10 resultados para Immulite®


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rheumatoid arthritis (RA) is an autoimmune disease characterized by synovitis, progressive joint destruction, and disability. Reactive arthritis (ReA) is a sterile joint inflammation following a distant mucosal infection. The clinical course of these diseases is variable and cannot be predicted with reasonable accuracy by clinical and laboratory markers. The predictive value of circulating soluble interleukin-2 receptor (sIL-2R), a marker of lymphocyte activation, measured by Immulite® automated immunoassay analyzer, was evaluated in two cohorts of RA patients. In 175 patients with active early RA randomized to treatment with either on disease-modifying antirheumatic drug (DMARD) or a combination of 3 DMARDs and prednisolone, low baseline sIL-2R level predicted remission after 6 months in patients treated with a single DMARD. In 24 patients with active RA refractory to DMARDs, low baseline sIL-2R level predicted rapid clinical response to treatment with infliximab, an anti-tumour necrosis factor antibody. Furthermore, in a cohort of 26 patients with acute ReA, high baseline sIL-2R level predicted remission after 6 months. Levels of circulating soluble E-selectin (sE-selectin), a marker of endothelial activation, were measured annually by enzyme-linked immunosorbent assay (ELISA) in a cohort of 85 patients with early RA. During a five-year follow-up, sE-selectin levels were associated with activity and outcome of RA. The levels of neutrophil and monocyte CD11b/CD18 expression measured by flow cytometry, and circulating levels of sE-selectin measured by ELISA, and procalcitonin by immunoluminometric assay, were compared in 28 patients with acute ReA and 16 patients with early RA. The levels of the markers were comparable in ReA, RA, and healthy control subjects. In conlusion, sIL-2R may provide a new predictive marker in early RA treated with a single DMARD and refractory RA treated with infliximab. In addition, sIL-2R level predicts remission in acute ReA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O nível sérico do Fator de crescimento semelhante à insulina tipo I (IGF-I) é fundamental para auxiliar no dignóstico e controle terapêutico dos transtornos relacionados à secreção do Hormônio de Crescimento (GH), bem como no diagnóstico e seguimento de outras doenças. Estabelecer valores de referência para as dosagens séricas de IGF-I por um ensaio imunoquimioluminométrico (ICMA), utilizando o sistema automatizado Immulite 2000/Diagnostic Products Corporation (DPC), e por um ensaio imunoradiométrico (IRMA), utilizando o kit comercial ACTIVE IGF-I/Diagnostic System Laboratories (DSL)-5600, numa população brasileira adulta da cidade do Rio de Janeiro. Este estudo, aprovado pelo Comitê de Ética do Instituto Estadual de Hematologia Arthur de Siqueira Cavalcanti, Rio de Janeiro, Brasil, incluiu amostras de 484 indivíduos saudáveis (251 homens e 233 mulheres) com idades entre 18 e 70 anos. As amostras foram estudadas por ICMA- Immulite 2000/DPC and IRMA- ACTIVE IGF-I/DSL-5600. Para análise dos dados foram utilizados modelos específicos para idade e sexo, após transformação dos dados de IGF-I. Foi observada uma lenta diminuição dos níveis de IGF-I com a idade usando ambos os ensaios. Os níveis de IGF-I foram signicativamente (p=0,0181) mais elevados em mulheres do que em homens, quando as amostras foram analisadas usando ICMA. Não houve diferença significativa dos níveis de IGF-I entre homens e mulheres quando as amostras foram analisadas usando IRMA. Este estudo estabeleceu valores de referência de IGF-I específicos para idade e sexo, determinados com o sistema automatizado ICMA-Immulite 2000/DPC, e valores de referência de IGF-I específicos para idade, determinados com o kit comercial IRMA- ACTIVE IGF-I/DSL-5600, em uma população adulta brasileira, da cidade do Rio de Janeiro.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A prolactina(PRL) humana circula em múltiplas formas de diferentes tamanhos moleculares, das quais três são detectadas na cromatografia por filtração em gel(CFG): Little ou monomérica(mPRL), Big( bPRL) e Big-Big ou macroprolactina( bbPRL ou macroPRL). Em pessoas normais, a principal forma é a mPRL(85 a 90% do total) com uma pequena proporção de macroPRL. Em algumas pessoas, porém, ocorre uma maior quantidade de macroPRL, um fenômeno denominado Macroprolactinemia, que se sabe estar presente entre 10-25% dos soros hiperprolactinêmicos. É importante a sua identificação para evitar investigação e tratamento desnecessário. O método padrão para sua detecção é a cromatografia por filtração em gel( CFG); porém, a precipitação com polietilenoglicol( PEG) é um método de triagem simples, confiável e de baixo custo. Os testes com PEG originais foram feitos com o ensaio imunofluorimétrico( IFMA) Delfia para PRL. Objetivo: Validar um teste sensível e específico para a triagem de macroPRL baseado no ensaio de PRL quimioluminescente Immulite DPC. Resultados e métodos: Analisamos amostras séricas de 142 pessoas de ambos sexos. Baseado nessas amostras de rotina, dosamos a PRL seguida da precipitação com PEG e cálculo da recuperação de PRL( %R de PRL). Destes soros, 88 foram submetidos a cromatografia com filtração em Gel. Foi definido um ponto-de-corte para a presença de macroPRL, baseado numa curva ROC, ao comparar-se os resultados do teste de precipitação com PEG e os da CFG. O ponto-de-corte foi definido em 60%, com o achado de um teste com sensibilidade de 88,9% e especificidade de 98,6%. Correlacionou-se a dosagem de mPRL com a presença de macroPRL na cromatografia. Conclusão: Validamos um teste de triagem para macroPRL baseado no ensaio quimioluminescente DPC Immulite com sensibilidade de 88,9% e especificidade de 98,6 % para a porcentagem de recuperação PRL de 60%. O achado de uma valor de mPRL menor ou igual a 20 depois da precipitação com PEG vai suportar este diagnóstico. A prevalência( 20,4%) de macroPRL encontrada em nosso estudo, utilizando a metodologia proposta, é semelhante à encontrada na literatura.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The determination of leukocyte alkaline phosphatasd (LAP) is used as an aid to diagnose many diseases in the laboratory. For example, it can be used to distinguish chronic myeloid leukemia (CML) from other myeloproliferative disorders (particularly myelofibrosis and polycythemia) and leukemoid reactions (LR). Traditionally, this test is performed with the use of subjective cytochemical assays that assign a score to the level of LAP. Here we present a nonsubjective, quantitative, sensitive, and inexpensive chemiluminescent technique that determines LAP based on the commercial reagent Immulite (R) (AMPPD). To validate this methodology, intact leukocytes obtained from 32 healthy subjects, nine CML patients, and nine LR patients were submitted to the optimized protocol. By measuring the light emission elicited by four concentrations of neutrophils, we were able to estimate the activity of LAP per cell (the slope of the curve obtained by linear regression). A high linear correlation was found between the chemiluminescent result (slope) and the cytochemical score. The slope for healthy individuals ranged between 0.61 and 8.49 (10(-5) mV.s/cell), with a median of 2.04 (10(-5) mV.s/cell). These results were statistically different from those of CML patients (range = 0.07-1.75, median = 0.79) and LR patients (range = 3.84-47.24, median 9.58; P < 0.05).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Physical activity is associated with lower cardiovascular disease risk factors, being cardiorespiratory fitness a major component of physical activity health related. Body fatness and sarcopenia are related to sedentary lifestyle leading to proinflammatory stress and lower cadiorespiratory capacity. This study aimed correlates C-reactive protein with cardiorespiratory fitness, analyzing the influences of anthropometrics variables and metabolic syndrome (MS) presence. the cross-sectional retrospective study included baseline data of 194 adults (62 male and 132 female), 53,74 ± 8,77 years, clinically and ethically selected for a lifestyle modification program. Total cholesterol (TC) and cholesterol lipoprotein fractions, triglycerides (TG) and glucose was dosed by dry chemistry (Vitros® system, Johnson & Johnson). Blood leukocytes was quantified by automatic cell counter (Coulter ABX®, Horiba). LDL-cholesterol was obtained by Friedwald formula. Serum ultrasensitive C-reactive protein (US-CRP) was accessed by the immunochemoluminescence method (Immulite 2000®, DPC Medlab). Weight, height, body mass index (BMI) and waist circumference (WC) were measured. Muscular mass and fat mass were obtained by bioelectrical impedance analysis (impedancemeter Quantum BIA-101Q®, Clinton Township). Arterial blood pressure was checked by auscultatory method and cardiorespiratory fitness was determined by ergoespirometric test (Balke protocol). The metabolic syndrome was diagnosed according NCEP – ATP III (2001), following recommendations of American Diabetes Association (2004). Pearson’s correlation crude and adjusted for confounders variables with p<0,05. The prevalence of MS was 30.4%. Crude correlation shows hsCRP was correlated inverse and significantly with VO2max (r= -0.21; p=-0.003) ...(Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare the total plasma cortisol values obtained from three widely used immunoassays and a high pressure liquid chromatography (HPLC) technique on samples obtained from patients with sepsis. Design and setting: Observational interventional in the general intensive care unit of a metropolitan hospital. Patients and participants: Patients admitted to the intensive care unit with a diagnosis of sepsis and fulfilling criteria of systemic inflammatory response syndrome. Interventions: Standard short synacthen test performed with 250 mu g cosyntropin. Measurements and results: Two of the three immunoassays returned results significantly higher than those obtained by HPLC: Immulite by 95% (95%CI 31-188%) and TDx by 79% (21-165%). The limits of agreement for all three immunoassays with HPLC ranged from -62% to 770%. In addition, by classifying the patients into responders and non-responders to ACTH by standard criteria there was concordance in all assays in only 44% of patients. Conclusions: Immunoassay estimation of total plasma cortisol in septic patients shows wide assay related variation that may have significant impact in the diagnosis of relative adrenal insufficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre no Instituto Superior de Ciências da Saúde Egas Moniz