960 resultados para FONTAN OPERATION


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To compare immediate and late results in patients with or without fenestration who underwent cavopulmonary anastomosis so that we could assess the efficiency of the technique. METHODS: Sixty-two patients underwent surgery between 1988 and 1999, 41 with fenestration (group I -G I) and 21 without fenestration (group II -G II). Tricuspid atresia was prevalent in group I (23-56%) and single ventricle was prevalent in group II (14-66%). Mean ages at the time of operation were 7.3 years in group I and 7.6 in group II. At late follow-up, mean ages were 10.6 years in group I and 12.8 years in group II. RESULTS: Immediate and late mortality were 7.3% in G-I and 4.7% in G-II. Significant pleural effusion occurred in 41.4% of G-I patients and in 23.8% of G-II patients. Significant pericardial effusion occurred in 29.2% and 14.2%, respectively, in groups I and II. Central venous pressure was greater in G-II, 17.7 cm in H2O, as opposed to 15 cm in G-I. Hospital stay was similar between the groups, 26.3 and 21.8 days, respectively. Cyanosis and arterial insaturation occurred in 5 patients, and 4 patients were in functional class II, all from G-I. At late follow-up, 58 (93.5%) were in functional class I. Sinus rhythm was present in 94%, and pulmonary perfusion was similar in both groups. Eleven patients who underwent spirometry had good tolerance to physical effort. CONCLUSION: Atrial fenestration did not improve the immediate or late follow-up of patients who underwent cavopulmonary anastomosis, and is, therefore, dispensable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Evaluation of the long-term clinical results of the Fontan operation in patients with tricuspid atresia. METHODS: A retrospective analysis was made at the Instituto de Cardiologia do Rio Grande do Sul (Institute of Cardiology of Rio Grande do Sul), from August 1980 through January 2000, of 25 patients with a long-term follow-up, out of a series of 36 patients who underwent the Fontan operation or one of its variants due to tricuspid atresia. Their mean age at surgery was 5.4±3.1 years, and their mean weight was 15.8±6.1 kg, the majority of them (63.9%) being males. Four patients underwent the classical Fontan operation, 12 the Kreutzer variant, 6 the Björk variant, 9 total cavopulmonary shunt with a fenestrated tube, and 5 total cavopulmonary shunt with a nonfenestrated tube. RESULTS: The patients were followed-up on an outpatient basis, with a mean long-term survival time of 5.5±4.2 years (50 days to 17.8 years) and a late mortality rate of 8%. Arterial saturation increased from 77.2±18.8% in the preoperative period to 91±6.7% upon the last outpatient visit (p>0.05). At the final check, most (67%) patients were asymptomatic and 87% could tolerate exercise. Ten (40%) patients experienced some kind of complication during the long-term follow-up, such as cardiac arrhythmia, cyanosis, protein-losing enteropathy, neurological events, right heart failure, intolerance to exercise and reoperation. CONCLUSION: The results indicate that, once the immediate postoperative period is over, during which the adaptations to the new circulatory physiology occur, the evolution of patients with tricuspid atresia who underwent the Fontan operation is satisfactory, in spite of a low, yet significant, morbidity.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cavopulmonary connections have been extensively used in the palliation of complex forms of congenital heart disease requiring some form of right heart bypass. We examine the mid term outcomes of pulmonary ventricle bypass operations in a single institution and performed by the same surgical team. POPULATION: Between March 1999 and April 2006, 62 patients underwent pulmonary ventricle bypass operations: bidirectional cavopulmonary anastomosis (Glenn procedure), total cavopulmonary connections (Fontan procedure) and one and a half ventricle correction in two cases. Age at operation averaged three years (range: 0.42-25 years) for the Glenn procedure and seven years (range: 3-14 years) for the Fontan procedure. There were 36 male patients (58%) and 26 female patients (42%). The most common indication for surgery was the single ventricle defect, present in 66% of patients. Associated lesions included: transposition of the great arteries in 16 patients (35.6%), bilateral superior vena cava in four patients (8.9%), situs ambigus in five patients (11%), situs inversus in another patient (2.2%), Ebstein disease in one patient (2.2) and coronary fistula in another patient (2.2%). Sub-aortic stenosis was present in one patient (2.2%). Palliative surgery was performed in all, but three patients (5%), before the Fontan procedure. RESULTS: Thirty two patients underwent bidirectional cavopulmonary anastomosis and thirty patients underwent cavopulmonary connections, total or 2nd stage. Mean cardiopulmonary bypass times were 50.6+/-21.9 minutes for the Glenn procedure and 88.5+/-26.3 minutes for the Fontan procedure. There was no intra-operative mortality, but two patients (3.2% (died in the first month after surgery; one due to failure of the Glenn circuit and sepsis and the other due to a low cardiac output syndrome and multi-organ dysfunction. Mean ventilation time was 5.2+/-1.7 hours for the Glenn operation and 6.2+/-3.2 hours for the Fontan operation. The mean length of stay in ICU was 3.4+/-2.8 days for patients undergoing the Glenn operation and 4.6+/-3.1 days for patients undergoing the Fontan operation and the mean length of hospital stay was 10.6+/-5.8 days for the Glenn operation and 19.1+/-12.6 days for the Fontan operation respectively. The mean follow up time was 4+/-2.1 years (minimum 0 years and maximum seven years), most patients being in NYHA class I. Epicardiac pacemakers were implanted in three patients due to arrhythmias. Two re-operations (6.7%) were needed, both in the same patient, after the Fontan procedure, this patient eventually died a few years after surgery. CONCLUSIONS: The immediate and mid term outcomes of pulmonary ventricle bypass operations can have excellent results. From our point of view there has been an improvement, namely in the use of the extracardiac conduit technique in the 2nd stage of the Fontan operation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La BCPA e’ ormai utilizzata routinariamente come stadio intermedio della palliazione di Fontan nel trattamento dei cuori funzionalmente univentricolari e si conferma intervento a ridotta mortalità e morbilità. La crescita delle arterie polmonari dopo BCPA è abbastanza variabile ed imprevedibile, le dimensioni indicizzate dei rami principali sembrano tendenzialmente ridotte, tranne quelle dell’arteria lobare inferiore destra, la quale beneficerebbe del flusso preferenziale della BCPA. Proprio i pazienti con arterie polmonari più piccole mostrerebbero un maggior incremento di dimensioni delle stesse dopo BPCA. Il ruolo ed i vantaggi del flusso accessorio nella BCPA sono ancora da definire; tuttavia sembrerebbe offrire vantaggi in termini di crescita delle arterie polmonari, soprattutto il ramo lobare sinistro, e di miglior outcome dopo TCPC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Thrombosis has been widely described after the Fontan procedure. The vascular endothelium plays a central role in the control of coagulation and fibrinolysis. The aim of this study was to investigate if patients undergoing a modified Fontan procedure have impaired endothelial function and fibrinolysis in the late postoperative course. Patients and methods: We compared 23 patients aged from 7 to 26 years with age-matched healthy volunteers, collecting blood samples prior to and following standardized venous occlusion testing. Plasma levels of von Willebrand factor antigen, tissue-type plasminogen activator antigen, plasminogen activator inhibitor-1, and D-dimer were measured with enzyme-linked immunosorbent assay. Results: We found increased plasma levels of von Willebrand factor antigen in patients when compared to controls (p = 0.003). At the basal condition, concentrations of tissue-type plasminogen activator antigen and plasminogen activator inhibitor-1 antigen in the plasma, as well as their activity, were not significantly different between patients and controls. Following venous occlusion, concentrations of tissue-type plasminogen activator antigen in the plasma were significantly increased both in patients and controls, compared to pre-occlusion values. D-dimer was within the reference range. Multivariate discriminant analysis differentiated patients and their controls on the basis of differences for plasminogen activator inhibitor-1 and von Willebrand factor antigen (p = 0.0016). Conclusions: Our data suggest that patients with the Fontan circulation may have endothelial dysfunction, as indicated by raised levels of von Willebrand factor. Fibrinolysis seems to be relatively preserved, as suggested by appropriate response to venous occlusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By the use of installed fibers inside the city we demonstrated a 48.8 km ultralong Erbium-doped fiber laser in modelocking regime with repetition rate varying from 1-10 GHz. The shortest pulse duration of 42 ps at 2.5 GHz was obtained by optimization of intracavity dispersion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of flow type and rotor speed was investigated in a round-bottom reactor with 5 L useful volume containing 2.0 L of granular biomass. The reactor treated 2.0 L of synthetic wastewater with a concentration of 800 mgCOD/L in 8-h cycles at 30 degrees C. Five impellers, commonly used in biological processes, have been employed to this end, namely: a turbine and a paddle impeller with six-vertical-flat-blades, a turbine and a paddle impeller with six-45 degrees-inclined-flat-blades and a three-blade-helix impeller. Results showed that altering impeller type and rotor speed did not significantly affect system stability and performance. Average organic matter removal efficiency was about 84% for filtered samples, total volatile acids concentration was below 20 mgHAc/L and bicarbonate alkalinity a little less than 400 mgCaCO(3)/L for most of the investigated conditions. However, analysis of the first-order kinetic model constants showed that alteration in rotor speed resulted in an increase in the values of the kinetic constants (for instance, from 0.57 h(-1) at 50 rpm to 0.84 h(-1) at 75 rpm when the paddle impeller with six-45 degrees-inclined-flat-blades was used) and that axial flow in mechanically stirred reactors is preferable over radial-flow when the vertical-flat-blade impeller is compared to the inclined-flat-blade impeller (for instance at 75 rpm, from 0.52 h(-1) with the six-flat-blade-paddle impeller to 0.84 h(-1) with the six-45 degrees-inclined-flat-blade-paddle impeller), demonstrating that there is a rotor speed and an impeller type that maximize solid-liquid mass transfer in the reaction medium. Furthermore, power consumption studies in this reduced reactor volume showed that no high power transfer is required to improve mass transfer (less than 0.6 kW/10(3) m(3)). (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of an optimization model for the management and operation of a large-scale, multireservoir water supply distribution system with preemptive priorities. The model considers multiobjectives and hedging rules. During periods of drought, when water supply is insufficient to meet the planned demand, appropriate rationing factors are applied to reduce water supply. In this paper, a water distribution system is formulated as a network and solved by the GAMS modeling system for mathematical programming and optimization. A user-friendly interface is developed to facilitate the manipulation of data and to generate graphs and tables for decision makers. The optimization model and its interface form a decision support system (DSS), which can be used to configure a water distribution system to facilitate capacity expansion and reliability studies. Several examples are presented to demonstrate the utility and versatility of the developed DSS under different supply and demand scenarios, including applications to one of the largest water supply systems in the world, the Sao Paulo Metropolitan Area Water Supply Distribution System in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal performance of a cooling tower and its cooling water system is critical for industrial plants, and small deviations from the design conditions may cause severe instability in the operation and economics of the process. External disturbances such as variation in the thermal demand of the process or oscillations in atmospheric conditions may be suppressed in multiple ways. Nevertheless, such alternatives are hardly ever implemented in the industrial operation due to the poor coordination between the utility and process sectors. The complexity of the operation increases because of the strong interaction among the process variables. In the present work, an integrated model for the minimization of the operating costs of a cooling water system is developed. The system is composed of a cooling tower as well as a network of heat exchangers. After the model is verified, several cases are studied with the objective of determining the optimal operation. It is observed that the most important operational resources to mitigate disturbances in the thermal demand of the process are, in this order: the increase in recycle water flow rate, the increase in air flow rate and finally the forced removal of a portion of the water flow rate that enters the cooling tower with the corresponding make-up flow rate. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FinFETs are recognized as promising candidates for the CMOS nanometer era. In this paper the most recent results for cryogenic operation of FinFETs will be demonstrated with special emphasis on analog applications. Threshold voltage, subthreshold slope and carrier mobility will be studied. Also some important figures of merit for analog circuit operation as for readout electronics, such as transconductance, output conductance and intrinsic voltage gain will be covered. It is demonstrated that the threshold voltage of undoped narrow FinFETs is less temperature-dependent than for a planar single-gate device with similar doping concentration. The temperature reduction improves the transconductance over drain current ratio in any operational region. On the other hand, the output conductance is degraded when the temperature is reduced. The combination of these effects shows that the intrinsic gain of a L = 90 nm FinFET is degraded by 2 dB when the temperature reduces from 300 K to 100 K. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work characterizes the analog performance of SOI n-MuGFETs with HfSiO gate dielectric and TiN metal gate with respect to the influence of the high-k post-nitridation. TiN thickness and device rotation. A thinner TiN metal gate is found favorable for improved analog characteristics showing an increase in intrinsic voltage gain. The devices where the high-k material is subjected to a nitridation step indicated a degradation of the Early voltage (V(EA)) values which resulted in a lower voltage gain. The 45 degrees rotated devices have a smaller V(EA) than the standard ones when a HfSiO dielectric is used. However, the higher transconductance of these devices, due to the increased mobility in the (1 0 0) sidewall orientation, compensates this V(EA) degradation of the voltage gain, keeping it nearly equal to the voltage gain values of the standard devices. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter presents the properties of nMOS junctionless nanowire transistors (JNTs) under cryogenic operation. Experimental results of drain current, subthreshold slope, maximum transconductance at low electric field, and threshold voltage, as well as its variation with temperature, are presented. Unlike in classical devices, the drain current of JNTs decreases when temperature is lowered, although the maximum transconductance increases when the temperature is lowered down to 125 K. An analytical model for the threshold voltage is proposed to explain the influence of nanowire width and doping concentration on its variation with temperature. It is shown that the wider the nanowire or the lower the doping concentration, the higher the threshold voltage variation with temperature.