996 resultados para FUNDAMENTAL FREQUENCY
Resumo:
Considering that orthognathic surgery promotes changes in orofacial structures constituting the resonating system, functional changes secondary to surgery are expected to affect speech, leading to the need for further speech and voice adjustments. Thus, understanding the possible relationships of these structures with voice production is important. Therefore, this Study aimed to describe the changes in voice fundamental frequency of a patient submitted to orthognathic surgery and observe if there is a relationship with hyoid bone positioning at the different treatment periods. The results revealed that voice fundamental frequency increased after surgery, returning to values close to the preoperative condition, which corresponded to vertical movement of the hyoid bone.
Resumo:
This paper reviews a study to determine the usefulness of signal processing along with lipreading in improving speech perception of profoundly hearing impaired persons.
Resumo:
In an isolated syllable, a formant will tend to be segregated perceptually if its fundamental frequency (F0) differs from that of the other formants. This study explored whether similar results are found for sentences, and specifically whether differences in F0 (?F0) also influence across-formant grouping in circumstances where the exclusion or inclusion of the manipulated formant critically determines speech intelligibility. Three-formant (F1 + F2 + F3) analogues of almost continuously voiced natural sentences were synthesized using a monotonous glottal source (F0 = 150 Hz). Perceptual organization was probed by presenting stimuli dichotically (F1 + F2C + F3; F2), where F2C is a competitor for F2 that listeners must resist to optimize recognition. Competitors were created using time-reversed frequency and amplitude contours of F2, and F0 was manipulated (?F0 = ±8, ±2, or 0 semitones relative to the other formants). Adding F2C typically reduced intelligibility, and this reduction was greatest when ?F0 = 0. There was an additional effect of absolute F0 for F2C, such that competitor efficacy was greater for higher F0s. However, competitor efficacy was not due to energetic masking of F3 by F2C. The results are consistent with the proposal that a grouping “primitive” based on common F0 influences the fusion and segregation of concurrent formants in sentence perception.
Resumo:
This study explored the effects on speech intelligibility of across-formant differences in fundamental frequency (ΔF0) and F0 contour. Sentence-length speech analogues were presented dichotically (left=F1+F3; right=F2), either alone or—because competition usually reveals grouping cues most clearly—accompanied in the left ear by a competitor for F2 (F2C) that listeners must reject to optimize recognition. F2C was created by inverting the F2 frequency contour. In experiment 1, all left-ear formants shared the same constant F0 and ΔF0F2 was 0 or ±4 semitones. In experiment 2, all left-ear formants shared the natural F0 contour and that for F2 was natural, constant, exaggerated, or inverted. Adding F2C lowered keyword scores, presumably because of informational masking. The results for experiment 1 were complicated by effects associated with the direction of ΔF0F2; this problem was avoided in experiment 2 because all four F0 contours had the same geometric mean frequency. When the target formants were presented alone, scores were relatively high and did not depend on the F0F2 contour. F2C impact was greater when F2 had a different F0 contour from the other formants. This effect was a direct consequence of the associated ΔF0; the F0F2 contour per se did not influence competitor impact.
Resumo:
OBJETIVO: estudar o valor da freqüência fundamental e suas variações presentes no choro de dor de recém-nascidos. MÉTODOS: foram gravadas as emissões de 111 recém-nascidos de termo e saudáveis, com idade de 24 a 72 horas durante procedimento da punção venosa periférica. A análise acústica foi realizada por meio dos softwares VOXMETRIA 1.1 com extração do valor da freqüência fundamental e GRAM 5.7 para verificar a ocorrência de variações da freqüência fundamental como quebras, bitonalidade e freqüência hiperaguda. A escala de dor NIPS foi realizada no momento da punção. A análise estatística é descritiva com extração dos valores de média, desvio-padrão e freqüência de ocorrência dos eventos. RESULTADOS: os recém-nascidos apresentaram 100% de suas emissões com variações de freqüência, ou seja, quebras e bitonalidade. A freqüência hiperaguda foi encontrada em 34,2% dos recém-nascidos. CONCLUSÃO: por meio do choro, o recém-nascido comunica sua dor. A emissão de dor do recém-nascido é tensa e estridente, com freqüência fundamental aguda e variações encontradas no traçado espectrográfico, como quebras, bitonalidade e freqüência hiperaguda. Tais características são importantes para chamar a atenção do adulto no pronto atendimento ao recém-nascido e auxiliar na avaliação de dor durante um procedimento.
Resumo:
Considerando a crescente utilização de técnicas de processamento digital de sinais em aplicações de sistemas eletrônicos e ou de potência, este artigo discute o uso da Transformada Discreta de Fourier Recursiva (TDFR) para identificação do ângulo de fase, da freqüência e da amplitude das tensões fundamentais da rede, independente de distorções na forma de onda ou de transitórios na amplitude. Será discutido que, se a freqüência fundamental das tensões medidas coincide com a freqüência a qual a TDF foi projetada, um simples algoritmo TDFR é completamente capaz de fornecer as informações requeridas de fase, freqüência e amplitude. Dois algoritmos adicionais são propostos para garantir seu desempenho correto quando a freqüência difere do seu valor nominal: um deles para a correção do erro de fase do sinal de saída e outro para identificação da amplitude do componente fundamental. Além disto, destaca-se que através dos algoritmos propostos, independentemente do sinal de entrada, a identificação do componente fundamental pode ser realizada em, no máximo, 2 ciclos da rede. Uma análise dos resultados evidenciados pela TDFR foi desenvolvida através de simulações computacionais. Também serão apresentados resultados experimentais referentes ao sincronismo de um gerador síncrono com a rede elétrica, através dos sinais fornecidos pela TDFR.
Resumo:
This paper proposes a novel and simple positive sequence detector (PSD), which is inherently self-adjustable to fundamental frequency deviations by means of a software-based PLL (Phase Locked Loop). Since the proposed positive sequence detector is not based on Fortescue's classical decomposition and no special input filtering is needed, its dynamic response may be as fast as one fundamental cycle. The digital PLL ensures that the positive sequence components can be calculated even under distorted waveform conditions and fundamental frequency deviations. For the purpose of validating the proposed models, the positive sequence detector has been implemented in a PC-based Power Quality Monitor and experimental results illustrate its good performance. The PSD algorithm has also been evaluated in the control loop of a Series Active Filter and simulation results demonstrate its effectiveness in a closed-loop system. Moreover, considering single-phase applications, this paper also proposes a general single-phase PLL and a Fundamental Wave Detector (FWD) immune to frequency variations and waveform distortions. © 2005 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Background: Vibroacoustic disease (VAD) is a systematic pathology characterized by the abnormal growth of extra-cellular matrices in the absence of infl ammatory processes, namely collagen and elastin, both of which are abundant in the basement membrane zone of the vocal folds. VAD can develop due to long-term exposure to infrasound and low-frequency noise (ILFN, <500 Hz). Mendes et al. (2006, 2008 and 2012) revealed that ILFN-exposed males and females presented an increased fundamental frequency (F0), decreased jitter %, and reduced maximum phonation frequency range, when compared with normative data. Temporal measures of maximum phonation time and S/Z ratio were generally reduced. Study Aims: Herein, the same voice acoustic parameters of 48 males, 36 airline pilots and 12 cabin crewmembers (age range 25-60 years) were studied, and the effects and interaction of age and years of ILFN exposure were investigated within those parameters. ILFN-exposure time (i.e. years of professional activity) ranged from 3.5 to 36 years. Materials and Methods: Spoken and sung phonatory tasks were recorded with a DA-P1 Tascam DAT and a C420III PP AKG head-worn microphone, positioned at 3 cm from the mouth. Acoustic analyses were performed using KayPENTAX Computer Speech Lab and Multi-Dimensional Voice Program. Results: Results revealed that even though pilots and cabin crewmembers were exposed to occupational environments with distinct (ILFN-rich) acoustical frequency distributions and sound pressure levels, differences in the vocal acoustic parameters were not evident. Analyzing data from both professional groups (N = 48) revealed that F0 increased signifi cantly with the number of years of professional activity. Conclusion: These results strongly suggest that the number of years of professional activity (i.e. total ILFN exposure time) had a signifi cant effect on F0. Furthermore, they may refl ect the histological changes specifi cally observed on the vocal folds of ILFN-exposed professionals.
Resumo:
This work presents the study and development of a combined fault location scheme for three-terminal transmission lines using wavelet transforms (WTs). The methodology is based on the low- and high-frequency components of the transient signals originated from fault situations registered in the terminals of a system. By processing these signals and using the WT, it is possible to determine the time of travelling waves of voltages and/or currents from the fault point to the terminals, as well as estimate the fundamental frequency components. A new approach presents a reliable and accurate fault location scheme combining some different solutions. The main idea is to have a decision routine in order to select which method should be used in each situation presented to the algorithm. The combined algorithm was tested for different fault conditions by simulations using the ATP (Alternative Transients Program) software. The results obtained are promising and demonstrate a highly satisfactory degree of accuracy and reliability of the proposed method.
Resumo:
Voltage and current waveforms of a distribution or transmission power system are not pure sinusoids. There are distortions in these waveforms that can be represented as a combination of the fundamental frequency, harmonics and high frequency transients. This paper presents a novel approach to identifying harmonics in power system distorted waveforms. The proposed method is based on Genetic Algorithms, which is an optimization technique inspired by genetics and natural evolution. GOOAL, a specially designed intelligent algorithm for optimization problems, was successfully implemented and tested. Two kinds of representations concerning chromosomes are utilized: binary and real. The results show that the proposed method is more precise than the traditional Fourier Transform, especially considering the real representation of the chromosomes.
Resumo:
This paper presents a new methodology to estimate unbalanced harmonic distortions in a power system, based on measurements of a limited number of given sites. The algorithm utilizes evolutionary strategies (ES), a development branch of evolutionary algorithms. The problem solving algorithm herein proposed makes use of data from various power quality meters, which can either be synchronized by high technology GPS devices or by using information from a fundamental frequency load flow, what makes the overall power quality monitoring system much less costly. The ES based harmonic estimation model is applied to a 14 bus network to compare its performance to a conventional Monte Carlo approach. It is also applied to a 50 bus subtransmission network in order to compare the three-phase and single-phase approaches as well as the robustness of the proposed method. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
This paper discusses the need to simultaneously monitor voltage unbalance and harmonic distortions in addition to root-mean-square voltage values. An alternative way to obtain the parameters related to voltage unbalance at fundamental frequency as well as voltage harmonic distortions is here proposed, which is based on the representation of instantaneous values at the axes and at the instantaneous Euclidean norm. A new power-quality (PQ) index is then proposed to combine the effects of voltage unbalance and harmonic distortions. This new index is easily implemented into existing electronic power meters. This PQ index is determined from the analysis of temperature rise in induction motor windings, which were tested for long periods of time. This paper also shows that these voltage disturbances, which are harmful to the lifetime expectancy of motors, can be measured by alternative ways in relation to conventional methods. Although this paper deals with induction motors only, the results show the relevance for further studies on other pieces of equipment.
Resumo:
This paper presents a new methodology to estimate harmonic distortions in a power system, based on measurements of a limited number of given sites. The algorithm utilizes evolutionary strategies (ES), a development branch of evolutionary algorithms. The main advantage in using such a technique relies upon its modeling facilities as well as its potential to solve fairly complex problems. The problem-solving algorithm herein proposed makes use of data from various power-quality (PQ) meters, which can either be synchronized by high technology global positioning system devices or by using information from a fundamental frequency load flow. This second approach makes the overall PQ monitoring system much less costly. The algorithm is applied to an IEEE test network, for which sensitivity analysis is performed to determine how the parameters of the ES can be selected so that the algorithm performs in an effective way. Case studies show fairly promising results and the robustness of the proposed method.