861 resultados para IEEE 80215 Standards
Resumo:
Several countries have invested in technologies for Smart Grids. Among such protocols designed cover this area, highlights the DNP3 (Distributed Network Protocol version 3). Although the DNP3 be developed for operation over the serial interface, there is a trend in the literature to the use of other interfaces. The Zigbee wireless interface has become more popular in the industrial applications. In order to study the challenges of integrating of these two protocols, this article is presented the analysis of DNP3 protocol stack through state machines The encapsulation of DNP3 messages in P2P (point-to-point) ZigBee Network, may assist in the discovery and solution of failures of availability and security of this integration. The ultimate goal is to merge the features of DNP3 and Zigbee stacks, and display a solution that provides the benefits of wireless environment, without impairment of security required for Smart Grid applications.
Resumo:
IEEE 1451 Standard is intended to address the smart transducer interfacing problematic in network environments. Usually, proprietary hardware and software is a very efficient solution to in planent the IEEE 1451 normative, although can be expensive and inflexible. In contrast, the use of open and standardized tools for implementing the IEEE 1451 normative is proposed in this paper. Tools such as Java and Phyton programming languages, Linux, programmable logic technology, Personal Computer resources and Ethernet architecture were integrated in order to constructa network node based on the IEEE 1451 standards. The node can be applied in systems based on the client-server communication model The evaluation of the employed tools and expermental results are presented. © 2005 IEEE.
Resumo:
In recent years, there has been a growing interest in incorporating microgrids in electrical power networks. This is due to various advantages they present, particularly the possibility of working in either autonomous mode or grid connected, which makes them highly versatile structures for incorporating intermittent generation and energy storage. However, they pose safety issues in being able to support a local island in case of utility disconnection. Thus, in the event of an unintentional island situation, they should be able to detect the loss of mains and disconnect for self-protection and safety reasons. Most of the anti-islanding schemes are implemented within control of single generation devices, such as dc-ac inverters used with solar electric systems being incompatible with the concept of microgrids due to the variety and multiplicity of sources within the microgrid. In this paper, a passive islanding detection method based on the change of the 5th harmonic voltage magnitude at the point of common coupling between grid-connected and islanded modes of operation is presented. Hardware test results from the application of this approach to a laboratory scale microgrid are shown. The experimental results demonstrate the validity of the proposed method, in meeting the requirements of IEEE 1547 standards.
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2015
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores - Área de Especialização em Automação e Sistemas
Resumo:
Standards and specifícations to manage accessibility issues in e-learning
Resumo:
This work presents a triple-mode sigma-delta modulator for three wireless standards namely GSM/WCDMA and Bluetooth. A reconfigurable ADC has been used to meet the wide bandwidth and high dynamic range requirements of the multi-standard receivers with less power consumption. A highly linear sigma-delta ADC which has reduced sensitivity to circuit imperfections has been chosen in our design. This is particularly suitable for wide band applications where the oversampling ratio is low. Simulation results indicate that the modulator achieves a peak SNDR of 84/68/68 dB over a bandwidth of 0.2/3.84/1.5 MHz with an oversampling ratio 128/8/8 in GSM/WCDMA/Bluetooth modes respectively
Resumo:
The monitoring of patients performed in hospitals is usually done either in a manual or semiautomated way, where the members of the healthcare team must constantly visit the patients to ascertain the health condition in which they are. The adoption of this procedure, however, compromises the quality of the monitoring conducted since the shortage of physical and human resources in hospitals tends to overwhelm members of the healthcare team, preventing them from moving to patients with adequate frequency. Given this, many existing works in the literature specify alternatives aimed at improving this monitoring through the use of wireless networks. In these works, the network is only intended for data traffic generated by medical sensors and there is no possibility of it being allocated for the transmission of data from applications present in existing user stations in the hospital. However, in the case of hospital automation environments, this aspect is a negative point, considering that the data generated in such applications can be directly related to the patient monitoring conducted. Thus, this thesis defines Wi-Bio as a communication protocol aimed at the establishment of IEEE 802.11 networks for patient monitoring, capable of enabling the harmonious coexistence among the traffic generated by medical sensors and user stations. The formal specification and verification of Wi-Bio were made through the design and analysis of Petri net models. Its validation was performed through simulations with the Network Simulator 2 (NS2) tool. The simulations of NS2 were designed to portray a real patient monitoring environment corresponding to a floor of the nursing wards sector of the University Hospital Onofre Lopes (HUOL), located at Natal, Rio Grande do Norte. Moreover, in order to verify the feasibility of Wi-Bio in terms of wireless networks standards prevailing in the market, the testing scenario was also simulated under a perspective in which the network elements used the HCCA access mechanism described in the IEEE 802.11e amendment. The results confirmed the validity of the designed Petri nets and showed that Wi-Bio, in addition to presenting a superior performance compared to HCCA on most items analyzed, was also able to promote efficient integration between the data generated by medical sensors and user applications on the same wireless network
Resumo:
The paper explains the conceptual design of instrumentation that measures electric quantities defined in the trial-use Std. 1459-2000. It is shown how the Instantaneous-Space-Phasor (ISP) approach, based on α, β, 0 components, can be used to monitor electric energy flow, evaluate the utilization of transmission line and quantify the level of harmonic pollution injected by nonlinear loads.
Resumo:
This paper presents a NCAP embedded on DE2 kit with Nios II processor and uClinux to development of a network gateway with two interfaces, wireless (ZigBee) and wired (RS232) based on IEEE 1451. Both the communications, wireless and wired, were developed to be point-to-point and working with the same protocols, based on IEEE 1451.0-2007. The tests were made using a microcomputer, which through of browser was possible access the web page stored in the DE2 kit and send commands of control and monitoring to both TIMs (WTIM and STIM). The system describes a different form of development of the NCAP node to be applied in different environments with wired or wireless in the same node. © 2011 IEEE.
Resumo:
This work describes a hardware/software co-design system development, named IEEE 1451 platform, to be used in process automation. This platform intends to make easier the implementation of IEEE standards 1451.0, 1451.1, 1451.2 and 1451.5. The hardware was built using NIOS II processor resources on Alteras Cyclone II FPGA. The software was done using Java technology and C/C++ for the processors programming. This HW/SW system implements the IEEE 1451 based on a control module and supervisory software for industrial automation. © 2011 Elsevier B.V.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Despite the acknowledged need of providing a personalized and adaptive learning process for all, current learning management systems do not properly cover personalization and accessibility issues and they are still struggling to support the reusability requirements coming from the pervasive usage of standards. There is a lack of frameworks for providing layered-based infrastructure covering the interoperability required to manage the whole range of standards, applications and services needed to meet accessibility and adaptations needs of lifelong learning services.