998 resultados para Hearing Sensitivity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses a study to determine the effect of carboplatin on hearing sensitivity in children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bone mineral density (BMD) may be associated with hearing loss in older adults. Demineralization of the cochlear capsule has been associated with hearing loss in those with Paget's disease of the bone and otosclerosis. Osteoporosis may also result in cochlear capsule demineralization. We hypothesized that lower hip BMD and lower heel ultrasound measurements would be associated with hearing loss in a population-based sample of 2,089 older black and white men and women. Bone parameters and hearing function were measured at the fourth clinical follow-up visit. Audiometric threshold testing was used to measure air- and bone-conduction hearing sensitivity. BMD of the hip and its subregions was measured using dual-energy X-ray absorptiometry. Calcaneal bone measurements [broadband ultrasound attenuation (BUA), speed of sound (SOS) and the quantitative ultrasound index (QUI)] were obtained using heel ultrasound. After adjusting for known hearing loss risk factors, no association was found between hearing and any of the bone measurements in whites and black women. In black men, however, lower hip BMD was associated with higher odds of hearing loss; for each standard deviation decrease in total hip BMD, the odds of hearing loss were 1.41 (95% confidence interval 1.08, 1.83), 1.39 (95% CI 1.07, 1.82) for femoral neck BMD and 1.65 (95% CI 1.26, 2.16) for trochanter BMD. Conductive hearing loss was associated with lower heel ultrasound measurements, though only among white men. The results of this study are mixed and inconclusive. Lower BMD of the hip and its subregions was associated with hearing loss among black men, but not among whites or black women. Lower measurements on heel ultrasound were associated with conductive hearing loss, though only among white men. These results suggest that axial and appendicular bone parameters may be modestly associated with hearing loss in older men, but not in women.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The present study explored illness perceptions of hearing difficulties amongst one hundred participants who reported experiencing hearing difficulties despite normal audiometric thresholds. This experience is referred to as King-Kopetzky syndrome (KKS), obscure auditory dysfunction (OAD), or auditory processing disorder (APD). Logistic regression was used to consider the associations between help-seeking and a range of audiological and illness perception measures. Results indicate that help-seekers present with poorer speech in noise thresholds than non help-seekers, and that coherent illness perceptions and a negative belief in the consequences of hearing difficulties are associated with help-seeking status, regardless of hearing sensitivity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Limited research is available on how well visual cues integrate with auditory cues to improve speech intelligibility in persons with visual impairments, such as cataracts. We investigated whether simulated cataracts interfered with participants’ ability to use visual cues to help disambiguate a spoken message in the presence of spoken background noise. We tested 21 young adults with normal visual acuity and hearing sensitivity. Speech intelligibility was tested under three conditions: auditory only with no visual input, auditory-visual with normal viewing, and auditory-visual with simulated cataracts. Central Institute for the Deaf (CID) Everyday Speech Sentences were spoken by a live talker, mimicking a pre-recorded audio track, in the presence of pre-recorded four-person background babble at a signal-to-noise ratio (SNR) of -13 dB. The talker was masked to the experimental conditions to control for experimenter bias. Relative to the normal vision condition, speech intelligibility was significantly poorer, [t (20) = 4.17, p < .01, Cohen’s d =1.0], in the simulated cataract condition. These results suggest that cataracts can interfere with speech perception, which may occur through a reduction in visual cues, less effective integration or a combination of the two effects. These novel findings contribute to our understanding of the association between two common sensory problems in adults: reduced contrast sensitivity associated with cataracts and reduced face-to-face communication in noise.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Rousettus aegyptiacus Geoffroy 1810 is a member of the only genus of Megachiropteran bats to use vocal echolocation, but the structure of its brief, click-like signal is poorly described. Although thought to have a simple echolocation system compared to that of Microchiroptera, R. aegyptiacus is capable of good obstacle avoidance using its impulse sonar. The energy content of the signal was at least an order of magnitude smaller than in Microchiropteran bats and dolphins (approximately 4 X 10(-8) J m(-2)). Measurement of the duration, amplitude and peak frequency demonstrate that the signals of this animal are broadly similar in structure and duration to those of dolphins. Gabor functions were used to model signals and to estimate signal parameters, and the quality of the Gabor function fit to the early part of the signal demonstrates that the echolocation signals of R. aegyptiacus match the minimum spectral spread for their duration and amplitude and are thus well matched to its best hearing sensitivity. However, the low energy content of the signals and short duration should make returning echoes difficult to detect. The performance of R. aegyptincus in obstacle avoidance experiments using echolocation therefore remains something of a conundrum.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper studies the relationship between hearing sensitivity and the presence of otoacoustic emissions by examining the variability of same ear emissions in a group of normal-hearing subjects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Emotion processing deficits can cause catastrophic damage to a person's ability to interact socially. While it is known that older adults have difficulty identifying facial emotions, it is still not clear whether this difficulty extends to identification of the emotion conveyed by prosody. This study investigated whether the ability of older adults to decode emotional prosody falls below that of young adults after controlling for loss of hearing sensitivity and key features of cognitive ageing. Apart from frontal lobe load, only verbal IQ was associated with the age-related reduction in performance displayed by older participants, but a notable deficit existed after controlling for its effects. It is concluded that older adults may indeed have difficulty deducing the emotion conveyed by prosody, and that while this difficulty can be exaggerated by some aspects of cognitive ageing, it is primary in origin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Frontonasal dysplasia (FND) is a rare malformative complex affecting the frontal portion of the face, the eyes and the nose; it may occur singly or associated with other clinical signs. No systematic studies describing hearing in this condition were found. AIM: To evaluate hearing sensitivity and sound stimulus conduction from cochlea to brainstem in patients with clinical signs of FND. METHODS: 21 patients with isolated or syndromic FND were submitted to a clinical (otological/vestibular antecedents and otoscopy) and instrumental (pure tone and speech audiometry, tympanometry and brainstem auditory evoked response) hearing evaluation. DESIGN: A clinical, cross-sectional observational prospective study. RESULTS: Hearing thresholds were normal in 15 (70%) patients, abnormal in 5 (25%), mostly with conductive hearing loss; one patient did not cooperate with testing. The tympanometric curve was type A in 30 (72%) ears, type C in 5 (12%), type As in 4 (9%) and type B in 3 (7%). The auditory brainstem response (ABR) showed no abnormalities. CONCLUSION: Patients with FND showed no abnormalities in the auditory system from cochlea to brainstem in this study. Mild conductive hearing loss found in some is probably related to cleft palate. Further evaluation of hearing pathways at higher levels is recommended.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper discusses a study to predict the pure tone audiogram from the results of electric response audiometry utilizing frequency-selective tone burst stimuli.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This dissertation examined whether a hearing impairment of the auditory end-organ has the same or a differential effect on the place and periodicity processes. Differential sensitivities for four normally hearing listeners and for both ears of five patients with unilateral Meniere’s disease were measured for tonal frequency and rate of sinusoidally amplitude-modulated noise at common frequencies and rates of the stimulus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background & objectives: There is a need to develop an affordable and reliable tool for hearing screening of neonates in resource constrained, medically underserved areas of developing nations. This study valuates a strategy of health worker based screening of neonates using a low cost mechanical calibrated noisemaker followed up with parental monitoring of age appropriate auditory milestones for detecting severe-profound hearing impairment in infants by 6 months of age. Methods: A trained health worker under the supervision of a qualified audiologist screened 425 neonates of whom 20 had confirmed severe-profound hearing impairment. Mechanical calibrated noisemakers of 50, 60, 70 and 80 dB (A) were used to elicit the behavioural responses. The parents of screened neonates were instructed to monitor the normal language and auditory milestones till 6 months of age. This strategy was validated against the reference standard consisting of a battery of tests - namely, auditory brain stem response (ABR), otoacoustic emissions (OAE) and behavioural assessment at 2 years of age. Bayesian prevalence weighted measures of screening were calculated. Results: The sensitivity and specificity was high with least false positive referrals for. 70 and 80 dB (A) noisemakers. All the noisemakers had 100 per cent negative predictive value. 70 and 80 dB (A) noisemakers had high positive likelihood ratios of 19 and 34, respectively. The probability differences for pre- and post- test positive was 43 and 58 for 70 and 80 dB (A) noisemakers, respectively. Interpretation & conclusions: In a controlled setting, health workers with primary education can be trained to use a mechanical calibrated noisemaker made of locally available material to reliably screen for severe-profound hearing loss in neonates. The monitoring of auditory responses could be done by informed parents. Multi-centre field trials of this strategy need to be carried out to examine the feasibility of community health care workers using it in resource constrained settings of developing nations to implement an effective national neonatal hearing screening programme.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses the use of tympanometric gradient, middle ear resonance and static admittance as diagnostic tools for testing the hearing of children and infants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the effectiveness of two screening methods (imitanciometry screening and questionnaire) to identify children at risk for conductive hearing loss, comparing this data with complete audiologic evaluation. Methods Of 507 children aged between three and six, 111 completed all procedures. The observational methods used were: imitanciometry screening, a questionnaire to identify risk factors for hearing loss and complete audiologic evaluation. Results obtained in the first two instruments were compared with results from complete audiologic evaluation (gold standard). From these comparisons, sensitivity and specificity, accuracy, positive and negative predictive values, and odds ratio were determined for the two screening methods and for the combination of both methods. Results The two methods applied in series (questionnaire and after imitanciometry screening) showed a greater odds ratio and better correlation between sensitivity and proportion of false-positives (ROC curve). Conclusion Combining the two tests in series improved screening accuracy. This combination was the best tool for identifying children at risk for conductive hearing loss.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes the prevalence of self-reported hearing loss in an elderly population in the city of Sao Paulo, Brazil, and associated factors, based on a cross-sectional descriptive and quantitative study. The sample consisted of individuals over 65 years of age selected from census tracts in two stages, with replacement and probability proportional to the population 75 years of age or older. Statistical analysis used Stata 10 with weighted data, Rao-Scott test, and backward stepwise Poisson regression. 1,115 elders were interviewed. Prevalence of self-reported hearing loss was 30.4%, and higher levels were associated with age over 75 years, male gender, self-reported musculoskeletal conditions, dizziness, visual impairment, and difficulty using the telephone. Increased knowledge of factors associated with hearing loss would support public policies on hearing. The high prevalence found in this study underlines the importance of addressing this issue among the elderly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. Aim: To evaluate the TS audiometer for conducting audiometric screening. Methods: A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. Results: For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. Conclusions: The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.