16 resultados para Frameless
Resumo:
Abstract Objective: To evaluate three-dimensional translational setup errors and residual errors in image-guided radiosurgery, comparing frameless and frame-based techniques, using an anthropomorphic phantom. Materials and Methods: We initially used specific phantoms for the calibration and quality control of the image-guided system. For the hidden target test, we used an Alderson Radiation Therapy (ART)-210 anthropomorphic head phantom, into which we inserted four 5mm metal balls to simulate target treatment volumes. Computed tomography images were the taken with the head phantom properly positioned for frameless and frame-based radiosurgery. Results: For the frameless technique, the mean error magnitude was 0.22 ± 0.04 mm for setup errors and 0.14 ± 0.02 mm for residual errors, the combined uncertainty being 0.28 mm and 0.16 mm, respectively. For the frame-based technique, the mean error magnitude was 0.73 ± 0.14 mm for setup errors and 0.31 ± 0.04 mm for residual errors, the combined uncertainty being 1.15 mm and 0.63 mm, respectively. Conclusion: The mean values, standard deviations, and combined uncertainties showed no evidence of a significant differences between the two techniques when the head phantom ART-210 was used.
Resumo:
The accurate position of the ventricular catheter inside the frontal horn of the lateral ventricle is essential to prevent proximal failure in shunt surgery. For optimal placement, endoscopic- and image-guided techniques are available.
Resumo:
BACKGROUND Neuronavigation has become an intrinsic part of preoperative surgical planning and surgical procedures. However, many surgeons have the impression that accuracy decreases during surgery. OBJECTIVE To quantify the decrease of neuronavigation accuracy and identify possible origins, we performed a retrospective quality-control study. METHODS Between April and July 2011, a neuronavigation system was used in conjunction with a specially prepared head holder in 55 consecutive patients. Two different neuronavigation systems were investigated separately. Coregistration was performed with laser-surface matching, paired-point matching using skin fiducials, anatomic landmarks, or bone screws. The initial target registration error (TRE1) was measured using the nasion as the anatomic landmark. Then, after draping and during surgery, the accuracy was checked at predefined procedural landmark steps (Mayfield measurement point and bone measurement point), and deviations were recorded. RESULTS After initial coregistration, the mean (SD) TRE1 was 2.9 (3.3) mm. The TRE1 was significantly dependent on patient positioning, lesion localization, type of neuroimaging, and coregistration method. The following procedures decreased neuronavigation accuracy: attachment of surgical drapes (DTRE2 = 2.7 [1.7] mm), skin retractor attachment (DTRE3 = 1.2 [1.0] mm), craniotomy (DTRE3 = 1.0 [1.4] mm), and Halo ring installation (DTRE3 = 0.5 [0.5] mm). Surgery duration was a significant factor also; the overall DTRE was 1.3 [1.5] mm after 30 minutes and increased to 4.4 [1.8] mm after 5.5 hours of surgery. CONCLUSION After registration, there is an ongoing loss of neuronavigation accuracy. The major factors were draping, attachment of skin retractors, and duration of surgery. Surgeons should be aware of this silent loss of accuracy when using neuronavigation.
Resumo:
BACKGROUND: Tumor bed stereotactic radiosurgery (SRS) after resection of brain metastases is a new strategy to delay or avoid whole-brain irradiation (WBRT) and its associated toxicities. This retrospective study analyzes results of frameless image-guided linear accelerator (LINAC)-based SRS and stereotactic hypofractionated radiotherapy (SHRT) as adjuvant treatment without WBRT. MATERIALS AND METHODS: Between March 2009 and February 2012, 44 resection cavities in 42 patients were treated with SRS (23 cavities) or SHRT (21 cavities). All treatments were delivered using a stereotactic LINAC. All cavities were expanded by ≥ 2 mm in all directions to create the clinical target volume (CTV). RESULTS: The median planning target volume (PTV) for SRS was 11.1 cm(3). The median dose prescribed to the PTV margin for SRS was 17 Gy. Median PTV for SHRT was 22.3 cm(3). The fractionation schemes applied were: 4 fractions of 6 Gy (5 patients), 6 fractions of 4 Gy (6 patients) and 10 fractions of 4 Gy (10 patients). Median follow-up was 9.6 months. Local control (LC) rates after 6 and 12 months were 91 and 77 %, respectively. No statistically significant differences in LC rates between SRS and SHRT treatments were observed. Distant brain control (DBC) rates at 6 and 12 months were 61 and 33 %, respectively. Overall survival (OS) at 6 and 12 months was 87 and 63.5 %, respectively, with a median OS of 15.9 months. One patient treated by SRS showed symptoms of radionecrosis, which was confirmed histologically. CONCLUSION: Frameless image-guided LINAC-based adjuvant SRS and SHRT are effective and well tolerated local treatment strategies after resection of brain metastases in patients with oligometastatic disease.
Resumo:
Objectives: We compare the dose parameters between 3 different radiosurgery delivery techniques which may have an impact on cochlea function. Methods: Five patients with unilateral vestibular schwannoma (VS) were selected for this study. Planning procedure was carried out using the BrainLAB® iPlan planning system v. 4.5. For each patient three different planning techniques were used: dynamic arc (DA) with 5 arcs per plan, hybrid arc (HA) with 5 arcs per plan and IMRT with 8 fields per plan. For each technique, two plans were generated with different methods: with the first method (PTV coverage) it was the goal to fully cover the PTV with at least 12 Gy (normalization: 12 Gy covered 99% of the PTV) and with the second method (cochlea sparing) it was the goal to spare the cochlea (normalization: 12 Gy covers 50% of the PTV/V4Gy of cochlea lower than 1%). Plan evaluation was done considering target volume and coverage (conformity and homogeneity) and OAR constraints (mean (Dmean) and maximum dose (Dmax) to cochlea, Dmax to brainstem and cochlea). The total number of monitor units (MU) was analyzed. Results: The median tumor volume was 0.95 cm³ (range, 0.86-3 cm³). The median PTV was 1.44 cm³ (range, 1-3.5 cm³). The median distance between the tumor and the cochlea's modiulus was 2.7 mm (range, 1.8-6.3 mm). For the PTV coverage method, when we compared the cochlear dose in VS patients planned with DA, HA and IMRT, there were no significant differences in Dmax (p = 0.872) and in Dmean (p= 0.860). We found a significant correlation (p< 0.05) between the target volume and the cochlear Dmean for all plans with Pearson's coefficient correlation of 0.90, 0.92 and 0.94 for the DA, HA and IMRT techniques, respectively. For the cochlea sparing method, when we compared the cochlear dose in VS patients planned with DA, HA and IMRT, there were no significant differences in Dmax (p = 0.310) and in Dmean (p= 0.275). However, in this group the V4Gy of the ipsilateral cochlea represents less than 1%. When using the HA or IMRT technique, the homogeneity and conformity in the PTV, but also the number of MUs were increased in comparison to the DA technique. Conclusion: VS tumors that extend distally into the IAC had an equivalent sparing of cochlea with DA approach compared with the HA and IMRT techniques. Disclosure: No significant relationships.
Resumo:
Frameless toughened glass skylight to kitchen, supported by timber joists. Outdoor room on right, Iwan roof beyond.
Resumo:
Frameless toughened glass skylight to kitchen, supported by timber joists. Outdoor room on right, Iwan roof beyond.
Resumo:
OBJECTIVES: To simplify the practice of stereotactic surgery by using an original method, apparatus, and solid anatomic replica for trajectory planning and to validate the method and apparatus in a laboratory and clinical trial. METHODS: The patient is marked with fiducials and scanned by using computed tomography or magnetic resonance imaging. The three-dimensional data are converted to a format acceptable to stereolithography. Stereolithography uses a laser to polymerize photosensitive resin into a solid plastic model (biomodel). Stereolithography can replicate brood vessels, soft tissue, tumor, and bone accurately (
Resumo:
Introducción: En la práctica neuroquirurgica el uso de tornillos pediculares torácicos ha venido en aumento en el tratamiento de diferentes patologías de la espinales. Desde la descripción original, se confirma la adecuada canalización del trayecto mediante el uso del palpador, sin embargo la validez y seguridad de dicho instrumento es limitada y existe riesgo de complicaciones complejas. En este estudio se comprueba la seguridad y validez del uso del palpador para diagnosticar la integridad del trayecto pedicular torácico. Metodología: Se canalizaron pedículos torácicos en especímenes cadavéricos los cuales de manera aleatoria se clasificaron como normales (íntegros) o anormales (violados). Posteriormente cuatro cirujanos de columna, con diferentes grados de experticia, evaluaron el trayecto pedicular. Se realizaron estudios de concordancia obteniendo coeficiente Kappa, porcentaje total de precisión, sensibilidad, especificidad, VPP y VPN y el área bajo la curva ROC para determinar la precisión de la prueba. Resultados: La precisión y validez en el diagnostico del trayecto pedicular y localización del sitio de violación tienen relación directa con la experiencia y entrenamiento del cirujano, el evaluador con mayor experiencia obtuvo los mejores resultados. El uso del palpador tiene una buena precisión, área bajo la curva ROC 0.86, para el diagnostico de las lesiones pediculares. Discusión: La evaluación precisa del trayecto pedicular, presencia o ausencia de una violación, es dependiente del grado de experiencia del cirujano, adicionalmente la precisión diagnostica de la violación varía según la localización de esta.
Resumo:
BackgroundAnatomical differences between humans and domestic mammals preclude the use of reported stereotactic approaches to the brainstem in animals. In animals, brainstem biopsies are required both for histopathological diagnosis of neurological disorders and for research purposes. Sheep are used as a translational model for various types of brain disease and therefore a species-specific approach needs to be developed. The aim of the present study was to establish a minimally invasive, accurate and reproducible stereotactic approach to the brainstem of sheep, using the magnetic resonance imaging guided BrainsightTM frameless stereotactic system.ResultsA transoccipital transcerebellar approach with an entry point in the occipital bone above the vermis between the transverse sinus and the external occipital protuberance was chosen. This approach provided access to the target site in all heads. The overall mean needle placement error was 1.85¿±¿1.22 mm.ConclusionsThe developed transoccipital transcerebellar route is short, provides accurate access to the ovine caudal cranial fossa and is a promising approach to be assessed further in live animals.
Resumo:
PURPOSE The range of patient setup errors in six dimensions detected in clinical routine for cranial as well as for extracranial treatments, were analyzed while performing linear accelerator based stereotactic treatments with frameless patient setup systems. Additionally, the need for re-verification of the patient setup for situations where couch rotations are involved was analyzed for patients treated in the cranial region. METHODS AND MATERIALS A total of 2185 initial (i.e. after pre-positioning the patient with the infrared system but before image guidance) patient setup errors (1705 in the cranial and 480 in the extracranial region) obtained by using ExacTrac (BrainLAB AG, Feldkirchen, Germany) were analyzed. Additionally, the patient setup errors as a function of the couch rotation angle were obtained by analyzing 242 setup errors in the cranial region. Before the couch was rotated, the patient setup error was corrected at couch rotation angle 0° with the aid of image guidance and the six degrees of freedom (6DoF) couch. For both situations attainment rates for two different tolerances (tolerance A: ± 0.5mm, ± 0.5°; tolerance B: ± 1.0 mm, ± 1.0°) were calculated. RESULTS The mean (± one standard deviation) initial patient setup errors for the cranial cases were -0.24 ± 1.21°, -0.23 ± 0.91° and -0.03 ± 1.07° for the pitch, roll and couch rotation axes and 0.10 ± 1.17 mm, 0.10 ± 1.62 mm and 0.11 ± 1.29 mm for the lateral, longitudinal and vertical axes, respectively. Attainment rate (all six axes simultaneously) for tolerance A was 0.6% and 13.1% for tolerance B, respectively. For the extracranial cases the corresponding values were -0.21 ± 0.95°, -0.05 ± 1.08° and -0.14 ± 1.02° for the pitch, roll and couch rotation axes and 0.15 ± 1.77 mm, 0.62 ± 1.94 mm and -0.40 ± 2.15 mm for the lateral, longitudinal and vertical axes. Attainment rate (all six axes simultaneously) for tolerance A was 0.0% and 3.1% for tolerance B, respectively. After initial setup correction and rotation of the couch to treatment position a re-correction has to be performed in 77.4% of all cases to fulfill tolerance A and in 15.6% of all cases to fulfill tolerance B. CONCLUSION The analysis of the data shows that all six axes of a 6DoF couch are used extensively for patient setup in clinical routine. In order to fulfill high patient setup accuracies (e.g. for stereotactic treatments), a 6DoF couch is recommended. Moreover, re-verification of the patient setup after rotating the couch is required in clinical routine.