169 resultados para FEV1


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spirometry is the most widely used lung function test in the world. It is fundamental in diagnostic and functional evaluation of various pulmonary diseases. In the studies described in this thesis, the spirometric assessment of reversibility of bronchial obstruction, its determinants, and variation features are described in a general population sample from Helsinki, Finland. This study is a part of the FinEsS study, which is a collaborative study of clinical epidemiology of respiratory health between Finland (Fin), Estonia (Es), and Sweden (S). Asthma and chronic obstructive pulmonary disease (COPD) constitute the two major obstructive airways diseases. The prevalence of asthma has increased, with around 6% of the population in Helsinki reporting physician-diagnosed asthma. The main cause of COPD is smoking with changes in smoking habits in the population affecting its prevalence with a delay. Whereas airway obstruction in asthma is by definition reversible, COPD is characterized by fixed obstruction. Cough and sputum production, the first symptoms of COPD, are often misinterpreted for smokers cough and not recognized as first signs of a chronic illness. Therefore COPD is widely underdiagnosed. More extensive use of spirometry in primary care is advocated to focus smoking cessation interventions on populations at risk. The use of forced expiratory volume in six seconds (FEV6) instead of forced vital capacity (FVC) has been suggested to enable office spirometry to be used in earlier detection of airflow limitation. Despite being a widely accepted standard method of assessment of lung function, the methodology and interpretation of spirometry are constantly developing. In 2005, the ATS/ERS Task Force issued a joint statement which endorsed the 12% and 200 ml thresholds for significant change in forced expiratory volume in one second (FEV1) or FVC during bronchodilation testing, but included the notion that in cases where only FVC improves it should be verified that this is not caused by a longer exhalation time in post-bronchodilator spirometry. This elicited new interest in the assessment of forced expiratory time (FET), a spirometric variable not usually reported or used in assessment. In this population sample, we examined FET and found it to be on average 10.7 (SD 4.3) s and to increase with ageing and airflow limitation in spirometry. The intrasession repeatability of FET was the poorest of the spirometric variables assessed. Based on the intrasession repeatability, a limit for significant change of 3 s was suggested for FET during bronchodilation testing. FEV6 was found to perform equally well as FVC in the population and in a subgroup of subjects with airways obstruction. In the bronchodilation test, decreases were frequently observed in FEV1 and particularly in FVC. The limit of significant increase based on the 95th percentile of the population sample was 9% for FEV1 and 6% for FEV6 and FVC; these are slightly lower than the current limits for single bronchodilation tests (ATS/ERS guidelines). FEV6 was proven as a valid alternative to FVC also in the bronchodilation test and would remove the need to control duration of exhalation during the spirometric bronchodilation test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Better characterization of childhood wheeze phenotypes using newer statistical methods provides a basis for addressing the heterogeneity of childhood asthma. Outcomes of these phenotypes beyond childhood are unknown.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Pseudomonas aeruginosa is the most common bacterial pathogen in cystic fibrosis (CF) patients. Current infection control guidelines aim to prevent transmission via contact and respiratory droplet routes and do not consider the possibility of airborne transmission. We hypothesized that with coughing, CF subjects produce viable, respirable bacterial aerosols. Methods: Cross-sectional study of 15 children and 13 adults with CF, 26 chronically infected with P. aeruginosa. A cough aerosol sampling system enabled fractioning of respiratory particles of different size, and culture of viable Gram negative non-fermentative bacteria. We collected cough aerosols during 5 minutes voluntary coughing and during a sputum induction procedure when tolerated. Standardized quantitative culture and genotyping techniques were used. Results: P. aeruginosa was isolated in cough aerosols of 25 (89%) subjects of whom 22 produced sputum samples. P. aeruginosa from sputum and paired cough aerosols were indistinguishable by molecular typing. In 4 cases the same genotype was isolated from ambient room air. Approximately 70% of viable aerosols collected during voluntary coughing were of particles ≤ 3.3 microns aerodynamic diameter. P. aeruginosa, Burkholderia cenocepacia Stenotrophomonas maltophilia and Achromobacter xylosoxidans were cultivated from respiratory particles in this size range. Positive room air samples were associated with high total counts in cough aerosols (P=0.003). The magnitude of cough aerosols were associated with higher FEV1 (r=0.45, P=0.02) and higher quantitative sputum culture results (r=0.58, P=0.008). Conclusion: During coughing, CF patients produce viable aerosols of P. aeruginosa and other Gram negative bacteria of respirable size range, suggesting the potential for airborne transmission.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While several randomised control trials (RCTs) have evaluated the use of fractional exhaled nitric oxide (FeNO) to improve asthma outcomes, none used FeNO cut-offs adjusted for atopy, a determinant of FeNO levels. In a dual centre RCT, we assessed whether a treatment strategy based on FeNO levels, adjusted for atopy, reduces asthma exacerbations compared with the symptoms-based management (controls). Children with asthma from hospital clinics of two hospitals were randomly allocated to receive an a-priori determined treatment hierarchy based on symptoms or FeNO levels. There was a 2-week run-in period and they were then reviewed ten times over 12-months. The primary outcome was the number of children with exacerbations over 12-months. Sixty-three children were randomised (FeNO=31, controls=32); 55 (86%) completed the study. Although we did achieve our planned sample size, significantly fewer children in the FeNO group (6 of 27) had an asthma exacerbation compared to controls (15 of 28), p=0.021; number to treat for benefit=4 (95%CI 3-24). There was no difference between groups for any secondary outcomes (quality of life, symptoms, FEV1). The final daily inhaled corticosteroids (ICS) dose was significantly (p=0.037) higher in the FeNO group (median 400µg, IQR 250-600) compared to the controls (200, IQR100-400). Taking atopy into account when using FeNO to tailor asthma medications is likely beneficial in reducing the number of children with severe exacerbations at the expense of increased ICS use. However, the strategy is unlikely beneficial for improving asthma control. A larger study is required to confirm or refute our findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rationale Nutritional support is effective in managing malnutrition in COPD (Collins et al., 2012) leading to functional improvements (Collins et al., 2013). However, comparative trials of first line interventions are lacking. This randomised trial compared the effectiveness of individualised dietary advice by a dietitian (DA) versus oral nutritional supplements (ONS). Methods A target sample of 200 stable COPD outpatients at risk of malnutrition (‘MUST’; medium + high risk) were randomised to either a 12-week intervention of ONS (ONS: ~400 kcal/d, ~40 g/d protein) or DA with supportive written advice. The primary outcome was quality of life (QoL) measured using St George’s Respiratory Questionnaire with secondary outcomes including handgrip strength, body weight and nutritional intake. Both the change from baseline and the differences between groups was analysed using SPSS version 20. Results 84 outpatients were recruited (ONS: 41 vs. DA: 43), 72 completed the intervention (ONS: 33 vs. DA: 39). Mean BMI was 18.2 SD 1.6 kg/m2, age 72.6 SD 10 years, FEV1% predicted 36 SD 15% (severe COPD). In comparison to the DA group, the ONS group experienced significantly greater improvements in protein intakes above baseline values at both week 6 (+21.0 SEM 4.3 g/d vs. +0.52 SEM 4.3 g/d; p < 0.001) and week 12 (+19.0 SEM 5.0 g/d vs. +1.0 SEM 3.6 g/d; p = 0.033;ANOVA). QoL and secondary outcomes remained stable at 12 weeks in both groups with slight improvements in the ONS group but no differences between groups. Conclusion In outpatients at risk of malnutrition with severe COPD, nutritional support involving either ONS or DA appears to maintain in tritional status, functional capacity and QoL. However, larger trials, and earlier, multi-modal nutritional interventions for an extended duration should be explored.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several clinical studies suggest the involvement of premature ageing processes in chronic obstructive pulmonary disease (COPD). Using an epidemiological approach, we studied whether accelerated ageing indicated by telomere length, a marker of biological age, is associated with COPD and asthma, and whether intrinsic age-related processes contribute to the interindividual variability of lung function. Our meta-analysis of 14 studies included 934 COPD cases with 15 846 controls defined according to the Global Lungs Initiative (GLI) criteria (or 1189 COPD cases according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria), 2834 asthma cases with 28 195 controls, and spirometric parameters (forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC) of 12 595 individuals. Associations with telomere length were tested by linear regression, adjusting for age, sex and smoking status. We observed negative associations between telomere length and asthma (β= −0.0452, p=0.024) as well as COPD (β= −0.0982, p=0.001), with associations being stronger and more significant when using GLI criteria than those of GOLD. In both diseases, effects were stronger in females than males. The investigation of spirometric indices showed positive associations between telomere length and FEV1 (p=1.07×10−7), FVC (p=2.07×10−5), and FEV1/FVC (p=5.27×10−3). The effect was somewhat weaker in apparently healthy subjects than in COPD or asthma patients. Our results provide indirect evidence for the hypothesis that cellular senescence may contribute to the pathogenesis of COPD and asthma, and that lung function may reflect biological ageing primarily due to intrinsic processes, which are likely to be aggravated in lung diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Bronchiectasis is a major contributor to chronic respiratory morbidity and mortality worldwide. Wheeze and other asthma-like symptoms and bronchial hyperreactivity may occur in people with bronchiectasis. Physicians often use asthma treatments in patients with bronchiectasis. OBJECTIVES To assess the effects of inhaled long-acting beta2-agonists (LABA) combined with inhaled corticosteroids (ICS) in children and adults with bronchiectasis during (1) acute exacerbations and (2) stable state. SEARCH METHODS The Cochrane Airways Group searched the the Cochrane Airways Group Specialised Register of Trials, which includes records identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and other databases. The Cochrane Airways Group performed the latest searches in October 2013. SELECTION CRITERIA All randomised controlled trials (RCTs) of combined ICS and LABA compared with a control (placebo, no treatment, ICS as monotherapy) in children and adults with bronchiectasis not related to cystic fibrosis (CF). DATA COLLECTION AND ANALYSIS Two review authors extracted data independently using standard methodological procedures as expected by The Cochrane Collaboration. MAIN RESULTS We found no RCTs comparing ICS and LABA combination with either placebo or usual care. We included one RCT that compared combined ICS and LABA with high-dose ICS in 40 adults with non-CF bronchiectasis without co-existent asthma. All participants received three months of high-dose budesonide dipropionate treatment (1600 micrograms). After three months, participants were randomly assigned to receive either high-dose budesonide dipropionate (1600 micrograms per day) or a combination of budesonide with formoterol (640 micrograms of budesonide and 18 micrograms of formoterol) for three months. The study was not blinded. We assessed it to be an RCT with overall high risk of bias. Data analysed in this review showed that those who received combined ICS-LABA (in stable state) had a significantly better transition dyspnoea index (mean difference (MD) 1.29, 95% confidence interval (CI) 0.40 to 2.18) and cough-free days (MD 12.30, 95% CI 2.38 to 22.2) compared with those receiving ICS after three months of treatment. No significant difference was noted between groups in quality of life (MD -4.57, 95% CI -12.38 to 3.24), number of hospitalisations (odds ratio (OR) 0.26, 95% CI 0.02 to 2.79) or lung function (forced expiratory volume in one second (FEV1) and forced vital capacity (FVC)). Investigators reported 37 adverse events in the ICS group versus 12 events in the ICS-LABA group but did not mention the number of individuals experiencing adverse events. Hence differences between groups were not included in the analyses. We assessed the overall evidence to be low quality. AUTHORS' CONCLUSIONS In adults with bronchiectasis without co-existent asthma, during stable state, a small single trial with a high risk of bias suggests that combined ICS-LABA may improve dyspnoea and increase cough-free days in comparison with high-dose ICS. No data are provided for or against, the use of combined ICS-LABA in adults with bronchiectasis during an acute exacerbation, or in children with bronchiectasis in a stable or acute state. The absence of high quality evidence means that decisions to use or discontinue combined ICS-LABA in people with bronchiectasis may need to take account of the presence or absence of co-existing airway hyper-responsiveness and consideration of adverse events associated with combined ICS-LABA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Effects of nutritional supplements on minimizing weight loss and abnormalities of protein turnover during pulmonary exacerbations in cystic fibrosis (CF) were studied by controlled trial. Patients received pulmonary therapy and either standard diet (n = 10) or adjunctive enteral supplements (n = 12). Initial protein turnover, measured by [15N]glycine kinetics, showed alterations of protein synthesis (P Syn) and catabolism (P Cat), which correlated with the degree of underweight, and negligible net protein deposition (P Dep). With treatment both groups had significant increases in mean body weight and forced expiratory volume in 1 s, expressed as percent predicted value for height (FEV1) by 3 wk, but a significant correlation between initial underweight and subsequent weight gain was observed only in supplemented patients. Mean P Syn and P Dep increased significantly (p < 0.001) only in the supplemented group. Pulmonary exacerbations in CF have important adverse effects on body-protein metabolism, similar to changes in protein-energy malnutrition and infection. These effects are reversed by short-term nutritional support. Strategic nutritional intervention should thus be considered in management, especially in malnourished patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atopic dermatitis (AD) or atopic eczema is characterised by a superficial skin inflammation with an overall Th2 cell dominance and impaired function of the epidermal barrier. Patients also are at an increased risk for asthma and allergic rhinitis. Treatment with tacrolimus ointment inhibits T cell activation and blocks the production of several inflammatory cytokines in the skin, without suppressing collagen synthesis. The aims of this thesis were to determine: (1) long-term efficacy, safety, and effects on cell-mediated immunity and serum IgE levels in patients with moderate-to-severe AD treated for 1 year with tacrolimus ointment or a corticosteroid regimen, (2) the 10-year outcome of eczema, respiratory symptoms, and serum IgE levels in AD patients initially treated long-term with tacrolimus ointment, and (3) pharmacokinetics and long-term safety and efficacy of 0.03% tacrolimus ointment in infants under age 2 with AD. Cell-mediated immunity, reflecting Th1 cell reactivity, was measured by recall antigens and was at baseline lower in patients with AD compared to healthy controls. Treatment with either 0.1% tacrolimus ointment or a corticosteroid regimen for one year enhanced recall antigen reactivity. Transepidermal water loss (TEWL), an indicator of skin barrier function, decreased at months 6 and 12 in both tacrolimus- and corticosteroid-treated patients; TEWL for the head and neck was significantly lower in tacrolimus-treated patients. Patients in the 10-year open follow-up study showed a decrease in affected body surface area from a baseline 19.0% to a 10-year 1.6% and those with bronchial hyper-responsiveness at baseline showed an increase in the provocative dose of inhaled histamine producing a 15% decrease in FEV1, indicating less hyper-responsiveness. Respiratory symptoms (asthma and rhinitis) reported by the patient decreased in those with active symptoms at baseline. A good treatment response after one year of tacrolimus treatment predicted a good treatment response throughout the 10-year follow-up and a decrease in total serum IgE levels at the 10-year follow-up visit. The 2-week pharmacokinetic and the long-term study with 0.03% tacrolimus ointment showed good and continuous improvement of AD in the infants. Tacrolimus blood levels were throughout the study low and treatment well tolerated. This thesis underlines the importance of effective long-term topical treatment of AD. When the active skin inflammation decreases, cell-mediated immunity of the skin improves and a secondary marker for Th2 cell reactivity, total serum IgE, decreases. Respiratory symptoms seem to improve when the eczema area decreases. All these effects can be attributed to improvement of skin barrier function. One potential method to prevent a progression from AD to asthma and allergic rhinitis may be avoidance of early sensitisation through the skin, so early treatment of AD in infants is crucial. Long-term treatment with 0.03% tacrolimus ointment was effective and safe in infants over age 3 months.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic obstructive pulmonary disease (COPD) is a slowly progressive disease characterized by airway inflammation and largely irreversible airflow limitation. One major risk factor for COPD is cigarette smoking. Since the inflammatory process starts many years prior to the onset of clinical symptoms and still continues after smoking cessation, there is an urgent need to find simple non-invasive biomarkers that can be used in the early diagnosis of COPD and which could help in predicting the disease progression. The first aim of the present study was to evaluate the involvement of different oxidative/nitrosative stress markers, matrix metalloproteinases (MMPs) and their tissue inhibitor-1 (TIMP-1) in smokers and in COPD. Elevated numbers of inducible nitric oxide synthase (iNOS), nitrotyrosine, myeloperoxidase (MPO) and 4-hydroxy-2-nonenal (4-HNE) positive cells and increased levels of 8-isoprostane and lactoferrin were found in sputum of non-symptomatic smokers compared to non-smokers, and especially in subjects with stable mild to moderate COPD, and they correlated with the severity of airway obstruction. This suggests that an increased oxidant burden exists already in the airways of smokers with normal lung function values. However, none of these markers could differentiate healthy smokers from symptomatic smokers with normal lung function values i.e. those individuals who are at risk of developing COPD. In contrast what is known about asthma exhaled nitric oxide (FENO) was lower in smokers than in non-smokers, the reduced FENO value was significantly associated with neutrophilic inflammation and the elevated oxidant burden (positive cells for iNOS, nitrotyrosine and MPO). The levels of sputum MMP-8 and plasma MMP-12 appeared to differentiate subjects who have a risk for COPD development but these finding require further investigations. The levels of all studied MMPs correlated with the numbers of neutrophils, and MMP-8 and MMP-9 with markers of neutrophil activation (MPO, lactoferrin) suggesting that especially neutrophil derived oxidants may stimulate the tissue destructive MMPs already in lungs of smokers who are not yet experiencing any airflow limitation. When investigating the role of neutrophil proteases (neutrophil elastase, MMP-8, MMP-9) during COPD exacerbation and its recovery period, we found that levels of all these proteases were increased in sputum of patients with COPD exacerbation as compared to stable COPD and controls, and decreased during the one-month recovery period, giving evidence for a role of these enzymes in COPD exacerbations. In the last study, the effects of subject`s age and smoking habits were evaluated on the plasma levels of surfactant protein A (SP-A), SP-D, MMP-9 and TIMP-1. Long-term smoking increased the levels of all of these proteins. SP-A most clearly correlated with age, pack years and lung function decline (FEV1/FVC), and based on the receiver operating characteristic curve analysis, SP-A was the best marker for discriminating subjects with COPD from controls. In conclusion, these findings support the hypothesis that especially neutrophil derived oxidants may activate MMPs and induce an active remodeling process already in the lungs of smokers with normal lung function values. The marked increase of sputum levels of neutrophil proteases in smokers, stable COPD and/or during its exacerbations suggest that these enzymes play a role in the development and progression of COPD. Based on the comparison of various biomarkers, SP-A can be proposed to serve as sensitive biomarker in COPD development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O crescimento do percentual de idosos na população ocorre mundialmente tornando necessário conhecer o impacto do processo de envelhecimento, neste contexto, do sistema respiratório. O desconhecimento do impacto do envelhecimento associado a diferentes graus de exposição a poluentes e a presença de comorbidade(s) dificulta a diagnose das pneumopatias acarretando aos idosos piora da qualidade de vida. São vantagens da Técnica de Oscilações Forçadas (FOT): alto potencial de aplicação em idosos, fácil realização, análise detalhada da mecânica respiratória, desempenho de papel complementar, bem como de alternativa na impossibilidade de realização dos exames tradicionais. Foi realizado um estudo experimental comparativo que objetivou investigar o impacto do envelhecimento no sistema respiratório pela FOT e pela espirometria entre grupos de diferentes faixas etárias, sendo a idade a variável independente e as variáveis dependentes, os parâmetros oscilométricos resistência em regime contínuo (R0) e das vias aéreas centrais (Rm), inclinação da resistência (S), frequência de ressonância (fr), reatância média (Xm), complacência dinâmica (Cdin,sr) e os parâmetros espirométricos (VEF1, CVF, VEF1/CVF e FEF/CVF). Foram realizados entrevista, exame clínico, radiografia torácica, avaliação da mecânica respiratória pela FOT e da função pulmonar pela espirometria. 255 indivíduos com idades entre 20 e 86 anos foram entrevistados. Destes, 175 foram excluídos, restando os 80 voluntários analisados, que foram divididos em 6 grupos de acordo com a faixa etária (A: 20 a 29 anos; B: 30 a 39 anos; C: 40 a 49 anos; D: 50 a 59 anos; E: 60 a 69 anos; F: 70 anos ou mais). Foram utilizados os testes de Shapiro-Wilkins, na avaliação da normalidade dos dados biométricos em cada grupo, Oneway ANOVA, na comparação entre os grupos, e Tukey HSD na comparação entre as classes subjacentes. A análise da associação entre duas variáveis foi realizada inicialmente pela regressão univariada entre os parâmetros oscilométricos, a idade e a altura. A regressão múltipla entre os parâmetros oscilométricos, idade e altura foi realizada em conjunto. Foi realizada a análise de confundimento ou modificação de efeito sobre o parâmetro altura na relação entre a idade e os parâmetros oscilométricos. A correção pelo fator altura foi realizada quando sua análise apresentava fator de confundimento. Quanto aos parâmetros resistivos, não foram observadas alterações em R0 e Rm com o envelhecimento enquanto que o declínio observado em S é discreto e não-significativo. Em relação aos parâmetros reativos, verificouse que Cdin,sr e Xm diminuem enquanto que fr aumenta com o processo de envelhecimento. Todas estas alterações são significativas. Todavia, a diminuição da Cdin,sr não apresenta relação com a idade e sim com a altura, que constituiu modificação do efeito. Nos demais parâmetros oscilométricos, a altura constituiu fator de confundimento. Quanto à espirometria, observou-se declínio significativo do VEF1, do VEF1/CVF e da CVF. O índice FEF/CVF apresentou declínio nãosignificativo. Concluindo, a resistência do sistema respiratório e a complacência dinâmica não se modificam enquanto a homogeneidade do sistema respiratório diminui com o processo de envelhecimento.