925 resultados para Fusión vertebral


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Determinar através de cortes tomográficos e reconstrução tridimensional a incidência de mal posicionamento de parafusos em pacientes submetidos ao tratamento cirúrgico da Escoliose idiopática do adolescente. MÉTODOS: Foram analisados exames tomográficos de 8 pacientes, tratados cirurgicamente no Hospital de Base de São José do Rio Preto-SP, realizada instrumentação posterior partindo de T2 /T4 a L4/L5 totalizando 164 parafusos. RESULTADOS: 32,9% (n=54) apresentavam posicionamento com risco potencial,ou seja desvio acima de 2 milímetros, sendo 20,1% (n=33) com invasão lateral, 9,1% (n=15) com invasão medial, 3,6 %(n=6) com invasão anterior. Dos parafusos que ofereciam risco potencial a relação com aspecto da curva foi de 46% (n=25) na concavidade, 35% (n=19) na convexidade e 19% (n=10) em vértebras adjacentes a curva. CONCLUSÃO: Os limites de penetração aceitáveis, assim como os métodos de mensuração ainda não foram padronizados, a técnica free hand' mostrou-se segura, apesar da violação dos pedículos. A tomografia computadorizada pré-operatória, auxilia no planejamento cirúrgico e na redução das complicações.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Análise retrospectiva de prontuários de pacientes com instabilidade C1-C2 de causas traumáticas e não-traumáticas, submetidos à artrodese C1-C2. MÉTODOS: Foi realizada análise retrospectiva de prontuários de 20 pacientes do ambulatório de coluna do IOT-HCFMUSP com idades entre 7 e 83 anos (média de 43 anos), de ambos os sexos. Os parâmetros radiográficos para instabilidade foram baseados na medida do intervalo atlanto-axial superior a 3 mm em adultos e a 5 mm em crianças, utilizando-se medidas obtidas através de radiografia simples analisada no perfil. RESULTADOS: Foram operados 20 pacientes com instabilidade cervical alta, a maioria de origem traumática. A técnica cirúrgica mais utilizada foi a artrodese descrita por Magerl. Não foram observadas lesões vasculares. Foi registrada complicação infecciosa em dois pacientes. Obteve-se uma taxa de consolidação da artrodese de 85% e não foram necessárias cirurgias de revisão. CONCLUSÃO: Todas as técnicas utilizadas produziram a consolidação óssea satisfatória e foram excelentes para controlar a instabilidade atlanto-axial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Anterior vertebral stapling using a nitinol staple is one such treatment. Despite increasing interest in this technique, little is known about the effects on the spine following insertion, or the mechanism of action of the staple. The aims of this study were threefold; (1) to measure changes in the bending stiffness of a single motion segment following staple insertion, (2) to describe the forces that occur within the staple during spinal movement, and (3) to describe the anatomical changes that occur following staple insertion. Results suggest that staple insertion consistently decreased stiffness in all directions of motion. An explanation for the finding may be found in the outcomes of the strain gauge testing and micro-CT scan. The strain gauge testing showed that once inserted, the staple tips applied a baseline compressive force to the surrounding trabecular bone and vertebral end-plate. This finding would be consistent with the current belief that the clinical effect of the staples is via unilateral compression of the physis. Interestingly however, as each specimen progressed through the five cycles of each test, the baseline load on the staple tips gradually decreased, implying that the force at the staple tip-bone interface was decreasing. We believe that this was likely occurring as a result of structural damage to the trabecular bone and vertebral end-plate by the staple effectively causing ‘loosening’ of the staple. This hypothesis is further supported by the findings of the micro-CT scan. The pictures depict significant trabecular bone and physeal injury around the staple blades. These results suggest that the current hypothesis that stapling modulates growth through physeal compression may be incorrect, but rather the effect occurs through mechanical disruption of the vertebral growth plate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thoracoscopic instrumented anterior spinal fusion for adolescent idiopathic scoliosis (AIS) has clinical benefits that include reduced pulmonary morbidity, postoperative pain, and improved cosmesis. However, quantitative data on radiological improvement of vertebral rotation using this method is lacking. This study’s objectives were to measure preoperative and postoperative axial vertebral rotational deformity at the curve apex in endoscopically-treated anterior-instrumented scoliosis patients using CT, and assess the relevance of these findings to clinically measured chest wall rib hump deformity correction. This is the first quantitative CT study to confirm that endoscopic anterior instrumented fusion for AIS substantially improves axial vertebral body rotational deformity at the apex of the curve. The margin of correction of 43% compares favourably with historically published figures of 24% for patients with posterior all-hook-rod constructs. CT measurements correlated significantly to the clinical outcome of rib hump deformity correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Top screw pullout occurs when the screw is under too much axial force to remain secure in the vertebral body. In vitro biomechanical pullout tests are commonly done to find the maximum fixation strength of anterior vertebral body screws. Typically, pullout tests are done instantaneously where the screw is inserted and then pulled out immediately after insertion. However, bone is a viscoelastic material so it shows a time dependent stress and strain response. Because of this property, it was hypothesised that creep occurs in the vertebral trabecular bone due to the stress caused by the screw. The objective of this study was therefore to determine whether the axial pullout strength of anterior vertebral body screws used for scoliosis correction surgery changes with time after insertion. This study found that there is a possible relationship between pullout strength and time; however more testing is required as the sample numbers were quite small. The design of the screw is made with the knowledge of the strength it must obtain. This is important to prevent such occurrences as top screw pullout. If the pullout strength is indeed decreased due to creep, the design of the screw may need to be changed to withstand greater forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertebrplasty involved injecting cement into a fractured vertebra to provide stabilisation. There is clinical evidence to suggest however that vertebroplasty may be assocated with a higher risk of adjacent vertebral fracture; which may be due to the change in material properties of the post-procedure vertebra modifying the transmission of mechanical stresses to adjacent vertebrae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporosis is a disease characterized by low bone mass and micro-architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture. Osteoporosis affects over 200 million people worldwide, with an estimated 1.5 million fractures annually in the United States alone, and with attendant costs exceeding $10 billion dollars per annum. Osteoporosis reduces bone density through a series of structural changes to the honeycomb-like trabecular bone structure (micro-structure). The reduced bone density, coupled with the microstructural changes, results in significant loss of bone strength and increased fracture risk. Vertebral compression fractures are the most common type of osteoporotic fracture and are associated with pain, increased thoracic curvature, reduced mobility, and difficulty with self care. Surgical interventions, such as kyphoplasty or vertebroplasty, are used to treat osteoporotic vertebral fractures by restoring vertebral stability and alleviating pain. These minimally invasive procedures involve injecting bone cement into the fractured vertebrae. The techniques are still relatively new and while initial results are promising, with the procedures relieving pain in 70-95% of cases, medium-term investigations are now indicating an increased risk of adjacent level fracture following the procedure. With the aging population, understanding and treatment of osteoporosis is an increasingly important public health issue in developed Western countries. The aim of this study was to investigate the biomechanics of spinal osteoporosis and osteoporotic vertebral compression fractures by developing multi-scale computational, Finite Element (FE) models of both healthy and osteoporotic vertebral bodies. The multi-scale approach included the overall vertebral body anatomy, as well as a detailed representation of the internal trabecular microstructure. This novel, multi-scale approach overcame limitations of previous investigations by allowing simultaneous investigation of the mechanics of the trabecular micro-structure as well as overall vertebral body mechanics. The models were used to simulate the progression of osteoporosis, the effect of different loading conditions on vertebral strength and stiffness, and the effects of vertebroplasty on vertebral and trabecular mechanics. The model development process began with the development of an individual trabecular strut model using 3D beam elements, which was used as the building block for lattice-type, structural trabecular bone models, which were in turn incorporated into the vertebral body models. At each stage of model development, model predictions were compared to analytical solutions and in-vitro data from existing literature. The incremental process provided confidence in the predictions of each model before incorporation into the overall vertebral body model. The trabecular bone model, vertebral body model and vertebroplasty models were validated against in-vitro data from a series of compression tests performed using human cadaveric vertebral bodies. Firstly, trabecular bone samples were acquired and morphological parameters for each sample were measured using high resolution micro-computed tomography (CT). Apparent mechanical properties for each sample were then determined using uni-axial compression tests. Bone tissue properties were inversely determined using voxel-based FE models based on the micro-CT data. Specimen specific trabecular bone models were developed and the predicted apparent stiffness and strength were compared to the experimentally measured apparent stiffness and strength of the corresponding specimen. Following the trabecular specimen tests, a series of 12 whole cadaveric vertebrae were then divided into treated and non-treated groups and vertebroplasty performed on the specimens of the treated group. The vertebrae in both groups underwent clinical-CT scanning and destructive uniaxial compression testing. Specimen specific FE vertebral body models were developed and the predicted mechanical response compared to the experimentally measured responses. The validation process demonstrated that the multi-scale FE models comprising a lattice network of beam elements were able to accurately capture the failure mechanics of trabecular bone; and a trabecular core represented with beam elements enclosed in a layer of shell elements to represent the cortical shell was able to adequately represent the failure mechanics of intact vertebral bodies with varying degrees of osteoporosis. Following model development and validation, the models were used to investigate the effects of progressive osteoporosis on vertebral body mechanics and trabecular bone mechanics. These simulations showed that overall failure of the osteoporotic vertebral body is initiated by failure of the trabecular core, and the failure mechanism of the trabeculae varies with the progression of osteoporosis; from tissue yield in healthy trabecular bone, to failure due to instability (buckling) in osteoporotic bone with its thinner trabecular struts. The mechanical response of the vertebral body under load is highly dependent on the ability of the endplates to deform to transmit the load to the underlying trabecular bone. The ability of the endplate to evenly transfer the load through the core diminishes with osteoporosis. Investigation into the effect of different loading conditions on the vertebral body found that, because the trabecular bone structural changes which occur in osteoporosis result in a structure that is highly aligned with the loading direction, the vertebral body is consequently less able to withstand non-uniform loading states such as occurs in forward flexion. Changes in vertebral body loading due to disc degeneration were simulated, but proved to have little effect on osteoporotic vertebra mechanics. Conversely, differences in vertebral body loading between simulated invivo (uniform endplate pressure) and in-vitro conditions (where the vertebral endplates are rigidly cemented) had a dramatic effect on the predicted vertebral mechanics. This investigation suggested that in-vitro loading using bone cement potting of both endplates has major limitations in its ability to represent vertebral body mechanics in-vivo. And lastly, FE investigation into the biomechanical effect of vertebroplasty was performed. The results of this investigation demonstrated that the effect of vertebroplasty on overall vertebra mechanics is strongly governed by the cement distribution achieved within the trabecular core. In agreement with a recent study, the models predicted that vertebroplasty cement distributions which do not form one continuous mass which contacts both endplates have little effect on vertebral body stiffness or strength. In summary, this work presents the development of a novel, multi-scale Finite Element model of the osteoporotic vertebral body, which provides a powerful new tool for investigating the mechanics of osteoporotic vertebral compression fractures at the trabecular bone micro-structural level, and at the vertebral body level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Currently the treatment options for idiopathic scoliosis are observation, bracing and fusion. While brace treatment is non-invasive, and preserves the growth, motion, and function of the spine, it does not correct deformity and is only modestly successful in preventing curve progression. In adolescents who fail brace treatment, surgical treatment with an instrumented spinal fusion usually results in better deformity correction but is associated with substantially greater risk. Furthermore in younger patients requiring surgical treatment, fusion procedures are known to adversely effect the future growth of the chest and spine. Fusionless treatments have been developed to allow effective surgical treatment of patients with idiopathic scoliosis who are too young for fusion procedures. Anterior vertebral stapling is one such fusionless treatment which aims to modulate the growth of vertebra to allow correction of scoliosis whilst maintaining normal spinal motion The Mater Misericordiae Hospital in Brisbane has begun to use anterior vertebral stapling to treat patients with idiopathic scoliosis who are too young for fusion procedures. Currently the only staple approved for clinical use is manufactured by Medtronic Sofamor Danek (Memphis, TN). This thesis explains the biomechanical and anatomical changes that occur following anterior vertebral staple insertion using in vitro experiments performed on an immature bovine model. Currently there is a paucity of published information about anterior vertebral stapling so it is hoped that this project will provide information that will aid in our understanding of the clinical effects of staple insertion. The aims of this experimental study were threefold. The first phase was designed to determine the changes in the bending stiffness of the spine following staple insertion. The second phase was designed to measure the forces experienced by the staple during spinal movements. The third and final phase of testing was designed to describe the structural changes that occur to a vertebra as a consequence of staple insertion. The first phase of testing utilised a displacement controlled testing robot to compare the change in stiffness of a single spinal motion segment following staple insertion for the three basic spinal motions of flexion-extension, lateral bending, and axial rotation. For the second phase of testing strain gauges were attached to staples and used to measure staple forces during spinal movement. In the third and final phase the staples were removed and a testing specimen underwent micro-computed tomography (CT) scanning to describe the anatomical changes that occur following staple insertion. The displacement controlled testing showed that there was a significant decrease in bending stiffness in flexion, extension, lateral bending away from the staple, and axial rotation away from the staple following staple insertion. The strain gauge measurements showed that the greatest staple forces occurred in flexion and the least in extension. In addition, a reduction in the baseline staple compressive force was seen with successive loading cycles. Micro-CT scanning demonstrated that significant damage to the vertebral body and endplate occurred as a consequence of staple insertion. The clinical implications of this study are significant. Based on the findings of this project it is likely that the clinical effect of the anterior vertebral staple evaluated in this project is a consequence of growth plate damage (also called hemiepiphysiodesis) causing a partial growth arrest of the vertebra rather than simply compression of the growth plate. The surgical creation of a unilateral growth arrest is a well established treatment used in the management of congenital scoliosis but has not previously been considered for use in idiopathic scoliosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporotic spinal fractures are a major concern in ageing Western societies. This study develops a multi-scale finite element (FE) model of the osteoporotic lumbar vertebral body to study the mechanics of vertebral compression fracture at both the apparent (whole vertebral body) and micro-structural (internal trabecular bone core)levels. Model predictions were verified against experimental data, and found to provide a reasonably good representation of the mechanics of the osteoporotic vertebral body. This novel modelling methodology will allow detailed investigation of how trabecular bone loss in osteoporosis affects vertebral stiffness and strength in the lumbar spine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporosis is the most common bone disease. Low levels of oestrogens or testosterone are risk factors for primary osteoporosis. The most common cause of secondary osteoporosis is glucocorticoid treatment, but there are many other secondary causes of osteoporosis. Osteoporosis can be secondary to anti-oestrogen treatment for hormone-sensitive breast cancer and to androgen-deprivation therapy for prostate cancer. Zoledronic is the most potent bisphosphonate at inhibiting bone resorption. In osteoporosis, zoledronic acid increases bone mineral density for at least a year after a single intravenous administration. The efficacy and safety of extended release (once-yearly) zoledronic acid in the treatment of osteoporosis is reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Fusionless scoliosis surgery is an early-stage treatment for idiopathic scoliosis which claims potential advantages over current fusion-based surgical procedures. Anterior vertebral stapling using a shape memory alloy staple is one such approach. Despite increasing interest in this technique, little is known about the effects on the spine following insertion, or the mechanism of action of the staple. The purpose of this study was to investigate the biomechanical consequences of staple insertion in the anterior thoracic spine, using in vitro experiments on an immature bovine model. Methods: Individual calf spine thoracic motion segments were tested in flexion, extension, lateral bending and axial rotation. Changes in motion segment rotational stiffness following staple insertion were measured on a series of 14 specimens. Strain gauges were attached to three of the staples in the series to measure forces transmitted through the staple during loading. A micro-CT scan of a single specimen was performed after loading to qualitatively examine damage to the vertebral bone caused by the staple. Findings: Small but statistically significant decreases in bending stiffness occurred in flexion,extension, lateral bending away from the staple, and axial rotation away from the staple. Each strain-gauged staple showed a baseline compressive loading following insertion which was seen to gradually decrease during testing. Post-test micro-CT showed substantial bone and growth plate damage near the staple. Interpretation: Based on our findings it is possible that growth modulation following staple insertion is due to tissue damage rather than sustained mechanical compression of the motion segment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Endoscopic anterior scoliosis correction has been employed recently as a less invasive and level-sparing approach compared with open surgical techniques. We have previously demonstrated that during the two-year post-operative period, there was a mean loss of rib hump correction by 1.4 degrees. The purpose of this study was to determine whether intra- or inter-vertebral rotational deformity during the post-operative period could account for the loss of rib hump correction. Materials and Methods. Ten consecutive patients diagnosed with adolescent idiopathic scoliosis were treated with an endoscopic anterior scoliosis correction. Low-dose computed tomography scans of the instrumented segment were obtained post-operatively at 6 and 24 months following institutional ethical approval and patient consent. Three-dimensional multi-planar reconstruction software (Osirix Imaging Software, Pixmeo, Switzerland) was used to create axial slices of each vertebral level, corrected in both coronal and sagittal planes. Vertebral rotation was measured using Ho’s method for every available superior and inferior endplate at 6 and 24 months. Positive changes in rotation indicate a reduction and improvement in vertebral rotation. Intra-observer variability analysis was performed on a subgroup of images. Results. Mean change in rotation for vertebral endplates between 6 and 24 months post-operatively was -0.26˚ (range -3.5 to 4.9˚) within the fused segment and +1.26˚ (range -7.2 to 15.1˚) for the un-instrumented vertebrae above and below the fusion. Mean change in clinically measured rib hump for the 10 patients was -1.6˚ (range -3 to 0˚). The small change in rotation within the fused segment accounts for only 16.5% of the change in rib hump measured clinically whereas the change in rotation between the un-instrumented vertebrae above and below the construct accounts for 78.8%. There was no clear association between rib hump recurrence and intra- or inter-vertebral rotation in individual patients. Intra-rater variability was ± 3˚. Conclusions. Intra- and inter-vertebral rotation continues post-operatively both within the instrumented and un-instrumented segments of the immature spine. Rotation between the un-instrumented vertebrae above and below the fusion was +1.26˚, suggesting that the un-instrumented vertebrae improved and de-rotated slightly after surgery. This may play a role in rib hump recurrence, however this remains clinically insignificant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reduced SHOX gene expression has been demonstrated to be associated with all skeletal abnormalities in Turner syndrome, other than scoliosis (and kyphosis). There is evidence to suggest that Turner syndrome scoliosis is clinically and radiologically similar to idiopathic scoliosis, although the phenotypes are dissimilar. This pilot gene expression study used relative quantitative real-time PCR (qRT-PCR) of the SHOX (short stature on X) gene to determine whether it is expressed in vertebral body growth plates in idiopathic and congenital scoliosis. After vertebral growth plate dissection, tissue was examined histologically and RNA was extracted and its integrity was assessed using a Bio-Spec Mini, NanoDrop ND-1000 spectrophotometer and standard denaturing gel electrophoresis. Following cDNA synthesis, gene-specific optimization in a Corbett RotorGene 6000 real-time cycler was followed by qRT-PCR of vertebral tissue. Histological examination of vertebral samples confirmed that only growth plate was analyzed for gene expression. Cycling and melt curves were resolved in triplicate for all samples. SHOX abundance was demonstrated in congenital and idiopathic scoliosis vertebral body growth plates. SHOX expression was 11-fold greater in idiopathic compared to congenital (n = 3) scoliosis (p = 0.027). This study confirmed that SHOX was expressed in vertebral body growth plates, which implies that its expression may also be associated with the scoliosis (and kyphosis) of Turner syndrome. SHOX expression is reduced in Turner syndrome (short stature). In this study, increased SHOX expression was demonstrated in idiopathic scoliosis (tall stature) and congenital scoliosis.