurements were repeated 1 month later. The Bland-Altman method, Spearman correlation coefficients, and the Wilcoxon signed-rank test were used to evaluate the measurements. RESULTS: Interobserver variability for ADC measurements in the whole lesion and in the MRDA was 0.17 x 10(-3) mm(2)/s [-0.17, +0.17] and 0.43 x 10(-3) mm(2)/s [-0.45, +0.41], respectively. Intraobserver limits of agreement could be as low as [-0.10, +0.12] 10(-3) mm(2)/s and [-0.20, +0.33] 10(-3) mm(2)/s for measurements in the whole lesion and in the MRDA, respectively. CONCLUSION: A limited variability in ADC measurements does exist, and it should be considered when interpreting ADC values of hepatic malignancies. This is especially true for the measurements of the minimal ADC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Protein-energy malnutrition is highly prevalent in aged populations. Associated clinical, economic, and social burden is important. A valid screening method that would be robust and precise, but also easy, simple, and rapid to apply, is essential for adequate therapeutic management. OBJECTIVES: To compare the interobserver variability of 2 methods measuring food intake: semiquantitative visual estimations made by nurses versus calorie measurements performed by dieticians on the basis of standardized color digital photographs of servings before and after consumption. DESIGN: Observational monocentric pilot study. SETTING/PARTICIPANTS: A geriatric ward. The meals were randomly chosen from the meal tray. The choice was anonymous with respect to the patients who consumed them. MEASUREMENTS: The test method consisted of the estimation of calorie consumption by dieticians on the basis of standardized color digital photographs of servings before and after consumption. The reference method was based on direct visual estimations of the meals by nurses. Food intake was expressed in the form of a percentage of the serving consumed and calorie intake was then calculated by a dietician based on these percentages. The methods were applied with no previous training of the observers. Analysis of variance was performed to compare their interobserver variability. RESULTS: Of 15 meals consumed and initially examined, 6 were assessed with each method. Servings not consumed at all (0% consumption) or entirely consumed by the patient (100% consumption) were not included in the analysis so as to avoid systematic error. The digital photography method showed higher interobserver variability in calorie intake estimations. The difference between the compared methods was statistically significant (P < .03). CONCLUSIONS: Calorie intake measures for geriatric patients are more concordant when estimated in a semiquantitative way. Digital photography for food intake estimation without previous specific training of dieticians should not be considered as a reference method in geriatric settings, as it shows no advantages in terms of interobserver variability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The increase of apparent diffusion coefficient (ADC) in treated hepatic malignancies compared to pre-therapeutic values has been interpreted as treatment success; however, the variability of ADC measurements remains unknown. Furthermore, ADC has been usually measured in the whole lesion, while measurements should be probably centered on the area with the most restricted diffusion (MRDA) as it represents potential tumoral residue. Our objective was to compare the inter/intraobserver variability of ADC measurements in the whole lesion and in MRDA. Material and methods: Forty patients previously treated with chemoembolization or radiofrequency were evaluated (20 on 1.5T and 20 on 3.0T). After consensual agreement on the best ADC image, two readers measured the ADC values using separate regions of interest that included the whole lesion and the whole MRDA without exceeding their borders. The same measurements were repeated two weeks later. Spearman test and the Bland-Altman method were used. Results: Interobserver correlation in ADC measurements in the whole lesion and MRDA was as follows: 0.962 and 0.884. Intraobserver correlation was, respectively, 0.992 and 0.979. Interobserver limits of variability (mm2/sec*10-3) were between -0.25/+0.28 in the whole lesion and between -0.51/+0.46 in MRDA. Intraobserver limits of variability were, respectively: -0.25/+0.24 and -0.43/+0.47. Conclusion: We observed a good inter/intraobserver correlation in ADC measurements. Nevertheless, a limited variability does exist, and it should be considered when interpreting ADC values of hepatic malignancies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Conversion disorder (CD) is no longer a diagnosis of exclusion. The new DSM-V criteria highlight the importance of 'positive signs' on neurological examination. Only few signs have been validated, and little is known about their reliability. OBJECTIVE: The aim was to examine the clinical value of bedside positive signs in the diagnosis of CD presenting with weakness, gait or sensory symptoms by assessing their specificity, sensitivity and their inter-rater reliability. PATIENTS AND METHODS: Standardised video recorded neurological examinations were performed in 20 consecutive patients with CD and 20 'organic' controls. Ten previously validated sensory and motor signs were grouped in a scale. Thirteen additional motor/sensory 'positive signs', 14 gait patterns and 1 general sign were assessed in a pilot validation study. In addition, two blinded independent neurologists rated the video recordings to assess the inter-rater reliability (Cohen's κ) of each sign. RESULTS: A score of ≥4/14 on the sensory motor scale showed a 100% specificity (CI 85 to 100) and a 95% sensitivity (CI 85 to 100). Among the additional tested signs, 10 were significantly more frequent in CD than controls. The interobserver agreement was acceptable for 23/38 signs (2 excellent, 10 good, 11 moderate). CONCLUSIONS: Our study confirms that six bedside 'positive signs' are highly specific for CD with good-excellent inter-rater reliability; we propose to consider them as 'highly reliable signs'. In addition 13 signs could be considered as 'reliable signs' and six further signs as 'suggestive signs' while all others should be used with caution until further validation is available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate intra- and interobserver agreement in the identification of incidental enchondromas at knee magnetic resonance imaging, and to assess the prevalence of imaging findings. Materials and Methods Retrospective study reviewing 326 knee magnetic resonance images acquired in the period between November 2009 and September 2010. The images were independently and blindly analyzed by two specialists in musculoskeletal radiology, with the objective of identifying incidental enchondromas, presence of foci with signal similar to bone marrow and foci of signal absence suggestive of calcifications within the enchondromas. Inter- and intraobserver agreements were analyzed. Results Eleven lesions compatible with enchondromas (3.3%) were identified. The interobserver agreement for the presence of enchondroma was high. Prevalence of foci of bone marrow signal inside the enchondromas was of 54.55%, and foci suggestive of calcification corresponded to 36.36%. The intraobserver agreement for foci of bone marrow signal in enchondromas was perfect, and interobserver agreement was high. Conclusion The prevalence of incidental enchondromas in the current study was compatible with data in the literature. Excellent agreement was observed in the identification of enchondromas and in the assessment of imaging findings. A higher prevalence of fat signal foci was observed as compared with signal absence suggestive of calcifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine anatomical and functional pelvic floor measurements performed with three-dimensional (3-D) endovaginal ultrasonography in asymptomatic nulliparous women without dysfunctions detected in previous dynamic 3-D anorectal ultrasonography (echo defecography) and to demonstrate the interobserver reliability of these measurements. METHODS: Asymptomatic nulliparous volunteers were submitted to echo defecography to identify dynamic dysfunctions, including anatomical (rectocele, intussusceptions, entero/sigmoidocele and perineal descent) and functional changes (non-relaxation or paradoxical contraction of the puborectalis muscle) in the posterior compartment and assessed with regard to the biometric index of levator hiatus, pubovisceral muscle thickness, urethral length, anorectal angle, anorectal junction position and bladder neck position with the 3-D endovaginal ultrasonography. All measurements were compared at rest and during the Valsalva maneuver, and perineal and bladder neck descent was determined. The level of interobserver agreement was evaluated for all measurements. RESULTS: A total of 34 volunteers were assessed by echo defecography and by 3-D endovaginal ultrasonography. Out of these, 20 subjects met the inclusion criteria. The 14 excluded subjects were found to have posterior dynamic dysfunctions. During the Valsalva maneuver, the hiatal area was significantly larger, the urethra was significantly shorter and the anorectal angle was greater. Measurements at rest and during the Valsalva maneuver differed significantly with regard to anorectal junction and bladder neck position. The mean values for normal perineal descent and bladder neck descent were 0.6 cm and 0.5 cm above the symphysis pubis, respectively. The intraclass correlation coefficient ranged from 0.62-0.93. CONCLUSIONS: Functional biometric indexes, normal perineal descent and bladder neck descent values were determined for young asymptomatic nulliparous women with the 3-D endovaginal ultrasonography. The method was found to be reliable to measure pelvic floor structures at rest and during Valsalva, and might therefore be suitable for identifying dysfunctions in symptomatic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial baroreflex sensitivity estimated by pharmacological impulse stimuli depends on intrinsic signal variability and usually a subjective choice of blood pressure (BP) and heart rate (HR) values. We propose a semi-automatic method to estimate cardiovascular reflex sensitivity to bolus infusions of phenylephrine and nitroprusside. Beat-to-beat BP and HR time series for male Wistar rats (N = 13) were obtained from the digitized signal (sample frequency = 2 kHz) and analyzed by the proposed method (PRM) developed in Matlab language. In the PRM, time series were low-pass filtered with zero-phase distortion (3rd order Butterworth used in the forward and reverse direction) and presented graphically, and parameters were selected interactively. Differences between basal mean values and peak BP (deltaBP) and HR (deltaHR) values after drug infusions were used to calculate baroreflex sensitivity indexes, defined as the deltaHR/deltaBP ratio. The PRM was compared to the method traditionally (TDM) employed by seven independent observers using files for reflex bradycardia (N = 43) and tachycardia (N = 61). Agreement was assessed by Bland and Altman plots. Dispersion among users, measured as the standard deviation, was higher for TDM for reflex bradycardia (0.60 ± 0.46 vs 0.21 ± 0.26 bpm/mmHg for PRM, P < 0.001) and tachycardia (0.83 ± 0.62 vs 0.28 ± 0.28 bpm/mmHg for PRM, P < 0.001). The advantage of the present method is related to its objectivity, since the routine automatically calculates the desired parameters according to previous software instructions. This is an objective, robust and easy-to-use tool for cardiovascular reflex studies.