992 resultados para Fire Extinguishing Systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Safety is one of the major concerns of process safety engineers in most industrial facilities all over the world. To this scope, some events play an important role once the effect of their consequences can be assumed as totally undesirable. One of these events refers to the occurrence of a fire. Such event can result in catastrophic consequences for life, equipment, and continuity of activities or even leading to environmental damage. A fire protection equipment with low reliability means that this equipment are often unavailable and thus the risk of a fire increases. Maintenance of fire protection equipment is very important because this kind of systems is mostly in a dormant mode, which gives uncertainty about their operability when demanded in a real situation of fire. This article outlines the importance of tests, inspection, and maintenance operations in the context of a fire sprinkler system and proposes a methodology based on international standards and supported by test/inspection reports to correct the frequency of these actions according to the level of degradation of the components and regarding safety purposes. © 2015 American Institute of Chemical Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper studied marketing of automatic fire suppression systems from the perspectives of customer value and institutions. The object of the study was research the special features of the sales and marketing of fire suppression systems, and find some practical applications for sales, and for lobbying of a new fire suppression technology. The theoretical background of the study was in the customer value literature and the theoretical concept of institutional entrepreneurship. The research was conducted as an electronic survey for three different groups of respondents; end customers, solution integrators, and re-sellers. From the answers was gathered generalisations about the customer value assessment and communication of the value related to the sales and marketing processes of the fire suppression systems. In addition, there was observed manners to receive information about the systems, and effects caused by institutions to the decision making of the different parties involved. The findings of the study support companies that are launching a new safety technology to the market focus their marketing, and help to understand institutional forces that are affecting to a safety related product.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"U.S. Atomic Energy Commission Contract AT(29-1)-1106."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente trabalho enquadra-se na temática de segurança contra incêndio em edifícios e consiste num estudo de caso de projeto de deteção e extinção de incêndio num Data Center. Os objetivos deste trabalho resumem-se à realização de um estudo sobre o estado da arte da extinção e deteção automática de incêndio, ao desenvolvimento de uma ferramenta de software de apoio a projetos de extinção por agentes gasosos, como também à realização de um estudo e uma análise da proteção contra incêndios em Data Centers. Por último foi efetuado um estudo de caso. São abordados os conceitos de fogo e de incêndio, em que um estudo teórico à temática foi desenvolvido, descrevendo de que forma pode o fogo ser originado e respetivas consequências. Os regulamentos nacionais relativos à Segurança Contra Incêndios em Edifícios (SCIE) são igualmente abordados, com especial foco nos Sistemas Automáticos de Deteção de Incêndio (SADI) e nos Sistemas Automáticos de Extinção de Incêndio (SAEI), as normas nacionais e internacionais relativas a esta temática também são mencionadas. Pelo facto de serem muito relevantes para o desenvolvimento deste trabalho, os sistemas de deteção de incêndio são exaustivamente abordados, mencionando características de equipamentos de deteção, técnicas mais utilizadas como também quais os aspetos a ter em consideração no dimensionamento de um SADI. Quanto aos meios de extinção de incêndio foram mencionados quais os mais utilizados atualmente, as suas vantagens e a que tipo de fogo se aplicam, com especial destaque para os SAEI com utilização de gases inertes, em que foi descrito como deve ser dimensionado um sistema deste tipo. Foi também efetuada a caracterização dos Data Centers para que seja possível entender quais as suas funcionalidades, a importância da sua existência e os aspetos gerais de uma proteção contra incêndio nestas instalações. Por último, um estudo de caso foi desenvolvido, um SADI foi projetado juntamente com um SAEI que utiliza azoto como gás de extinção. As escolhas e os sistemas escolhidos foram devidamente justificados, tendo em conta os regulamentos e normas em vigor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Even eight hours after a campfire has been extinguished with sand, it retains sufficient heat to cause a full-thickness burn with contact of one second. Because extinguishing with sand disguises the danger, this is a particular hazard for children. The only safe way to extinguish a campfire is with water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Between 2003 and 2007 an urban network or road tunnels with a total constructed tubes length of 45 km was built in the city of Madrid. This amazing engineering work, known as "Calle 30 Project" counted with different kinds of tunnel typologies and ventilation systems. Due to the length of the tunnels and the impact of the work itself, the tunnels were endowed with a great variety of installations to provide the maximum levels of safety both for users and the infrastructure includieng, in some parts of the tunnel, fixed fire fighting system based on water mist. Whithin this framework a large-scale programme of fire tests was planned to study different aspects related to fire safety in the tunnels including the phenomena of the interaction between ventilation and extinguishing system. In addition, these large scale fire tests allowed fire brigades of the city of Madrid an opportunity to define operational procedures for specific fire fighting in tunnels and evaluate the possibilities of fixed fire fighting systems. The tests were carried out in the Center of Experimentation "San pedro of Anes" which includes a 600 m tunnel with a removable false ceiling for reproducing different ceiling heights and ventilation conditions (transverse and longitudinal ones). Interesting conclusions on the interaction of ventilation and water mist systems were obtained but also on other aspects including performance of water mist system in terms of reduction of gas temperatures or visibility conditions. This paper presents a description of the test's programme carried out and some previous results obtained.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Valuable insights into mechanisms of community responses to environmental change can be gained by analysing in tandem the variation in functional and taxonomic composition along environmental gradients. We assess the changes in species and functional trait composition (i.e. dominant traits and functional diversity) of diverse bee communities in contrasting fire-driven systems in two climatic regions: Mediterranean (scrub habitats in Israel) and temperate (chestnut forests in southern Switzerland). In both climatic regions, there were shifts in species diversity and composition related to post-fire age. In the temperate region, functional composition responded markedly to fire; however, in the Mediterranean, the taxonomic response to fire was not matched by functional replacement. These results suggest that greater functional stability to fire in the Mediterranean is achieved by replacement of functionally similar species (i.e. functional redundancy) which dominate under different environmental conditions in the heterogeneous landscapes of the region. In contrast, the greater functional response in the temperate region was attributed to a more rapid post-fire vegetation recovery and shorter time-window when favourable habitat was available relative to the Mediterranean. Bee traits can be used to predict the functional responses of bee communities to environmental changes in habitats of conservation importance in different regions with distinct disturbance regimes. However, predictions cannot be generalized from one climatic region to another where distinct habitat configurations occur.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Between 2003 and 2007 an urban network of road tunnels with a total constructed tubes length of 45 km was built in the city of Madrid. This amazing engineering work, known as “Calle30 Project” counted with different kinds of tunnel typologies and ventilation systems. Due to the length of the tunnels and the impact of the work itself, the tunnels were endowed with a great variety of installations to provide the maximum levels of safety both for users and the infrastructure including,in some parts of the tunnel, fixed fire fighting system based on water mist. Within this framework a large-scale campaign of fire tests were planned to study different aspects related to fire safety in the tunnels including the phenomena of the interaction between ventilation and extinction system. In addition, this large scale fire tests allowed fire brigades of the city of Madrid an opportunity to define operational procedures for specific fire fighting in tunnels and evaluate the possibilities of fixed fire fighting systems. The tests were carried out in the Center of Experimentation "San Pedro of Anes" which counts with a 600 m tunnel with a removable false ceiling for reproducing different ceiling heights and ventilation conditions (transverse and longitudinal ones). Interesting conclusions on the interaction of ventilation and water mist systems were obtained but also on other aspects including performance of water mist system in terms of reduction of gas temperatures or visibility conditions. This paper presents a description of the test’s campaign carried out and some previous results obtained.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Un incendio en el interior de un almacén de pirotecnia puede provocar la iniciación más o menos simultánea de los artículos existentes en su interior, con su consecuente onda de choque potenciada por la presión de los propios gases generados en su interior. La finalidad de esta tesis doctoral consiste en analizar los fenómenos que se desarrollan como consecuencia de un incendio interior en los almacenes de pirotecnia y establecer posibles medidas eficaces de prevención y protección con objeto de reducir el riesgo de explosión.. Inicialmente se llevó a cabo un análisis del riesgo de explosión, evaluando las consecuencias en caso de producirse un fuego interior. Los resultados fueron catastróficos. Finalmente, y con objeto de minimizar la posibilidad de producirse un incendio en el interior de un almacén, se evaluaron diferentes sistemas de detección y extinción automática de incendios para almacenes pirotécnicos, realizándose pruebas a escala real. En particular, la presente tesis consta de los siguientes trabajos: 1) Evaluación de la sobrepresión generada por la explosión de artificios pirotécnicos en el interior de almacenes, mediante pruebas de explosión de artículos pirotécnicos, con el fin de evaluar las posibles consecuencias en caso de materializarse una explosión, y disponer de información que permita conocer el grado de resistencia de las estructuras de los almacenes, así como el diseño adecuado de las mismas para soportar los efectos de tales explosiones. 2) Evaluación del efecto de un incendio en el interior de un almacén de pirotecnia mediante pruebas a escala real, con el fin de evaluar la posibilidad de la iniciación simultánea de los artículos pirotécnicos almacenados en su interior, y su consecuente explosión, así como las consecuencias en caso de materializarse la explosión. 3) Análisis de sistemas de detección y extinción automática de incendios para almacenes de pirotecnia, mediante la realización de pruebas a escala real para verificar la eficiencia y eficacia de tales sistemas y agentes para sofocar un incendio pirotécnico de forma tal que se evite la posible explosión asociada. 4) Evaluación de nuevos agentes extintores utilizados en los sistemas de extinción automática de incendios, que actualmente se están utilizando en el sector pirotécnico nacional, mediante la realización de pruebas a escala real. Los resultados obtenidos han permitido al Ministerio de Industria, Energía y Turismo actualizar la reglamentación vigente aplicable (Instrucción Técnica Complementaria número 17 del Reglamento de artículos pirotécnicos y cartuchería, aprobado por el Real Decreto 563/2010, de 7 de mayo). ABSTRACT A fire inside a pyrotechnics magazine can cause the more or less simultaneous initiation of the stored articles, with the wave of shock that is produced promoted by the pressure of the gases generated in its interior. The purpose of this PhD thesis is to analyze the phenomena that develop as a result of a fire inside the pyrotechnics stores and establish possible effective prevention and protection measures to reduce the risk of explosionAn analysis of the risk of explosion and fire consequences in a pyrotechnic magazine, testing to real scale, was initially carried out. The results were catastrophic. Finally, and in order to minimize the possibility of a fire inside a pyrotechnic magazine, different systems of detection and automatic extinction of fires in pyrotechnic magazines were evaluated, testing to real scale. Particularly, this thesis has the following parts: 1) Evaluation of the pressure generated by the pyrotechnic explosion in a magazine, with explosión tests of pyrotechnic articles, in order to evaluate the possible consequences in case of materialize an explosion, and provide information to know the resistance grade of the magazine structures, as well as the right design of those to withstand the effects of such explosions. 2) Evaluation of the effect of a fire inside a pyrotechnic magazine by full-scale tests, in order to evaluate the possibility of simultaneous initiation of the pyrotechnic articles stored inside, and the resulting explosion, as well as the consequences in case of materialize an explosion. 3) Analysis and evaluation of detection and automatic fire extinguishing in pyrotechnic magazines, by full-scale tests in order to verify the efficiency and effectiveness of such systems and agents to quell a pyrotechnic fire and avoid the posible mass explosion. 4) Evaluation of new extinguishing agent used in automatic fire extinguishers, which are currently being used in the national fireworks industry, by full-scale tests. The results obtained have allowed the Ministry of Industry, Energy and Tourism, update the current regulation (Complementary Technical Instruction 17 of the Regulation of Pyrotecnic Articles and Ammunition, approved by the Royal Decree 563/2010, of May 7).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Esta es la búsqueda de respuestas a esa duda constante: De dónde venimos y que hemos ido dejando por el camino. ¿Está todo claro en este recorrido o hemos actuado por acumulación de errores heredados de procesos anteriores? Es la investigación a través del descubrimiento de nuestro pasado, de nuestros orígenes en materia de seguridad de protección contra incendios, y sobre todo de ejecución de una arquitectura pensada para ser recorrida con mayor seguridad y ser evacuada en un tiempo razonable. El trabajo investiga, a nivel nacional, la evolución de la sociedad y sus efectos sobre la manera de interpretar el problema de la seguridad contra incendios en los edificios. El interés fundamentalmente es poner en claro todos aquellos aspectos que afectan a la evacuación de las personas. Para ello se han estudiado los principales hitos de actuación, las preocupaciones principales surgidas en cada momento y las soluciones adoptadas. Se ha comprobado su aplicación o su demora hasta que se ha producido el siguiente gran suceso que ha motivado una nueva revisión de los procedimientos de diseño y control. En primer lugar, tratando de relacionar los incendios fundamentales que han influido en nuestra forma de abordar el problema en distintos momentos de la historia de España. En segundo lugar, haciendo un recorrido sobre la figura del arquitecto y su participación en los medios de control y legislación sobre la manera de intervenir en el servicio de incendios o de resolver los edificios en materia de protección contra incendios o evacuación de sus ocupantes. En definitiva, descubriendo los escritos de algunos especialistas, fundamentales para entender nuestra manera de abordar el problema de la protección en los edificios, a lo largo de la historia. Se ha revisado como se han producido los siniestros más importantes en teatros y otros locales públicos .Analizando la forma en que los arquitectos implicados han tratado de resolver las posibles deficiencias ante el riesgo. Se trata de la tipología edificatoria donde, por primera vez, surge la preocupación por adoptar medidas y procedimientos de seguridad en caso de incendio. Resultan locales con una importante siniestralidad, donde se desarrolla la principal actividad lúdica del momento, y que por el importante número de personas que albergan, son fuente de preocupación entre el público y las autoridades. Otras cuestiones en un tema tan amplio, que quedan simplemente esbozadas en este trabajo de investigación, son los procedimientos de los sistemas de extinción, la estructura organizativa de la ciudad, las primeras sociedades de seguros de incendios, la aparición de patentes a partir del desarrollo industrial del siglo XIX. Todo ello, con el hilo conductor de la reglamentación que se ha ido elaborando al respecto. Al principio, sobre espectáculos públicos, acotando el punto de partida en la materia de nuestra reglamentación. Anticipando sistemas constructivos y datos dimensionales de la evacuación. Llegados a mediados del siglo XX, abordando otros usos. Haciendo seguimiento de la modernización de los procesos edificatorios y la reglamentación sectorial. Recabando información de las organizaciones profesionales que comienzan a reclamar una coordinación nacional de los sistemas preventivos y que desemboca en el Proyecto de Reglamento de prevención contra el fuego que nunca será publicado. Toda esta etapa, plagada de documentos de carácter voluntario u obligatorio, local y nacional, van definiendo los criterios dimensionales con los que debe resolverse los elementos arquitectónicos susceptibles de servir para la evacuación. Se trata de una etapa intensa en documentación, cambiante, sujeta a los criterios que establecen los países del entorno más avanzados en la materia. Las dos últimas décadas del siglo, acotadas por la transición política y varios siniestros de graves consecuencias, definen el proceso normativo que culmina con el código técnico de la edificación que hoy conocemos. Es un periodo de aprendizaje y asimilación del capítulo de la seguridad, donde los métodos son variados. Donde la intencionalidad última es trasladar un sistema prescriptivo a un modelo prestacional propio de la madurez en el análisis del tema y en las corrientes de los países del entorno. ABSTRACT This is the search for answers to that constant question: Where do we come from and what have left along the way? Has everything been clear on this journey, or have we acted as a result of a collection of errors learned from prior processes? This has been research through exploration of our past, of our origins regarding fire protection safety, and, above all, of the endeavour to utilize architecture aimed at offering the highest level of safety and evacuation in a reasonable time. This project has researched society’s change nationwide and its effects on how to interpret the difficulty of fire protection safety in buildings. Its focus has fundamentally been to clarify those aspects that affect the evacuation of people. To this end, the main milestones of action, the principal concerns that have arisen at each step, and the solutions taken have all been studied. A check was performed on their application; or their delay until a significant event occurred that prompted a new revision of design and control procedures. Firstly, this was done by attempting to connect the main fires that have influenced how we handle the problem at different times in Spain’s history. Secondly, an examination was done on the figure of the architect and his participation in the means of control and legislation on how to intercede in fire services, or how the architect finds solutions for buildings in terms of fire protection, or the evacuation of their occupants. In short, the written works of certain specialists, who are essential to our understanding of how to deal with the problem of protection in buildings, were explored throughout history. A study was done on the most significant disasters in theatres and other public establishments. This was done by analysing the way the architects involved have aimed to solve possible points liable to risk. It is a classification of building where, for the first time, the concern arose to adopt safety measures and procedures in the event of fires. Public establishments with considerable accident rates emerged. Here the main entertainment activities of the time took place. These spaces were a source of worry among the public and authorities due to the high number of persons they accommodated. Other issues in such an extensive subject, which are only outlined in this research study, are procedures in extinguishing systems, the organizational structure of cities, the first fire insurance companies, and the appearance of patents after the industrial development of the 19th century. All of these aspects are joined by the common thread of regulations that have been created in this matter. At the beginning, these regulations were for public shows, thus defining the starting point for our regulations. This was done in anticipation of structural systems and size data of evacuations. With the arrival of the mid-20th century, different uses were addressed. A modernization of construction processes and the industry regulations were tracked. Information was gathered from professional organizations that began to demand a national coordination of prevention systems which led to the Regulation Project on fire prevention which will never be published. Throughout this stage, replete with voluntary and compulsory documents, both on the local and national level, the dimensional criteria to be used in the resolution of architectural elements open to use in evacuation were defined. This was a period that was filled with documentation, change, and subject to the criteria that the most advanced countries in the field established in this regard. The final two decades of the century, marked by political transition and several accidents with grave consequences, defined the regulation process that culminated with the building technical code known today. This was a period of learning and understanding in the chapter of safety, where the methods are varied. In this chapter, the ultimate goal is to insert a prescriptive-based standard into a performance-based code suitable for cultivated experience in analysis of the subject and the tendencies in countries dealing with this field.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The most common method of achieve the required fire resistance is by the use of passive fire protection systems, being intumescent coatings the fire protection material frequently used. These are usually considered thin film coatings as they are applied with a dry film thickness (DFT) between 0.3-3 [mm]. The required DFT is obtained by experimental fire resistance tests performed to assess the contribution of this reactive fire protection material to the steel member fire resistance. This tests are done after dry coating and a short time period of atmospheric conditioning, at constant temperature and humidity. As the coatings formulation is mainly made from polymeric basis compounds, it is expected that the environmental factors, such temperature, humidity and UV radiation (UVA and UVB) significantly affect the intumescent coating fire protection performance and its durability. This work presents a research study about the effects of aging on the fire protection performance of intumescent coatings. A commercial water based coating is submitted to an accelerated aging cycle, using a QUV Accelerated Weathering Tester. This tests aim to simulate 10 years of the coating natural aging. The coating durability is tested comparing the fire protection of small steel samples submitted to a radiant heat flux exposure from a cone calorimeter. In total, 28 tests were performed on intumescent coating protected steel specimens, of which 14 specimens were tested before the hydrothermal aging test and other 14 after accelerated aging. The experimental tests results of the steel temperature evolution shows that increasing the intumescent dry coating film thickness, the fire resistance time increases. After the accelerated aging cycles, the coating lose their ability to expand, resulting in an increase of the steel temperature of approximately 200 [ºC], compared to the samples without aging.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

As ligas com memória de forma Ni-Ti apresentam diversas características bastante úteis, das quais podemos realçar a sua elevada resistência à corrosão, às vibrações e geração de forças superiores quando comparadas com outros atuadores. Estas ligas apresentam diversas áreas de aplicabilidade em diferentes aéreas de pesquisa, como a metalomecânica, a robótica, aplicações espaciais, sendo mais relevante para este trabalho a sua aplicação em mecanismos de segurança para portas e acessos. Com este trabalho, pretendemos contribuir para uma forma eficaz de combate e contenção de incêndios em navios, através da apresentação de um mecanismo que vai permitir o corte de ventilação e isolamento no local do incêndio, permitindo criar uma fronteira de fumos que levará ao combate do incêndio por asfixia. O trabalho descreve um mecanismo idealizado com a utilização de ligas com memória de forma, que vai proceder à libertação de um flap, para isolamento da ventilação, na presença de temperatura proveniente do incêndio. Descreve também ensaios termomecânicos realizados, para determinação das características das molas e seu comportamento em determinadas situações chave. Para isto, irão ser utilizadas duas molas com diferentes gamas de temperatura, com o intuito de demonstrar a eficácia na utilização de diversos atuadores de ligas com memória de forma. Todos os testes foram feitos na presença de gamas de temperatura que se assemelham aos valores de atuação dos sistemas automáticos de extinção por água, pelo que os resultados obtidos, ilustram a verdadeira eficácia e utilidade do mecanismo, em casos reais.