978 resultados para INTERACTION SCREENING-PROGRAMS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To evaluate drug interaction software programs and determine their accuracy in identifying drug-drug interactions that may occur in intensive care units. Setting The study was developed in Brazil. Method Drug interaction software programs were identified through a bibliographic search in PUBMED and in LILACS (database related to the health sciences published in Latin American and Caribbean countries). The programs` sensitivity, specificity, and positive and negative predictive values were determined to assess their accuracy in detecting drug-drug interactions. The accuracy of the software programs identified was determined using 100 clinically important interactions and 100 clinically unimportant ones. Stockley`s Drug Interactions 8th edition was employed as the gold standard in the identification of drug-drug interaction. Main outcome Sensitivity, specificity, positive and negative predictive values. Results The programs studied were: Drug Interaction Checker (DIC), Drug-Reax (DR), and Lexi-Interact (LI). DR displayed the highest sensitivity (0.88) and DIC showed the lowest (0.69). A close similarity was observed among the programs regarding specificity (0.88-0.92) and positive predictive values (0.88-0.89). The DIC had the lowest negative predictive value (0.75) and DR the highest (0.91). Conclusion The DR and LI programs displayed appropriate sensitivity and specificity for identifying drug-drug interactions of interest in intensive care units. Drug interaction software programs help pharmacists and health care teams in the prevention and recognition of drug-drug interactions and optimize safety and quality of care delivered in intensive care units.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When the US Preventive Services Task Force (USPSTF) in 2009 recommended against universal breast cancer screening with mammography in women aged 40 to 49 years, some scientists, radiologists, politicians, and patients strongly objected. The controversy has been called the "mammography wars." The latest chapter in these wars comes from the Swiss Medical Board, which is mandated by the Conference of Health Ministers of the Swiss Cantons, the Swiss Medical Association, and the Swiss Academy of Medical Sciences to conduct health technology assessments. In a February 2014 report, the Swiss Medical Board stated that new systematic mammography screening programs should not be introduced, irrespective of the age of the women, and that existing programs should be discontinued. The board's main argument was that the absolute reduction in breast cancer mortality was low and that the adverse consequences of the screening were substantial. The absolute risk reduction in breast cancer mortality has been estimated by the board at 0.16% for women screened during 6.2 years and followed-up over 13 years, based on the results of a recent Cochrane Review. The adverse consequences include falsepositive test results, overdiagnosis and overtreatment of patients, and high costs, including the expense of follow-up testing and procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biller-Andorno and Jüni (2014), in a widely debated commentary published in the May 22 issue of the New England Journal of Medicine, accept the concept that mammography every 2 years from age 50 can decrease breast cancer mortality by 20%, that is, from five to four deaths per 1000 women over a 10-year period. Both the absolute and the relative risk of breast cancer death may vary depending on the baseline mortality rates in various populations and on the impact of screening mammography in reducing breast cancer mortality, which may well vary around the 20% estimate adopted. We accept, therefore, that there are still uncertainties in the absolute and relative impact of mammography screening on breast cancer mortality, given the different study schemes and mammography intervals, the differences in populations, and the continuous improvements in technology (Warner, 2011; Independent UK Panel on Breast Cancer Screening, 2012). We also agree on the observation that mammography has an appreciable impact on breast cancer mortality (Bosetti et al., 2012), but clearly a much smaller one on total mortality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Literature on scoliosis screening is vast, however because of the observational nature of available data and methodological flaws, data interpretation is often complex, leading to incomplete and sometimes, somewhat misleading conclusions. The need to propose a set of methods for critical appraisal of the literature about scoliosis screening, a comprehensive summary and rating of the available evidence appeared essential. METHODS: To address these gaps, the study aims were: i) To propose a framework for the assessment of published studies on scoliosis screening effectiveness; ii) To suggest specific questions to be answered on screening effectiveness instead of trying to reach a global position for or against the programs; iii) To contextualize the knowledge through expert panel consultation and meaningful recommendations. The general methodological approach proceeds through the following steps: Elaboration of the conceptual framework; Formulation of the review questions; Identification of the criteria for the review; Selection of the studies; Critical assessment of the studies; Results synthesis; Formulation and grading of recommendations in response to the questions. This plan follows at best GRADE Group (Grades of Recommendation, Assessment, Development and Evaluation) requirements for systematic reviews, assessing quality of evidence and grading the strength of recommendations. CONCLUSIONS: In this article, the methods developed in support of this work are presented since they may be of some interest for similar reviews in scoliosis and orthopaedic fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Repeated Chlamydia trachomatis infections after treatment are common. One reason is reinfection from untreated partners in ongoing sexual partnerships. Mathematical models that are used to predict the impact of screening on reducing chlamydia prevalence often do not incorporate reinfection and might overestimate the expected impact. We describe a pair compartmental model that explicitly incorporates sexual partnership duration and reinfection. The pair model predicts a weaker impact of screening when compared directly with a model that does not accommodate partnerships. Effective management of sex partners to prevent reinfection might need to be strengthened in chlamydia control programs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An improved mammalian two-hybrid system designed for interaction trap screening is described in this paper. CV-1/EBNA-1 monkey kidney epithelial cells expressing Epstein–Barr virus nuclear antigen 1 (EBNA-1) were stably transfected with a reporter plasmid for GAL4-dependent expression of the green fluorescent protein (GFP). A resulting clone, GB133, expressed GFP strongly when transfected transiently with transcriptional activators fused to GAL4 DNA-binding domain with minimal background GFP expression. GB133 cells maintained plasmids containing the OriP Epstein–Barr virus replication origin that directs replication of plasmids in mammalian cells in the presence of the EBNA-1 protein. GB133 cells transfected stably with a model bait expressed GFP when further transfected transiently with an expression plasmid for a known positive prey. When the bait-expressing GB133 cells were transfected transiently with an OriP-containing expression plasmid for the positive prey together with excess amounts of empty vector, cells that received the positive prey were readily identified by green fluorescence in cell culture and eventually formed green fluorescent microcolonies, because the prey plasmid was maintained by the EBNA-1/Ori-P system. The green fluorescent microcolonies were harvested directly from the culture dishes under a fluorescence microscope, and total DNA was then prepared. Prey-encoding cDNA was recovered by PCR using primers annealing to the vector sequences flanking the insert-cloning site. This system should be useful in mammalian cells for efficient screening of cDNA libraries by two-hybrid interaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shipping list no.: 99-0282-P.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-08

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The European Guidelines specify a minimum of 5,000 screening cases to be read yearly by radiologists carrying out second reading in non-centralized programs. This professional requirement is difficult to reach and/or to implement in regional programs covering a sparse population with a high number of participating radiology units, so that alternative blind double reading strategies must be devised. OBJECTIVE: To evaluate the effect on breast cancer screening performances of two second reading strategies used in non-centralized, low-volume programs. METHODS: Reading performances in two Swiss regional breast cancer screening programs (cantons of Wallis and Vaud), covering female populations, aged 50-69, of about 31'000 and 72'000 inhabitants were computed and compared. Both programs had similar screening regimens and organizations, but differed with respect to second reading. One setting applied a selective strategy whereby only experienced radiologists performed second reading; the other elicited not to restrict second readers on the basis of their individual screening activity. Analysis included some 140,000 mammograms performed between 1999 and 2005. RESULTS: Overall, screening performances improved with increasing total volume of reading, albeit not in a linear fashion. Regardless of setting, radiologists attained a higher level of screening accuracy when performing second rather than first readings, and incident rather than prevalent screening cases. The effect of a selective, small group of second readers appeared to impact favorably on the false-positive rate and other indicators of screening quality. As the learning curve depends on the number of mammograms read, these distinct strategies may bear different outcome in the long run. Implications and practical issues for low-volume programs are discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To determine the incidence of interval cancers which occurred in the first 12 months after mammographic screening at a mammographic screening service. Design: Retrospective analysis of data obtained by crossmatching the screening Service and the New South Wales Central Cancer Registry databases. Setting: The Central & Eastern Sydney Service of BreastScreen NSW. Participants: Women aged 40-69 years at first screen, who attended for their first or second screen between 1 March 1988 and 31 December 1992. Main outcome measures: Interval-cancer rates per 10 000 screens and as a proportion of the underlying incidence of breast cancer (as estimated by the underlying rate in the total NSW population). Results: The 12-month interval-cancer incidence per 10 000 screens was 4.17 for the 40-49 years age group (95% confidence interval [CI], 1.35-9.73) and 4.64 for the 50-69 years age group (95% CI, 2.47-7.94). Proportional incidence rates were 30.1% for the 40-49 years age group (95% CI, 9.8-70.3) and 22% for the 50-69 years age group (95% CI, 11.7-37.7). There was no significant difference between the proportional incidence rate for the 50-69 years age group for the Central & Eastern Sydney Service and those of major successful overseas screening trials. Conclusion: Screening quality was acceptable and should result in a significant mortality reduction in the screened population. Given the small number of cancers involved, comparison of interval-cancer statistics of mammographic screening programs with trials requires age-specific or age-adjusted data, and consideration of confidence intervals of both program and trial data.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Screening programs, particularly the inclusion of specific orthoptic tests to detect visual abnormalities, varies among countries. This study aims to: 1) describes expert perception of issues related with children visual screening; 2) identify specific orthoptic tests to detect visual abnormalities in children visual screening.