937 resultados para Internal fixation in fractures


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Open rather than closed reduction and internal fixation as well as primary definitive arthrodesis are well accepted for ligamentous and osseous Lisfranc injuries. For ligamentous injuries, a better outcome after primary definitive partial arthrodesis has been published. METHODS Of 135 Lisfranc injuries that were treated from 1998 to 2012 with open reduction, temporary internal fixation by screws and plates, and restricted weight bearing in a lower leg cast for 3 months followed by an arch support for another 4 to 6 weeks, 29 ligamentous Lisfranc injuries were available for follow-up. They were compared with 29 osseous Lisfranc injuries matched in age and gender. RESULTS Between the groups, there were no significant differences in average age (39.9 vs 38 years) or in average follow-up time (8.3 vs 9.1 years). Also, no significant differences were seen in the AOFAS midfoot score (84 vs 85.3 points), the FFI pain scale (9.9 vs 14.9 points), SF 36 physical component (56.2 vs 53.9 points), SF 36 mental component (57 vs 56.4 points), or VAS for pain (1.6 vs 1.5 points). The FFI function scale was significantly lower in the ligamentous group (11.6 vs 19.5 points). Radiographically, loss of reduction was recorded 3 times in the ligamentous injuries and 4 times in the osseous injuries. Arthritis was mild/moderate/severe in 5/3/0 ligamentous injuries and in 7/2/1 osseous injuries, requiring 1 definitive secondary Lisfranc arthrodesis in each group. CONCLUSION With longer and conservative postoperative management, open reduction and temporary internal fixation in ligamentous and osseous Lisfranc injuries led to equal medium-term outcome. Inferior outcome in ligamentous injuries was not found. LEVEL OF EVIDENCE Level III, retrospective comparative cohort study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pocos estudios han evaluado el tratamiento de las fracturas desplazadas de cuello femoral en pacientes menores de 65 años de edad, y no han sido claramente definidos los factores de riesgo para necrosis avascular o no-unión dentro de este rango de edad. Para determinar los factores asociados a la necrosis avascular de la cabeza femoral (AVN) y no-unión en pacientes menores de 65 años de edad con fracturas desplazadas del cuello femoral tratados con reducción y fijación interna, se realizó un estudio retrospectivo de 29 fracturas desplazadas del cuello femoral en 29 pacientes consecutivos tratados en una sola institución. La influencia de la edad, la energía del trauma, tipo de reducción, y el tiempo entre la fractura y el tratamiento en desarrollo de la AVN y no-unión fueron evaluados. Los pacientes que desarrollaron NAV fueron significativamente mayores y sufrieron un trauma de más baja energía que en los casos sin AVN. Ninguna variable fue asociada con la no-unión. La regresión logística determinó que sólo la edad se asoció de forma independiente a NAV. La edad es un buen predictor para el desarrollo de NAV, con un C-estadístico de 0.861, y un mejor corte-determinado en 53,5 años. Conclusión: Los pacientes de entre 53,5 y 65 años presentan un riesgo más alto de NAV. La artroplastia primaria se debe considerar en este subgrupo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to compare by qualitative histology the efficacy of rigid internal fixation with titanium system and the Lacto Sorb® system in mandibular fractures in rabbits. Thirty male adult rabbits Oryctolagus cuniculus were used. Unilateral mandibular osteotomies were performed between the canine and first premolar. The animals were divided into two groups: for Group I - rigid internal fixation was performed with titanium system 1.5 mm (Synthes, Oberdorf, Switzerland), with two screws of 6 mm (bicortical) on each side of the osteotomy. For Group II-rigid internal fixation was performed with PLLA/PGA system 1.5 mm (Lacto Sorb®, WLorenz, Jacksonville, FL, USA). The histological analysis evaluated the presence of inflammatory reaction, degree of bone healing and degree of resorption of the Lacto Sorb® screws. The results of both fixation systems were similar, only with a small difference after 15 and 30 days. In Group I a faster bony healing was noted. But after 60 days, bony healing was similar in both groups. It is concluded that both PLLA/PGA and titanium plates and screws provide sufficient strength to permit mandibular bone healing. The resorption process of PLLA/PGA osteosynthesis material did not cause acute or chronic inflammatory reaction or foreign body reaction during the studied period. © 2004 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to perform a physicochemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures. Twenty-eight polyurethane mandibles were uniformly sectioned on the left angle. These were divided into 4 groups: group Eng 1P, one 2.0-mm plate and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates, the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the Ti-15Mo alloy. Each group was subjected to linear vertical loading at the first molar on the plated side in a mechanical testing unit. Means and standard deviations were compared with respect to statistical significance using ANOVA. The chemical composition of the Ti-15Mo alloy was close to the nominal value. The mapping of Mo and Ti showed a homogeneous distribution. SEM of the screw revealed machining debris. For the plates, only the cpTi plate undergoes a surface treatment. The metallographic analysis reveals granular microstructure, from the thermomechanical trials. A statistically significant difference was found (P < 0.05) when the comparison between both internal fixation techniques was performed. The 2P technique showed better mechanical behavior than 1P.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bennett fractures are unstable, and, with inadequate treatment, lead to osteoarthritis, weakness and loss of function of the first carpometacarpal joint. This study focuses on long-term functional and radiological outcomes after open reduction and internal fixation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Distal radius fractures stabilized by open reduction internal fixation (ORIF) have become increasingly common. There is currently no consensus on the optimal time to commence range of motion (ROM) exercises post-ORIF. A retrospective cohort review was conducted over a five-year period to compare wrist and forearm range of motion outcomes and number of therapy sessions between patients who commenced active ROM exercises within the first seven days and from day eight onward following ORIF of distal radius fractures. One hundred and twenty-one patient cases were identified. Clinical data, active ROM at initial and discharge therapy assessments, fracture type, surgical approaches, and number of therapy sessions attended were recorded. One hundred and seven (88.4%) cases had complete datasets. The early active ROM group (n = 37) commenced ROM a mean (SD) of 4.27 (1.8) days post-ORIF. The comparator group (n = 70) commenced ROM exercises 24.3 (13.6) days post-ORIF. No significant differences were identified between groups in ROM at initial or discharge assessments, or therapy sessions attended. The results from this study indicate that patients who commenced active ROM exercises an average of 24 days after surgery achieved comparable ROM outcomes with similar number of therapy sessions to those who commenced ROM exercises within the first week.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project examined the differences in healing of metaphyseal bone, when the implants of variable stiffness are used for fracture fixation. This knowledge is important in development of novel orthopaedic implants, used in orthopaedic surgery to stabilise the fractures. Dr Koval used a mouse model to create a fracture, and then assessed its healing with a combination of mechanical testing, microcomputed tomography and histomorphometric examination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SUMMARY: Fracture stabilization in the diabetic patient is associated with higher complication rates, particularly infection and impaired wound healing, which can lead to major tissue damage, osteomyelitis, and higher amputation rates. With an increasing prevalence of diabetes and an aging population, the risks of infection of internal fixation devices are expected to grow. Although numerous retrospective clinical studies have identified a relationship between diabetes and infection, currently there are few animal models that have been used to investigate postoperative surgical-site infections associated with internal fixator implantation and diabetes. The authors therefore refined the protocol for inducing hyperglycemia and compared the bacterial burden in controls to pharmacologically induced type 1 diabetic rats after undergoing internal fracture plate fixation and Staphylococcus aureus surgical-site inoculation. Using an initial series of streptozotocin doses, followed by optional additional doses to reach a target blood glucose range of 300 to 600 mg/dl, the authors reliably induced diabetes in 100 percent of the rats (n = 16), in which a narrow hyperglycemic range was maintained 14 days after onset of diabetes (mean ± SEM, 466 ± 16 mg/dl; coefficient of variation, 0.15). With respect to their primary endpoint, the authors quantified a significantly higher infectious burden in inoculated diabetic animals (median, 3.2 × 10 colony-forming units/mg dry tissue) compared with inoculated nondiabetic animals (7.2 × 10 colony-forming units/mg dry tissue). These data support the authors' hypothesis that uncontrolled diabetes adversely affects the immune system's ability to clear Staphylococcus aureus associated with internal hardware.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to compare the bone repair along a mandibular body osteotomy stabilized with 2.0 mm absorbable and metallic systems. 12 male, adult mongrel dogs were divided into two groups (metallic and absorbable) and subjected to unilateral osteotomy between the mandibular third and fourth premolars, which was stabilized by applying two 4-hole plates. At 2 and 18 weeks, three dogs from each group were killed and the osteotomy sites were removed and divided equally into three parts: the upper part was labelled the tension third (TT), the lower part the compression third (CT), and the part between the TT and CT the intermediary third (IT). Regardless of the treatment system, union between the fragments was observed at 18 weeks and the CT showed more advanced stages of bone repair than the TT. Histometric analysis did not reveal any significant differences among the 3 parts or systems in the distance between bone fragments at 2 weeks. Although at 18 weeks the proportions of newly formed bone did not differ among TT, IT and CT, significantly enhanced bone formation was observed in all sections for the metallic group. The patterns of repair were distinct between treatments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The extended lateral L-shaped approach for the treatment of displaced intra-articular fractures of the calcaneum may be complicated by wound infection, haematoma, dehiscence and injury to the sural nerve. In an effort to reduce the risk of problems with wound healing a technique was developed that combined open reduction and fixation of the joint fragments and of the anterior process with percutaneous reduction and screw fixation of the tuberosity. A group of 24 patients with unilateral isolated closed Sanders type II and III fractures was treated using this technique and compared to a similar group of 26 patients managed by the extended approach and lateral plating. The operation was significantly shorter (p < 0.001) in the first group, but more minor secondary procedures and removal of heel screws were necessary. There were no wound complications in this group, whereas four minor complications occurred in the second group. The accuracy and maintenance of reduction, and ultimate function were equivalent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fractures of long bones are sometimes treated using various types of fracture fixation devices including internal plate fixators. These are specialised plates which are used to bridge the fracture gap(s) whilst anatomically aligning the bone fragments. The plate is secured in position by screws. The aim of such a device is to support and promote the natural healing of the bone. When using an internal fixation device, it is necessary for the clinician to decide upon many parameters, for example, the type of plate and where to position it; how many and where to position the screws. While there have been a number of experimental and computational studies conducted regarding the configuration of screws in the literature, there is still inadequate information available concerning the influence of screw configuration on fracture healing. Because screw configuration influences the amount of flexibility at the area of fracture, it has a direct influence on the fracture healing process. Therefore, it is important that the chosen screw configuration does not inhibit the healing process. In addition to the impact on the fracture healing process, screw configuration plays an important role in the distribution of stresses in the plate due to the applied loads. A plate that experiences high stresses is prone to early failure. Hence, the screw configuration used should not encourage the occurrence of high stresses. This project develops a computational program in Fortran programming language to perform mathematical optimisation to determine the screw configuration of an internal fixation device within constraints of interfragmentary movement by minimising the corresponding stress in the plate. Thus, the optimal solution suggests the positioning and number of screws which satisfies the predefined constraints of interfragmentary movements. For a set of screw configurations the interfragmentary displacement and the stress occurring in the plate were calculated by the Finite Element Method. The screw configurations were iteratively changed and each time the corresponding interfragmentary displacements were compared with predefined constraints. Additionally, the corresponding stress was compared with the previously calculated stress value to determine if there was a reduction. These processes were continued until an optimal solution was achieved. The optimisation program has been shown to successfully predict the optimal screw configuration in two cases. The first case was a simplified bone construct whereby the screw configuration solution was comparable with those recommended in biomechanical literature. The second case was a femoral construct, of which the resultant screw configuration was shown to be similar to those used in clinical cases. The optimisation method and programming developed in this study has shown that it has potential to be used for further investigations with the improvement of optimisation criteria and the efficiency of the program.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic. Each of the methods previously used in the literature were assessed for their effect on the bending of the sample and concordant stiffness. The choice of outcome measures used in in vitro fracture studies was also assessed. Mechanical testing was conducted on seven hole locked plated constructs in each method for comparison. Based on the assessment of each method the use of spherical bearings, ball joints or similar is suggested at both ends of the sample. The use of near and far cortex movement was found to be more comprehensive and more accurate than traditional centrally calculated inter fragmentary movement values; stiffness was found to be highly susceptible to the accuracy of deformation measurements and constraint method, and should only be used as a within study comparison method. The reported stiffness values of locked plate constructs from in vitro mechanical testing is highly susceptible to testing constraints and output measures, with many standard techniques overestimating the stiffness of the construct. This raises the need for further investigation into the actual mechanical behaviour within the fracture gap of these devices.