973 resultados para Forced-choice method
Resumo:
Sensory thresholds are often collected through ascending forced-choice methods. Group thresholds are important for comparing stimuli or populations; yet, the method has two problems. An individual may correctly guess the correct answer at any concentration step and might detect correctly at low concentrations but become adapted or fatigued at higher concentrations. The survival analysis method deals with both issues. Individual sequences of incorrect and correct answers are adjusted, taking into account the group performance at each concentration. The technique reduces the chance probability where there are consecutive correct answers. Adjusted sequences are submitted to survival analysis to determine group thresholds. The technique was applied to an aroma threshold and a taste threshold study. It resulted in group thresholds similar to ASTM or logarithmic regression procedures. Significant differences in taste thresholds between younger and older adults were determined. The approach provides a more robust technique over previous estimation methods.
Resumo:
[Abstract]
Resumo:
In most psychological tests and questionnaires, a test score is obtained bytaking the sum of the item scores. In virtually all cases where the test orquestionnaire contains multidimensional forced-choice items, this traditionalscoring method is also applied. We argue that the summation of scores obtained with multidimensional forced-choice items produces uninterpretabletest scores. Therefore, we propose three alternative scoring methods: a weakand a strict rank preserving scoring method, which both allow an ordinalinterpretation of test scores; and a ratio preserving scoring method, whichallows a proportional interpretation of test scores. Each proposed scoringmethod yields an index for each respondent indicating the degree to whichthe response pattern is inconsistent. Analysis of real data showed that withrespect to rank preservation, the weak and strict rank preserving methodresulted in lower inconsistency indices than the traditional scoring method;with respect to ratio preservation, the ratio preserving scoring method resulted in lower inconsistency indices than the traditional scoring method
Resumo:
In most psychological tests and questionnaires, a test score is obtained by taking the sum of the item scores. In virtually all cases where the test or questionnaire contains multidimensional forced-choice items, this traditional scoring method is also applied. We argue that the summation of scores obtained with multidimensional forced-choice items produces uninterpretable test scores. Therefore, we propose three alternative scoring methods: a weak and a strict rank preserving scoring method, which both allow an ordinal interpretation of test scores; and a ratio preserving scoring method, which allows a proportional interpretation of test scores. Each proposed scoring method yields an index for each respondent indicating the degree to which the response pattern is inconsistent. Analysis of real data showed that with respect to rank preservation, the weak and strict rank preserving method resulted in lower inconsistency indices than the traditional scoring method; with respect to ratio preservation, the ratio preserving scoring method resulted in lower inconsistency indices than the traditional scoring method
Resumo:
This paper characterizes and evaluates the potential of three commercial CT iterative reconstruction methods (ASIR?, VEO? and iDose(4 ()?())) for dose reduction and image quality improvement. We measured CT number accuracy, standard deviation (SD), noise power spectrum (NPS) and modulation transfer function (MTF) metrics on Catphan phantom images while five human observers performed four-alternative forced-choice (4AFC) experiments to assess the detectability of low- and high-contrast objects embedded in two pediatric phantoms. Results show that 40% and 100% ASIR as well as iDose(4) levels 3 and 6 do not affect CT number and strongly decrease image noise with relative SD constant in a large range of dose. However, while ASIR produces a shift of the NPS curve apex, less change is observed with iDose(4) with respect to FBP methods. With second-generation iterative reconstruction VEO, physical metrics are even further improved: SD decreased to 70.4% at 0.5 mGy and spatial resolution improved to 37% (MTF(50%)). 4AFC experiments show that few improvements in detection task performance are obtained with ASIR and iDose(4), whereas VEO makes excellent detections possible even at an ultra-low-dose (0.3 mGy), leading to a potential dose reduction of a factor 3 to 7 (67%-86%). In spite of its longer reconstruction time and the fact that clinical studies are still required to complete these results, VEO clearly confirms the tremendous potential of iterative reconstructions for dose reduction in CT and appears to be an important tool for patient follow-up, especially for pediatric patients where cumulative lifetime dose still remains high.
Resumo:
Resumen tomado de la publicaci??n
Resumo:
Motivated by a recently proposed biologically inspired face recognition approach, we investigated the relation between human behavior and a computational model based on Fourier-Bessel (FB) spatial patterns. We measured human recognition performance of FB filtered face images using an 8-alternative forced-choice method. Test stimuli were generated by converting the images from the spatial to the FB domain, filtering the resulting coefficients with a band-pass filter, and finally taking the inverse FB transformation of the filtered coefficients. The performance of the computational models was tested using a simulation of the psychophysical experiment. In the FB model, face images were first filtered by simulated V1- type neurons and later analyzed globally for their content of FB components. In general, there was a higher human contrast sensitivity to radially than to angularly filtered images, but both functions peaked at the 11.3-16 frequency interval. The FB-based model presented similar behavior with regard to peak position and relative sensitivity, but had a wider frequency band width and a narrower response range. The response pattern of two alternative models, based on local FB analysis and on raw luminance, strongly diverged from the human behavior patterns. These results suggest that human performance can be constrained by the type of information conveyed by polar patterns, and consequently that humans might use FB-like spatial patterns in face processing.
Resumo:
O objetivo deste estudo foi investigar o efeito do envelhecimento na sensibilidade a frequências angulares com luminância fotópica (42,6cd/m²). Foram mensuradas curvas de sensibilidade ao contraste em oito adultos jovens (20-29 anos) e oito idosos (60-70 anos) por meio do método psicofísico da escolha forçada. Todos os participantes estavam livres de doenças oculares identificáveis e tinham acuidade visual normal. Os resultados mostraram que o grupo de idosos apresentou alteração significante na faixa de frequências baixas e altas. Concluiu-se que o envelhecimento parece afetar o processamento de frequências angulares baixas e altas em condições de luminância fotópica.
Resumo:
O objetivo deste trabalho foi medir curvas de sensibilidade ao contraste de 10 crianças ouvintes e de 10 crianças com surdez pré-lingual, de 7 a 12 anos, utilizando frequências radiais circularmente concêntricas (FSCr) de 0,25-2,0 cpg em níveis baixos de luminância (0,7 cd/m²). Todos os participantes apresentavam acuidade visual normal e estavam livres de doenças oculares identificáveis. A FSCr foi medida com o método psicofísico da escolha forçada. Os resultados mostraram sensibilidade máxima na faixa de frequência radial de 0,25 cpg para os dois grupos. Os resultados mostraram ainda diferenças significantes entre as curvas de FSCr de crianças ouvintes e de crianças com surdez pré-lingual. Isto é, as crianças ouvintes precisaram de menos contraste do que as crianças surdas para detectar as frequências radiais. Esses resultados sugerem que, em níveis baixos de luminância, a FSCr das crianças ouvintes foi melhor do que a das crianças com surdez pré-lingual.
Resumo:
We measured human contrast sensitivity to radial frequencies modulated by cylindrical (Jo) and spherical (j o) Bessel profiles. We also measured responses to profiles of j o, j1, j2, j4, j8, and j16. Functions were measured three times by at least three of eight observers using a forced-choice method. The results conform to our expectations that sensitivity would be higher for cylindrical profiles. We also observed that contrast sensitivity is increased with the j n order for n greater than zero, having distinct orderly effects at the low and high frequency ends. For n = 0, 1, 2, and 4 sensitivity tended to occur around 0.8-1.0 cpd while for n = 8 and 16 it seemed to shift gradually to 0.8-3.0 cpd. We interpret these results as being consistent with the possibility that spatial frequency processing by the human visual system can be defined a priori in terms of polar coordinates and discuss its application to study face perception.
Resumo:
The aim of the present study was to measure contrast sensitivity curves for angular frequencies in the range between 2 and 96 cycles/360º in older human adult volunteers and to compare these measurements with the more usual contrast sensitivity functions for sine-wave gratings. All subjects were free of identifiable ocular disease and had normal acuity. We measured the contrast thresholds for young adults (N = 6; age range, 20-26 years) and older adults (N = 6; age range, 60-67 years) using the psychophysical forced-choice method. In this paradigm the volunteers had to choose the stimulus containing a test frequency at low contrast (e.g., either a sine-wave grating or an angular frequency stimulus), or another neutral stimulus at mean luminance (without any contrast). Older adults presented a loss in contrast sensitivity at high and medium angular frequencies compared to the young adults (i.e., from 8 to 96 cycles/360º). Contrary to expectation, contrast sensitivity at low angular frequencies, i.e., 2 and 4 cycles/360º, was better for the older group than for the younger group. On the other hand, contrast sensitivity for sine-wave gratings at 3 and 4 cpd was higher for young adults as expected. These results suggest age-related changes in the contrast sensitivity function for angular frequencies.
Resumo:
The objective of the present study was to determine contrast sensitivity curves of concentric circular patterns with radial frequencies of 0.25, 0.5, 1.0, 2.0, and 4.0 cycles per degree in young and older adult volunteers. These parameters were also compared with sensitivity contrasts for sine-wave gratings. All participants had normal acuity vision and were free of identifiable ocular illness. Contrast sensitivity was measured in 6 young adults aged 19 to 23 years and 6 older adults aged 60 to 69 years using the psychophysical forced-choice method. In this paradigm the volunteers had to decide which of two stimuli contained the above radial frequencies at low contrast levels. The other neutral stimulus was gray with homogeneous luminance. We detected a decline in contrast sensitivity for older adults at all radial frequencies compared to young adults. Also, contrast sensitivity for sine-wave gratings at all measured frequencies was better, as predicted, for all young adults. Maximum sensitivities in the radial frequency contrast sensitivity function and contrast sensitivity function occurred at 0.25 and 0.5 cycles per degree, respectively, for both young and older adults. These results suggest age-related changes in the contrast sensitivity function for concentric symmetrical stimuli.
Resumo:
Motivated by a recently proposed biologically inspired face recognition approach, we investigated the relation between human behavior and a computational model based on Fourier-Bessel (FB) spatial patterns. We measured human recognition performance of FB filtered face images using an 8-alternative forced-choice method. Test stimuli were generated by converting the images from the spatial to the FB domain, filtering the resulting coefficients with a band-pass filter, and finally taking the inverse FB transformation of the filtered coefficients. The performance of the computational models was tested using a simulation of the psychophysical experiment. In the FB model, face images were first filtered by simulated V1- type neurons and later analyzed globally for their content of FB components. In general, there was a higher human contrast sensitivity to radially than to angularly filtered images, but both functions peaked at the 11.3-16 frequency interval. The FB-based model presented similar behavior with regard to peak position and relative sensitivity, but had a wider frequency band width and a narrower response range. The response pattern of two alternative models, based on local FB analysis and on raw luminance, strongly diverged from the human behavior patterns. These results suggest that human performance can be constrained by the type of information conveyed by polar patterns, and consequently that humans might use FB-like spatial patterns in face processing.
Resumo:
The aim of this study was to assess contrast sensitivity for angular frequency stimuli as well as for sine-wave gratings in adults under the effect of acute ingestion of alcohol. We measured the contrast sensitivity function (CSF) for gratings of 0.25, 1.25, 2.5, 4, 10, and 20 cycles per degree of visual angle (cpd) as well as for angular frequency stimuli of 1, 2, 4, 24, 48, and 96 cycles/360°. Twenty adults free of ocular diseases, with normal or corrected-to-normal visual acuity, and no history of alcoholism were enrolled in two experimental groups: 1) no alcohol intake (control group) and 2) alcohol ingestion (experimental group). The average concentration of alcohol in the experimental group was set to about 0.08%. We used a paradigm involving a forced-choice method. Maximum sensitivity to contrast for sine-wave gratings in the two groups occurred at 4 cpd sine-wave gratings and at 24 and 48 cycles/360° for angular frequency stimuli. Significant changes in contrast sensitivity were observed after alcohol intake compared with the control condition at spatial frequency of 4 cpd and 1, 24, and 48 cycles/360° for angular frequency stimuli. Alcohol intake seems to affect the processing of sine-wave gratings at maximum sensitivity and at the low and high frequency ends for angular frequency stimuli, both under photopic luminance conditions.
Resumo:
We measured the effects of epilepsy on visual contrast sensitivity to linear and vertical sine-wave gratings. Sixteen female adults, aged 21 to 50 years, comprised the sample in this study, including eight adults with generalized tonic-clonic seizure-type epilepsy and eight age-matched controls without epilepsy. Contrast threshold was measured using a temporal two-alternative forced-choice binocular psychophysical method at a distance of 150 cm from the stimuli, with a mean luminance of 40.1 cd/m². A one-way analysis of variance (ANOVA) applied to the linear contrast threshold showed significant differences between groups (F[3,188] = 14.829; p < .05). Adults with epilepsy had higher contrast thresholds (1.45, 1.04, and 1.18 times for frequencies of 0.25, 2.0, and 8.0 cycles per degree of visual angle, respectively). The Tukey Honestly Significant Difference post hoc test showed significant differences (p < .05) for all of the tested spatial frequencies. The largest difference between groups was in the lowest spatial frequency. Therefore, epilepsy may cause more damage to the neural pathways that process low spatial frequencies. However, epilepsy probably alters both the magnocellular visual pathway, which processes low spatial frequencies, and the parvocellular visual pathway, which processes high spatial frequencies. The experimental group had lower visual contrast sensitivity to all tested spatial frequencies.