816 resultados para Fire tests


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design, construction and operation of the tunnels of M-30, the major ring road in the city of Madrid (Spain), represent a very interesting project in wich a wide variety of situations -geometrical, topographical, etc.- had to be covered, in variable conditions of traffic. For that reasons, the M-30 project is a remarkable technical challenge, which, after its completion, turned into an international reference. From the "design for safety" perspective, a holistic approach has been used to deal with new technologies, integration of systems and development of the procedures to reach the maximum level. However, one of the primary goals has been to achieve reasonable homogeneity characteristics which can permit operate a netword of tunels as one only infraestructure. In the case of the ventilation system the mentioned goals have implied innovative solutions and coordination efforts of great interest. Consequently, this paper describes the principal ideas underlying the conceptual solution developed focusing on the principal peculiarities of the project.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Between 2003 and 2007 an urban network or road tunnels with a total constructed tubes length of 45 km was built in the city of Madrid. This amazing engineering work, known as "Calle 30 Project" counted with different kinds of tunnel typologies and ventilation systems. Due to the length of the tunnels and the impact of the work itself, the tunnels were endowed with a great variety of installations to provide the maximum levels of safety both for users and the infrastructure includieng, in some parts of the tunnel, fixed fire fighting system based on water mist. Whithin this framework a large-scale programme of fire tests was planned to study different aspects related to fire safety in the tunnels including the phenomena of the interaction between ventilation and extinguishing system. In addition, these large scale fire tests allowed fire brigades of the city of Madrid an opportunity to define operational procedures for specific fire fighting in tunnels and evaluate the possibilities of fixed fire fighting systems. The tests were carried out in the Center of Experimentation "San pedro of Anes" which includes a 600 m tunnel with a removable false ceiling for reproducing different ceiling heights and ventilation conditions (transverse and longitudinal ones). Interesting conclusions on the interaction of ventilation and water mist systems were obtained but also on other aspects including performance of water mist system in terms of reduction of gas temperatures or visibility conditions. This paper presents a description of the test's programme carried out and some previous results obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Between 2003 and 2007 an urban network of road tunnels with a total constructed tubes length of 45 km was built in the city of Madrid. This amazing engineering work, known as “Calle30 Project” counted with different kinds of tunnel typologies and ventilation systems. Due to the length of the tunnels and the impact of the work itself, the tunnels were endowed with a great variety of installations to provide the maximum levels of safety both for users and the infrastructure including,in some parts of the tunnel, fixed fire fighting system based on water mist. Within this framework a large-scale campaign of fire tests were planned to study different aspects related to fire safety in the tunnels including the phenomena of the interaction between ventilation and extinction system. In addition, this large scale fire tests allowed fire brigades of the city of Madrid an opportunity to define operational procedures for specific fire fighting in tunnels and evaluate the possibilities of fixed fire fighting systems. The tests were carried out in the Center of Experimentation "San Pedro of Anes" which counts with a 600 m tunnel with a removable false ceiling for reproducing different ceiling heights and ventilation conditions (transverse and longitudinal ones). Interesting conclusions on the interaction of ventilation and water mist systems were obtained but also on other aspects including performance of water mist system in terms of reduction of gas temperatures or visibility conditions. This paper presents a description of the test’s campaign carried out and some previous results obtained.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work, particleboards manufactured with Oceanic Posidonia waste and bonded with cement are investigated. The particleboards are made with 3/1.5/0.5 parts of cement per part of Posidonia waste. The physical properties of bulk density, swelling, surface absorption, and dimensional changes due to relative humidity as well as the mechanical properties of modulus of elasticity, bending strength, surface soundness, perpendicular tensile strength and impact resistance are studied. In terms of the above properties, the best results were obtained for particleboards with high cement content and when the waste “leaves” are treated (crushed) before board fabrication, due to internal changes to the board structure under these conditions. Based on the results of fire tests, the particleboard is non-flammable without any fire-resistant treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Um incêndio é algo difícil de prever, assim como a sua consequência nos elementos de construção. Dessa forma, ao longo das últimas décadas, os elementos de construção têm sido alvo de diversos estudos a fim de avaliar os seus comportamentos quando solicitados em situação de incêndio. O International Building Code (IBC) descreve um método de cálculo analítico para a determinação da resistência ao fogo dos elementos da construção de acordo com os procedimentos de teste estabelecidos na ASTM E119 (Standard Test Methods for Fire Tests of Building Construction and Materials). Nesta dissertação foi feita uma análise desse método, que se mostrou inadequado para estimar a resistência ao fogo das alvenarias, sem função estrutural, de blocos cerâmicos e blocos de betão, uma vez que despreza qualquer efeito do ar no interior das mesmas. No seguimento desta análise, é apresentado um desenvolvimento do método descrito tendo em conta o efeito do ar. Depois de uma análise aos vários tipos de blocos cerâmicos e de betão com diferentes dimensões e geometrias foi possível obter uma relação entre a espessura equivalente de ar existente num bloco e a sua respectiva resistência ao fogo, de modo a serem obtidos os valores descritos na normalização existente. O efeito do ar mostrou ter uma maior influência na resistência ao fogo nas alvenarias constituídas por blocos cerâmicos de furação vertical, já que a sua geometria caracterizada por um elevado número de pequenos alvéolos contribui para o aumento do isolamento térmico, e consequentemente da sua resistência ao fogo. Nas alvenarias rebocadas os valores da resistência ao fogo aumentam cerca de 50%, quando revestidos com argamassa de cimento, e 70% quando revestidos com gesso, logo, o emprego de revestimentos representam uma boa alternativa para aumentar a resistência ao fogo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A Segurança Contra Incêndios em Edifícios representa uma parte importante nos projetos de engenharia, uma vez que tem de ser analisada e implementada desde o início da construção. O principal objetivo é oferecer confiança aos utilizadores dos edifícios, aos seus bens e sistemas, sempre de acordo com a lei. Em qualquer tipo de edifício é iminente a capacidade de, por diversos motivos e circunstâncias, se iniciar um incêndio. O que se pretende com toda a regulamentação e matéria sobre a Segurança Contra Incêndios em Edifícios é a aplicação de sistemas de deteção, prevenção e extinção de incêndios, conseguindo, deste modo, reduzir os seus efeitos negativos. Este relatório de estágio apresenta, de um modo geral, a importância da Segurança Contra Incêndios em Edifícios atualmente nas construções, quais as principais regras neste âmbito, bem como a apresentação de todos os equipamentos e sistemas que fazem parte dos sistemas de SCIE. O presente relatório culmina com a vertente prática que consiste na descrição de casos acompanhados durante os meses de estágio, vistorias efetuadas e ensaios de incêndio. Os fenómenos inerentes a um alarme de incêndio serão descritos e comprovados em situações reais de simulação.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ydinenergian tuottamisessa turvallisuus on tärkeää. Todennäköisyyspohjaisella riskianalyysillä voidaan arvioida turvallisuusvaatimusten täyttymistä eri tilanteissa. Tässä diplomityössä tarkastellaan todennäköisyyspohjaisen riskianalyysin käyttöä ydinvoimalaitoksen kaapelipalojen vaikutusten arvioinnissa. Työn tarkoituksena on omalta osaltaan edistää ydinvoimalaitosten kaapelipaloturvallisuuden parantamista. Työssä esitellään todennäköisyyspohjaisen riskianalyysin ja todennäköisyyspohjaisen paloanalyysin periaatteet sekä nykyiset kaapelipaloanalyysimenetelmät. Olemassa olevien menetelmien pohjalta kehitettiin menetelmä Olkiluoto 1 ja 2 laitosyksiköiden kaapelipaloturvallisuuden arviointiin. Työssä tarkastellaan myös maailmalla sattuneita kaapelipaloja sekä ydinvoimalaitosten palosimulointiin kehitettyä ohjelmistoa. Työssä kehitetty kaapelipaloanalyysi jakautuu kahteen päävaiheeseen: virtapiirien vika-analyysiin ja virtapiirivikojen todennäköisyysanalyysiin. Virtapiirien vika-analyysi käsittää kaapeleiden vikamoodien, virtapiirien vikaantumisluokkien sekä vikaantumisten vaikutuksien määrittämisen. Virtapiirivikojen todennäköisyysanalyysissä määritetään puolestaan vikaantumistodennäköisyydet kaapelipalokokeiden tulosten pohjalta. Kehitettyä analyysimenetelmää sovellettiin esimerkinomaisesti Olkiluoto 1 ja 2 laitosyksiköiden kahdelle eri huonetilalle. Tuloksena saatiin turvallisuudelle tärkeiden järjestelmien virtapiirien vikaantumismallit sekä niiden todennäköisyydet. Tulosten perusteella voidaan todeta, että työssä kehitetty kaapelipaloanalyysimenetelmä toimi hyvin. Tulevaisuudessa menetelmää on tarkoitus hyödyntää Olkiluoto 1 ja 2 -laitosyksiköiden kaapelipaloturvallisuuden arvioinnissa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Elevator landing doors are fire tested to measure their fire resistance. The objective of this master’s thesis was to create a method to evaluate the fire tests and the organizations that provide these testing services. The main focus area was in creating accurate evaluation criteria and weighting the criteria. The thesis was formed by first presenting the reader with the literature review of the closest related theories. The theories which were chosen were systematic decision making, supplier selection, and make or buy and outsourcing theories. In the empirical section the created process of evaluating fire testing is presented, with analysis of the current situation of fire testing processes and evaluation methods. Evaluating fire testing services required two types of criteria to be formed, technical criteria to evaluate the technical requirements, and service criteria to evaluate the organization which was offering the testing service. These criteria formed the core for the evaluation process which consisted of five different phases that were developed based on the literature review. The process was tested to create best practices and to make improvement proposals accordingly. Systematical process for evaluating fire testing helps to recognize the most important technical and service related aspects. The created criteria can be also used in future to benchmark and monitor the situation of fire testing. The results of the process can be used when deciding whether to outsource the service or to keep it in-house.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Safety is one of the major concerns of process safety engineers in most industrial facilities all over the world. To this scope, some events play an important role once the effect of their consequences can be assumed as totally undesirable. One of these events refers to the occurrence of a fire. Such event can result in catastrophic consequences for life, equipment, and continuity of activities or even leading to environmental damage. A fire protection equipment with low reliability means that this equipment are often unavailable and thus the risk of a fire increases. Maintenance of fire protection equipment is very important because this kind of systems is mostly in a dormant mode, which gives uncertainty about their operability when demanded in a real situation of fire. This article outlines the importance of tests, inspection, and maintenance operations in the context of a fire sprinkler system and proposes a methodology based on international standards and supported by test/inspection reports to correct the frequency of these actions according to the level of degradation of the components and regarding safety purposes. © 2015 American Institute of Chemical Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 27-year-old woman suffered from anaphylaxis after being stung by Solenopsis invicta ants while she was handling wood from South America. The patient reported no previous adverse reactions to stings by other hymenopteran species. Intradermal skin tests with hymenoptera venom (Vespula vulgaris, Polistes species, Apis melifera) were negative. Serum specific immunoglobulin (Ig) E yielded positive results for S invicta (5.28 kU/L) and negative results for A melifera, Ves v 5 and Pol a 5. Immunodetection assays showed the presence of serum IgE against the Sol i 2 allergen. The patient had probably been stung previously although inadvertently by red fire ants while she handled infested wood from South America, and precautionary measures are thus advisable when this material is to be handled. To our knowledge this is the first case of anaphylaxis from red fire ant stings reported in Europe.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RÉSUMÉ GRAND PUBLIC La complexité des sociétés d'insectes (telles que les abeilles, les termites ou les fourmis) a depuis longtemps fasciné l'Homme. Depuis le débfit du XIXème siècle, de nombreux travaux observationnels, comportementaux et théoriques leur on été consacrés afin de mieux les décrire et comprendre. L'avènement de la biologie moléculaire à la fin du XXèrne siècle a offert de nouveaux outils scientifiques pour identifier et étudier les gènes et molécules impliqués dans le développement et le comportement des êtres vivants. Alors que la majorité de ces études s'est focalisée sur des organismes de laboratoire tel que la mouche ou les nématodes, l'utilisation de ces outils est restée marginale jusqu'à présent dans l'étude des sociétés d'insectes. Lors de ma thèse, j'ai développé des outils moléculaires permettant de déterminer le niveau d'activité de zo,ooo gènes chez la fourmi de feu, Solenopsis invicta, ainsi qu'une base de données et un portail en ligne regroupant les informations relatives à l'étude génétique des fourmis: Fourmidable. J'ai ensuite utilisé ces outils dans le cadre d'une étude comportementale chez la fourmis S. invicta. Dans les sociétés d'insectes, une hiérarchie peut déterminer le statut reproducteur des individus. Suite à la mort d'un dominant, les subordonnés entrent en compétition en vue d'améliorer leur statut. Un tel phénomène se produit au sein des colonies de S. invicta contenant une unique reine mère, des milliers d'ouvrières et des centaines de reines vierges ailées. A la mort de la reine mère, un grand nombre de reines vierges tentent de la remplacer en arrachant leurs ailes et en activant leurs organes reproducteurs plutôt que de partir en vol nuptial. Ces tentatives sont le plus souvent arrêtées par les ouvrières qui exécutent la plupart de ces reines sur la base de signaux olfactifs produits lors de l'activation des organes reproducteurs. Afin de mieux comprendre les mécanismes moléculaires impliqués, j'ai étudié l'activité de gènes au sein des reines au début de ce processus. J'ai ainsi déterminé que des gènes impliqués dans communication olfactive, le développement des organes reproducteurs et la métabolisation de l'hormone juvénile sont activês à ce moment là. La vitesse à laquelle les reines perdent leurs ailes ainsi que les niveaux d'expression de gènes sont ensuite liés à leur probabilité de survie. ABSTRACT : Honeybees, termites and ants occupy the "pinnacle of social evolution" with societies of a complexity that rivals our own. Humans have long been fascinated by social insects, but studying them has been mostly limited to observational and behavioral experiments. The advent of molecular biology first made it possible to investigate the molecular-genetic basis of development in model systems such as the fruit fly Drosophila melarcogaster or the roundworm Caenorhabditis elegans and subsequently their behavior. Molecular and genomic tools are now becoming available for the study of social insects as well. To permit genomic research on the fire ant, Solenopsis invicta, we developed a cDNA microarray that can simultaneously determine the expression levels of approximately 1oooo genes. These genes were assembled and bioinformatically annotated using custom pipelines. The obtained data formed the cornerstones for Fourmidable, a web portal centralizing sequence, gene annotation and gene expression data as well as laboratory protocols for research on ants. In many animals living in groups the reproductive status of individuals is determined by their social status. In species with social hierarchies, the death of dominant individuals typically upheaves the social hierarchy and provides an opportunity for subordinate individuals to improve their social status. Such a phenomenon occurs in the monogyne form of S. invicta, where colonies typically contain a single wingless reproductive queen, thousands of workers and hundreds of winged non-reproductive virgin queens. Upon the death of the mother queen, many virgin queens shed their wings and initiate reproductive development instead of departing on a mating flight. Workers progressively execute almost all of them over the following weeks. The workers base their collective decision on pheromonal cues associated with the onset of reproductive development of the virgin queens which occurs after orphaning. We used the aforementioned tools to determine that genes putatively involved in processes including olfactory signaling, reproductive development and Juvenile Hormone metabolism are differentially expressed at the onset of competition. Additionally, we found that queens that initiate reproductive development faster and, to a certain extent, shed their wings faster after orphaning are more likely to become replacement queens. These results provide candidate genes that are putatively linked to competition outcome. To determine the extent to which specific genes affect different aspects of life in ant colonies, functional tests such as gene activation and silencing will still be required. We conclude by discussing some of the challenges and opportunities for molecular-genetic research on ants. RÉSUMÉ Les sociétés d'abeilles, de termites et de fourmis sont d'une complexité proche de celle de la nôtre et ont depuis longtemps fasciné l'Homme. Cependant, leur étude était jusqu'à présent limitée aux observations et expériences comportementales. L'avènement de la biologie moléculaire a d'abord rendu possible l'étude moléculaire et génétique du développement d'organismes modèles tels que la mouche Drosophila melanogaster ou le nématode Caenorhabditis elegans, puis dans un second temps de leur comportement. De telles études deviennent désormais possibles pour les insectes sociaux. Nous avons développé une puce à ADN permettant de déterminer simultanément les niveaux d'expression de 1oooo gènes de la fourmi de feu, Solenopsís invicta. Ces gènes ont été séquencés puis assemblés et annotés à l'aide de pipelines que nous avons développés. En se basant sur les informations obtenues, nous avons créé un portail web, Fourmidable. Ce portail vise à centraliser toutes les informations de séquence, d'annotation et d'expression de gènes, ainsi que les protocoles de laboratoire utilisés pour la recherche sur les fourmis. Par la suite, nous avons utilisé les outils développés pour étudier un aspect particulier de S. invicta. Chez les animaux grégaires, une hiérarchie sociale peut déterminer le statut reproducteur des individus. Suite à la mort d'un individu dominant, les individus subordonnés peuvent entrer en compétition en vue d'améliorer leur statut. Un tel phénomène se produit au sein des colonies monogynes de S. invicta, qui contiennent habituellement une unique reine mère, des milliers d'ouvrières et des centaines de reines vierges ailées. Suite à la mort de la reine mère, dominante, un grand nombre de reines vierges, subordonnées, perdent leurs ailes et activent leurs organes reproducteurs au lieu de partir en vol nuptial. Au cours des semaines suivantes, les ouvrières exécutent la plupart de ces reines sur la base de signaux olfactifs produits lors de l'activation des organes reproducteurs. Afin de mieux comprendre les mécanismes moléculaires impliqués, nous avons étudié l'expression de gènes au début de cette compétition. Nous avons identifié 297 gènes différemment exprimés, dont l'annotation indique qu'ils seraient impliqués dans des processus biologiques dont la communication olfactive, le développement des organes reproducteurs et la métabolisation de l'hormone juvénile. Par la suite, nous avons déterminé que la vitesse à laquelle les reines perdent leurs ailes en début de compétition ainsi que les niveaux d'expression de gènes sont corrélés à la probabilité de survie des reines. Nous concluons en discutant des opportunités offertes par la recherche génétique sur les fourmis ainsi que les défis qu'elle devra surmonter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Radiello Passive Air Sampler is one of the latest innovations developed for the sampling of pollutants in the air by passive headspace. It has been reported that its properties allow an enhanced sensitivity, reproducibility and adsorption capacity. It therefore appears to be of interest in the extraction of potential residues of ignitable liquids present in fire debris when arson is suspected. A theoretical approach and several laboratory tests have made it possible to precisely characterize in a forensic perspective the potential of the device in extracting and concentrating the vapors of ignitable liquids found in fire debris. Despite some advantages, the Radiello device appears to be less efficient than traditional axial symmetry samplers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the odorant binding proteins (OBPs) of the red imported fire ant, Solenopsis invicta, obtained from analyses of an EST library and separate 454 sequencing runs of two normalized cDNA libraries. We identified a total of 18 putative functional OBPs in this ant. A third of the fire ant OBPs are orthologs to honey bee OBPs. Another third of the OBPs belong to a lineage-specific expansion, which is a common feature of insect OBP evolution. Like other OBPs, the different fire ant OBPs share little sequence similarity (∼ 20%), rendering evolutionary analyses difficult. We discuss the resulting problems with sequence alignment, phylogenetic analysis, and tests of selection. As previously suggested, our results underscore the importance for careful exploration of the sensitivity to the effects of alignment methods for data comprising widely divergent sequences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fire is a major agent involved in landscape transformation and an indirect cause of changes in species composition. Responses to fire may vary greatly depending on life histories and functional traits of species. We have examined the taxonomic and functional responses to fire of eight taxonomic animal groups displaying a gradient of dietary and mobility patterns: Gastropoda, Heteroptera, Formicidae, Coleoptera, Araneae, Orthoptera, Reptilia and Aves. The fieldwork was conducted in a Mediterranean protected area on 3 sites (one unburnt and two burnt with different postfire management practices) with five replicates per site. We collected information from 4606 specimens from 274 animal species. Similarity in species composition and abundance between areas was measured by the Bray-Curtis index and ANOSIM, and comparisons between animal and plant responses by Mantel tests. We analyze whether groups with the highest percentage of omnivorous species, these species being more generalist in their dietary habits, show weak responses to fire (i.e. more similarity between burnt and unburnt areas), and independent responses to changes in vegetation. We also explore how mobility, i.e. dispersal ability, influences responses to fire. Our results demonstrate that differences in species composition and abundance between burnt and unburnt areas differed among groups. We found a tendency towards presenting lower differences between areas for groups with higher percentages of omnivorous species. Moreover, taxa with a higher percentage of omnivorous species had significantly more independent responses of changes in vegetation. High- (e.g. Aves) and low-mobility (e.g. Gastropoda) groups had the strongest responses to fire (higher R scores of the ANOSIM); however, we failed to find a significant general pattern with all the groups according to their mobility. Our results partially support the idea that functional traits underlie the response of organisms to environmental changes caused by fire.