997 resultados para Imaging diagnostic


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A prospective randomised controlled clinical trial of treatment decisions informed by invasive functional testing of coronary artery disease severity compared with standard angiography-guided management was implemented in 350 patients with a recent non-ST elevation myocardial infarction (NSTEMI) admitted to 6 hospitals in the National Health Service. The main aims of this study were to examine the utility of both invasive fractional flow reserve (FFR) and non-invasive cardiac magnetic resonance imaging (MRI) amongst patients with a recent diagnosis of NSTEMI. In summary, the findings of this thesis are: (1) the use of FFR combined with intravenous adenosine was feasible and safe amongst patients with NSTEMI and has clinical utility; (2) there was discordance between the visual, angiographic estimation of lesion significance and FFR; (3). The use of FFR led to changes in treatment strategy and an increase in prescription of medical therapy in the short term compared with an angiographically guided strategy; (4) in the incidence of major adverse cardiac events (MACE) at 12 months follow up was similar in the two groups. Cardiac MRI was used in a subset of patients enrolled in two hospitals in the West of Scotland. T1 and T2 mapping methods were used to delineate territories of acute myocardial injury. T1 and T2 mapping were superior when compared with conventional T2-weighted dark blood imaging for estimation of the ischaemic area-at-risk (AAR) with less artifact in NSTEMI. There was poor correlation between the angiographic AAR and MRI methods of AAR estimation in patients with NSTEMI. FFR had a high accuracy at predicting inducible perfusion defects demonstrated on stress perfusion MRI. This thesis describes the largest randomized trial published to date specifically looking at the clinical utility of FFR in the NSTEMI population. We have provided evidence of the diagnostic and clinical utility of FFR in this group of patients and provide evidence to inform larger studies. This thesis also describes the largest ever MRI cohort, including with myocardial stress perfusion assessments, specifically looking at the NSTEMI population. We have demonstrated the diagnostic accuracy of FFR to predict reversible ischaemia as referenced to a non-invasive gold standard with MRI. This thesis has also shown the futility of using dark blood oedema imaging amongst all comer NSTEMI patients when compared to novel T1 and T2 mapping methods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE. Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION. We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The authors report the magnetic resonance imaging diagnostic features in two cases with respectively lumbar epidural hematoma and cavernous hemangioma of the lumbar epidural space. Enhanced MRI T1-weighted scans show a hyperintense signal rim surrounding the vascular lesion. Non-enhanced T2-weighted scans showed hyperintense signal.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Cardiac magnetic resonance imaging provides detailed anatomical information on infarction. However, few studies have investigated the association of these data with mortality after acute myocardial infarction. Objective: To study the association between data regarding infarct size and anatomy, as obtained from cardiac magnetic resonance imaging after acute myocardial infarction, and long-term mortality. Methods: A total of 1959 reports of “infarct size” were identified in 7119 cardiac magnetic resonance imaging studies, of which 420 had clinical and laboratory confirmation of previous myocardial infarction. The variables studied were the classic risk factors – left ventricular ejection fraction, categorized ventricular function, and location of acute myocardial infarction. Infarct size and acute myocardial infarction extent and transmurality were analyzed alone and together, using the variable named “MET-AMI”. The statistical analysis was carried out using the elastic net regularization, with the Cox model and survival trees. Results: The mean age was 62.3 ± 12 years, and 77.3% were males. During the mean follow-up of 6.4 ± 2.9 years, there were 76 deaths (18.1%). Serum creatinine, diabetes mellitus and previous myocardial infarction were independently associated with mortality. Age was the main explanatory factor. The cardiac magnetic resonance imaging variables independently associated with mortality were transmurality of acute myocardial infarction (p = 0.047), ventricular dysfunction (p = 0.0005) and infarcted size (p = 0.0005); the latter was the main explanatory variable for ischemic heart disease death. The MET-AMI variable was the most strongly associated with risk of ischemic heart disease death (HR: 16.04; 95%CI: 2.64-97.5; p = 0.003). Conclusion: The anatomical data of infarction, obtained from cardiac magnetic resonance imaging after acute myocardial infarction, were independently associated with long-term mortality, especially for ischemic heart disease death.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to confirm that the radiation doses received by attendants who manually restrain infants during fluoroscopic procedures are low. Doses to the hands and neck of three radiologists and three nurses performing or assisting at all the fluoroscopic procedures in a children's hospital were measured for 1 month using thermoluminescent dosemeters. All fluoroscopy on children at this hospital is performed without an antiscatter grid. Total doses for the neck ranged from 20 to 50 mu Sv per week and for hands from 40 to 210 mu Sv per week. These doses were shared by the three radiologists and the three nurses. Individual doses received per staff member are very small when compared with the doses received by interventional radiology staff. Doses received by staff in this study were of the order of 5% of the limit advised by the National Health and Medical Research Council of Australia (NHMRC) for radiation workers. Nurses received larger doses than radiologists and steps will be taken to reduce this dose further.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação submetida para obtenção do grau de Doutor em Saúde Pública Especialidade de Economia da Saúde

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Appropriateness Criteria for nuclear imaging exams were created by American College of Cardiology (ACC) e American Society of Nuclear Cardiology (ASNC) to allow the rational use of tests. Little is known whether these criteria have been followed in clinical practice. Objective: To evaluate whether the medical applications of myocardial perfusion scintigraphy (MPS) in a private nuclear medicine service of a tertiary cardiology hospital were suitable to the criteria of indications proposed by the American medical societies in 2005 and 2009 and compare the level of indication of both. Methods: We included records of 383 patients that underwent MPS, November 2008 up to February 2009. Demographic characteristics, patient's origin, coronary risk factors, time of medical graduation and appropriateness criteria of medical applications were studied. The criteria were evaluated by two independent physicians and, in doubtful cases, defined by a medical expert in MPS. Results: Mean age was 65 ± 12 years. Of the 367 records reviewed, 236 (64.3%) studies were performed in men and 75 (20.4%) were internee. To ACC 2005, 255 (69.5%) were considered appropriate indication and 13 (3.5%) inappropriate. With ACC 2009, 249 (67.8%) were considered appropriate indications and 13 (5.2%) inappropriate. Conclusions: We observed a high rate of adequacy of medical indications for MPS. Compared to the 2005 version, 2009 did not change the results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The diagnosis of pancreatic masses represents a great challenger for imaging studies. However the occurrence of pancreatic masses have been reported more frequently in the last years due to advances in imaging diagnostic methods. During the last decade, the surgical approach of pancreatic masses was limited to an attempt of establishing histological diagnosis, staging and evaluation of resection of these masses. Recently, the approach and staging of pancreatic masses was facilitated by sophisticated methods of diagnosis, especially, ultrasound, dynamic computerized tomography, magnetic resonance imaging (/RM), angiography, endoscopic retrograde cholangiopancreatography (CPRE), endoscopic ultrasound, laparoscopy and biochemical tumors markers. The present paper reports a case of a pancreatic mass due to foreign body in which the imaging study helped to determine out this rare etiological agent that has not been previouly described in literature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A ruptura do ligamento cruzado cranial é uma das causas mais comuns de claudicação do membro pélvico de cães. A radiografia e a ultrassonografia são métodos de diagnóstico frequentemente utilizados na rotina clínica de pequenos animais, porém a tomografia computadorizada é uma modalidade de imagem ainda pouco estudada para avaliar a articulação do joelho de cães. O presente trabalho teve por objetivo avaliar a contribuição do contraste negativo na artrografia tomográfica do joelho normal de cães, para visibilizar as estruturas intra-articulares e padronizar o uso desse contraste na articulação. Foram utilizados 24 membros pélvicos de cães de raças variadas, selecionados pela ausência de histórico de doença articular prévia do joelho e por apresentarem exames radiográficos, ultrassonográficos e macroscópicos normais. O experimento foi delineado em dois grupos, sendo o grupo I constituído de animais com peso até 20 kg e grupo II acima de 20 kg. Foram feitos cortes tomográficos com o membro flexionado e estendido. A quantidade média de ar empregada para a distensão da cápsula articular foi de 49 ml para o Grupo I e de 81 ml para o Grupo II. Utilizou-se um tubo de látex na porção distal à articulação do joelho para reduzir o escape de ar pelo tendão extensor digital profundo, que possui comunicação intra-articular. Foi possível visibilizar pela imagem tomográfica, em todas as articulações, as seguintes estruturas: ligamento cruzado cranial e caudal, meniscos medial e lateral, ligamento patelar, ligamentos colaterais e cápsula articular. Desta forma, o contraste negativo se mostrou uma alternativa eficaz para auxiliar a identificação das estruturas anatômicas do joelho na artrografia tomográfica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The computed tomography, devised by Godfrey Hounsfield and Allan Cormack, is in its fourth decade of the clinical use and has presented to be a very useful tool in the diagnosis of several pathologies. For this reason, its use is increasing each day, due to technological progress since its creation. Due to be more and more utilized, the equipment must be in good operating conditions, because it is subject to variance and wearing, damage the quality of diagnosis. To evaluate whether the performance of the scanner remains constant along the time and the dose received by the patient is within the desired limits, periodic tests of quality control must be performed. For this subject, the regulation 453 (June 01, 1998) was created, which determines the need of the implementation of a program for quality assurance (PGQ), where, in addition to the tests of quality control, are established the necessary measurements for the proper functioning of the equipment, generating a trustworthy diagnosis, reducing the dose for the patient and the costs. In this document, are presented tests of quality control carried out in hospitals of the city of Sao Paulo carried out together with the Technical Section of Applications by Imaging Diagnostic (STADI) of the Institute of Electrotechnics and Energy of the University of São Paulo (IEE/USP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The diagnosis of various diseases has become more accessible and accurate with the rapid development of imaging modalities aiming to assist in medical diagnosis, and thereby in veterinary medicine. Different diagnostic imaging modalities such as ultrasonography, computed tomography, magnetic resonance imaging and scintigraphy can be performed to obtain information about thyroid diseases, each one with advantages and disadvantages, depending on the thyroid disease in question. Diagnostic imaging is a tool that not only assists in the diagnosis, but also helps treatment and assessment of prognosis of thyroid diseases. The aim of this article is to discuss the limitations and benefits of each diagnostic imaging modality available in the veterinary medical field, and also to present the newest diagnostic imaging modalities in order to maximize and make more accurate diagnosis of thyroid diseases.