996 resultados para Filling time


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Internet and new communication technologies are deeply affecting healthcare systems and the provision of care. The purpose of this article is to evaluate the possibility that cyberhealth, via the development of widespread easy access to wireless personal computers, tablets and smartphones, can effectively influence intake of medication and long-term medication adherence, which is a complex, difficult and dynamic behaviour to adopt and to sustain over time. Because of its novelty, the impact of cyberhealth on drug intake has not yet been well explored. Initial results have provided some evidence, but more research is needed to determine the impact of cyberhealth resources on long-term adherence and health outcomes, its user-friendliness and its adequacy in meeting e-patient needs. The purpose of such Internet-based interventions, which provide different levels of customisation, is not to take over the roles of healthcare providers; on the contrary, cyberhealth platforms should reinforce the alliance between healthcare providers and patients by filling time-gaps between visits and allowing patients to upload and/or share feedback material to be used during the visits. This shift, however, is not easily endorsed by healthcare providers, who must master new eHealth skills, but healthcare systems have a unique opportunity to invest in the Internet and to use this powerful tool to design the future of integrated care. Before this can occur, however, important issues must be addressed and resolved, for example ethical considerations, the scientific quality of programmes, reimbursement of activity, data security and the ownership of uploaded data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Synbranchus marmoratus is a facultative air-breathing fish, which uses its buccal cavity as well as its gills for air-breathing. S. marmoratus shows a very pronounced tachycardia when it surfaces to air-breathe. An elevation of heart rate decreases cardiac filling time and therefore may cause a decline in stroke volume (VS), but this can be compensated for by an increase in venous tone to maintain stroke volume. Thus, the study on S. marmoratus was undertaken to investigate how stroke volume and venous function are affected during air-breathing. To this end we measured cardiac output (Q), heart rate (fH), central venous blood pressure (PCV), mean circulatory filling pressure (MCFP), and dorsal aortic blood pressures (PDA) in S. marmoratus. Measurements were performed in aerated water (P-O2 > 130 mmHg), when the fish alternated between gill ventilation and prolonged periods of apnoeas, as well as during hypoxia (P-O2 <= 50 mmHg), when the fish changed from gill ventilation to air-breathing. Q increased significantly during gill ventilation compared to apnoea in aerated water through a significant increase in both fH and VS. PCV and MCFP also increased significantly. During hypoxia, when the animals surface to ventilate air, we found a marked rise in fH, PCV, MCFP, Q and VS, whereas PDA decreased significantly. Simultaneous increases in PCV and MCFP in aerated, as well as in hypoxic water, suggests that the venous system plays an important regulatory role for cardiac filling and VS in this species. In addition, we investigated adrenergic regulation of the venous system through bolus infusions of adrenergic agonists (adrenaline, phenylephrine and isoproterenol; 2 mu g kg(-1)). Adrenaline and phenylephrine caused a marked rise in PCV and MCFP, whereas isoproterenol led to a marked decrease in PCV, and tended to decrease MCFP. Thus, it is evident that stimulation of both alpha- and beta-adrenoreceptors affects venous tone in S. marmoratus.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The dental documentation or handbook is a collection of documents produced by the professional with diagnostic and therapeutical purpose where the inherent information to the buccal and general health of patients are registered. The register and proper filling of these documents, taking care of the ethical and legal requirements, provide to the dentist the possibility to contribute with justice in cases of human identification and makes of these documents an essential element of evidence in the ethical processes, administrative, civil and criminal against the dentists. Ahead of this fact, understanding such requirements and the importance of the dentist to register himself adequately, this research verified the knowledge of Natal (RN) City s dentists with relation to the elaboration of the dental handbook, investigating the concepts and the importance attributed to the handbook, identifying the documents more used and filed by these professionals, besides inquiring the legal value of filed documents and the filling time of these ones. The sample was constituted by 124 dentists, who had answered a questionnaire, after having been randomly selected ITom a list of professionals subscribed in the Dentistry Local Council/RN Section. The analysis of the results showed that majority of the participant citÍzens (52,3%) confers to the dental documentation the clinical importance, followed by the legal and forensic-dentistry importance; 59,3% of the searched professionals do not distinguish satisfactorily or they do not observe differences between the dental handbook and the clinical filing card, the X-rays, the dental certificates, the prescriptions, the directions and the receipts; between the documents of common use to clínical and specialist ones, the contract of rendering of services and term of ITee and cleared up consent are the documents less used by the professionals. It was still verified, that only 13,1% of the sample register the signature of the patients in the clinical filing card, making it more credibility to be presented in judgement. In the same way, copies of dental certificates and prescriptions evaluated and signed by the patients are filed respectively by only 13,5% and 9,4% ofthe searched professionals and 50% ofthe sample, keep these documents filed for an indeterminate period of time, that is, these professionals have the guard of the handbook and they do not intend to disdain it, although 85,5% of the sample does not recognize the real proprietor of the handbook. It is concluded that a great part of the dentists is unaware about the importance of the dental documentation, and neglect its elaboration, leaving themselves exposed to several kinds of penalties foreseen in the legislation

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente estudo investigou a aplicação de dois tipos de AnSBBR (reatores anaeróbio com biofilme e operados em batelada e batelada alimentada sequenciais: com recirculação da fase líquida e com agitação) para produção de biohidrogênio tratando água residuária sintética (a base de soro de leite e lactose, respectivamente). O AnSBBR com recirculação da fase líquida, que foi o estudo principal do presente trabalho, apresentou problemas na produção de hidrogênio utilizando soro de leite como substrato. Algumas alternativas, como adaptação da biomassa com substratos puros de degradação mais fácil, controle do pH em valores muito baixos e diferentes formas de inoculação foram testadas, entretanto, sem obtenção de sucesso. A solução do problema foi obtida ao refrigerar o meio de alimentação a 4ºC para evitar a fermentação no frasco de armazenamento, retirar a ureia e a suplementação de nutrientes, e realizar lavagens periódicas do material suporte para retirada de parte da biomassa. Dessa forma eliminaram-se indícios de produção de H2S por possível ação de bactérias redutoras de sulfato (BRS) e atingiu-se uma produção estável de hidrogênio sem, entretanto, eliminar completamento o metano, que foi produzido em baixas concentrações. Depois de atingida a estabilidade, investigou-se a influência da concentração afluente de substrato, do tempo de enchimento e da temperatura na produção de biohidrogênio no AnSBBR com recirculação da fase líquida tratando soro de leite. O estudo da concentração afluente apresentou um ponto ótimo para a concentração de 5400 mgDQO.L-1, atingindo valores de 0,80 mol H2.mol-1 lactose e de 660 mL H2.L-1.d-1. O estudo do tempo de enchimento apresentou resultados similares para as condições analisadas. Com relação à temperatura, os melhores resultados foram obtidos com a temperatura mais baixa testada de 15ºC (1,12 mol H2.mol lactose-1 e 1080 mL H2.L-1.d-1), sendo que na temperatura mais alta testada (45°C) não ocorreu produção de hidrogênio. Para o AnSBBR com agitação mecânica, que foi um estudado complementar realizado pelo fato da lactose ser o principal complemento do soro de leite, o desempenho do biorreator foi avaliado de acordo com influência conjunta do tempo de ciclo (tC – 2, 3 e 4 h), da concentração afluente (CSTA – 3600-5400 mgDQO.L-1) e da carga orgânica volumétrica aplicada (COAV – 9,3, 12,3, 13,9, 18,5 e 27,8 mgDQO.L-1.d-1). Foram obtidos excelentes resultados: consumos de carboidratos (lactose), com valores médios sempre acima de 90% e uma produção estável de biohidrogênio em todas as condições estudadas, com metano em baixas concentrações apenas na condição de maior COAV. A diminuição do tC apresentou tendência clara de melhora sobre o RMCRC,n (rendimento molar entre hidrogênio produzido e carboidrato removido) apenas para as condições com menor concentração CSTA, havendo uma relação direta entre CSTA, e RMCRC,n em todos os valores de tC, exceto para o tempo de ciclo de 3 h, exatamente onde ocorreu produção de metano. O melhor valor de RMCRC,n obtido na operação com lactose (1,65 mol H2.mol Carboidrato-1) foi superior aos obtidos em outros trabalhos utilizando a mesma configuração de reator e sacarose como substrato. As análises filogenéticas mostraram que a maioria dos clones analisados foi semelhante à Clostridium. Além destes, clones filogeneticamente semelhantes com a Família Lactobacilaceae, especificamente Lactobacillus rhamnosus foram observados em menor porcentagem no reator, assim como clones com sequências semelhantes a Acetobacter indonesiensis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Avaliou-se o desempenho do reator anaeróbio em batelada seqüencial com biomassa imobilizada (ASBBR) no tratamento de soro de queijo quanto submetido a diferentes estratégias de alimentação e cargas orgânicas volumétricas (COV). O reator operou com agitação mecânica através de impelidor do tipo hélice na rotação de 500 rpm. Um volume de 2 litros foi alimentado por ciclo com 1 litro de volume residual, totalizando 3 litros. O substrato utilizado foi soro de queijo desidratado reconstituído. Suplementou-se o sistema com NaHCO3 na razão de 50% NaHCO3/DQO. Foram testadas as seguintes COVs: 2, 4, 8 e 12 gDQO/l.d. Para ciclos de 8 horas e em cada COV, três estratégias de alimentação foram testadas: (a) operação em batelada com ciclo de 8 horas, (b) batelada alimentada de 2 horas (c) batelada alimentada de 4 horas. Na COV de 2 gDQO/l.d, a conversão de matéria orgânica como DQO em amostras filtradas foi de 92, 96 e 91% para as estratégias de alimentação (a), (b) e (c), respectivamente. Para a COV de 4 gDQO/l.d, o desempenho foi de 94, 97 e 93%, respectivamente. Para a COV de 8 gDQO/l.d houve redução nas eficiências de conversão a 83, 85 e 86%, respectivamente. O aumento da COV para 12 gDQO/l.d, resultou na redução em eficiências de 72, 73 e 81%, respectivamente. Os perfis durante os ciclos da concentração de ácidos voláteis totais mostraram que, apesar do aumento gradual com o tempo de enchimento aumentando, nenhuma diferença significativa foi detectada em termos dos seus valores máximos. Foi observada a redução de ácido propiônico como conseqüência do aumento do tempo de enchimento. Assim, para COV de 2 e 4 gDQO/l.d, a estratégia de alimentação (b) proporcionou maiores eficiências de conversão e estabilidade operacional, enquanto que este comportamento foi observado na estratégia de alimentação (c) para os valores de COV de 8 e 12 gDQO/l.d.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the quality of filling in main and lateral root canals performed with the McSpadden technique, regarding the time spent on the procedure and the type of gutta-percha employed. Fifty simulated root canals, made with six lateral canals placed two apiece in the cervical, middle and apical thirds of the root, were divided into 5 groups. Group A: McSpadden technique with conventional gutta-percha, performed with sufficient time for canal filling; Group B: McSpadden technique with conventional gutta-percha, performed in twice the mean time used in Group A; Group C: McSpadden technique with TP gutta-percha, performed with sufficient time for canal filling; Group D: McSpadden technique with TP gutta-percha, performed in twice the mean time used in Group C; Group E: lateral condensation technique. Images of the filled root canals were taken using a stereomicroscope and analyzed using the Leica QWIN Pro software for filling material flow, gutta-percha filling extension and sealer flow. Data were analyzed by analysis of variance (ANOVA) and Tukey test (p < 0.05). The best values of penetration in lateral canals in the middle third occurred in the groups where TP gutta-percha was used. However, in the apical third, group B showed the best values. Although a longer time of compactor use allows greater penetration of the filling material into the lateral canals, the presence of voids resulted in bad quality radiographic images, suggesting porosity. The best quality of filling material was observed in Group A (McSpadden technique with conventional Gutta-Percha, performed with sufficient time for root canal filling).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: The purpose of this study was to assess the efficacy of Er:YAG laser energy for composite resin removal and the influence of pulse repetition rate on the thermal alterations occurring during laser ablation. Materials and Methods: Composite resin filling was placed in cavities (1.0 mm deep) prepared in bovine teeth and the specimens were randomly assigned to five groups according to the technique used for composite filling removal. In group I (controls), the restorations were removed using a high-speed diamond bur. In the other groups, the composite fillings were removed using an Er: YAG laser with different pulse repetition rates: group 2-2 Hz; group 3-4 Hz; group 4-6 Hz; and group 5-10 Hz. The time required for complete removal of the restorative material and the temperature changes were recorded. Results: Temperature rise during composite resin removal with the Er: YAG laser occurred in the substrate underneath the restoration and was directly proportional to the increase in pulse repetition rate. None of the groups had a temperature increase during composite filling removal of more than 5.6 degrees C, which is considered the critical point above which irreversible thermal damage to the pulp may result. Regarding the time for composite filling removal, all the laser-ablated groups (except for group 5 [10 Hz]) required more time than the control group for complete elimination of the material from the cavity walls. Conclusion: Under the tested conditions, Er: YAG laser irradiation was efficient for composite resin ablation and did not cause a temperature increase above the limit considered safe for the pulp. Among the tested pulse repetition rates, 6 Hz produced minimal temperature change compared to the control group (high-speed bur), and allowed composite filling removal within a time period that is acceptable for clinical conditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: This ex vivo study evaluated the heat release, time required, and cleaning efficacy of MTwo (VDW, Munich, Germany) and ProTaper Universal Retreatment systems (Dentsply/Maillefer, Ballaigues, Switzerland) and hand instrumentation in the removal of filling material. Methods: Sixty single-rooted human teeth with a single straight canal were obturated with gutta-percha and zinc oxide and eugenol-based cement and randomly allocated to 3 groups (n = 20). After 30-day storage at 37 degrees C and 100% humidity, the root fillings were removed using ProTaper UR, MTwo R, or hand files. Heat release, time required, and cleaning efficacy data were analyzed statistically (analysis of variance and the Tukey test, alpha = 0.05). Results: None of the techniques removed the root fillings completely. Filling material removal with ProTaper UR was faster but caused more heat release. Mtwo R produced less heat release than the other techniques but was the least efficient in removing gutta-percha/sealer. Conclusions: ProTaper UR and MTwo R caused the greatest and lowest temperature increase on root surface, respectively; regardless of the type of instrument, more heat was released in the cervical third. Pro Taper UR needed less time to remove fillings than MTwo R. All techniques left filling debris in the root canals. (I Endod 2010;36:1870-1873)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to compare GPX instruments and hand files for gutta-percha removal. Study design. Fifty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 5 groups of 10 specimens each, according to the gutta-percha removal techniques: group 1: GPX (21-mm-long teeth); group 2: GPX and xylol as solvent (21-mm-long teeth); group 3: GPX (25-mm-long teeth); group 4: GPX and xylol as solvent (25-mm-long teeth); and group 5: hand files and xylol as solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken, and the teeth were grooved longitudinally and split. The area of residual debris was measured using Sigma Scan software. Results. The time for filling material removal was significantly shorter when GPX was used (P < .05). Overall, hand files and solvent produced fewer remnants of filling materials (P < .05). In the GPX 25 mm-long teeth group, the filling material was not removed in the apical third. Conclusions. Under the experimental conditions, the GPX instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments left a smaller amount of residual filling materials on the canal walls. The GPX instruments did not pull the gutta-percha beyond its tip. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 675-680)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the pH, calcium release, setting time, and solubility of two commercially available mineral trioxide aggregate (MTA) cements (white MTA Angelus and MTA Bio), and of three experimental cements (light-cured MTA, Portland cement with 20% bismuth oxide and 5% calcium sulfate, and an epoxy resin-based cement). Study design. For evaluation of pH and calcium ion release, polyethylene tubes with 1.0 mm internal diameter and 10.0 mm length were filled with the cements and immediately immersed in flasks containing 10 mL deionized water. After 3, 24, 72, and 168 hours, the tubes were removed and the water from the previous container was measured for its pH and calcium content with a pH meter and an atomic absorption spectrophotometer. For analysis of the setting time, Gilmore needles weighing 100 g and 456.5 g were used, in accordance with the American Society for Testing and Materials specification no. C266-03. Solubility of each cement was also tested. Results. All the cements were alkaline and released calcium ions, with a declining trend over time. After 3 hours, Portland cement + bismuth oxide and MTA Bio had the highest pH and light-cured MTA the lowest. After 1 week, MTA Bio had the highest pH and light-cured MTA and epoxy resin-based cement the lowest. Regarding calcium ion release, after 3 hours, Portland cement + bismuth oxide showed the highest release. After 1 week, MTA Bio had the highest. Epoxy resin-based cement and light-cured MTA had the lowest calcium release in all evaluation periods. Regarding setting times, white MTA Angelus and MTA Bio had the shortest, Portland cement + bismuth oxide had an intermediate setting time, and the epoxy resin-based cement had the longest. The materials that showed the lowest solubility values were the epoxy resin-based cement, Portland cement + bismuth oxide, and light-cured MTA. The highest solubility values were presented in white MTA Angelus and MTA Bio. Conclusions. The white MTA Angelus and MTA Bio had the shortest setting times, higher pH and calcium ion release, and the highest solubility. In contrast, the epoxy resin-based cement and light-cured MTA showed lower values of solubility, pH, and calcium ion release. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 250-256)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to compare Profile .04 taper series 29 instruments and hand files for gutta-percha removal. Study design. Twenty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 2 groups of 10 specimens each, according to gutta-percha removal techniques: Group 1- Profile series 29 and Group 2- hand files and solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken and the teeth were grooved longitudinally and split. The area of residual debris was measured using computer software. Results. The time for filling material removal was significantly shorter when Profile series 29 was used (P = .00). Regarding cleanliness, there were no statistical differences in the teeth halves evaluations (P = .05). Hand instruments cleaned the canals significantly better than Profiles, in the radiographic analysis considering the whole canal. Overall, the radiographic analysis showed a smaller percentage of residual debris than the teeth halves analysis. Conclusion. The Profile series 29 instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments yielded better root canal cleanliness. Some residual debris was not visualized by radiographs. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e46-e50)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the influence of addition of 10% calcium chloride (CaCl(2)) on the setting time, solubility, disintegration, and pH of white MTA (WMTA) and white Portland cement (WPC). A test of the setting time was performed following the #57 ADA specifications and a test of the final setting time according to the ASTM. For the solubility tests disintegration and pH, Teflon rings were filled with the cements and weighed after setting. After 24 h in a desiccator, they were once again weighed. Thereafter, they were immersed in MiliQ water for 24 and 72 h and 7, 14, and 28 days, with maintenance in the desiccator and weighing between periods. The pH of water in which the rings were immersed was measured immediately after contact with them and in the other periods. The addition of CaCl(2) provided a significant reduction (50%) in the initial setting time of cements. The final setting time of WMTA was reduced in 35.5% and the final setting time of WPC in 68.5%. The WMTA with CaCl(2) absorbed water and gained weight with time, except for in the 24-h period. The addition of CaCl(2) to the WPC reduced its solubility. The addition of CaCl(2) increased the pH of WMTA in the immediate period and at 24 and 72 h and for WPC in the immediate period and at 24 h. The addition of CaCl(2) to WMTA and WPC reduced the setting times and solubility of both and increased the pH of cements in the initial periods. (J Endod 2009;35:550-554)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the influence of different endodontic materials on root fracture susceptibility. Methods: Seventy-two mandibular incisors were sectioned 1 mm below the cementoenamel junction to obtain roots of 12 mm length. Roots were submitted to chemomechanical preparation with the rotary instruments of Profile system. The obturation of root canals were performed with the following filling materials (n = 12): GI, unfilled teeth (control); GII, Endofill + gutta-percha; GIII, Sealer 26 + gutta-percha; GIV, AH Plus + gutta-percha; GV, Epiphany + gutta-percha; GVI, Epiphany + Resilon. After the sealers setting time, each root was embedded in acrylic resin. The specimens were then submitted to fracture resistance test using an Instron testing machine at 1 mm/min. Results: The ANOVA test showed no significant statistical difference (p > .05) among GI (162.16 +/- 41.4N), GII (168.46 +/- 37.5N), GIII (164.83 +/- 35.7N), GIV (168.29 +/- 38.7N), GV (172.36 +/- 20.6N) and GVI (193.11 +/- 42.8N). Conclusion: The core materials (gutta-percha or Resilon) combined with the tested endodontic sealers are not able to increase the root fracture resistance in canals submitted to chemomechanical preparation. (c) 2007 Elsevier Ltd. All rights reserved.