978 resultados para Frequency characteristics
Resumo:
Measures of vocal intensity, frequency and harshness were compared for 19 hearing-impaired and 21 normal-hearing people over 60 years of age. Significantly greater comfortable intensity levels were found in the hearing-impaired group, but the other measures of frequency and harshness were not significantly different. A large proportion of the subjects in both groups reported a history of gastro-oesophageal reflux (GER), a condition associated with vocal fold pathology and hoarseness. Comparison of the GER and non-GER subjects on the measures of vocal function showed that the female GER speaker exhibited lower frequency on the vowel /u/ than the non-GER subjects. Clinicians need to be aware of the effect of highly prevalent disorders such as hearing impairment and GER on the voices of elderly speakers.
Resumo:
This report provides techniques and procedures for estimating the probable magnitude and frequency of floods at ungaged sites on Iowa streams. Physiographic characteristics were used to define the boundaries of five hydrologic regions. Regional regression equations that relate the size of the drainage area to flood magnitude are defined for estimating peak discharges having specified recurrence intervals of 2, 5, 10, 25, 50, and 100 years. Regional regression equations are applicable to sites on streams that have drainage areas ranging from 0.04 to 5,150 square miles provided that the streams are not affected significantly by regulation upstream from the sites and that the drainage areas upstream from the sites are not mostly urban areas. Flood-frequency characteristics for the mainstems of selected rivers are presented in graphs as a function of drainage area.
Resumo:
A novel technique to obtain optimum blind spatialprocessing for frequency diversity spread spectrum (FDSS) communicationsystems is introduced. The sufficient statistics for alinear combiner, which prove ineffective due to the interferers frequencycharacteristics, are modified to yield improved detectionunder partial jamming in the spectral domain. Robustness to partialtime jamming is achieved by extending the notion of replicasover the frequency axis to a repetition over the time variable. Analysisand simulations are provided, showing the advantages of usingFDSS with spatial diversity to combat the interference when it isconfined to a narrow frequency band or short time interval relativeto the desired signal extent in either domain.
Resumo:
The aim of this cohort study was to prospectively assess frequency, characteristics, and determinants of restless legs syndrome (RLS) in pregnancy and its impact on sleep.
Resumo:
The topic of this study was to evaluate state-dependent effects of diazepam on the frequency characteristics of 47-channel spontaneous EEG maps. A novel method, the FFT-Dipole-Approximation (Lehmann and Michel, 1990), was used to study effects on the strength and the topography of the maps in the different frequency bands. Map topography was characterized by the 3-dimensional location of the equivalent dipole source and map strength was defined as the spatial standard deviation (the Global Field Power) of the maps of each frequency point. The Global Field Power can be considered as a measure of the amount of energy produced by the system, while the source location gives an estimate of the center of gravity of all sources in the brain that were active at a certain frequency. State-dependency was studied by evaluating the drug effects before and after a continuous performance task of 25 min duration. Clear interactions between drug (diazepam vs. placebo) and time after drug intake (before and after the task) were found, especially in the inferior-superior location of the dipole sources. It supports the hypothesis that diazepam, like other drugs, has different effects on brain functions depending on the momentary functional state of the brain. In addition to the drug effects, clearly different source locations and Global Field Power were found for the different frequency bands, replicating earlier reports (Michel et al., 1992).
Resumo:
Gamma activity to stationary grating stimuli was studied non-invasively using MEG recordings in humans. Using a spatial filtering technique, we localized gamma activity to primary visual cortex. We tested the hypothesis that spatial frequency properties of visual stimuli may be related to the temporal frequency characteristics of the associated cortical responses. We devised a method to assess temporal frequency differences between stimulus-related responses that typically exhibit complex spectral shapes. We applied this methodology to either single-trial (induced) or time-averaged (evoked) responses in four frequency ranges (0-40, 20-60, 40-80 and 60-100 Hz) and two time windows (either the entire duration of stimulus presentation or the first second following stimulus onset). Our results suggest that stimuli of varying spatial frequency induce responses that exhibit significantly different temporal frequency characteristics. These effects were particularly accentuated for induced responses in the classical gamma frequency band (20-60 Hz) analyzed over the entire duration of stimulus presentation. Strikingly, examining the first second of the responses following stimulus onset resulted in significant loss in stimulus specificity, suggesting that late signal components contain functionally relevant information. These findings advocate a functional role of gamma activity in sensory representation. We suggest that stimulus specific frequency characteristics of MEG signals can be mapped to processes of neuronal synchronization within the framework of coupled dynamical systems.
Resumo:
The detection of seizure in the newborn is a critical aspect of neurological research. Current automatic detection techniques are difficult to assess due to the problems associated with acquiring and labelling newborn electroencephalogram (EEG) data. A realistic model for newborn EEG would allow confident development, assessment and comparison of these detection techniques. This paper presents a model for newborn EEG that accounts for its self-similar and non-stationary nature. The model consists of background and seizure sub-models. The newborn EEG background model is based on the short-time power spectrum with a time-varying power law. The relationship between the fractal dimension and the power law of a power spectrum is utilized for accurate estimation of the short-time power law exponent. The newborn EEG seizure model is based on a well-known time-frequency signal model. This model addresses all significant time-frequency characteristics of newborn EEG seizure which include; multiple components or harmonics, piecewise linear instantaneous frequency laws and harmonic amplitude modulation. Estimates of the parameters of both models are shown to be random and are modelled using the data from a total of 500 background epochs and 204 seizure epochs. The newborn EEG background and seizure models are validated against real newborn EEG data using the correlation coefficient. The results show that the output of the proposed models has a higher correlation with real newborn EEG than currently accepted models (a 10% and 38% improvement for background and seizure models, respectively).
Resumo:
Sustained atrial fibrillation (AF) is maintained by sites displaying high dominant frequency (DF). In patients (pts) with long-standing persistent AF (LS-pAF), their spatial distribution and the presence of a left-to-right atrial DF gradient remain poorly known. We hypothesized that the pre-ablation bi-atrial frequency characteristics of LS-pAF pts terminated within the left atrium (LT) are different from that of non terminated (NT) ones. Methods: 23 consecutive pts (59±7y, LS-pAF duration 19±12m) underwent stepwise catheter ablation (step-CA) consisting in pulmonary veins isolation, left atrial (LA) defragmentation, and right atrial (RA) ablations for non terminated AF. A quadripolar catheter (CAT) was placed into the RA appendage (RAA), a decapolar CAT into the coronary sinus (CS) and a duodecapolar CAT into the LA divided into 8 segments. For each segment, 20-sec of bipolar recording was acquired. The DF was defined as the largest peak in the power spectrum (3-15 Hz). The inter-atrial DF gradient was defined as the DF difference between LA and RA appendages. Results: LS-pAF was terminated in 83% (19/23) of the pts: 17 LT, 2 during RA ablation and 4 NT. The figure shows that before ablation bi-atrial DF values of LT pts are significantly lower than that of NT pts for each LA segment as well as for the RAA (p < 0.05). No significant LA-to-RA DF gradient was observed both for LT (0.3±0.5 Hz, p=ns) and NT (0.5±0.03 Hz, p=ns) pts. No significant difference in DF values was observed between LA segments. Conclusions: The lower DF of LT pts is suggestive of a higher organization within both atria compared to NT pts. Our findings suggest that low bi-atrial DF values, but not inter-atrial DF gradient, might be of interest for selecting LS-pAF candidates for sinus rhythm restoration by step-CA.
Resumo:
The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.
Resumo:
The aim of the present study was to develop a classifier able to discriminate between healthy controls and dyspeptic patients by analysis of their electrogastrograms. Fifty-six electrogastrograms were analyzed, corresponding to 42 dyspeptic patients and 14 healthy controls. The original signals were subsampled, filtered and divided into the pre-, post-, and prandial stages. A time-frequency transformation based on wavelets was used to extract the signal characteristics, and a special selection procedure based on correlation was used to reduce their number. The analysis was carried out by evaluating different neural network structures to classify the wavelet coefficients into two groups (healthy subjects and dyspeptic patients). The optimization process of the classifier led to a linear model. A dimension reduction that resulted in only 25% of uncorrelated electrogastrogram characteristics gave 24 inputs for the classifier. The prandial stage gave the most significant results. Under these conditions, the classifier achieved 78.6% sensitivity, 92.9% specificity, and an error of 17.9 ± 6% (with a 95% confidence level). These data show that it is possible to establish significant differences between patients and normal controls when time-frequency characteristics are extracted from an electrogastrogram, with an adequate component reduction, outperforming the results obtained with classical Fourier analysis. These findings can contribute to increasing our understanding of the pathophysiological mechanisms involved in functional dyspepsia and perhaps to improving the pharmacological treatment of functional dyspeptic patients.
Studies on the structural, electrical and magnetic properties of composites based on spinel ferrites
Resumo:
This thesis mainly deals with the preparation and studies on magnetic composites based on spinel ferrites prepared both chemically and mechanically. Rubber ferrite composites (RFC) are chosen because of their mouldability and flexibility and the ease with which the dielectric and magnetic properties can be manipulated to make them as useful devices. Natural rubber is chosen as the Matrix because of its local availability and possible value addition. Moreover, NR represents a typical unsaturated nonpolar matrix. The work can be thought of as two parts. Part l concentrates on the preparation and characterization of nanocomposites based on y-Fe203. Part 2 deals with the preparation and characterization of RFCs containing Nickel zinc ferrit In the present study magnetic nanocomposites have been prepared by ionexchange method and the preparation conditions have been optimized. The insitu incorporation of the magnetic component is carried out chemically. This method is selected as it is the easiest and simplest method for preparation of nanocomposite. Nanocomposite samples thus prepared were studied using VSM, Mossbauer spectroscopy, Iron content estimation, and ESR spectroscopy. For the preparation of RFCs, the filler material namely nickel zinc ferrite having the general formula Ni)_xZnxFez04, where x varies from 0 to 1 in steps of 0.2 have been prepared by the conventional ceramic techniques. The system of Nil_xZn"Fe204 is chosen because of their excellent high frequency characteristics. After characterization they are incorporated into the polymer matrix of natural rubber by mechanical method. The incorporation is done according to a specific recipe and for various Loadings of magnetic fillers and also for all compositions. The cure characteristics, magnetic properties and dielectric properties of these composites are evaluated. The ac electrical conductivity of both ceramic nickel zinc ferrites and rubber ferrite composites are also calculated using a simple relation. The results are correlated.
Resumo:
In a sigma-delta analog to digital (A/D) As most of the sigma-delta ADC applications require converter, the most computationally intensive block is decimation filters with linear phase characteristics, the decimation filter and its hardware implementation symmetric Finite Impulse Response (FIR) filters are may require millions of transistors. Since these widely used for implementation. But the number of FIR converters are now targeted for a portable application, filter coefficients will be quite large for implementing a a hardware efficient design is an implicit requirement. narrow band decimation filter. Implementing decimation In this effect, this paper presents a computationally filter in several stages reduces the total number of filter efficient polyphase implementation of non-recursive coefficients, and hence reduces the hardware complexity cascaded integrator comb (CIC) decimators for and power consumption [2]. Sigma-Delta Converters (SDCs). The SDCs are The first stage of decimation filter can be operating at high oversampling frequencies and hence implemented very efficiently using a cascade of integrators require large sampling rate conversions. The filtering and comb filters which do not require multiplication or and rate reduction are performed in several stages to coefficient storage. The remaining filtering is performed reduce hardware complexity and power dissipation. either in single stage or in two stages with more complex The CIC filters are widely adopted as the first stage of FIR or infinite impulse response (IIR) filters according to decimation due to its multiplier free structure. In this the requirements. The amount of passband aliasing or research, the performance of polyphase structure is imaging error can be brought within prescribed bounds by compared with the CICs using recursive and increasing the number of stages in the CIC filter. The non-recursive algorithms in terms of power, speed and width of the passband and the frequency characteristics area. This polyphase implementation offers high speed outside the passband are severely limited. So, CIC filters operation and low power consumption. The polyphase are used to make the transition between high and low implementation of 4th order CIC filter with a sampling rates. Conventional filters operating at low decimation factor of '64' and input word length of sampling rate are used to attain the required transition '4-bits' offers about 70% and 37% of power saving bandwidth and stopband attenuation. compared to the corresponding recursive and Several papers are available in literature that deals non-recursive implementations respectively. The same with different implementations of decimation filter polyphase CIC filter can operate about 7 times faster architecture for sigma-delta ADCs. Hogenauer has than the recursive and about 3.7 times faster than the described the design procedures for decimation and non-recursive CIC filters.
Resumo:
El Switch arterial se ha convertido en la primera opción quirúrgica en pacientes con Transposición de grandes arterias (DTGA). El objetivo de este estudio es presentar la experiencia de la Fundación Cardioinfantil desde el año 2003 hasta julio del 2011, y determinar los factores de riesgo asociados a bajo gasto y mortalidad. Materiales y métodos: Estudio de caso - cohorte. Se revisaron las historias clínicas de los pacientes para obtener la información de las variables. El análisis se realizó mediante métodos estándar para variables continuas y variables categóricas. Los casos y sus controles se compararon y solo las variables con valores de p < 0.05 se analizaron como factores de riesgo. Resultados: 58 pacientes operados. Mediana de edad 12 días (RIQ 7 - 34), El 70.7% (41/58) de los pacientes fueron hombres. La DTGA con septum integro fue la anomalía más frecuente 53,5% (31/58). La mortalidad fue 15,2% (9/58) y la frecuencia de bajo gasto fue 55,2% (32/58). Entre el grupo de controles y casos no hubo diferencias estadísticamente significativas entre las variables preoperatorias y la presencia de bajo gasto y muerte, excepto el tiempo prolongado de circulación extracorpórea que fue factor de riesgo independiente para mortalidad OR 1.1 IC 95% (1 1,2) p de 0.002, y para bajo gasto cardiaco el score de vasoactivos-inotrópicos elevado OR 1.2 IC 95% (1.1 1,4) p de 0.001. Conclusiones: La frecuencia de las características de los pacientes operados en nuestra población es similar a lo reportado en la literatura mundial, sin embargo los factores de riesgo para mortalidad y bajo gasto no tuvieron el mismo impacto en nuestra población excepto por el tiempo de circulación extracorpórea y el uso de inotrópicos.
Resumo:
Background: Inadvertent drilling on the ossicular chain is one of the causes of sensorineural hearing loss (HL) that may follow tympanomastoid surgery. A high-frequency HL is most frequently observed. It is speculated that the HL is a result of vibration of the ossicular chain resembling acoustic noise trauma. It is generally considered that using a large cutting burr is more likely to cause damage than a small diamond burr. Aim: The aim was to investigate the equivalent noise level and its frequency characteristics generated by drilling onto the short process of the incus in fresh human temporal bones. Methods and Materials: Five fresh cadaveric temporal bones were used. Stapes displacement was measured using laser Doppler vibrometry during short drilling episodes. Diamond. and cutting burrs of different diameters were used. The effect of the drilling on stapes footplate displacement was compared with that generated by an acoustic signal. The equivalent noise level (dB sound pressure level equivalent [SPL eq]) was thus calculated. Results: The equivalent noise levels generated ranged from 93 to 125 dB SPL eq. For a 1-mm cutting burr, the highest equivalent noise level was 108 dB SPL eq, whereas a 2.3-mm cutting burr produced a maximal level of 125 dB SPL eq. Diamond burrs generated less noise than their cutting counterparts, with a 2.3-mm diamond burr producing a highest equivalent noise level of 102, dB SPL eq. The energy of the noise increased at the higher end of the frequency spectrum, with a 2.3-mm cutting burr producing a noise level of 105 dB SPL eq at 1 kHz and 125 dB SPL eq at 8 kHz. In contrast, the same sized diamond burr produced 96 dB SPL eq at 1 kHz and 99 dB at 8 kHz. Conclusion:This study suggests that drilling on the ossicular chain can produce vibratory force that is analogous with noise levels known to produce acoustic trauma. For the same type of burr, the larger the diameter, the greater the vibratory force, and for the same size of burr, the cutting burr creates more vibratory force than the diamond burr. The cutting burr produces greater high-frequency than lower-frequency vibratory energy.
Resumo:
Hypothesis: The aim of this study was to measure the mass loading effect of an active middle-ear implant (the Vibrant Soundbridge) in cadaver temporal bones. Background: Implantable middle ear hearing devices such as Vibrant Soundbridge have been used as an alternative to conventional hearing aids for the rehabilitation of sensorineural hearing loss. Other than the obvious disadvantage of requiring implantation middle ear surgery, it also applies a direct weight on the ossicular chain which, in turn, may have an impact on residual hearing. Previous studies have shown that applying a mass directly on the ossicular chain has a damping effect on its response to sound. However, little has been done to investigate the magnitude and the frequency characteristics of the mass loading effect in devices such as the Vibrant Soundbridge. Methods: Five fresh cadaver temporal bones were used. The stapes displacement was measured using laser Doppler vibrometry before and after the placement of a Vibrant Sound-bridge floating mass transducer. The effects of mass and attachment site were compared with the unloaded response. Measurements were obtained at frequencies between 0.1 and 10 kHz and at acoustic input levels of 100 dB sound pressure level. Each temporal bone acted as its own control. Results: Placement of the floating mass transducer caused a reduction of the stapes displacement. There were variations between the bones. The change of the stapes displacement varied from 0 dB to 28 dB. The effect was more prominent at frequencies above 1,000 Hz. Placing the floating mass transducer close to the incudostapedial joint reduced the mass loading effect. Conclusion: The floating mass transducer produces a measurable reduction of the stapes displacement in the temporal bone model. The effect is more prominent at high frequencies.